Advertisement for orthosearch.org.uk
Results 1 - 20 of 1731
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1411 - 1415
1 Oct 2011
Wainwright C Theis J Garneti N Melloh M

We compared revision and mortality rates of 4668 patients undergoing primary total hip and knee replacement between 1989 and 2007 at a University Hospital in New Zealand. The mean age at the time of surgery was 69 years (16 to 100). A total of 1175 patients (25%) had died at follow-up at a mean of ten years post-operatively. The mean age of those who died within ten years of surgery was 74.4 years (29 to 97) at time of surgery. No change in comorbidity score or age of the patients receiving joint replacement was noted during the study period. No association of revision or death could be proven with higher comorbidity scoring, grade of surgeon, or patient gender.

We found that patients younger than 50 years at the time of surgery have a greater chance of requiring a revision than of dying, those around 58 years of age have a 50:50 chance of needing a revision, and in those older than 62 years the prosthesis will normally outlast the patient. Patients over 77 years old have a greater than 90% chance of dying than requiring a revision whereas those around 47 years are on average twice as likely to require a revision than die. This information can be used to rationalise the need for long-term surveillance and during the informed consent process.


Bone & Joint Research
Vol. 13, Issue 7 | Pages 321 - 331
3 Jul 2024
Naito T Yamanaka Y Tokuda K Sato N Tajima T Tsukamoto M Suzuki H Kawasaki M Nakamura E Sakai A

Aims. The antidiabetic agent metformin inhibits fibrosis in various organs. This study aims to elucidate the effects of hyperglycaemia and metformin on knee joint capsule fibrosis in mice. Methods. Eight-week-old wild-type (WT) and type 2 diabetic (db/db) mice were divided into four groups without or with metformin treatment (WT met(-/+), Db met(-/+)). Mice received daily intraperitoneal administration of metformin and were killed at 12 and 14 weeks of age. Fibrosis morphology and its related genes and proteins were evaluated. Fibroblasts were extracted from the capsules of 14-week-old mice, and the expression of fibrosis-related genes in response to glucose and metformin was evaluated in vitro. Results. The expression of all fibrosis-related genes was higher in Db met(-) than in WT met(-) and was suppressed by metformin. Increased levels of fibrosis-related genes, posterior capsule thickness, and collagen density were observed in the capsules of db/db mice compared with those in WT mice; these effects were suppressed by metformin. Glucose addition increased fibrosis-related gene expression in both groups of mice in vitro. When glucose was added, metformin inhibited the expression of fibrosis-related genes other than cellular communication network factor 2 (Ccn2) in WT mouse cells. Conclusion. Hyperglycaemia promotes fibrosis in the mouse knee joint capsule, which is inhibited by metformin. These findings can help inform the development of novel strategies for treating knee joint capsule fibrosis. Cite this article: Bone Joint Res 2024;13(7):321–331


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 69 - 69
1 Sep 2012
Hirokawa S Fukunaga M Tsukamoto M Akiyama T Horikawa E Mawatari M
Full Access

The objective of this study is to determine the knee joint forces when rising from a kneeling position. We have developed a new type of knee prosthesis which is capable of attaining Japanese style sitting. To run the simulations and experiments needed to assess the performance of this prosthesis, it is necessary to know what forces act on the knee during deep flexion. Because these data are lacking, we created a 2D mathematical model of the lower leg to help determine knee joint forces during deep flexion. Healthy subjects of ten males (age of 25±4years, height of 170.3±9.1cm, and weight of 67.0±22.2kg) and five females (25±3years, 161±7.1cm, 47.7±6.2kg) participated in the experiment. Ground reaction force and joints angles were measured using a force plate and a motion recording system respectively. The collected data were entered into our mathematical model, and the muscle forces and the knee joint forces were calculated. To verify our model, we first used it to run simulation of middle and high flexions of the knee joint. In vivo data for these actions are available in the literature, and the results from our simulation were in good agreement with these data. We then collected the data and run simulation when rising from a kneeling position under the conditions shown in Fig. 1. They were a) double leg rising (both legs are aligned) without using the arms, b) ditto but using the arms, c) single leg rising (legs are in the front and the rear respectively) without using the arms, and d) ditto but using the arms. We obtained the following results. The statistics of the maximum values on the single knee joint for each condition were; a) Fmax=5.1±0.4 [BW: (force on the knee joint)/(body weight)] at knee flexion angle of Q=140±8°, b) Fmax=3.2±0.9[BW] at Q=90±10°, c) Fmax-d=5.4±0.5[BW] at Qd=62±20° for the dominant leg and Fmax-s=3.0±0.5[BW] at Qs=138±6° for the supporting leg respectively, and d) Fmax-d=3.9±1.5[BW] at Qd=70±17° for the dominant, and Fmax-s=2.1±0.5 [BW] at Qs=130±11° for the supporting. We may conclude that the single leg rising should be recommended since the maximum knee joint force did not become large as long as the knee was at deep flexion. The values introduced in this study could be used to assess the strength of the knee prosthesis at deep flexion. To obtain more realistic values of the joint forces, it is necessary to determine the ratio of the forces exerted by the mono-articular and the bi-articular joint muscles


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 102 - 102
1 Nov 2021
Forriol F
Full Access

The knee joint has also a periarticular adipose tissue, which is known as Hoffa's fat pad (IPFP). IPFP has a dual function in the joint it reduces the concentration of Nitric Oxide, the release of glycosaminoglycans and the expression of MMP1 in the cartilage, but it also contains MSC and macrophages. Our hypothesis is that synovial fluid contains elements, not all of which are understood, which act as messengers and alter the “homeostasis” of the knee and the metabolism of all the cellular components of the joint, including the MSC of Hoffa's fat pad, thus making them another piece in the puzzle as far as OA of the knee is concerned. The IPFP of 37 patients with OA and 36 patients with ACL rupture were analyzed. Isolation, primary culture, and a functional and proteomic study of MSCs from IPFP were performed. Our results show that OA of the knee, in its more severe phases, also affects the MSC's of IPFP, which is a new actor in the OA degenerative process and which can contribute to the origin, onset and progression of the disease. A differential protein profile between OA and ACL patients were identified. Infrapatellar pad should be regarded as an adipose tissue with its own characteristics and it´s also able to produce and excrete important inflammatory mediators directly into the knee joint


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 80 - 80
7 Aug 2023
Liu A Qian K Dorzi R Alabdullah M Anand S Maher N Kingsbury S Conaghan P Xie S
Full Access

Abstract. Introduction. Knee braces are limited to providing passive support. There is currently no brace available providing both continuous monitoring and active robot-assisted movements of the knee joint. This project aimed to develop a wearable intelligent motorised robotic knee brace to support and monitor rehabilitation for a range of knee conditions including post-surgical rehabilitation. This brace can be used at home providing ambulatory continuous passive movement obviating the need for hospital admissions. Methodology. A wearable sensing system monitoring knee range of motion was developed to provide remote feedback to clinicians and real-time guidance for patients. A prototype of an exoskeleton providing dynamic motion assistance was developed to help patients complete their exercise goals and strengthen their muscles. The accuracy and reliability of those functions were validated in human participants during exercises including knee flexion/extension (FE) in bed and in chair, sit-to-stand and stand-to-sit. Results. The knee FE measurement from the sensing system showed high accuracy (correlation coefficient of 0.99°) in human participants. The real-time FE data during exercises showed that the desired exoskeleton rotation fitted well with the participant's knee rotation. This indicated the exoskeleton could coordinate with the participant's knee motion by providing consistent motion assistance. The development of user interfaces to provide feedback is currently underway. Conclusion. A wearable robotic knee brace to monitor and support knee rehabilitation exercises was successfully developed. Further development of this device with the use of artificial intelligence has the potential to aid patient rehabilitation in a variety of knee conditions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 97 - 97
11 Apr 2023
Milakovic L Dandois F Fehervary H Scheys L
Full Access

This study aims to create a novel computational workflow for frontal plane laxity evaluation which combines a rigid body knee joint model with a non-linear implicit finite-element model wherein collateral ligaments are anisotropically modelled using subject-specific, experimentally calibrated Holzpfel-Gasser-Ogden (HGO) models. The framework was developed based on CT and MRI data of three cadaveric post-TKA knees. Bones were segmented from CT-scans and modelled as rigid bodies in a multibody dynamics simulation software (MSC Adams/view, MSC Software, USA). Medial collateral and lateral collateral ligaments were segmented based on MRI-scans and are modelled as finite elements using the HGO model in Abaqus (Simulia, USA). All specimens were submitted varus/valgus loading (0-10Nm) while being rigidly fixed on a testing bench to prevent knee flexion. In subsequent computer simulations of the experimental testing, rigid bodies kinematics and the associated soft-tissue force response were computed at each time step. Ligament properties were optimised using a gradient descent approach by minimising the error between the experimental and simulation-based kinematic response to the applied varus/valgus loads. For comparison, a second model was defined wherein collateral ligaments were modelled as nonlinear no-compression spring elements using the Blankevoort formulation. Models with subject-specific, experimentally calibrated HGO representations of the collateral ligaments demonstrated smaller root mean square errors in terms of kinematics (0.7900° +/− 0.4081°) than models integrating a Blankevoort representation (1.4704° +/− 0.8007°). A novel computational workflow integrating subject-specific, experimentally calibrated HGO predicted post-TKA frontal-plane knee joint laxity with clinically applicable accuracy. Generally, errors in terms of tibial rotation were higher and might be further reduced by increasing the interaction nodes between the rigid body model and the finite element software. Future work should investigate the accuracy of resulting models for simulating unseen activities of daily living


Bone & Joint Research
Vol. 8, Issue 11 | Pages 509 - 517
1 Nov 2019
Kang K Koh Y Park K Choi C Jung M Shin J Kim S

Objectives. The aim of this study was to investigate the biomechanical effect of the anterolateral ligament (ALL), anterior cruciate ligament (ACL), or both ALL and ACL on kinematics under dynamic loading conditions using dynamic simulation subject-specific knee models. Methods. Five subject-specific musculoskeletal models were validated with computationally predicted muscle activation, electromyography data, and previous experimental data to analyze effects of the ALL and ACL on knee kinematics under gait and squat loading conditions. Results. Anterior translation (AT) significantly increased with deficiency of the ACL, ALL, or both structures under gait cycle loading. Internal rotation (IR) significantly increased with deficiency of both the ACL and ALL under gait and squat loading conditions. However, the deficiency of ALL was not significant in the increase of AT, but it was significant in the increase of IR under the squat loading condition. Conclusion. The results of this study confirm that the ALL is an important lateral knee structure for knee joint stability. The ALL is a secondary stabilizer relative to the ACL under simulated gait and squat loading conditions. Cite this article: Bone Joint Res 2019;8:509–517


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 58 - 58
11 Apr 2023
Jansen M Salzlechner C Barnes E DiFranco M Custers R Watt F Vincent T Lafeber F Mastbergen S
Full Access

Knee joint distraction (KJD) has been associated with clinical and structural improvement and synovial fluid (SF) marker changes. However, structural changes have not yet been shown satisfactorily in regular care, since radiographic acquisition was not fully standardized. AI-based modules have shown great potential to reduce reading time, increase inter-reader agreement and therefore function as a tool for treatment outcome assessment. The objective was to analyse structural changes after KJD in patients using this AI-based measurement method, and relate these changes to clinical outcome and SF markers. 20 knee OA patients (<65 years old) were included in this study. KJD treatment was performed using an external fixation device, providing 5 mm distraction for 6 weeks. SF was aspirated before, during and immediately after treatment. Weight-bearing antero-posterior knee radiographs and WOMAC questionnaires were collected before and ~one year after treatment. Radiographs were analysed with the Knee Osteoarthritis Labelling Assistant (KOALA, IB Lab GmbH, Vienna, Austria), and 10 pre-defined biomarker levels in SF were measured by immunoassay. Radiographic one-year changes were analysed and linear regression was used to calculate associations between changes in standardized joint space width (JSW) and WOMAC, and changes in JSW and SF markers. After treatment, radiographs showed an improvement in Kellgren-Lawrence grade in 7 of 16 patients that could be evaluated; 3 showed a worsening. Joint space narrowing scores and continuous JSW measures improved especially medially. A greater improvement in JSW was significantly associated with a greater improvement in WOMAC pain (β=0.64;p=0.020). A greater increase in MCP1 (β=0.67;p=0.033) and lower increase in TGFβ1 (β=-0.787;p=0.007) were associated with JSW improvement. Despite the small number of patients, also in regular care KJD treatment shows joint repair as measured automatically on radiographs, significantly associated with certain SF marker change and even with clinical outcome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 149 - 149
4 Apr 2023
Killen B Willems M Hoang H Verschueren S Jonkers I
Full Access

The aim of this research was to determine biomechanical markers which differentiate medial knee osteoarthritis (OA) patients who do and do not show structural progression over a 2-year period. A cohort of 36 subjects was selected from a longitudinal study (Meireles et al 2017) using Kellgren-Lawrence (KL) scores at baseline and 2-year follow-up. The cohort consisted of 10 healthy controls (HC) (KL=0 at both time points), 15 medial knee OA non-progressors (NPKOA) (KL≥1 at baseline and no change over 2 years), and 11 medial knee OA progressors (PKOA) (KL≥1 at baseline and increase of ≥1 over 2 years). 3D integrated motion capture data from three walking trials were processed through a musculoskeletal modelling framework (Smith et al 2016) to estimate knee joint loading parameters (i.e., magnitude of mean contact pressure, and centre of pressure (COP)). Parameters at first and second peak were extracted and compared between groups using Kruskal-Wallis and Mann-Whitney tests. Higher magnitudes were observed in PKOA vs NPKOA, and PKOA vs HC groups at both time points. Additionally, a posterior (1st and 2nd peak), and lateral (2nd peak) shift in medial compartment COP was shown between PKOA and NPKOA, and PKOA and HC subjects. Interestingly, in the studied parameters, no differences were observed between NPKOA and HC groups. Significantly higher magnitude, and a more posterior and lateral COP was observed between PKOA and NPKOA patients. These differences, combined with an absence of difference between NPKOA and HC suggest structural OA progression is driven by a combination of altered loading magnitude and location. These results may serve as guidelines for targeted gait retraining rehabilitation to slow or stop knee OA progression whereby shifting COP anterior and medial and reducing magnitude by ~22% may shift patients from a PKOA to a NPKOA trajectory


Bone & Joint 360
Vol. 12, Issue 5 | Pages 18 - 21
1 Oct 2023

The October 2023 Knee Roundup. 360. looks at: Cementless total knee arthroplasty is associated with more revisions within a year; Kinematically and mechanically aligned total knee arthroplasties: long-term follow-up; Aspirin thromboprophylaxis following primary total knee arthroplasty is associated with a lower rate of early periprosthetic joint infection compared with other agents; The impact of a revision arthroplasty network on patient outcomes; Re-revision knee arthroplasty in a tertiary centre: how does infection impact on outcomes?; Does the knee joint have its own microbiome?; Revision knee surgery provision in Scotland; Aspirin is a safe and effective thromboembolic prophylaxis after total knee arthroplasty: a systematic review and meta-analysis; Patellar resurfacing and kneeling ability after total knee arthroplasty: a systematic review


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 61 - 61
1 Jul 2022
Wang D Willinger L Athwal K Williams A Amis A
Full Access

Abstract. Background. Little scientific evidence is available regarding the effect of knee joint line obliquity (JLO). Methods. 10 fresh-frozen human cadaveric knees were axially loaded to 1500 N in a materials testing machine with the joint line tilted 0, 4, 8, and 12 degrees varus and valgus, at 0, and 20 degrees of knee flexion. The mechanical compression axis was aligned to the centre of the tibial plateau. Contact pressures / areas were recorded by sensors inserted between the tibia and femur below the menisci. Changes in relative femoral and tibial position in the coronal plane were obtained by an optical tracking system. Results. medial and lateral JLO caused significant tibiofemoral subluxation and pressure distribution changes. Medial (varus) JLO caused the femur to sublux medially down the coronal slope of the tibial plateau, and vice versa for lateral (valgus) downslopes (P=0.01). Areas of peak pressure moved 12 mm and 8 mm across the medial and lateral condyles, onto the ‘downhill’ meniscus and the ‘uphill’ tibial spine. Changes in JLO had only small effects on maximum contact pressures. Conclusion. A change of JLO during load bearing caused significant mediolateral tibiofemoral subluxation. The femur slid down the slope of the tibial plateau to abut the tibial eminence and also to rest on the downhill meniscus. Clinical Relevance. These results provide important information for understanding the consequences of creating coronal JLO and for clinical practice in terms of osteotomy planning regarding the effect on JLO


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1363 - 1368
1 Dec 2024
Chen DB Wood JA Griffiths-Jones W Bellemans J Haddad FS MacDessi SJ

As advancements in total knee arthroplasty progress at an exciting pace, two areas are of special interest, as they directly impact implant design and surgical decision making. Knee morphometry considers the three-dimensional shape of the articulating surfaces within the knee joint, and knee phenotyping provides the ability to categorize alignment into practical groupings that can be used in both clinical and research settings. This annotation discusses the details of these concepts, and the ways in which they are helping us better understand the individual subtleties of each patient’s knee. Cite this article: Bone Joint J 2024;106-B(12):1363–1368


Bone & Joint Research
Vol. 12, Issue 3 | Pages 179 - 188
7 Mar 2023
Itoh M Itou J Imai S Okazaki K Iwasaki K

Aims. Orthopaedic surgery requires grafts with sufficient mechanical strength. For this purpose, decellularized tissue is an available option that lacks the complications of autologous tissue. However, it is not widely used in orthopaedic surgeries. This study investigated clinical trials of the use of decellularized tissue grafts in orthopaedic surgery. Methods. Using the ClinicalTrials.gov (CTG) and the International Clinical Trials Registry Platform (ICTRP) databases, we comprehensively surveyed clinical trials of decellularized tissue use in orthopaedic surgeries registered before 1 September 2022. We evaluated the clinical results, tissue processing methods, and commercial availability of the identified products using academic literature databases and manufacturers’ websites. Results. We initially identified 4,402 clinical trials, 27 of which were eligible for inclusion and analysis, including nine shoulder surgery trials, eight knee surgery trials, two ankle surgery trials, two hand surgery trials, and six peripheral nerve graft trials. Nine of the trials were completed. We identified only one product that will be commercially available for use in knee surgery with significant mechanical load resistance. Peracetic acid and gamma irradiation were frequently used for sterilization. Conclusion. Despite the demand for decellularized tissue, few decellularized tissue products are currently commercially available, particularly for the knee joint. To be viable in orthopaedic surgery, decellularized tissue must exhibit biocompatibility and mechanical strength, and these requirements are challenging for the clinical application of decellularized tissue. However, the variety of available decellularized products has recently increased. Therefore, decellularized grafts may become a promising option in orthopaedic surgery. Cite this article: Bone Joint Res 2023;12(3):179–188


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 42 - 42
1 Feb 2020
Innocenti B Bori E Paszicsnyek T
Full Access

INTRODUCTION. Applying the proper amount of tension to knees collateral ligaments during surgery is a prerequisite to achieve optimal performance after TKA. It must be taken into account that lower values of ligament tension could lead to an instable joint while higher values could induce over-tensioning thus leading to problems at later follow-up: a “functional stability” must then be defined and achieved to guarantee the best results. In this study, an experimental cadaveric activity was performed to measure the minimum tension required to achieve functional stability in the knee joint. METHODS. Ten cadaveric knee specimens were investigated; each femur and tibia was fixed with polyurethane foam in specific designed 3D-printed fixtures and clamped to a loading frame. A constant displacement rate of 0.05 mm/s was applied to the femoral clamp in order to achieve joint stability and the relative force was measured by the machine: the lowest force guaranteeing joint stability was then determined to be the one corresponding to the slope change in the force/displacement curve, representing the activation of the elastic region of both collateral ligaments. The force span between the slack region and the found point was considered to be the tension required to reach the functional stability of the joint. This methodology was applied on intact knee, after ACL-resection and after further PCL-resection in order to simulate the knee behavior in CR and PS implants. The test was performed at 0, 30, 60 and 90° of flexion using a specifically designed device. Each configuration was analyzed three times for the sake of repeatability. RESULTS. Results demonstrated that an overall tension of 40–50N is sufficient to reach stability in native knee with intact cruciate ligaments. Similar values appear to be sufficient in an ACL-resected knee, while higher tension is required (up to 60N) for stability after ACL and PCL resection. Moreover, the tension required for stabilization was slightly higher at 60° of flexion compared to the one required at the other angles, reflecting thus the mid-flection instability behavior. DISCUSSION AND CONCLUSIONS. The results are in agreement to other experimental studies. 1,2. and show that the tensions necessary to stabilize a knee joint in different ligament conditions are way lower than the ones usually applied via tensioners nowadays. To reach functional stability, surgeons should consider such results intraoperatively to avoid laxity, mid-flexion instability or ligament over-tension


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 4 - 4
2 Jan 2024
Han S Yoo Y Choi H Lee K Korhonen R Esrafilian A
Full Access

It is known that the gait dynamics of elderly substantially differs from that of young people. However, it has not been well studied how this age-related gait dynamics affects the knee biomechanics, e.g., cartilage mechanical response. In this study, we investigated how aging affects knee biomechanics in a female population using subject-specific computational models.

Two female subjects (ages of 23 and 69) with no musculoskeletal disorders were recruited. Korea National Institute for Bioethics Policy Review Board approved the study. Participants walked at a self-selected speed (SWS), 110% of SWS, and 120% of SWS on 10 m flat ground. Three-dimensional marker trajectories and ground reaction forces (Motion Analysis, USA), and lower limbs’ muscle activities were measured (EMG, Noraxon USA). Knee cartilage and menisci geometries were obtained from subjects’ magnetic resonance images (3T, GE Health Care). An EMG-assisted musculoskeletal finite element modeling workflow was used to estimate knee cartilage tissue mechanics in walking trials. Knee cartilage and menisci were modeled using a transversely isotropic poroviscoelastic material model.

Walking speed in SWS, 110%, and 120% of SWS were 1.38 m/s, 1.51 m/s, and 1.65 m/s for the young, and 1.21 m/s, 1.34 m/s and 1.46 m/s for the elderly, respectively. The maximum tensile stress in the elderly tibial cartilage was ~25%, ~33%, and ~32% lower than the young at SWS, 110%, and 120% of SWS, respectively. These preliminary results suggest that the cartilage in the elderly may not have enough stimulation even at 20% increases in walking speed, which may be one reason for tissue degeneration. To enhance these findings, further study with more subjects and different genders will investigate how age-related gait dynamics affects knee biomechanics.

Acknowledgments: Australian NHMRC Ideas Grant (APP2001734), KITECH (JE220006)


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1168 - 1173
1 Oct 2022
Gazendam AM Schneider P Vélez R Ghert M

Aims. The aim of this study was to determine the prevalence and impact of tourniquet use in patients undergoing limb salvage surgery with endoprosthetic reconstruction for a tumour around the knee. Methods. We retrieved data from the Prophylactic Antibiotic Regimens in Tumor Surgery (PARITY) trial; specifically, differences in baseline characteristics, surgical details, and postoperative functional outcomes between patients who had undergone surgery under tourniquet and those who had not. A linear regression model was created to evaluate the impact of tourniquet use on postoperative Toronto Extremity Salvage Scores (TESSs) while controlling for confounding variables. A negative-binomial regression model was constructed to explore predictors of postoperative length of stay (LOS). Results. Of the 604 patients enrolled in the PARITY trial, 421 had tumours around the knee joint, of whom 225 (53%) underwent surgery under tourniquet. The tourniquet group was younger (p = 0.014), more likely to undergo surgery for a tumour of the tibia, and had shorter operating times by a mean of 50 minutes (95% confidence interval 30 to 72; p < 0.001). The adjusted linear regression model found that the use of a tourniquet, a shorter operating time, and a higher baseline TESS independently predicted better function at both three- and six-month follow-up. The negative-binomial regression model showed that tourniquet use, shorter operating time, younger age, and intraoperative tranexamic acid administration independently predicted a shorter LOS in hospital. Conclusion. The results of this study show that in patients undergoing resection of a tumour around the knee and endoprosthetic reconstruction, the use of an intraoperative tourniquet is associated with a shorter operating time, a reduced length of stay in hospital, and a better early functional outcome. Cite this article: Bone Joint J 2022;104-B(10):1168–1173


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 122 - 122
1 Mar 2021
Teunissen M Popov-Celeketic J Coeleveld K Meij BP Lafeber F Tryfonidou MA Mastbergen SC
Full Access

Knee joint distraction (KJD) is a joint-preserving treatment strategy for severe osteoarthritis (OA) that provides long-term clinical and structural improvement. Data from both human trials and animal models indicate clear cartilage regeneration from 6 months and onwards post-KJD. However, recent work showed that during distraction, the balance between catabolic and anabolic indicators is directed towards catabolism, as indicated by collagen type 2 markers, proteoglycan (PG) turnover and a catabolic transcription profile [unpublished data]. The focus of this study was to investigate the cartilage directly and 10 weeks after joint distraction in order to elucidate the shift from a catabolic to an anabolic cartilage state. Knee OA was induced bilaterally in 8 dogs according to the groove model. After 10 weeks of OA induction, all 8 animals received right knee joint distraction, employing the left knee as an OA control. After 8 weeks of distraction, 4 dogs were euthanized and after 10 weeks of follow-up the 4 other dogs. Macroscopic cartilage degeneration and synovial tissue inflammation was assessed using the OARSI canine scoring system. PG content was determined spectrometrically using Alcian Blue dye solution and the synthesis of newly formed PGs was determined using . 35. SO. 4. 2-. as a tracer, as was described before. Directly after KJD, macroscopic cartilage damage of the right tibial plateau was higher compared to the left OA control (OARSI score: 1.7±0.2 vs 0.6±0.3; p < 0.001). 10 weeks post-KJD this difference persisted (OARSI score: 1.4± 0.6 vs 0.6±0.3; p = 0.05). Directly after KJD, there was no difference in synovial inflammation between KJD and OA control (OARSI score: 1.4±0.5). At 10 weeks synovial inflammation increased significantly in the distracted knee (OARSI score: 2.1±0.3 vs 1.4±0.5; p < 0.05). Biochemical analysis of the tibia cartilage directly after KJD revealed a lower PG content (20.1±10.3 mg/g vs 23.7±11.7 mg/g). At 10 weeks post-KJD this difference in PG content was less (24.8±6.8 mg/g vs 25.4±7.8 mg/g). The PG synthesis rate directly after KJD appeared significantly lower vs. OA (1.4±0.6 nmol/h.g vs 5.9±4.4 nmol/h.g; p < 0.001)). However, 10 weeks post-KJD this difference was not detected (3.7±1.2 nmol/h.g vs 2.9±0.8 nmol/h.g), and the synthesis rate in the distracted knee was increased compared to directly after distraction (p < 0.01). Further in-depth investigation of the material is ongoing; these first results suggest that the shift from a catabolic to an anabolic state occurs within the first weeks after joint distraction, mostly reflected in the biochemical changes. As such, the post-distraction period seems to be essential in identifying key-players that support intrinsic cartilage repair


Bone & Joint Research
Vol. 12, Issue 12 | Pages 702 - 711
1 Dec 2023
Xue Y Zhou L Wang J

Aims

Knee osteoarthritis (OA) involves a variety of tissues in the joint. Gene expression profiles in different tissues are of great importance in order to understand OA.

Methods

First, we obtained gene expression profiles of cartilage, synovium, subchondral bone, and meniscus from the Gene Expression Omnibus (GEO). Several datasets were standardized by merging and removing batch effects. Then, we used unsupervised clustering to divide OA into three subtypes. The gene ontology and pathway enrichment of three subtypes were analyzed. CIBERSORT was used to evaluate the infiltration of immune cells in different subtypes. Finally, OA-related genes were obtained from the Molecular Signatures Database for validation, and diagnostic markers were screened according to clinical characteristics. Quantitative reverse transcription polymerase chain reaction (qRT‐PCR) was used to verify the effectiveness of markers.


Bone & Joint Research
Vol. 13, Issue 7 | Pages 353 - 361
10 Jul 2024
Gardete-Hartmann S Mitterer JA Sebastian S Frank BJH Simon S Huber S Löw M Sommer I Prinz M Halabi M Hofstaetter JG

Aims. This study aimed to evaluate the BioFire Joint Infection (JI) Panel in cases of hip and knee periprosthetic joint infection (PJI) where conventional microbiology is unclear, and to assess its role as a complementary intraoperative diagnostic tool. Methods. Five groups representing common microbiological scenarios in hip and knee revision arthroplasty were selected from our arthroplasty registry, prospectively maintained PJI databases, and biobank: 1) unexpected-negative cultures (UNCs), 2) unexpected-positive cultures (UPCs), 3) single-positive intraoperative cultures (SPCs), and 4) clearly septic and 5) aseptic cases. In total, 268 archived synovial fluid samples from 195 patients who underwent acute/chronic revision total hip or knee arthroplasty were included. Cases were classified according to the International Consensus Meeting 2018 criteria. JI panel evaluation of synovial fluid was performed, and the results were compared with cultures. Results. The JI panel detected microorganisms in 7/48 (14.5%) and 15/67 (22.4%) cases related to UNCs and SPCs, respectively, but not in cases of UPCs. The correlation between JI panel detection and infection classification criteria for early/late acute and chronic PJI was 46.6%, 73%, and 40%, respectively. Overall, the JI panel identified 12.6% additional microorganisms and three new species. The JI panel pathogen identification showed a sensitivity and specificity of 41.4% (95% confidence interval (CI) 33.7 to 49.5) and 91.1% (95% CI 84.7 to 94.9), respectively. In total, 19/195 (9.7%) could have been managed differently and more accurately upon JI panel evaluation. Conclusion. Despite its microbial limitation, JI panel demonstrated clinical usefulness by complementing the traditional methods based on multiple cultures, particularly in PJI with unclear microbiological results. Cite this article: Bone Joint Res 2024;13(7):353–361


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 4 - 4
1 Dec 2021
J⊘rgensen AR Hanberg P Bue M Thomassen MB J⊘rgensen N Stilling M
Full Access

Aim. This study evaluated target tissue concentrations of double dose cefuroxime administered intravenously as either one 15 min infusion of 3,000 mg (Group 1) or two single 15 min infusions of 1,500 mg administered 4 h apart (Group 2). Method. Sixteen pigs were randomised into two groups of eight. Cortical and cancellous bone, synovial fluid of the knee joint and subcutaneous adipose tissue concentrations were measured based on sampling via microdialysis. Plasma samples were collected as a reference. Comparison of the groups was based on time with concentrations above relevant minimal inhibitory concentrations (fT>MIC) of 4 μg/mL. Results. The mean time fT>MIC (4 μg/mL) across compartments was longer for Group 2 (280–394 min) than for Group 1 (207–253 min) (p<0.01). Cortical bone showed a tendency towards longer fT>MIC (4 μg/mL) in Group 2 (280 min) than in Group 1 (207 min) (p=0.053). Within 50 min after administration, the mean concentration of 4 μg/mL was reached in all compartments for both groups. The mean concentrations decreased below 4 μg/mL after approximately 4 h (Group 1) and 3 h (Group 2) from initiation of administration (time zero). Conclusions. During an 8 h interval, double-dose cefuroxime administered as 2 × 1,500 mg with a 4 h interval provides longer time above MIC breakpoint for Staphylococcus aureus (4 μg/mL) than a single bolus of 3,000 mg cefuroxime. To maintain sufficient tissue concentrations during longer surgeries, re-administration of cefuroxime (1,500 mg) should be considered 3 h after the first administration