Aims. Global literature suggests that female surgical trainees have lower rates of independent operating (operative autonomy) than their male counterparts. The objective of this study was to identify any association between
For all the research into arthroplasty, provision of total knee arthroplasty (TKR) services based on
This qualitative study aims to explore and highlight the experiences of trainees in the Orthopaedic Surgical Education Training (SET) program in New Zealand, with a focus on identifying gender-specific biases which may impact professional development. Orthopaedic SET trainees in New Zealand were invited to complete a qualitative, semi-structured questionnaire exploring their experiences in the Orthopaedic SET program. A broad range of topics were covered, addressing culture, belonging, learning styles and role modelling. Recurrent themes were identified using inductive methods. Analysis of questionnaire responses identified several key themes for women in the Orthopaedic SET program, compared to their male counterparts, including (1) role incredulity, (2) confidence vs. competence, (3) adaptation, (4) interdisciplinary relationships and (5) role modelling. Female participants described experiencing
Distal radius fractures are the most common upper extremity fracture. The incidence is significantly higher in elderly females with osteoporotic bone. When surgery is indicated, volar locking plates (VLPs) allow for rigid fixation particularly in comminuted fractures with poor bone quality. Although numerous studies have shown the importance of plate placement to avoid soft tissue complications associated with volar plate fixation, there has been little evidence on the anatomic fit of current VLPs. Moreover, the effect of
Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the National Joint Registry (NJR), which covers England, Wales, Northern Ireland, the Isle of Man, and Guernsey. Secondary aims included comparing time since specialist registration, private practice participation, and number of hospitals worked in between male and female surgeons. Publicly available data from the NJR was extracted on the types of arthroplasty performed by each surgeon, and the number of procedures of each type undertaken. Each surgeon was cross-referenced with the General Medical Council (GMC) website, using GMC number to extract surgeon demographic data. These included sex, region of practice, and dates of full and specialist registration.Aims
Methods
End-stage ankle arthritis (ESAA) is a debilitating disease that does not affect all individuals equally.
For many patients, UKA is a good alternative to total knee arthroplasty (TKA) or high tibial osteotomy (HTO). Strong evidence that
Management of the pathologic long-head biceps tendon remains controversial. Biceps tenotomy is a simple intervention but may result in visible deformity and subjective cramping. Comparatively, biceps tenodesis is technically challenging, and has increased operative times, and a more prolonged recovery. The purpose of this study was to determine the incidence of popeye deformity following biceps tenotomy versus tenodesis, identify predictors for developing a deformity, and compare subjective and objective outcomes between those that have one and those that do not. Data for this study were collected as part of a randomized clinical trial comparing tenodesis versus tenotomy in the treatment of lesions of the long head of biceps tendon. Patients 18 years of age or older with an arthroscopy confirmed biceps lesion were randomized to one of these two techniques. The primary outcome measure for this sub-study was the rate of a popeye deformity at 24-months post-operative as determined by an evaluator blinded to group allocation. Secondary outcomes were patient reported presence/absence of a popeye deformity, satisfaction with the appearance of their arm, as well as pain and cramping on a VAS. Isometric elbow flexion and supination strength were also measured. Interrater reliability (Cohen's kappa) was calculated between patient and evaluator on the presence of a deformity, and logistic regression was used to identify predictors of its occurrence. Linear regression was performed to identify if age,
Introduction. Previous anthropometric studies have reported
The use of Patient Reported Outcome Measures (PROMS) has been critical to the success of total joint arthroplasty (TJA). They have made possible the evaluations of new implants, materials and surgical techniques that have been essential to the development of these technologies. PROMS have had a major impact on the decisions that surgeons make regarding treatment and care of patients. However, there are serious limitations of PROMS. They are useless in the first few weeks after surgery. They provide very little objective functional information to which health care providers can respond in the early, critical post-operative period. PROMS do not objectively measure specific outcome measures (e.g. ROM, distance walked). PROMS are also cumbersome and time consuming to use. Joint specific surface sensors are emerging to allow objective measurements of specific functional outcomes of knee surgery. This allows an examination of the factors that might affect these functional outcomes. The purpose of this study was to examine the relationship of age,
Introduction. Numerous fluoroscopic studies have been conducted to investigate kinematic variabilities of total knee arthroplasty (TKA). In those studies, subjects having a posterior stabilized (PS) TKA experience greater weightbearing knee flexion and posterior femoral rollback of the lateral condyle. In those same studies, subjects did experience a high incidence of variable medial condyle motion and reverse axial rotation, especially occurring when the cam engaged the post. More recently, a PS TKA was designed to accommodate both
Given their role in reducing anterior tibial translation, the recruitment patterns and viscoelastic properties of the hamstring muscles have been implicated as neuromuscular factors contributing to the ACL
Introduction:. Recent studies have concluded that
Total Knee Arthroplasty (TKA) has a tendency to change the individual anatomy of the patient within the limits of today used arthroplasty designs. Femoral external rotation will lead to mediolateral overhang by upsizing to avoid lateral notching and downsizing will lead to loss of posterior condylar offset. Posterior slope is usually reduced to avoid problems with posterior stabilized (PS) designs. We compared 50 bicompartimental arthroplasties (Uni + PFJ) with 50 TKA's. Demographics and BMI are compared. We looked specifically at patient type, preoperative deformity, postoperative function and alignment and results on functional scores. Bicompartimental arthroplasty is a resurfacing intervention that allows less correction of frontal deformity. Postop alignment was within 3° of varus. Better active flexion was obtained than in TKA. Better function was observed for stair climbing and single leg stability. Rotational position of foot was more natural in bicompartimental as compared to TKA. Functional scores like WOMAC, KOOS and IKDC showed better results for bicompartimental. Illness perception score showed that the resurfacing patient is another patient than the TKA patient. No overhang of components was observed. No change of posterior condylar offset was necessary. Posterior slope on the medial side was minimally reduced. In conclusion resurfacing by bicompartimental arthroplasty with two individual components (Uni + PFJ) is an excellent solution to
Introduction. Opponents of patellar resurfacing during Total Knee Arthroplasty (TKA) note unique complications associated with resurfacing. Problems include over-stuffing (the creation of a composite patellar-prosthesis thickness greater than the native patella) that may contribute to reduced range of motion; and creation of a patellar remnant that is too thin (in order to avoid over-stuffing) that may contribute to post-operative fracture. Factors including surgical technique, prosthesis design and patient anatomy may contribute to these problems. This study was performed to define the native patellar anatomy, and to compare the effect of differences in component thickness between manufacturers. Methods. This retrospective, IRB approved study reviewed 803 knees that underwent primary TKA between 2005 and 2011 with a single surgeon. Patellar resurfacing was performed with a round, polyethylene component from one of two different implant designs using the same surgical technique. Data recorded for each patient included:
Introduction. The use of screws is frequent for additional fixation, however, since some disadvantages have been reported a cup press-fit is desirable, although this can not always be obtained. Cup primary intraoperative fixation in uncemented total hip replacement (THR) depends on sex, acetabular shape, and surgical technique. We analyzed different factors related to primary bone fixation of five different designs in patients only diagnosed with osteoarthritis, excluding severe congenital hip disease and inflammatory arthritis, and their clinical and radiological outcome. Materials y Methods. 791 hips operated in our Institution between 2002 and 2012 were included for the analysis. All cases were operated with the same press-fit technique, and screws were used according to the pull-out test. Two screws were used if there was any movement after the mentioned manoeuvres. Acetabular and femoral radiological shapes were classified according to Dorr et al. We analyzed radiological postoperative cup position for acetabular abduction angle, the horizontal distance and the vertical distance. Cup anteversion was evaluated according to Widmer and the hip rotation centre according to Ranawat. Results. Screws were required in 155 hips (19.6%) and were more frequently used in women and patients with a type A acetabulum (p<0.001, p=0.021, respectively). There were no differences among the different cups evaluated. The need for screws was more frequent in hips with a smaller version of the cup and with a distance greater than 2 mm to the approximate femoral head centre from the centre of the prosthetic femoral head (p=0.022, 0.012, respectively). Adjusted multivariate analysis revealed that female patients (p<0.001, Odds Ratio (OR): 2.063; 95% Confidence Interval (CI) 1.409–3.020), cups with a smaller version (p=0.012, OR: 0.966, 95% CI 0.94–0.992), and a greater distance to the rotation hip center (p<0.005, OR: 1.695; 95% CI 1.173–2.450) had a higher risk for screw use. No hips needed revision for aseptic loosening. Conclusions. Cup press-fit depends on
Introduction. Uncemented press-fit cups provide bone fixation in primary total hip replacement (THR). However, sometimes screws are needed to achieve primary stability of the socket. We analyzed biomechanical factors related to press-fit in seven cup designs and assessed whether screw use provides similar loosening rates to those of the press-fit technique. Materials y Methods. From a series of 1,350 primary uncemented THRs using seven different press-fit cup designs (a dome loading hemispheric cup and bi- or tri- radius cups), we only analyzed the 889 diagnosed of primary osteoarthritis. All cases were operated by the same surgical team. The use of screws was decided intraoperatively based on cup stability according to the pull-out test. There were 399 female and 490 male patients with a mean age of 65 years old. The mean follow-up was 8.6 years (5–13 years). The reconstruction of the hip rotation center was evaluated according to Ranawat. Results. Screws were required in 223 (25.1%) of the surgeries: 35% of all dome-loaded cups and less frequently with other cup designs (range 18%-24%) (p<0.001) All hips showed good clinical results and radiological bone fixation. Screws were used more frequently in women (p<0.001). Adjusted multivariate analysis revealed that female patients (p<0.001, Odds Ratio (OR): 1.98; 95% Confidence Interval (CI) 1.34–2.95), hips with one of the hemispherical cup designs (p=0.01, OR: 2.51; 95% CI 1.33–5.33) and a greater distance to the rotation hip centre (p<0.001, OR: 1.25; 95% CI 1.15–1.35) had a higher risk for screw use. Every increase of 5 mm in this distance increased the risk of screw use by three (LI=2–4.5). Conclusions.
Introduction. Accurate alignment and sizing of the femoral component in total knee arthroplasty (TKA) is important for stability and functional outcomes. In relation to the shape of the distal femur, it has been reported that the medial-lateral (ML) femur width in women is narrower than that in men for the same antero-posterior (AP) length. In addition, it has been noted that the elevation of the anterior condyle in women is lower than that in men. Therefore, in TKA for women, it is suggested that a medial or lateral overhanging femoral component can cause pain or limit the range of motion (ROM). As a result, a gender-specific implant for women has been developed. However, there are few studies addressing the morphological dimensions of the distal shape of the femur in the Japanese population. The objective of this study was to reveal the appropriateness of using gender-specific implant for Japanese women. Methods. This study was based on 40 women (40 knees) and 40 men (40 knees) who had primary preoperative osteoarthritis of the knee. The average height was 161.2 cm for men and 149.4 cm for women. The average weight was 68.0 kg for men and 58.5 kg for women. These are significantly different. Resection of the distal femur for TKA was simulated with preoperative computed tomography (CT) data. The ML width on the anterior and distal cut surface, the ML width at the surgical epicondylar axis (SEA) level, the maximum AP length at the medial and lateral condyle, and the AP length after resection were measured. These values were compared between men and women, and compatibility with NexGen LPS-Flex and
Background. Recent anthropometric studies have suggested that current design of total knee arthroplasty (TKA) does not cater to racial anthropometric differences. The purpose of this study was to investigate the exact sizing and rotational landmarks of the distal femur collected and its
Humeral version is the twist angle of the humeral head relative to the distal humerus. Pre-operatively, it is most commonly measured referencing the transepicondylar axis, although various techniques are described in literature (Matsumura et al. 2014, Edelson 1999, Boileau et al., 2008). Accurate estimation of the version angle is important for humeral head osteotomy in preparation for shoulder arthroplasty, as deviations from native version can result in prosthesis malalignment. Most humeral head osteotomy guides instruct the surgeon to reference the ulnar axis with the elbow flexed at 90°. Average version values have been reported at 17.6° relative to the transepicondylar axis and 28.8° relative to the ulnar axis (Hernigou, Duparc, and Hernigou 2014), although it is highly variable and has been reported to range from 10° to 55° (Pearl and Volk 1999). These studies used 2D CT images; however, 2D has been shown to be unreliable for many glenohumeral measurements (Terrier 2015, Jacxsens 2015, Budge 2011). Three-dimensional (3D) modeling is now widely available and may improve the accuracy of version measurements. This study evaluated the effects of sex and measurement system on 3D version measurements made using the transepicondylar and ulnar axis methods, and additionally a flexion-extension axis commonly used in biomechanics. Computed tomography (CT) scans of 51 cadaveric shoulders (26 male, 25 female; 32 left) were converted to 3D models using medical imaging software. The ulna was reduced to 90° flexion to replicate the arm position during intra-operative version measurement. Geometry was extracted to determine landmarks and co-ordinate systems for the humeral long axis, epicondylar axis, flexion-extension axis (centered through the capitellum and trochlear groove), and ulnar long axis. An anatomic humeral head cut plane was placed at the head-neck junction of all shoulders by a fellowship trained shoulder surgeon. Retroversion was measured with custom Matlab code that analysed the humeral head cut plane relative to a reference system based on the long axis of the humerus and each elbow axis. Effects of measurement systems were analyzed using separate 1-way RM ANOVAs for males and females. Sex differences were analyzed using unpaired t-tests for each measurement system.Background
Methods