Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.Aims
Methods
Aims. Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. Methods. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was
Aims. Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. Methods. A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value. Results. A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm. Conclusion. Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good
Aims. Proper preoperative planning benefits
Lateral-entry wiring (LEW) for displaced supracondylar humeral fractures (SHFs) has been popularised internationally. BOAST guidance suggests either LEW or crossed wires; the latter has reported lower risk of loss of
This prospective randomised trial aimed to assess the superiority of internal fixation of well-reduced medial malleolar fractures (displacement □2mm) compared with non-fixation, following fibular stabilisation in patients undergoing surgical management of a closed unstable ankle fracture. A total of 154 adult patients with a bi- or trimalleolar fracture were recruited from a single centre. Open injuries and vertically unstable medial malleolar fractures were excluded. Following fibular stabilisation, patients were randomised intra-operatively on a 1:1 basis to fixation or non-fixation after satisfactory fluoroscopic
The surgical care of extra-articular distal tibial fractures remains controversial. This study looks at the radiological outcomes of distal tibial fractures treated with either a direct medial or anterolateral plate, with or without plating of the fibula, to assess the outcome and complications associated with these 2 approaches. This is a retrospective review of 80 patients with distal tibial extra-articular fractures, treated with an open reduction and plating, between 2008 and 2019 at Glasgow Royal Infirmary. Case notes and x-rays were reviewed. Of those tibial fractures fixed with only a medial plate, 78% united (28/36), 5% (2/36) had a non-union and 17% (6/36) a malunion. In the group treated with a combination of medial tibial and fibular plating, the figures were; 71% (15/21), 19% (4/21) and 10% (2/21). However, in the group treated with anterolateral plating of the tibia alone, only 53% (8/15) united, with a 20% (3/15) non-union and 13% (2/15) malunion rate. Additionally in this group, there were 2 patients (13%) with loss of
Aims. The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size. Methods. This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of
To assess the feasibility of a randomized controlled trial (RCT) that compares three treatments for acetabular fractures in older patients: surgical fixation, surgical fixation and hip arthroplasty (fix-and-replace), and non-surgical treatment. Patients were recruited from seven UK NHS centres and randomized to a three-arm pilot trial if aged older than 60 years and had a displaced acetabular fracture. Feasibility outcomes included patients’ willingness to participate, clinicians’ capability to recruit, and dropout rates. The primary clinical outcome measure was the EuroQol five-dimension questionnaire (EQ-5D) at six months. Secondary outcomes were Oxford Hip Score, Disability Rating Index, blood loss, and radiological and mobility assessments.Aims
Methods
Factors associated with high mortality rates in geriatric hip fracture patients are frequently unmodifiable. Time to surgery, however, might be a modifiable factor of interest to optimize clinical outcomes after hip fracture surgery. This study aims to determine the influence of postponement of surgery due to non-medical reasons on clinical outcomes in acute hip fracture surgery. This observational cohort study enrolled consecutively admitted patients with a proximal femoral fracture, for which surgery was performed between 1 January 2018 and 11 January 2021 in two level II trauma teaching hospitals. Patients with medical indications to postpone surgery were excluded. A total of 1,803 patients were included, of whom 1,428 had surgery < 24 hours and 375 had surgery ≥ 24 hours after admission.Aims
Methods
Background. In a systematic review of 1125 distal tibia fractures treated with an intramedullary nail, the reported incidence of malalignment was 14%. The purpose of our study is to assess whether the addition of blocking screws during intramedullary nailing of a distal tibia fracture improved radiological outcomes. As a secondary outcome, the time to radiographic union was compared to see if a more rigid bone-implant construct had an effect on healing. Methods. We searched computerised records at a UK level 1 major trauma centre. The joint alignment was measured on the immediate post-operative radiograph and compared to the most recent radiograph. We used a difference of 2 degrees to indicate a progressive deformity and a RUST score greater or equal to 10, to indicate radiographic fracture union. Results. Twenty-seven patients were included. Nineteen patients had no blocking screw and 8 patients had a blocking screw. Five patients had a difference in their coronal plane alignment of 2 degrees or more (3/5 had no blocking screw). The results were analysed and found to be not statistically significant (p=0.88). The addition of a blocking screw has also been shown not to have an effect on the time to union. Conclusion. We have changed our surgical practice. We use a 2.5mm blocking wire to aid in
Introduction. Plate fixation for distal femoral fractures is a commonly used method of fracture stabilisation. Many orthopaedic surgeons traditionally do not allow their patients to weight bear for the first 6 weeks after surgery, fearing of loss of
The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability. We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score.Aims
Methods
The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing.Aims
Methods
The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors.Aims
Methods
Introduction. The sliding hip screw is the implant of choice for the operative treatment of stable trochanteric femur fractures. Surgeons have been using widely the four-hole side plate DHS (Dynamic Hip screw) with four bicortical screws, which allows adequate weight bearing after operation. However, there is lacking of scientific studies that support the use of such long plate and we question ourselves if we can accomplish the same results with the use of a smaller plate. The objective of this study is to compare the results accomplished with a four-hole and a two-hole DHS side plate in the treatment of transtrochanteric fractures. Material and Methods. This study included 140 patients (43 male and 97 female) that had stable transtrochanteric fractures between 1/01/2005 and 31/12/2008 and were submitted to osteossynthesis with DHS side-plate. 32 (22.9%) were treated with a two-hole DHS (group DHS2) and 108 (77.1%) with four-hole. The fractures were evaluated according to the AO/OTA classification and Evans for stability. The
To analyse the management of open paediatric tibial fractures treated at a children's Major Trauma Centre (MTC), comparing fixation methods, union and complications. We retrospectively identified all patients admitted to RMCH with an open tibia fracture between 2008 – 2016. Demographics, mechanism, inpatient stay and follow-up management were reviewed. There were a total of 44 patients, with an average age = 10 years (3–15). 93% of cases were caused by road traffic accidents, commonly pedestrian versus car. Older children were more likely to sustain higher grade injuries, requiring increased length of stay. 35 patients had primary / delayed wound closure, 1 patient required fasciotomies and 4/44 needed skin grafts and/or flap. 7 patients were treated in plaster, 9 by elastic nailing, 15 had mono-lateral fixators and 12 with circular frame. The average number of surgeries = 3 (1–7) with older children having increased risk of revision surgery. Monolateral fixators were the most common primary fixation method (n=15), however 60% required revision to ring fixator due to displacement or delayed union. The main risk factor for displacement was inadequate
PURPOSE. To evaluate the late radiographic and functional complications occurring after treatment of reverse oblique trochanteric fractures with the proximal femoral nail. PATIENTS. This is a retrospective study which was conducted between October 2004 and October 2009. 55 patients with a reverse oblique trochanteric fracture were treated with the Gamma 3 nail. According to the AO classification, there were 36 type AIII-1, 8 AIII-2, 11 AIII-3
The Gamma nail is frequently used in unstable
peri-trochanteric hip fractures. We hypothesised that mechanical failure
of the Gamma nail was associated with inadequate proximal three-point
fixation. We identified a consecutive series of 299 Gamma nails
implanted in 299 patients over a five-year period, 223 of whom fulfilled
our inclusion criteria for investigation. The series included 61
men and 162 women with a mean age of 81 years (20 to 101). Their fractures
were classified according to the Modified Evans’ classification
and the quality of
Calcaneal fracture fixation over the past decade has been practised via an extensile lateral incision. This can be complicated by infection and wound breakdown. We have developed a new technique for fixation of the calcaneal fractures – MACO. We utilise a 4 cm sub fibular incision to aid joint visualisation and