Pelvic bone defect in patients with severe congenital dysplasia of the hip (CDH) lead to abnormalities in lumbar spine and lower limb alignment that can determine total hip arthroplasty (THA) patients' outcome. These variables may be different in uni- or bilateral CDH. We compared the clinical outcome and the spinopelvic and lower limb radiological changes over time in patients undergoing THA due to uni- or bilateral CHD at a minimum follow-up of five years. Sixty-four patients (77 hips) undergoing THA due to severe CDH between 2006 and 2015 were analyzed: Group 1 consisted of 51 patients with unilateral CDH, and group 2, 113 patients (26 hips) with bilateral CDH. There were 32 females in group 1 and 18 in group 2 (p=0.6). The mean age was 41.6 years in group 1 and 53.6 in group 2 (p<0.001). We compared the hip, spine and knee clinical outcomes. The radiological analysis included the postoperative
Results in patients undergoing total hip arthroplasty (THA) for femoral head osteonecrosis (ON) when compared with primary osteoarthritis (OA) are controversial. Different factors like age, THA type or surgical technique may affect outcome. We hypothesized that patients with ON had an increased revision rate compared with OA. We analysed clinical outcome, estimated the survival rate for revision surgery, and their possible risk factors, in two groups of patients. In this retrospective cohort analysis of our prospective database, we assessed 2464 primary THAs implanted between 1989 and 2017. Patients with OA were included in group 1, 2090 hips; and patients with ON in group 2, 374 hips. In group 2 there were more men (p<0.001), patients younger than 60 years old (p<0.001) and with greater physical activity (p<0.001). Patients with lumbar OA (p<0.001) and a radiological acetabular shape type B according to Dorr (p<0.001) were more frequent in group 1. Clinical outcome was assessed according to the Harris Hip Score and radiological analysis included postoperative acetabular and femoral component position and
Total hip replacement (THR) in young patients has been associated to higher revision rates than in older population. Different conditions may lead to end-stage arthritis of the hip in these patients. We compared the clinical and radiological outcome of two different groups of young and very young patients who underwent a ceramic-on-ceramic THR. 120 hips were prospectively followed for a mean of 10.4 years (range, 5 to 17). 38 patients (46 hips) were less than 30 years old (group 1), and, 68 (74 hips) were between 31 and 40 years old (group 2). Weight (p<0.001) and physical activity level were greater in group 2 (p<0.001). Preoperative function (p=0.03) and range of mobility (p=0.03) were worse in group 1. Primary osteoarthritis was not found in any case. Rheumatoid juvenile arthritis was the most frequent diagnosis in group 1 and avascular necrosis of the femoral head in group 2. A femoral funnel-shaped type 1 according to Dorr was more frequent in group 2 (p=0.04). The same ceramic-on-ceramic uncemented THR was used in all cases. Screws for cup fixation were only used when strictly needed. We analysed the clinical results according to the Merle-D´Aubignè and Postel scale, the postoperative radiological
Although cemented fixation provides excellent results in primary total hip replacement (THR), particularly in patients older than 75 years, uncemented implants are most commonly used nowadays. We compare the rate of complications, clinical and radiological results of three different designs over 75-years-old patients. 433 hips implanted in patients over 75 years old were identified from our Local Joint Registry. Group A consisted of 139 tapered cemented hips, group B of 140 tapered grit-blasted uncemented hips and group C of 154 tapered porous-coated uncemented hips. A 28 mm femoral head size on polyethylene was used in all cases. The mean age was greater in group A and the physical activity level according to Devane was lower in this group (p<0.001 for both variables). Primary osteoarthritis was the most frequent diagnoses in all groups. The radiological acetabular shape was similar according to Dorr, however, an osteopenic-cylindrical femur was most frequently observed in group A (p<0.001). The pre- and post-operative clinical results were evaluated according to the Merle-D'Aubigne and Postel scale. Radiological cup position was assessed, including hip rotation centre distance according to Ranawat and cup anteversion according to Widmer. We also evaluated the lever arm and height of the greater trochanter distances and the stem position. Kaplan-Meier analysis was done for revision for any cause and loosening. The hip rotation centre distance was greater and the height of the greater trochanter was lower in group B (p=0.003, p<0.001, respectively). The lever arm distance was lower in group C (p<0.001). A varus stem position was more frequently observed in group B (p<0.001). There were no intra- or post-operative fractures in group A, although there were five intra-operative fractures in the other groups plus two post-operative fractures in group B and four in group C. The rate of dislocation was similar among groups and was the most frequent cause for revision surgery (8 hips for the whole series). The mean post-operative clinical score improved in all groups. The overall survival rate for revision for any cause at 120 months was 88.4% (95% CI 78.8–98), being 97.8% (95% CI 95.2–100) for group A, 81.8% (95% CI 64.8–98.8) for group B and 95.3% (95% CI 91.1–99.6) for group C (log Rank: 0.416). Five hips were revised for loosening. The overall survival rate for loosening at 120 months was 91.9% (95% CI 81.7–100), being 99.2%(95% CI 97.6–100) for group A, 85.5 (95% CI 69.9 −100) for group B and 100% for group C (Log Rank 0.093). Despite a more osteopenic bone in the cemented group, the rate of peri-prosthetic fractures was higher after uncemented THR in patients older than 75 years. Although the overall outcome is good with both types of fixation, the post-operative
Introduction. We present our experience of the coned hemi-pelvis (‘ice-cream’ cone) implant, using an extended posterior approach to the hip joint, in the management of pelvic bone loss and pelvic discontinuity. Methods. Retrospective study conducted utilising a prospectively collected database. Patients who underwent an ice-cream cone reconstruction between August 2004 – September 2011 were identified. All had a posterior approach to the hip. Femur prepared in the standard fashion. A variety of femoral components used. Demographic data was recorded along with the indication for surgery and outcomes. Results. 16 patients identified. Mean age was 62.2 years. 5 (31.25%) male. 11 (69.75%) female. Indications included; multiple hip revision surgery 4(25%); post Gridlestones for severe hip dysplasia 1 (6.25%); peri-acetabular metastatic deposits 11 (68.75%) from breast, renal, endometrial, prostatic, myeloma primary malignancies. Mean follow-up was 32.06 months. Complications; 1 intra-operative death from tumour embolus; 1 dislocation; 1 superficial surgical site infection. 3 deaths from their primary malignancy. Mean time from prosthesis implantation to death was 14.5 months. All patients at last follow-up were mobilizing. No implant has needed to be revised. Discussion. Pelvic bone loss provides reconstructive challenges. The coned hemi-pelvis is simple to make, easy and versatile to use even when there is little pelvis remaining. It provides a method of negotiating
Summary. Micromotions between stem and neck adapter depend on prosthesis design and material coupling. Based on the results of this study, the amount of micromotion seems to reflect the risk of fretting-induced fatigue in vivo. Introduction. Bimodular hip prostheses were developed to allow surgeons an individual
The period of post-operative treatment before surgical wounds
are completely closed remains a key window, during which one can
apply new technologies that can minimise complications. One such
technology is the use of negative pressure wound therapy to manage
and accelerate healing of the closed incisional wound (incisional
NPWT). We undertook a literature review of this emerging indication
to identify evidence within orthopaedic surgery and other surgical
disciplines. Literature that supports our current understanding
of the mechanisms of action was also reviewed in detail. Objectives
Methods
The Capital Hip implant was a Charnley-based system which included a flanged and a roundback stem, both of which were available in stainless steel and titanium. The system was withdrawn from the market because of its inferior performance. However, all four of the designs did not produce poor rates of survival. Using a simulated-based, finite-element analysis, we have analysed the Capital Hip system. Our aim was to investigate whether our simulation was able to detect differences which could account for the varying survival between the Capital Hip designs, thereby further validating the simulation. We created finite-element models of reconstructions with the flanged and roundback Capital Hips. A loading history was applied representing normal walking and stair-climbing, while we monitored the formation of fatigue cracks in the cement. Corresponding to the clinical findings, our simulation was able to detect the negative effects of the titanium material and the flanged design in the Capital Hip system. Although improvements could be made by including the effect of the roughness of the surface of the stem, our study increased the value of the model as a predictive tool for determining failure of an implant.