Reverse Total shoulder arthroplasty (RTSA) was initially introduced to treat rotator cuff arthropathy. With proven successful long-term outcomes, it has gained a noteworthy surge in popularity with its indications consequently being extended to treating various traumatic glenohumeral diseases. Several countries holding national registries remain a guide to the use the prosthesis, however a notable lack of epidemiological data still exists. More so in South Africa where the spectrum of
Aim. Reveal the rate of surgical site infection (SSI) after primary hip and knee arthroplasty in patients with inflammatory
Dynamic 2D sonography of the infant hip is a commonly used clinical procedure for developmental dysplasia of the hip (DDH) screening. It however has been found to be unreliable with some studies reporting associated misdiagnosis rates of up to 29%. In a recent systematic review, Charlton et al. examined dynamic ultrasound (US) screening for hip instability in the first six weeks after birth and found current best practices for such early screening techniques to be divergent between international institutions in terms of clinical scanning protocols. Such protocols include: the appropriate scanning plane and US probe position (e.g. coronal, transverse, lateral, anterior), DDH diagnostic metrics (e.g. femoral head coverage, alpha angle), appropriate patient age when scanning, and follow up procedures. To improve reliability of diagnosis and to help in standardizing diagnosis across different raters and health-centers, we propose an automated method for dynamically assessing hip instability using 3D US. 38 infant hips from 19 patients were scanned with B-mode 3D US by a paediatric orthopaedic surgeon and two technologists from the radiology department at a paediatric tertiary care centre. To quantify hip assessment, we proposed the use of femoral head coverage variability (ΔFHC3D) within 3D US volumes collected during a sequence of US scans (one at rest, and another with posterior stress applied to the joint as maneuvered during a dynamic assessment). We used phase symmetry image features to localize the ilium's vertical cortex and a random forest classifier to identify the location of the femoral head. The proposed ΔFHC3D provided good repeatability with an average test-retest ICC measure of 0.70 (95% confidence interval: 0.35 to 0.87, F(21,21) = 7.738, p<.001). The mean difference of ΔFHC3D measurements was 0.61% with a SD of 4.05%. Since the observed changes in ΔFHC3D start near 0% and range up to about 18% from stable to mildly unstable hips in this cohort, the mean difference and standard deviation of ΔFHC3D measurements observed suggest that the proposed metric and technique likely have sufficient resolution and repeatability to quantify differences in hip laxity. The long-term significance of this approach to evaluating dynamic assessments may lie in increasing early diagnostic accuracy in order to prevent dysplasia remaining undetected prior to manifesting itself in early adulthood
Septic arthritis is a medical emergency that can lead to significant morbidity and mortality arising from irreversible joint destruction and overwhelming sepsis. The purpose of this prospective study is to present epidemiological, clinical and laboratory findings in adult patients with septic arthritis. Adult patients treated for septic arthritis at the Department of Infectious Diseases, University Medical Centre Ljubljana, Slovenia, from January 2012 to December 2014, qualified for the present report. The following data were analyzed: age, sex, underlying diseases, previous joint procedure, microbiological diagnostic examinations, causative agents, complications and therapy. During the study period of three years 94 episodes of septic arthritis were diagnosed. There were 49 (52.1%) females and 45 (47.9%) males, aged 64.5 (18 to 97) years. At the first visit elevated concentration of C-reactive protein was found in 93 (98.9%) patients. The most common affected joint was knee (48.9%), followed by shoulder (20.2%), wrist (12.8%), ankle (7.4%) and others. In 8 (8.5%) patients more than one joint was affected. Risk factors were found in 63 (67%) of study patients. The underlying
Osteoarthritis (OA) is a debilitating disease and the most common
Osteoarthritis (OA) is one of the most prevalent
Introduction. Osteoarthritis (OA), a painful, debilitating
Although physical and ultrasound (US)-based screening for congenital deformities of the hip (developmental dysplasia of the hip, or DDH) is routinely performed in most countries, one of the most commonly performed manoeuvres done under ultrasound observation - dynamic assessment - has been shown to be relatively unreliable and is associated with significant misdiagnosis rates, on the order of 29%. Our overall research objective is to develop a quantitative method of assessing hip instability, which we hope will standardise diagnosis across different raters and health-centres, and may perhaps improve reliability of diagnosis. To quantify dynamic assessment, we propose to use the variability in femoral head coverage (FHC) measurements within multiple US scans collected during a dynamic assessment. In every US scan, we use our recently-developed automatic FHC measuring tool which leverages phase symmetry features to approximate vertical cortex of ilium and a random forest classifier to identify approximate location of the femoral head. Having estimated FHC in each scan, we estimate the change in FHC across all the US scans during a dynamic assessment and compare this change with variability of FHC found in previous studies. Our findings - in a dynamic assessment on an infant done by an orthopaedic surgeon, the femoral centre moved by up to 19% of its diameter during distraction, from 55% FHC to 74% FHC. This variability is similar to the variability of FHC in static US scans reported in previous studies, so the variability in FHC readings we found are not indicative of any subluxation or dislocation of the infant's femoral head. Our clinician's qualitative assessment concluded the hip to be normal and not indicative of instability. This suggests that our technique likely has sufficient resolution and repeatability to quantify differences in laxity between stable and unstable hips, although this presumption will have to be confirmed in a subsequent study with additional subjects. The long-term significance of this approach to evaluating dynamic assessments may lie in increasing early diagnostic sensitivity in order to prevent dysplasia remaining undetected prior to manifesting itself in early adulthood
Objective. This study shows the radiographic results of total hip arthroplasty (THA) using the Revelation hip system. ®. for hip
Total knee arthroplasty (TKA) is widely accepted as a successful treatment option for the pain and limitation of function associated with severe
Intro. Across much of medicine, activity levels predict life expectancy, with low levels of activity being associated with increased mortality, and higher levels of activity being associated with longer healthier lives. Resurfacing is a technically demanding procedure that has suffered significant fallout from the failure of a couple of poorly performing designs. However strong evidence associates resurfacing with improved life expectancy in both the short and longer term following surgery. We wondered if there was any relationship between the function of hips following surgery and the extent of that surgery. Could a longer stem inside the femur be the reason for a slightly reduced step length? We proposed the nul hypothesis that there was no clinically relevant difference between stem length and gait. Method. After informed consent each subject was allowed a 5 minute acclimatisation period at 4km/hr on the instrumented treadmill (Kistler Gaitway, Amherst, NY). Their gait performance on an increasing incline at 5, 10 and 15%. At all 0.5km incremental intervals of speed, the vertical component of the ground reaction forces, center of pressure and temporal measurements were collected for both limbs with a sampling frequency of 100Hz over 10sec. They were also asked to log onto our JointPRO website and report their function using Oxford, EQ5D, and Imperial scores. Owing to current restrictions in indications, the patient groups selected were not comparable. However, from our database of over 800 patients who have been through the gait lab. 82 subjects were tested from 2 diagnostic groups (29 conventional THR, 27 hip resurfacing) and compared with a slightly younger group of 26 healthy controls. Patients were excluded if less than 12 months postop, or with any other documented
Introduction. Financial and human cost effectiveness is an increasing evident outcome measure of surgical innovation. Considering the human element, the aim is to restore the individual to their “normal” state by sparing anatomy without compromising implant performance. Gait lab studies have shown differences between different implants at top walking speed, but none to our knowledge have analysed differing total hip replacement patients through the entire range of gait speed and incline to show differences. The purpose of this gait study was to 1) determine if a new short stem femoral implant would return patients back to normal 2) compare its performance to established hip resurfacing and long stem total hip replacement (THR) implants. Method. 110 subjects were tested on an instrumented treadmill (Kistler Gaitway), 4 groups (short-stem THR, long-stem THR, hip resurfacing and healthy controls) of 28, 29, 27, and 26 respectively. The new short femoral stem patients (Furlong Evolution, JRI) were taken from the ongoing Evolution Hip trial that have been tested on the treadmill minimum 12months postop. The long stem total hip replacements and hip resurfacing groups were identified from our 800+ patient treadmill database, and only included with tests minimum 12 months postop and had no other
Introduction. Early hip OA may be attributed to smaller coverage of the femoral head leading to higher loads per unit area. We hypothesize that tight hamstrings may contribute to increased loads per unit area on the femoral head during gait. When a patient has tight hamstrings they cannot flex their pelvis in a normal fashion which may result in smaller coverage of the femoral head (Figure 1). This study aimed to determine if subjects with tight hamstrings can improve femoral head coverage during gait after a stretching intervention. Methods. Nine healthy subjects with tight hamstrings (popliteal angle>25°) were recruited and consented for this IRB approved study. Gait analysis with 58 reflective markers were placed by palpation on anatomical landmarks of the torso and lower extremities. Ten optoelectronic cameras (Qualisys, Gothenburg, Sweden) and three force plates (AMTI, Watertown, MA) were used to track marker position and measure foot strike forces. Subjects walked at a self-selected speed across the force plates until ten clean trials were performed and then were scanned with the reflective markers on the spine using an EOS (EOS Imaging, France) bi-planar x-ray system. Following testing participants completed a six week stretching program to increase hamstring length. Pelvic tilt (PT) was measured at heel strike for each trial and averaged. Using EOS scans the femoral head radius was measured using three points that best fit the load bearing surface on the sagittal view from the anterior acetabular rim to a point on the posterior acetabulum 45 degrees from vertical. The radius of femoral head and angle of acetabular coverage were used to calculate the load bearing surface area of femoral head. Load on the femur was calculated using an Anybody lower body model (Anybody Technology, Aalborg, Denmark) and load per unit area change was compared. Results. Nine participants completed the stretching program and post intervention testing. PA increased in all subjects (mean ± SD) 18.8° ± 11° (p<.01). Eight of nine subjects had an increase in anterior PT at heel strike resulting in a mean change of 2.1° ± 2.9° (p<.05). The change in PT resulted in a mean surface area change of 0.63cm. 2. ± 0.77 cm. 2. (p<.05), which resulted in a mean pressure change of −57.9MPa ± 55.7MPa. Removing the one subject who decreased in anterior pelvic tilt resulted in a mean change in PT of 2.9° ± 1.2°, a mean change in surface area of 0.85cm. 2. ± 0.46 cm. 2. , and a mean pressure change of −74.4 MPa ± 27.2 MPa. (Table 1). Discussion/Conclusion. This study verified the hypothesis that functional PT is influenced significantly by tight hamstrings. Using a stretching intervention program small changes in functional PT can be elicited that may significantly decrease the force per unit area on the femoral head and possibly the risk for developing degeneration
Introduction. Total hip replacement is an established surgical procedure done to alleviate hip pain due to
Artificial joints have been increasingly used in the treatment of physically disabled people who suffer from
This study shows the radiographic results of total hip arthroplasty (THA) using Revelation stem ® (Djo surgical USA) for hip
The gold standard for measuring knee alignment is the lower limb mechanical axis. This is traditionally assessed by weight-bearing full length lower limb X-rays (LLX). CT scanograms (CTS) are however, becoming increasingly popular in view of lower radiation exposure, speed and supine positioning. We assessed the correlation and reproducibility of knee joint coronal alignment using these two imaging modalities. LLX and CTS images were obtained in 24 knees with degenerate
Introduction. Patellar stability is an important component for a correct kinematic behaviour of the knee that depends on several factors such as joint geometry, muscles strength and soft tissues actions. Patellofemoral (PF) maltracking can results in many
Total knee replacement (TKR) is an established treatment for end stage
INTRODUCTION. Understanding bone morphology is essential for successful computer assisted orthopaedic surgery, where definition of normal anatomical variations and abnormal morphological patterns can assist in surgical planning and evaluation of outcomes. The proximal femur was the anatomical target of the study described here. Orthopaedic surgeons have studied femoral geometry using 2D and 3D radiographs for precise fit of bone-implant with biological fixation. METHOD. The use of a Statistical Shape Model (SSM) is a promising venue for understanding bone morphologies and for deriving generic description of normal anatomy. A SSM uses measures of statistics on geometrical descriptions over a population. Current SSM construction methods, based on Principal Component Analysis (PCA), assume that shape morphologies can be modeled by pure point translations. Complicated morphologies, such as the femoral head-neck junction that has non-rigid components, can be poorly explained by PCA. In this work, we showed that PCA was impotent for processing complex deformations of the proximal femur and propose in its place our Principal Tangent Component (PTC) analysis. The new method used the Lie algebra of affine transformation matrices to perform simple computations, in tangent spaces, that corresponded to complex deformations on the data manifold. RESULTS. Both PCA and PTC were applied to the proximal femur dataset, from which selected femurs were reconstructed using the accumulation of components. PCA was deemed to have failed to reconstruct the surfaces because it required 65 components to achieve high coverage of the dataset. An important observation was that the head-neck junction was the most difficult section in the femur, requiring more components than other anatomical regions to reconstruct. This finding is consistent with the surgical observation that deformations occur in this junction for abnormal hip morphologies. PTC was successful in recovering 100% of the medical data using the only the first 5 components. We note that the encoding of deformation in PTC accounting for the performance increase. PTC outperformed PCA on the dataset in descriptive compactness. CONCLUSION. A standard SSM construction method was not adequate for analysing proximal femur surfaces because it could not easily model the complexity of non-rigid deformations at the head-neck junction. Principal tangent components, a novel method for using exponential maps on manifolds, accurately reconstructed the anatomical surfaces with very few components. Future work may include extending these concepts to describe