Advertisement for orthosearch.org.uk
Results 1 - 20 of 132
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 34 - 34
17 Nov 2023
Elliott M Rodrigues R Hamilton R Postans N Metcalfe A Jones R McGregor A Arvanitis T Holt C
Full Access

Abstract. Objectives. Biomechanics is an essential form of measurement in the understanding of the development and progression of osteoarthritis (OA). However, the number of participants in biomechanical studies are often small and there is limited ways to share or combine data from across institutions or studies. This is essential for applying modern machine learning methods, where large, complex datasets can be used to identify patterns in the data. Using these data-driven approaches, it could be possible to better predict the optimal interventions for patients at an early stage, potentially avoiding pain and inappropriate surgery or rehabilitation. In this project we developed a prototype database platform for combining and sharing biomechanics datasets. The database includes methods for importing and standardising data and associated variables, to create a seamless, searchable combined dataset of both healthy and knee OA biomechanics. Methods. Data was curated through calls to members of the OATech Network+ (. https://www.oatechnetwork.org/. ). The requirements were 3D motion capture data from previous studies that related to analysing the biomechanics of knee OA, including participants with OA at any stage of progression plus healthy controls. As a minimum we required kinematic data of the lower limbs, plus associated kinetic data (i.e. ground reaction forces). Any additional, complementary data such as EMG could also be provided. Relevant ethical approvals had to be in place that allowed re-use of the data for other research purposes. The datasets were uploaded to a University hosted cloud platform. The database platform was developed using Javascript and hosted on a Windows server, located and managed within the department. Results. Three independent datasets were curated following the call to OATech Network+ members. These originated from separate studies collected from biomechanics labs at Cardiff University, Keele University, and Imperial College London. Participants with knee OA were at various stages of progression and all datasets included healthy controls. The total sample size of the three datasets is n=244, split approximately equally between healthy and knee OA participants. Naming conventions and formatting of the exported data varied greatly across datasets. Datasets were therefore formatted into a common format prior to upload, with guidelines developed for future contributions. Uploading data at the marker set level was too complicated for combination at the prototype stage. Therefore, processed variables relating to joint angles and joint moments were used. The resulting prototype database included an import function to align and standardise variables. A a simple query tool was further developed to extract outputs from the database, along with a suitable user interface for basic data exploration. Conclusion. Combining biomechanics dataset presents a wide range of challenges from both a technical and data governance context. Here we have taken the first steps to demonstrate a proof-of-concept that can combine heterogenous data from independent OA-related biomechanics studies into a combined, searchable resource. Expanding this in the future to a fully open access database will create an essential resource that will facilitate the application of data-driven models and analyses for better understanding, stratification and prediction of OA progression. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 149 - 149
4 Apr 2023
Killen B Willems M Hoang H Verschueren S Jonkers I
Full Access

The aim of this research was to determine biomechanical markers which differentiate medial knee osteoarthritis (OA) patients who do and do not show structural progression over a 2-year period. A cohort of 36 subjects was selected from a longitudinal study (Meireles et al 2017) using Kellgren-Lawrence (KL) scores at baseline and 2-year follow-up. The cohort consisted of 10 healthy controls (HC) (KL=0 at both time points), 15 medial knee OA non-progressors (NPKOA) (KL≥1 at baseline and no change over 2 years), and 11 medial knee OA progressors (PKOA) (KL≥1 at baseline and increase of ≥1 over 2 years). 3D integrated motion capture data from three walking trials were processed through a musculoskeletal modelling framework (Smith et al 2016) to estimate knee joint loading parameters (i.e., magnitude of mean contact pressure, and centre of pressure (COP)). Parameters at first and second peak were extracted and compared between groups using Kruskal-Wallis and Mann-Whitney tests. Higher magnitudes were observed in PKOA vs NPKOA, and PKOA vs HC groups at both time points. Additionally, a posterior (1st and 2nd peak), and lateral (2nd peak) shift in medial compartment COP was shown between PKOA and NPKOA, and PKOA and HC subjects. Interestingly, in the studied parameters, no differences were observed between NPKOA and HC groups. Significantly higher magnitude, and a more posterior and lateral COP was observed between PKOA and NPKOA patients. These differences, combined with an absence of difference between NPKOA and HC suggest structural OA progression is driven by a combination of altered loading magnitude and location. These results may serve as guidelines for targeted gait retraining rehabilitation to slow or stop knee OA progression whereby shifting COP anterior and medial and reducing magnitude by ~22% may shift patients from a PKOA to a NPKOA trajectory


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 41 - 41
17 Nov 2023
Samir A Abdelghany A Metwally A
Full Access

Abstract. Objectives. To compare the effectiveness of phonophoresis (PH) and conventional therapeutic ultrasound (US) on the functional and pain outcomes of patients with knee osteoarthritis. Methods. We conducted an electronic search through PubMed, Cochrane Central Register of Clinical Trials (CENTRAL), Web of Science (WOS), and Scopus databases. We screened the retrieved articles to include only English full-text randomized controlled trials that examined the effect of phonophoresis versus conventional therapeutic ultrasound on patients with knee osteoarthritis. Two reviewers screened, extracted the data, and independently assessed the quality of the included articles. Results. A total of five randomized controlled trials met our inclusion criteria out of 267 studies screened. Our results showed no statistically significant differences between the PH and US groups (1), (2), (3),(4), and (5). The PH group demonstrated more significant effects than the UT group in reducing VAS pain scores (P=0.009) and improving WOMAC scores, although this did not reach the level of significance (P=0.143) (5). In the long term, PH therapy was found to be superior to US in improving painless walking duration and distance VAS scores (p=0.034, 0.017) respectively, as well as walking and resting walking VAS scores (p=0.03, 0.007) respectively, which were found to be permanent (3). Conclusions. Both therapies improve pain and function. However, we suggest conducting more high-quality trials with larger sample sizes and do not recommend the use of these therapies in clinical practice due to limitations in gender selection and high risk of bias. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 5 - 5
1 Dec 2021
Agarwal N Mak CC Bojanic C To K Khan W
Full Access

Abstract. Osteoarthritis (OA) is a degenerative disorder associated with cartilage loss and is a leading cause of disability around the world. In old age, the capacity of cartilage to regenerate is diminished. With an aging population, the burden of OA is set to rise. Currently, there is no definitive treatment for OA. However, cell-based therapies derived from adipose tissue are promising. A PRISMA systematic review was conducted employing four databases (MEDLINE, EMBASE, Cochrane, Web of Science) to identify all clinical studies that utilized adipose tissue derived mesenchymal stem cells (AMSCs) or stromal vascular fraction (SVF) for the treatment of knee OA. Eighteen studies were included, which met the inclusion criteria. Meta-analyses were conducted on fourteen of these studies, which all documented WOMAC scores after the administration of AMSCs. Pooled analysis revealed that cell-based treatments definitively improve WOMAC scores, post treatment. These improvements increased with time. The studies in this meta-analysis have established the safety and efficacy of both AMSC therapy and SVF therapy for knee OA in old adults and show that they reduce pain and improve knee function in symptomatic knee OA suggesting that they may be effective therapies to improve mobility in an aging population


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 19 - 19
2 Jan 2024
Castagno S Birch M van der Schaar M McCaskie A
Full Access

Precision health aims to develop personalised and proactive strategies for predicting, preventing, and treating complex diseases such as osteoarthritis (OA). Due to OA heterogeneity, which makes developing effective treatments challenging, identifying patients at risk for accelerated disease progression is essential for efficient clinical trial design and new treatment target discovery and development. To create a reliable and interpretable precision health tool that predicts rapid knee OA progression over a 2-year period from baseline patient characteristics using an advanced automated machine learning (autoML) framework, “Autoprognosis 2.0”. All available 2-year follow-up periods of 600 patients from the FNIH OA Biomarker Consortium were analysed using “Autoprognosis 2.0” in two separate approaches, with distinct definitions of clinical outcomes: multi-class predictions (categorising disease progression into pain and/or radiographic progression) and binary predictions. Models were developed using a training set of 1352 instances and all available variables (including clinical, X-ray, MRI, and biochemical features), and validated through both stratified 10-fold cross-validation and hold-out validation on a testing set of 339 instances. Model performance was assessed using multiple evaluation metrics. Interpretability analyses were carried out to identify important predictors of progression. Our final models yielded higher accuracy scores for multi-class predictions (AUC-ROC: 0.858, 95% CI: 0.856-0.860) compared to binary predictions (AUC-ROC: 0.717, 95% CI: 0.712-0.722). Important predictors of rapid disease progression included WOMAC scores and MRI features. Additionally, accurate ML models were developed for predicting OA progression in a subgroup of patients aged 65 or younger. This study presents a reliable and interpretable precision health tool for predicting rapid knee OA progression. Our models provide accurate predictions and, importantly, allow specific predictors of rapid disease progression to be identified. Furthermore, the transparency and explainability of our methods may facilitate their acceptance by clinicians and patients, enabling effective translation to clinical practice


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 23 - 23
17 Nov 2023
Castagno S Birch M van der Schaar M McCaskie A
Full Access

Abstract. Introduction. Precision health aims to develop personalised and proactive strategies for predicting, preventing, and treating complex diseases such as osteoarthritis (OA), a degenerative joint disease affecting over 300 million people worldwide. Due to OA heterogeneity, which makes developing effective treatments challenging, identifying patients at risk for accelerated disease progression is essential for efficient clinical trial design and new treatment target discovery and development. Objectives. This study aims to create a trustworthy and interpretable precision health tool that predicts rapid knee OA progression based on baseline patient characteristics using an advanced automated machine learning (autoML) framework, “Autoprognosis 2.0”. Methods. All available 2-year follow-up periods of 600 patients from the FNIH OA Biomarker Consortium were analysed using “Autoprognosis 2.0” in two separate approaches, with distinct definitions of clinical outcomes: multi-class predictions (categorising patients into non-progressors, pain-only progressors, radiographic-only progressors, and both pain and radiographic progressors) and binary predictions (categorising patients into non-progressors and progressors). Models were developed using a training set of 1352 instances and all available variables (including clinical, X-ray, MRI, and biochemical features), and validated through both stratified 10-fold cross-validation and hold-out validation on a testing set of 339 instances. Model performance was assessed using multiple evaluation metrics, such as AUC-ROC, AUC-PRC, F1-score, precision, and recall. Additionally, interpretability analyses were carried out to identify important predictors of rapid disease progression. Results. Our final models yielded high accuracy scores for both multi-class predictions (AUC-ROC: 0.858, 95% CI: 0.856–0.860; AUC-PRC: 0.675, 95% CI: 0.671–0.679; F1-score: 0.560, 95% CI: 0.554–0.566) and binary predictions (AUC-ROC: 0.717, 95% CI: 0.712–0.722; AUC-PRC: 0.620, 95% CI: 0.616–0.624; F1-score: 0.676, 95% CI: 0.673–0679). Important predictors of rapid disease progression included the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores and MRI features. Our models were further successfully validated using a hold-out dataset, which was previously omitted from model development and training (AUC-ROC: 0.877 for multi-class predictions; AUC-ROC: 0.746 for binary predictions). Additionally, accurate ML models were developed for predicting OA progression in a subgroup of patients aged 65 or younger (AUC-ROC: 0.862, 95% CI: 0.861–0.863 for multi-class predictions; AUC-ROC: 0.736, 95% CI: 0.734–0.738 for binary predictions). Conclusions. This study presents a reliable and interpretable precision health tool for predicting rapid knee OA progression using “Autoprognosis 2.0”. Our models provide accurate predictions and offer insights into important predictors of rapid disease progression. Furthermore, the transparency and interpretability of our methods may facilitate their acceptance by clinicians and patients, enabling effective utilisation in clinical practice. Future work should focus on refining these models by increasing the sample size, integrating additional features, and using independent datasets for external validation. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 106 - 106
14 Nov 2024
Bliddal H Beier J Hartkopp A Conaghan P Henriksen M
Full Access

Introduction. Polyacrylamide hydrogel (iPAAG. 1. ), is CE marked for treating symptomatic knee osteoarthritis (OA), meeting the need for an effective, long-lasting, and safe non-surgical option. This study evaluates the efficacy and safety of a single 6 ml intra-articular injection of iPAAG in participants with moderate to severe knee OA over a 5-year post-treatment period, presenting data from the 4-year follow up. Method. This prospective multicentre study (3 sites in Denmark) involved 49 participants (31 females) with an average age of 70 (range 44 – 86 years). They received a single 6 mL iPAAG injection. All participants provided informed consent and re-consented to continue after 1 year. The study followed GCP principles and was approved by Danish health authorities and local Health Research Ethics committees. Twenty-seven participants completed the 4-year follow-up. The study evaluated WOMAC pain, stiffness, function, and Patient Global Assessment (PGA) of disease impact. Changes from baseline were analysed using a mixed model for repeated measurement (MMRM). Sensitivity analyses were applied on the extension data, where the MMRM analysis was repeated only including patients in the extension phase and an ANCOVA model was used, replacing missing values at 4-years with baseline values (BOCF). Results. The planned MMRM analysis (n=49) revealed a statistically significant decrease in WOMAC pain subscale scores (-22.0; 95%CI: -29.5; -14.4) from baseline to 4-years. Analysis of the extension phase (n=27) showed similar results (-21.8; 95%CI: -29.0; -14.6) compared to the initial analysis. Furthermore, BOCF analysis indicated a statistically significant reduction in WOMAC pain subscale scores from baseline (-13.0 units). Four new adverse events were reported between the 3-year and 4-year visits; none were related to treatment. Conclusions. This study shows that single injections of 6 ml intra-articular iPAAG were well tolerated and continued to provide clinically important effectiveness at 4-years after treatment. Acknowledgements. The study was sponsored by Contura International A/S


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 123 - 123
11 Apr 2023
Ghaffari A Rahbek O Lauritsen R Kappel A Rasmussen J Kold S
Full Access

The tendency towards using inertial sensors for remote monitoring of the patients at home is increasing. One of the most important characteristics of the sensors is sampling rate. Higher sampling rate results in higher resolution of the sampled signal and lower amount of noise. However, higher sampling frequency comes with a cost. The main aim of our study was to determine the validity of measurements performed by low sampling frequency (12.5 Hz) accelerometers (SENS) in patients with knee osteoarthritis compared to standard sensor-based motion capture system (Xsens). We also determined the test-retest reliability of SENS accelerometers. Participants were patients with unilateral knee osteoarthritis. Gait analysis was performed simultaneously by using Xsens and SENS sensors during two repetitions of over-ground walking at a self-selected speed. Gait data from Xsens were used as an input for AnyBody musculoskeletal modeling software to measure the accelerations at the exact location of two defined virtual sensors in the model (VirtualSENS). After preprocessing, the signals from SENS and VirtualSENS were compared in different coordinate axes in time and frequency domains. ICC for SENS data from first and second trials were calculated to assess the repeatability of the measurements. We included 32 patients (18 females) with median age 70.1[48.1 – 85.4]. Mean height and weight of the patients were 173.2 ± 9.6 cm and 84.2 ± 14.7 kg respectively. The correlation between accelerations in time domain measured by SENS and VirtualSENS in different axes was r = 0.94 in y-axis (anteroposterior), r = 0.91 in x-axis (vertical), r = 0.83 in z-axis (mediolateral), and r = 0.89 for the magnitude vector. In frequency domain, the value and the power of fundamental frequencies (F. 0. ) of SENS and VirtualSENS signals demonstrated strong correlation (r = 0.98 and r = 0.99 respectively). The result of test-retest evaluation showed excellent repeatability for acceleration measurement by SENS sensors. ICC was between 0.89 to 0.94 for different coordinate axes. Low sampling frequency accelerometers can provide valid and reliable measurements especially for home monitoring of the patients, in which handling big data and sensors cost and battery lifetime are among important issues


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 19 - 19
4 Apr 2023
Manukyan G Gallo J Mikulkova Z Trajerova M Savara J Slobodova Z Kriegova E
Full Access

An increased number of neutrophils (NEUs) has long been associated with infections in the knee joints; their contribution to knee osteoarthritis (KOA) pathophysiology remains largely unexplored. This study aimed to compare the phenotypic and functional characteristics of synovial fluid (SF)-derived NEUs in KOA and knee infection (INF). Flow cytometric analysis, protein level measurements (ELISA), NEU oxidative burst assays, detection of NEU phagocytosis (pHrodo. TM. Green Zymosan Biparticles. TM. Conjugate for Phagocytosis), morphological analysis of the SF-derived/synovial tissue NEUs, and cultivation of human umbilical vein endothelial cells (HUVECs) using SF supernatant were used to characterise NEUs functionally/morphologically. Results: Compared with INF NEUs, KOA NEUs were characterised by a lower expression of CD11b, CD54 and CD64, a higher expression of CD62L, TLR2 and TLR4, and lower production of inflammatory mediators and proteases, except CCL2. Functionally, KOA NEUs displayed an increased production of radical oxygen species and phagocytic activity compared with INF NEUs. Morphologically, KOA and INF cells displayed different cell sizes and morphology, histological characteristics of the surrounding synovial tissues and influence on endothelial cells. KOA NEUs were further subdivided into two groups: SF containing <10% and SF with 10%–60% of NEUs. Analyses of two KOA NEU subgroups revealed that NEUs with SF <10% were characterised by 1) higher CD54, CD64, TLR2 and TLR4 expression on their surface; 2) higher concentrations of TNF-α, sTREM-1, VILIP-1, IL-1RA and MMP-9 in SFs. Our findings reveal a key role for NEUs in the pathophysiology of KOA, indicating that these cells are morphologically and functionally different from INF NEUs. Further studies should explore the mechanisms that contribute to the increased number of NEUs and their crosstalk with other immune cells in KOA. This study was supported by the Ministry of Health of the Czech Republic (NU20-06-00269; NU21-06-00370)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 53 - 53
1 Dec 2021
De Vecchis M Naili JE Wilson C Whatling GM Holt CA
Full Access

Abstract. Objectives. Exploring the relationship of gait function pre and post total knee replacement (TKR) in two groups of patients. Methods. Three-dimensional gait analysis was performed at Cardiff University, UK, and Karolinska University Hospital, Sweden, on 29 and 25 non-pathological (NP) volunteers, and 39 and 28 patients with end-stage knee osteoarthritis (OA), respectively. Patients were assessed pre and one-year post-TKR. Data reduction was performed via Principal Component (PC) analysis on twenty-four kinematic and kinetic waveforms in both NP and pre/post-TKR. Cardiff's and Karolinska's cohorts were analysed separately. The Cardiff Classifier, a classification system based on the Dempster-Shafer theory, was trained with the first 3 PCs of each variable for each cohort. The Classifier classifies each participant by assigning them a belief in NP, belief in OA (BOA) and belief in uncertainty, based on their biomechanical features. The correlation between patient's BOA values (range: 0–1, 0 indicates null BOA and 1 high BOA) pre and post-TKR was tested through Spearman's correlation coefficient in each cohort. The related-samples Wilcoxon signed-rank test (α=0.05) determined the significant changes in BOA in each cohort of patients. The Mann-Whitney U test (α=0.05) was run to explore differences between the patients’ cohorts. Results. There were no significant differences between patients’ cohorts in median age (p=0.096), height (p=0.673), weight (p=0.064) or KOOS sub-scores pre or post-TKR (p-value ranged 0.069 to 0.955) but Cardiff's patients had a significantly higher BMI (p=0.047). There was a significant, median decrease of 0.12 and 0.19 in the BOA pre to post TKR (p<0.001) in Cardiff's and Karolinska's patients, respectively. There was a statistically significant, strong positive correlation between the BOA pre and post-TKR (Cardiff:r. s. =0.706, p<0.001; Karolinska:r. s. =0.669, p<0.001). Conclusions. In two distinct cohorts of patients, having a more compromised gait function in end-stage knee OA was correlated with poorer gait function post-TKR


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 169 - 169
1 Jul 2014
Arnold J Mackintosh S Jones S Thewlis D
Full Access

Summary Statement. This study provides preliminary evidence that people with knee osteoarthritis have greater asymmetry in joint loading than healthy controls. Altered loading of the contralateral limb may signify increased risk of injury to other lower limb joints in knee osteoarthritis. Introduction. Compensatory overloading of other lower limb joints is a potential reason for the non-random evolution of osteoarthritis (OA). In individuals with knee OA altered joint loading exists of the contralateral cognate joints. However, previous studies have neglected the temporal features of asymmetry in joint loading. The study aimed to identify the amount and temporal features of asymmetry in lower limb joint loading in advanced knee OA. Patients and Methods. Participants (n=15) were awaiting primary unilateral total knee replacement for OA (age 67.0 SD 8.9 years, height 1.66 SD 0.13 m, mass 84.2 SD 15.8 kg, BMI 30.7 SD 6.2 kg/m. 2. , median KL grade 4). Data were compared to asymptomatic age and sex matched controls. Kinematic and kinetic data during walking was acquired with 12 cameras (VICON MX-F20) and two Kistler force platforms at 100 Hz and 400 Hz respectively. Data were analysed in Visual3D (C-Motion Inc., USA). Asymmetry was computed in MatLab using a recently published symmetry index (SI) and symmetry function (SF). Variables (computed using inverse dynamics) were the peak external moments (%BW∗Height) of the hip, knee and ankle. Differences between means of the SI variables in the OA and control groups were compared using Student's t-tests. Discrete variables were also compared between limbs (paired t-test) or between the affected limb and matched control limb. Effect sizes (Cohen's d) for the differences were also computed. Results. A significant between group difference (OA and control) for SI was observed for the transverse plane ankle joint moment (16.1 SD 8.0 vs. 10.4 SD 4.8 d = 0.8 p = 0.049). A large effect size for the sagittal plane knee joint moment (22.9 SD 12.1 vs. 12.7 SD 5.1 d = 1.1 p = 0.178) and a medium effect size for the transverse plane hip joint moment (26.4 SD 15.9 vs. 16.6 SD 9.0 d = 0.7 p = 0.098) were observed. The unaffected limb (OA group) had higher peak hip flexion (5.76 SD 1.49 vs.5.32 SD 1.51 p = 0.041) and internal rotation moments (−0.67 SD 0.34 vs. −0.41 SD 0.18 d = 0.004) and a lower ankle inversion moment (0.16 SD 0.14 vs. 0.34 SD 0.24 d = 0.9 p = 0.030) compared to the affected limb. Only the difference in the first peak knee adduction moment for the affected and matched control limb was statistically significant (−2.65 SD 1.38 vs. −2.16 SD 1.16 d = 0.7 p = 0.031). Discussion and Conclusion. This study provides preliminary evidence of more asymmetry in joint moments of the lower limb in people with knee OA compared to controls. Further investigation with a larger sample is required to verify these findings. Altered loading of the contralateral cognate joints may signify increased risk of injury at the hip and ankle and highlights the need for monitoring of other lower limb joints in knee OA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 14 - 14
1 Jan 2017
Favre J Babel H Omoumi P Jolles B
Full Access

Knee osteoarthritis (OA) affects an estimated 250 million people worldwide, with a cure yet to be found. Consequently, there is an urgent need to improve our understanding of OA physiopathology. While knee OA has long been mostly described as a loss of cartilage thickness (CTh) and research has focused on this characteristic, the role of bone alterations is rapidly gaining in interest. Analyzing subchondral bone mineral density (sBMD) is particularly interesting because this could inform on the mechanical environment at the knee. However, there is a paucity of data on sBMD in literature mainly because of the lack of prior methods to measure this parameter. A method for 3D sBMD assessment based on computed tomography (CT) scans was recently proposed, thus allowing testing for sBMD differences in knee OA. This study aimed at comparing non-OA and medial OA knees in terms of tibial sBMD and CTh. Specifically, it was hypothesized that sBMD and CTh differ with OA. Ten knees with severe medial OA and 10 matched non-OA knees were analyzed after ethical approval (50% male; 60 ± 3 years old). The arthro-CT scans of the 20 knees were segmented using custom software to build 3D mesh models of the tibial bone and cartilage. CTh maps were obtained by calculating the distance between cartilage and bone meshes, while sBMD maps were calculated based on the intensity of the CT in the first 3mm of bone. For each knee, the average CTh and sBMD values over the entire medial and lateral compartments were calculated and used to determine the medial-to-lateral (M/L) CTh and sBMD ratios. Unpaired t-tests and receiver operating characteristic (ROC) were used for statistical analysis. The M/L sBMD ratio was significantly higher in OA compared to non-OA knees (1.14 ± 0.04 vs. 1.08 ± 0.03; p<0.01), whereas the CTh ratio was not significantly different between groups (0.70 ± 0.21 vs. 0.85 ± 0.10; p=0.06). No significant differences were found between OA and non-OA knees for the average medial CTh and sBMD (p>0.4). High classification performance was obtained for the sBMD ratio and low performance for the average sBMD in the medial compartment (areas under the ROC curve of 0.9 and 0.6, respectively). CTh ratio and medial compartment average provided medium classification performances (areas under the curve of 0.7). This study showed that sBMD differed between non-OA and severe medial OA knees and that sBMD M/L ratio was more sensitive to OA severity than CTh variables. These results brought new insights into the pathogenesis of knee OA, by supporting the idea that sBMD is altered with OA and suggesting that sBMD could play a role in disease development. Indeed, the mechanical stresses on the cartilages are related to the mechanical characteristics of the bones. Indirectly, this study also demonstrated the value of arthro-CT scans to simultaneously assess sBMD and CTh. Additional studies with larger cohorts of patients at different stages of the disease are necessary to better understand when changes in sBMD occur


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 33 - 33
14 Nov 2024
Fallahy M Shaker F Ghanbari F Aslani MA Mohammadi S Behrouzieh S
Full Access

Introduction. Knee Osteoarthritis (KOA) is a prevalent joint disease requiring accurate diagnosis and prompt management. The condition occurs due to cartilage deterioration and bone remodeling. Ultrasonography has emerged as a promising modality for diagnosing KOA. Medial meniscus extrusion (MME), characterized by displacement of medial meniscus beyond the joint line has been recognized as a significant marker of KOA progression. This study aimed to explore potentials Ultrasound findings in timely detection of MME and compare it to magnetic resonance imaging (MRI) as a reference standard. Method. A comprehensive literature search was performed in 4 databases from inception to May 1 2024. Two independent reviewers, initiated screening protocols and selected the articles based on inclusion and exclusion criteria and then extracted the data. Meta-analysis was conducted using R 4.3.2 packages mada and metafor. Result. A total of 2500 articles from 4 databases was retrieved; however, following the application of inclusion and exclusion criteria 23 articles were finally extracted. These studies collectively encompassed a total of 777 patients with mean age of 53.2±7.4. The mean BMI calculated for patients was 28.31 ± 2.45. All patients underwent non-weight bearing knee ultrasonography in supine position with 0° flexion. The reported medial meniscus extrusion was 2.58 mm for articles using MRI and 2.65 mm for those using Ultrasound (MD: 0.05 ± 0.12, P= 0.65, I. 2. : 54%). Our meta-analysis revealed insignificant difference between US and MRI. (SMD: 0.03, 95% CI: -0.18 _0.23, P= 0.77, I. 2. : 56%) Meta analysis for diagnostic accuracy measures yielded a pooled sensitivity and specificity of 90.8% and 77% (95% CI: 84.2% – 94.8%, 35.5% – 95.3%, respectively, I. 2. : 44%). Conclusion. Our results indicate a close alignment in the accuracy of measurements obtained using Ultrasound modality. The narrow range suggests a minimal discrepancy in MME values between MRI and ultrasound, highlighting their comparable precision in diagnostic assessments


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 64 - 64
1 Dec 2021
Hamilton R Holt C Hamilton D Jones R Shillabeer D Kuiper JH Sparkes V Mason D
Full Access

Abstract. Objectives. Current tools to measure pain are broadly subjective impressions of the impact of the nociceptive impulse felt by the patient. A direct measure of nociception may offer a more objective indicator. Specifically, movement-induced physiological responses to nociception may offer a useful way to monitor knee OA. In this proof-of-concept study, we evaluated whether integrated biomechanical and physiological sensor datasets could display linked and quantifiable information to a nociceptive stimulus. Method. Following ethical approval, we applied a quantified thermal pain stimulus to a volunteer during stationary standing in a gait lab setting. An inertial measurement unit (IMU) and an electromyography (EMG) lower body marker set were tested and integrated with ground reaction force (GRF) data collection. Galvanic skin response electrodes and skin thermal sensors were manually timestamp linked to the integrated system. Results. The integrated EMG, GRF and IMU data show fluctuations within 0.5 seconds of each other when a thermal pain trigger is applied at several time points during a stationary standing test. Manually timestamped physiology measures displayed increased values during testing for skin conductivity (up to 5 µSiemens, 37% compared to baseline) and skin temperature (up to 0.3˚C, 1% compared to baseline). Conclusions. This proof-of-concept study suggests that physiological data mimics biomechanical data in response to a known pain stimuli. While this protocol requires further evaluation as to the measurement parameters, the association of the physiological output to the known pain stimulus suggests the potential development of wearable nociceptive sensors that can measure disease progression and treatment effectiveness


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 101 - 101
1 Jan 2017
Bottegoni C Gigante A
Full Access

The objective of this study was to evaluate the safety and the effect of platelet-rich plasma (PRP) intra-articular injections obtained from blood donors (homologous PRP) on elderly patients with early or moderate knee osteoarthritis (OA) who are not candidates for autologous PRP treatment. A total of 60 symptomatic patients, aged 65–86 years, affected by hematologic disorders and early or moderate knee OA, were treated with 5 ml of homologous PRP intraarticular injections every 14 days for a total of three injections. Clinical evaluations before the treatment, and after 2 and 6 months were performed by International Knee Documentation Committee (IKDC), Knee injury and Osteoarthritis Outcome Score (KOOS) and Equal Visual Analogue Scale (EQ VAS) scores. Adverse events and patient satisfaction were recorded. No severe complications were noted during the treatment and the follow-up period. A statistically significant improvement from basal evaluation to the 2-month follow-up visit was observed, whereas a statistically significant worsening from the 2-month to the 6-month follow-up visit was showed. The overall worst results were observed in patients aged 80 years or over and in those affected by minor bone attrition. It was found that 90% of patients were satisfied at the 6-month evaluation. Homologous PRP has an excellent safety profile but offers only a short-term clinical improvement in selected elderly patients with knee OA who are not candidates for autologous PRP treatment. Increasing age and developing degeneration result in a decreased potential for homologous PRP injection therapy. Further studies are needed to confirm these findings


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 41 - 41
1 May 2012
Metcalfe A Stewart C Postans N Dodds A Smith H Holt C Roberts A
Full Access

Introduction. Patients with knee osteoarthritis (OA) often tell us that they put extra load on the joints of the opposite leg as they walk. Multiple joint OA is common and has previously been related to gait changes due to hip OA (Shakoor et al 2002). The aim of this study was to determine whether patients with medial compartment knee OA have abnormal biomechanics of the unaffected knee and both hips during normal level gait. Methods. Twenty patients (11 male, 9 female), with severe medial compartment knee OA and no other joint pain were recruited. The control group comprised 20 adults without musculoskeletal pain. Patients were reviewed, x-rays were examined and WOMAC and Oxford knee scores were completed. A 12 camera Vicon (Vicon, Oxford) system was used to collect kinematic data (100Hz) on level walking and the ground reaction force was recorded using three AMTI force plates (1000Hz). Surface electrodes were placed over medial and lateral quadriceps and hamstrings bilaterally to record EMG data (1000Hz). Kinematics and kinetics were calculated using the Vicon ‘plug-in-gait’ model. A co-contraction index was calculated for the EMG signals on each side of the knee, representing the magnitude of the combined readings relative to their maximum contraction during the gait cycle. Statistical comparisons were performed using t-tests with Bonferroni's correction for two variables and ANOVA for more than two variables (SPSS v16). Results. The mean age of the patients was 69 (SD 8.8). Mean gait speed was 0.95m/s (study group) and 1.44m/s (control group). Peak adduction moments for the OA group [OA Knee; Unaffected Knee; Ipsilateral Hip; Contralateral Hip; in Nm/Kg(±95% CI)] were: 0.55(0.06); 0.47(0.06); 0.73(0.09); 0.73(0.08). Control values for peak moments were 0.64 (0.06) for the knee and 0.81(0.07) at the hip. Mid-stance adduction moments for the OA group (listed as before) were: 0.44(0.08); 0.33(0.06); 0.64(0.06); 0.61(0.08). Control values for mid-stance moments were 0.14(0.03) and 0.40(0.04). [OA group vs. Controls: p=NS for peak moments at all 4 joints; p<0.01 for mid-stance moments at all joints]. Co-contraction indices for hamstrings and quads, [OA knee medial; and lateral; unaffected knee medial; and lateral; control medial; and lateral; 0<X. Discussion. Although the affected subjects all had only single joint OA, abnormal moments were present in the hips and knees of both legs during normal level gait, despite the reduced gait speed of the OA cohort. Abnormal hamstring and quadriceps co-contraction occurs bilaterally in patient with single joint OA. Increased trunk sway is a recognised compensation in knee OA and may be the cause of the abnormal hip and contra-lateral knee loading found in this study. Further investigation is warranted and may lead to improvements in the long term outcome for these patients. Acknowledgement. The study was funded by the North Wales NHS Trust


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 83 - 83
1 Nov 2018
Flynn S O'Reilly M Feeley I Sheehan E
Full Access

Knee osteoarthritis is a common, debilitating condition. Intra articular corticosteroid injections are a commonly used non-operative treatment strategy. Intra articular hip injection with Ketorolac (an NSAID) has proven to be as efficacious as corticosteroids. No prior study compares the efficacy of Ketorolac relative to corticosteroids for relief of discomfort in knee osteoarthritis. The study design was a single centre double blinded RCT. Severity of osteoarthritic changes were graded on plain film weightbearing radiographs using the Kellgren and Lawrence system. Injection was with either 30mg Ketorolac or 40mg Methylprednisolone, given by intra-articular injection, in a syringe with 5mls 0.5% Marcaine. Pre-injection clinical outcomes were assessed using the Numerical Pain Score (NPS), WOMAC, and Oxford knee scores. Patients' NPS scores were assessed at Day 1 and Day 14 post-injection. An assessment of all clinical outcomes took place in clinic at six weeks. There were 72 participants (83 knees) in the study. No patients were lost to follow-up. Mean age was 62.66 years (Range 29–85). 42 knees received a corticosteroid injection, 41 a NSAID injection. Mean Kellgren and Lawrence score was 3.1. There was no significant difference in pre-injection clinical scores in either group. There was a significant improvement of NPS on Day 1 and 14 in both injection groups(p<0.05). These improved pain scores were sustained at 6 weeks in both groups. WOMAC and Oxford Knee Scores showed a statistically significant improvement in the corticosteroid group. WOMAC scores showed significant improvement in the NSAID group, however these improvements didn't achieve statistical significance using the Oxford Knee Score. Corticosteroid or NSAID injectate are a safe and effective non-operative treatment strategy in the patient with knee osteoarthritis. Ketorolac appears to provide effective medium-term improvement of pain and clinical scores. Further follow-up is recommended to investigate if this trend in sustained


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 148 - 148
1 Nov 2021
Maheu E Soriot-Thomas S Noël E Ganry H Lespesailles E Cortet B
Full Access

Introduction and Objective. Knee osteoarthritis (KOA) is a frequent disease for which therapeutic possibilities are limited. In current recommendations, the first-line analgesic is acetaminophen. However, low efficacy of acetaminophen, frequently leads to the use of weak opioids (WO) despite their poor tolerance, especially in elderly patients. The primary objective was to compare the analgesic efficacy and safety of a new wearable transcutaneous electrical nerve stimulation (W-TENS) to weak opioids (WO) in the treatment of moderate to severe, nociceptive, chronic pain in knee osteoarthritis patients. Materials and Methods. ArthroTENS study is a phase 3, non-inferiority, multicentric, prospective, randomized, single-blinded for primary efficacy outcome, controlled, in 2-parallel groups, clinical study comparing W-TENS versus WO over a 3-month controlled period with an additional, optional, non-controlled, 3-month follow-up for patients in W-TENS group. The co-primary outcome was KOA pain intensity (PI) at month 3 and the number of adverse events (AEs) over 3 months. Results. The non-inferiority of W-TENS was demonstrated in both the PP and ITT populations. At M3, PI in PP population was 3.87 (2.12) compared to 4.66 (2.37) (delta: −0.79 (0.44); 95% CI (−1.65; 0.08)) in W-TENS and WO groups, respectively. Since the absolute value of the 95% CI of the between-treatments mean PI difference [−1.71, – 0.12] was above 0 in ITT set, the planned superiority analysis was performed, demonstrating that W-TENS was significantly superior to WO at M3 (P=0.0124). At M1 and M3, the W-TENS group reached the absolute minimal clinically important difference (MCID) for an analgesic (1.8 (2.1) and 2.1 (2.3), respectively), corresponding to a 20 mm reduction in PI (interquartile range: 15–30) on a 0–100 mm visual analogic scale – i.e. 2 points on a numerical rating scale – which equates to “much better”. Conversely, in the WO group, a 0.5 (1.8) and a 1.1 (2.1) reduction in PI were observed at M1 and M3, respectively, while a 1-point reduction in PI is required to be considered as a “slightly better” improvement. In WO group, AEs were the common systemic AEs reported with WO (nausea, constipation, drowsiness, dizziness, pruritus, vomiting, dry mouth). AEs in W-TENS group were local, such as local cutaneous reaction (erythema). Thirty-nine (70.9%) patients wished to extend W-TENS treatment for 3 additional months. Only one patient discontinued this additional period and results were maintained at M6. Conclusions. W-TENS was more effective and better tolerated than WO in the treatment of nociceptive KOA chronic pain and could represent an interesting non-pharmacological alternative to WO


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 97 - 97
1 Jul 2014
Wen C Wong K Liu C Yan C Lu W Chiu K
Full Access

Summary Statement. OA knee with subchondral cyst formation presented differential microstructure and mechanical competence of trabecular bone. This finding sheds light on the pivot role of subchondral cyst in OA bone pathophysiology. Introduction. Subchondral bone cyst (SBC) is a major radiological finding in knee osteoarthritis (OA), together with joint space narrowing, osteophyte and sclerotic bone formation. There is mounting evidence showing that SBC originates in the same region as bone marrow lesions (BMLs). The presence of subchondral bone cyst (SBCs), in conjunction with BMLs, was associated with the severity of pain, and was able to predict tibial cartilage lolume loss and risk of joint replacement surgery in knee OA patient. It is speculated that the presence of SBCs might increase intraosseous pressure of subchondral bone, and trigger active remodeling and high turnover of surrounding trabecular bone. Yet the exact effect of SBC on the structural and mechanical properties trabecular bone, which provides the support to overlying articular cartilage, remains to be elucidated. Therefore, this study aimed to investiate the microstructure and mechanical competence of trabecular bone of knee OA in presence or absence of SBC. Patients & Methods. A total of 20 postmenopausal women (54–87 years old) with the late-stage of primary knee OA were recruited in this study. Tibial plateau specimens were collected during joint replacement surgery. The samples were grouped for comparison according to presence or absences of SBC in micro-CT images. For micro-CT examination, a cylindrical volume of region of interest (VOI) of 10mm in diameter and 1mm in height was used to cover the trabecular bone region surrounding SBC, and then a cubic VOI of 3.5×3.5×3.5mm. 3. was applied in different anatomic locations of tibial plateau, such as medial, intermediate and lateral part, for the analyses of trabecular bone microstructure. Subsequently, two cylinders of subchondral bone specimens were drilled for each sample with micro-CT guidance from lateral portion of cystic wall along the direction of physiological loading of knee joint. The specimens were processed for micro-CT and mechanical testing using MTS 858 Mini Bionix sequentially. Each specimen was compressed in a longitudinal direction at a speed of 1mm/minute; the ultimate strength and modulus of the specimens were generated. Comparisons of microstructure and mechanical properties of trabecular bone were performed between two groups using student t test. The structure-mechanics relationship was also investigated using Pearson correlation. Results. The bone volume fraction (BV/TV, %) was significantly higher in knee OA specimens in presence of SBC (32±7%) in comparison with those in absence of SBC (16±5%, p<0.001). Meanwhile there were more plate-like trabecular bone surrounding SBC (0.78±0.61) than those without SBC (1.81±0.28, p<0.001), which was indicated by structure model index (0∼3). Furthermore, the trend in conversion of rod-like (close to 3) towards plate-like trabeculae was noticed in different locations of knee OA specimens with SBC formation. Trabecular bone around SBC presented higher modulus (73±22MPa) compared with those without SBC (45±29MPa, p=0.034). The stiffer trabecular bone in presence of SBC correlated with its plate-like morphology (r=0.696, p<0.001) as well as bone volume fraction (r=0.578, p=0.004). Conclusion. Presence of SBC was associated with conversion of trabeculae towards plate-like morphology together with the increase of mechanical competence in advanced knee OA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 129 - 129
1 Jul 2014
Oomen P Meijer K van der Westen R Gransier R Emans P van Rhijn L
Full Access

Summary. The quantification of T1Rho relaxation times is not related with internal loading. Improvements in modeling and imaging techniques might lead to better understanding of the pathomechanics of the knee. Introduction. The onset and progression of knee osteoarthritis has been associated with an increased external knee adduction moment (EKAM). However, this external measure has no direct relationship with internal loading of the knee. For a better understanding of the pathomechanics of the knee musculoskeletal models could be used to relate external and internal knee loading. Consequently, high internal loading might cause cartilage degeneration in patients with OA. T1RhoMRI can detect changes in proteoglycan content and is therefore a non-invasive measure of cartilage degeneration in knee OA. The purpose of this study was to relate internal loading of the knee simulated by musculoskeletal models with cartilage health using T1rhoMRI. Patients & Methods. Preliminary results showed data of seven women (50–65yrs), four healthy and three OA. Subjects underwent 3D gait analysis (VICON Nexus) at comfortable walking speed, EKAM was calculated. Simulations of multi-body musculoskeletal models were driven based on the motion capture data, in order to calculate internal medial-lateral knee forces (MLforce). Besides a T1RhoMRI scan of the knee (Phillips 3T) provided cartilage health of the midsection of the medial condyle according to Pedersen et al, 2011 [4]. Differences between healthy and OA were tested with a one sided T-test, correlations between EKAM and MLforce were calculated. Results. Anthropometrics and walking speed showed no significantly different between OA patients and healthy controls. OA patients had significant larger EKAM and MLforce (p<0.05). T1Rho values were not significantly different between the groups. EKAM was positively correlated with MLforce (R. 2. =0.91, p<0.05) in healthy subjects, no association was found in knee OA patients (R. 2. < 0.01). Discussion / Conclusion. The current study demonstrates that external loading of the knee does not predict internal loading in knee OA patients. We did not find a significant effect of knee OA on cartilage quality assessed by T1Rho MRI. However a non-significant increase was visible at the posterior region of the femoral condyle in OA patients. This elevated T1Rho relaxation is in line with expectations and could be related to an increased cartilage degeneration