We aimed to evaluate the utility of 68Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with 99mTc-methylene bisphosphonates (99mTc-MDP) bone scan. We studied 39 patients with suspected PJI or AL. These patients underwent 68Ga-citrate PET/CT, 99mTc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations.Aims
Methods
The December 2023 Research Roundup. 360. looks at: Tissue integration and chondroprotective potential of acetabular labral augmentation with autograft tendon: study of a porcine model; The Irish National Orthopaedic Register under cyberattack: what happened, and what were the consequences?; An overview of machine learning in orthopaedic surgery: an educational paper; Beware of the fungus…; New evidence for COVID-19 in patients undergoing
Reports of improved functional outcome of Metal on Metal Hip Resurfacing
The October 2024
Aims. To compare complication-related reoperation rates following primary
In 1975, Sweden started registering primary knee replacement surgeries based on the personal identity number. Individual-based registrations of primary total hip replacements started in 1992 and for hemiarthroplasties the registration started in 2006. The completeness of these registrations is estimated at 98% during the last 10-year period. The long history and high completeness allow for accurate calculations of population-based prevalence of
Aims. Cementing in
Introduction: We undertook an audit study to find out patient perception of being seen by a nurse practitioner in the clinic for a follow up appointment instead of a consultant and satisfaction with the joint clinic. Methods and materials: 100 patients were surveyed following their post-operation review with the nurse. Data was collected prospectively over a period of 6 months. Patients were asked to complete the questionnaire on the day of their appointment and to hand the survey prior to leaving. Hence we had 100% response rate. Results: Majority of the respondents were female (61%) with 50 % having had total hip replacements and the rest had knee replacements. 99% of respondents (94/95) felt that enough time was spent with them during the appointment. All respondents (100%) reported that they were able to ask questions and were answered satisfactorily. The consultant saw 26% of respondents; further 6% was seen by a registrar and the rest 68% were seen by the nurse specialist. Reasons for being seen by a doctor included check up or assessment, reviewing stitches and infection. 42% of respondents (33/79) were referred for further treatment either by the consultant (33%), nurse (64%) or registrar (3%). Reasons for further treatment included physiotherapy, plaster room, and further follow up (check up) appointment at 3–6 months to review the patient following surgery. 100% of respondents (97/97) were satisfied with the combined consultant/nurse clinic. 3 did not record their response. The vast majority of respondents (80%, 79/99) reported that they ‘don’t mind’ who they would have been seen by in the clinic. Discussion: The results indicate that patients are satisfied with the current clinic arrangements i.e. nurse-led clinic with the consultant being available. Hence there is a definite role for nurse led clinics for
The December 2024
Aims. The COVID-19 pandemic has disrupted the provision of
The development and implementation of Enhanced Recovery After Surgery (ERAS) protocols are of particular interest in elective orthopaedics due to clinical benefits and cost effectiveness. The Wycombe
Introduction. Circular external frames (CEF) are commonly used for a wide variety of indications, often when other devices are not appropriate. Circular frames are particularly associated with pin-site infection (PSI). Currently there is a gap in the available literature surrounding the risk of frame use with in-situ prosthetic joints. This retrospective study investigated the incidence of prosthetic joint infection (PJI) in a series of patients with in-situ
This annotation reviews current concepts on the three most common surgical approaches used for proximal interphalangeal joint
Aims. The aim of this study was to estimate time to
Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures used for the management of end-stage arthritis. With the recent introduction of robotic-assisted
Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic
Pacific people in New Zealand experience significant disparity in health outcomes. There is little known about the burden of arthritis within this community or difficulties accessing specialist orthopaedic care. This qualitative study evaluated the experiences of Pacific patients who underwent hip or knee arthroplasty with a goal to identify barriers to accessing
Aims. The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. Methods. There were 404