Anterior cruciate ligament (ACL)
Ligament reconstruction following multi-ligamentous knee injuries involves graft fixation in bone tunnels using interference screws (IS) or cortical suspensory systems. Risks of IS fixation include graft laceration, cortical fractures, prominent hardware, and inability to adjust tensioning once secured. Closed loop suspensory (CLS) fixation offers an alternative with fewer
Aims. The aim of this prospective study was to assess the long-term clinical, radiological, functional, and quality of life (QoL)-related outcome of patients treated with the synthetic Ligament Advanced Reinforcement System (LARS) device for anterior cruciate ligament (ACL) rupture. Methods. A total of 41 patients who underwent ACL reconstruction with the LARS device (mean age 39.8 years (SD 12.1 ); 32% females (n = 13)) were prospectively included between August 2001 and March 2005. MRI scans and radiographs were performed at a median follow-up of 2.0 years (interquartile range (IQR) 1.3 to 3.0; n = 40) and 12.8 years (IQR 12.1 to 13.8; n = 22). Functional and QoL-related outcome was assessed in 29 patients at a median follow-up of 12.8 years (IQR 12.0 to 14.0) and clinically reconfirmed at latest median follow-up of 16.5 years (IQR 15.5 to 17.9). International Knee Documentation Committee (IKDC) and Tegner scores were obtained pre- and postoperatively, and Lysholm score postoperatively only. At latest follow-up, range of motion, knee stability tests, 36-Item Short Form Health Survey (SF-36), and IKDC scores were ascertained. Complications and reoperations during follow-up were documented. Results. Cumulative complication rate was 66% (n = 27), with 11 developing within one year from surgery and 16 after one year (including five patients with both early and late complications). Ten
Abstract. Background. The gold standard treatment for Anterior Cruciate Ligament injury is reconstruction (ACL-R).
Abstract. Aims. Growth disturbances after transphyseal paediatric ACL reconstruction have led to the development of physeal-sparing techniques. However, evidence in their favour remains weak. This study reviews the literature to identify factors associated with growth disturbances in paediatric ACL reconstructions. Materials and Methods. Web of Science, Scopus and Pubmed were searched for case series studying paediatric ACL reconstructions. Titles, abstracts, text, results and references were examined for documentation of growth disturbances. Incidences of
Abstract. Background. The gold standard treatment for Anterior Cruciate Ligament injury is reconstruction (ACL-R). Graft augmentation with suture tape (internal brace) are techniques purported to reduce the risk of rupture and hasten recovery. Our aim was to assess the short-term outcome of ACL-R using fibre tape augmented and non-augmented hamstring tendon grafts. Methods. This was a retrospective comparative study looking at augmented and non-augmented ACL-R. All procedures were performed by a single surgeon in a single centre using the same technique. The Knee injury and Osteoarthritis Outcome Score [KOOS] was used to assess patient-reported outcomes. Results. There were 72 patients in the augmented and 132 patients in the control group. Confounding factors were comparable in both groups. The mean graft diameter in the augmented group was 8.81mm versus 8.01mm in the non-augmented. Six strand graft was achievable in 71% of the augmented group compared to 62.5% in the non-augmented group. Two
The bone-patellar tendon-bone (BTB) autograft has a lower rate of
The aim of the this study was to determine the effect of the knee flexion angle (KFA) during tibial anterior cruciate ligament (ACL) graft fixation on patient reported outcomes, graft stability, extension loss and re-operation following anatomic single-bundle ACL reconstruction. All 169 included patients (mean age 28.5 years, 65% male) were treated with anatomic single bundle ACL reconstruction using patellar tendon autograft and randomized to tibial fixation of the ACL graft at either 0o (n=85) or 30o (n=84). The primary outcome was the Knee Injury and Osteoarthritis Outcome Score (KOOS) two years following surgery. Secondary outcomes were the Marx Activity Scale (MAS), the rate of re-operation, and physical exam findings at one year including KT-1000 and side to side differences in knee extension. The follow-up rate was 82% (n=139) for the primary outcome.
Introduction. It has been contentious whether an anatomic double-bundle technique for anterior cruciate ligament reconstruction (ACLR)is superior to that of a single-bundle technique. It has been hypothesized in the literature that the double-bundle technique could provide function closer to that of the anatomical knee joint. The purpose of this study was to compare the long-term clinical outcomes after single-bundle ACLR versus double-bundle ACLR. We hypothesized that the double-bundle technique would not be superior to the single-bundle technique. Methods. A retrospective, non-randomized, matched-paired comparative study was performed. Patients undergoing primary anterior cruciate ligament reconstruction, using either a double-bundle or single-bundle technique, between 2003 and 2008 were included and matched 1:1. Matching included age, sex, BMI, time from injury to surgery, side of injury and type of sport. Patients who underwent revision procedures, multiligament reconstruction or other ACLR techniques were excluded. Patients were subsequently followed up, noting occurrence of graft rupture and any other complications. Results. A total of 1377 ACLRs were performed during the study period. Seven hundred and fifty-six patients were excluded, leaving 396patients to be included in the matching (198 matched pairs). Mean follow-up time was 176.7 +/− 7.7 months (range, 166–211 months). Overall, 40 patients (10.1%) suffered from a graft rupture which consisted of 22 patients (11.1%) in the single-bundle group and 18patients (9.1%) in the double-bundle group. A multivariate analysis was performed using the Cox model and demonstrated that
The primary purpose of this study was to assess whether patients presenting with clinical graft laxity following primary anatomic anterior cruciate ligament (ACL) reconstruction using hamstring autograft reported a significant difference in disease-specific quality-of-life (QOL) as measured by the ACL-QOL questionnaire. Clinical ACL graft laxity was assessed in a cohort of 1134/1436 (79%) of eligible patients using the Lachman and Pivot-shift tests pre-operatively and at 12- and 24-months following ACL reconstruction. Post-operative ACL laxity was assessed by an orthopaedic surgeon and a physical therapist who were blinded to each other's examination. If there was a discrepancy between the clinical examination findings from these two assessors, then a third impartial examiner assessed the patient to ensure a grading consensus was reached. Patients completed the ACL-QOL questionnaire pre-operatively, and 12- and 24-months post-operatively. Descriptive statistics were used to assess patient demographics, rate of post-operative ACL graft laxity, surgical failures, and ACL-QOL scores. A Spearman rho correlation coefficient was utilised to assess the relationships between ACL-QOL scores and the Lachman and Pivot-shift tests at 24-months post-operative. An independent t-test was used to determine if there were differences in the ACL-QOL scores of subjects who sustained a
The Adams-Berger reconstruction is an effective technique for treating distal radioulnar joint (DRUJ) instability. Graft preparation techniques vary amongst surgeons with insufficient evidence to support one technique over another. Our study evaluated the biomechanical properties of four graft preparation techniques. Extensor tendons were harvested from fresh frozen porcine trotters obtained from a local butcher shop and prepared in one of three configurations (n=5 per group): tendon only; tendon prepared with non-locking, running suture (2-0 FiberLoop, Arthrex, Naples, FL) spaced at 6 mm intervals; and tendon prepared with suture spaced at 12 mm intervals. A fourth configuration of suture alone was also tested. Tendons were allocated in a manner to ensure comparable average diameters amongst groups. Biomechanical testing occurred using custom jigs simulating radial and ulnar tunnels attached to a Bose Electroforce 3510 mechanical testing machine (TA Instruments). After being woven through the jigs, all tendons were sutured end-to-end with 2-0 PROLENE suture (Ethicon). Tendons then underwent a staircase cyclic loading protocol (5-25 Newtons [N] at 1 hertz [Hz] for 1000 cycles, then 5-50 N at 1 Hz for 1000 cycles, then 5-75 N at 1 Hz for 1000 cycles) until
Abstract. Introduction. High posterior tibial slope (PTS) has been recognised as a risk factor for anterior cruciate ligament rupture and
Aims. The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function. Patients and Methods. We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score. Results. A total of 14 grafts (23.3%) failed at a mean of 8.6 years (1.4 to 20.1). Graft survivorship was 87.3% (95% confidence interval (CI) 79.0 to 96.6), 85.0% (95% CI 75.8 to 95.3), 74.8% (95% CI 62.2 to 90.0), 65.2% (95% CI 49.9 to 85.2), and 59.8% (95% CI 43.5 to 82.1) at five, ten, 15, 20, and 25 years, respectively. A total of 23 patients (38.3%) developed complications, and 26 (43.3%) had a further operation. Persistent postoperative malalignment occurred more frequently in failed grafts (28.6% vs 4.3%; p = 0.023), and was a risk factor for
Abstract. Introduction. Anterolateral procedures can reduce the risk of re-rupture after ACL reconstruction in high risk patients however, this effectiveness has never been evaluated in elite athletes. The purpose of this study was to evaluate the effectiveness of lateral extra-articular tenodesis in reducing revision rates in ACL reconstructions in elite athletes. Methodology. A consecutive cohort of elite athletes between 2005 and 2018 undergoing ACLR reconstruction with or without modified Lemaire lateral extra-articular tenodesis were analysed. A minimum of 2 years of follow-up was required. The association between the use of LET and ACL graft failure was evaluated with univariate and multivariate logistic regression models. Results. 455 elite athletes (83% male; 22.5±4.7 years) underwent primary ACL reconstruction with (n=117) or without (n=338) a LET procedure. Overall, 36 athletes (7.9%) experienced ACL graft failure including 32 (9.5%) reconstructions without a LET and 4 (3.4%) with a LET. Utilization of LET during primary ACL reconstruction reduced the risk of
The goal of this study was to identify the effect of mismatches in the subchondral bone surface at the native:graft interface on cartilage tissue deformation in human patellar osteochondral allografts (OCA). Hypothesis: large mismatches in the subchondral bone surface will result in higher stresses in the overlying and surrounding cartilage, potentially increasing the risk of
Abstract. Introduction. We present a case series of patients that underwent knee ligament reconstruction with graft reinforcement using FibreTape (Arthrex), a 2mm wide non-biodegradable polyethylene tape. Outcomes and safety of this novel technique are reported. Methods. Data were collected from a prospectively maintained database from 03/2011 to 11/2019. All skeletally mature patients that underwent reinforced knee ligament reconstruction surgery at Basingstoke and North Hampshire Hospital were included. The cohort was interrogated for outcomes including failure, complications, and subjective patient reported outcomes at 6,12 and 24 months postoperatively. Results. 438 patients were eligible. The mean age was 33.4 years and 68% of them were males. This included 171 ACL reconstructions, 96 ACL with anterolatreal ligament reconstructions, 59 bicruciate reconstructions, 30 ACL with posterolateral corner, 49 posterior cruciate ligament with one other ligament and 33 other ligament reconstruction. Allograft was used for 125 patients. 338 cases related to primary reconstruction. The overall complication rate was 5.3%, with a 2.1% re-rupture rate. There were 9 patients with a re-rupture and 5 of them had undergone multiligament reconstruction. We found a statistically significant improvement in all subjective scoring indices post-operatively up to 2 years. There were no complications directly related to the use of ligament reinforcement. Conclusion. Graft reinforcement is a safe option in the management of knee ligament injuries. Encouraging results were observed in patient reported outcomes. Reinforcement is technically reproducible and may represent an answer for
Abstract. Methodology. Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. 76 cases (mean age of 33.2 years) who had primary ACL reconstruction with BTB or quadriceps tendon with bone block, were divided into 2 matched groups (age, sex and type of graft) of 38 each based on the method of femoral fixation used (interference screw or adjustable cortical suspension). Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Complications and return to theatre were noted. Paired two-tailed student t-tests and Chi-square tests were employed for statistical analysis. Results. At a mean follow-up of 82 months, peri-operative mean EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.05), but no significant difference between the two groups (p>0.05). Mean graft length and diameter was 77mm and 9.3 respectively. Mean interval from injury to surgery was 10.5 months. 18(23.7%) patients had associated meniscal tear with 73.3 % undergoing repair. 10 cases (13.2 %) returned to theatre including, MUA for arthrofibrosis (n=2) and intra-substance
To document and assess the available evidence regarding single bundle, hamstrings autograft preparation techniques for Anterior Cruciate Ligament reconstruction (ACLR) and provide graft preparation options for different clinical scenarios. Three online databases (Embase, PubMed and Ovid [MEDLINE]) were searched from database inception until April 10, 2021. The inclusion criteria were English language studies, human studies, and operative technique studies for single bundle hamstrings autograft preparation for ACLR. Descriptive characteristics, the number of tendons, number of strands, tendon length, graft length and graft diameter were recorded. The methodological quality was assessed using the Methodological Index for Non-Randomized Studies (MINORS) instrument and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system for non-randomized and randomized studies, respectively. The initial search yielded 5485 studies, 32 met the inclusion criteria. The mean MINORS score across all nonrandomized studies was 8.2 (standard deviation, SD 6.6) indicating an overall low quality of evidence. The mean MINORS score for comparative studies was 17.4 (SD 3.2) indicating a fair quality of evidence. The GRADE assessment for risk of bias in the randomized study included was low. There were 2138 knees in 1881 participants, including 1296 (78.1%) males and 363 (21.9%) females recorded. The mean age was 30.3 years. The mean follow-up time was 43.9 months when reported (range 16-55 months). Eleven studies utilized the semitendinosus tendon alone, while 21 studies used both semitendinosus and gracilis tendons. There were 82 (3.8%) two-strand grafts, 158 (7.4%) three-strand grafts, 1044 (48.8%) four-strand grafts, 546 (25.5%) five-strand grafts, and 308 (14.4%) six-strand grafts included. Overall, 372 (19.7%) participants had a single-tendon ACLR compared to 1509 (80.2%) participants who had a two-tendon ACLR. The mean graft diameter was 9.4mm when reported. The minimum semitendinosus and gracilis tendon lengths necessary ranged from 210-280mm and 160-280mm respectively. The minimum graft length necessary ranged from 63-120mm except for an all-epiphyseal graft in the paediatric population that required a minimum length of 50mm. The minimum femoral, tibial, and intra-articular graft length ranged from 15-25mm, 15-35mm and 20-30mm respectively. Thirteen studies detailed intra-operative strategies to increase graft size such as adding an extra strand or altering the tibial and/or femoral fixation strategies to shorten and widen the graft. Two studies reported ACL reinjury or
Abstract. Shoulder replacements have evolved and current 4th generation implants allow intraoperative flexibility to perform anatomic, reverse, trauma, and revision shoulder arthroplasty. Despite high success rates with shoulder arthroplasty, complication rates high as 10–15% have been reported and progressive glenoid loosening remains a concern. Objectives. To report medium term outcomes following 4th generation VAIOS® shoulder replacement. Methods. We retrospectively analysed prospectively collected data following VAIOS® shoulder arthroplasty performed by the senior author between 2014–2020. This included anatomical (TSR), reverse(rTSR), revision and trauma shoulder replacements. The primary outcome was implant survival (Kaplan-Meier analysis). Secondary outcomes were Oxford Shoulder Scores (OSS), radiological outcomes and complications. Results. 172 patients met our inclusion criteria with 114 rTSR, 38 anatomical TSR, and 20 hemiarthroplasty. Reverse TSR- 55 primary, 31 revision, 28 for trauma. Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Trauma rTSR-Average post-operative OSS was 31.4 Anatomical TSR38 patients underwent primary anatomical TSR, 8 were revisions following hemiarthroplasty. In 16/38 patients, glenoid bone loss was addressed by bone grafting before implantation of the metal back glenoid component. Mean age at time of surgery was 68.3 years (53 – 81 years). Mean follow-up was 34 months (12 – 62 months). The average Oxford shoulder score improved from 14 (7–30) to 30 (9–48). There were 3 revisions (7.8%); two following subscapularis failure requiring revision conversion to reverse shoulder replacement and one for glenoid