Background. One of the basic principles in the primary survey of a trauma patient is immobilisation of the cervical spine till cleared of any injury.
This study aims to implement and assess the inter and intra-reliability of a modernised radiolucency assessment system; the Radiolucency In cemented Stemmed Knee (RISK) arthroplasty classification. Furthermore, we assessed the distribution of regions affected by radiolucency in patients undergoing stemmed cemented knee arthroplasty. Stemmed knee arthroplasty cases over 7-year period at a single institution were retrospectively identified and reviewed. The RISK classification system identifies five zones in the femur and five zones in the tibia in both the anteroposterior (AP) and lateral planes. Post-operative and follow-up radiographs were scored for radiolucency by four blinded reviewers at two distinct time points four weeks apart. Reliability was assessed using the kappa statistic. A heat map was generated to demonstrate the reported regions of radiolucency. 29 cases (63 radiographs) of stemmed knee arthroplasty were examined radiographically using the RISK system. Intra-reliability (0.83) and Inter-reliability (0.80) scores were both consistent with a strong level of agreement using the kappa scoring system. Radiolucency was more commonly associated with the tibial component (76.6%) compared to the femoral component (23.3%), and the tibial anterior-posterior (AP) region 1 (medial plateau) was the most affected (14.9%). The RISK classification system is a reliable assessment tool for evaluating radiolucency around stemmed knee arthroplasty using defined zones on both AP and
Introduction. Recent technological advancements have led to the introduction of robotic-assisted total knee arthroplasty to improve the accuracy and precision of bony resections and implant position. However, the in vivo accuracy is not widely reported. The primary objective of this study is to determine the accuracy and precision of a cut block positioning robotic arm. Method. Seventy-seven patients underwent total knee arthroplasty with various workflows and alignment targets by three arthroplasty-trained surgeons with previous experience using the ROSA® Knee System. Accuracy and precision were determined by measuring the difference between various workflow time points, including the final pre-operative plan, validated resection angle, and post-operative radiographs. The mean difference between the measurements determined accuracy, and the standard deviation represented precision. Results. The accuracy and precision for all angles comparing the final planned resection and validated resection angles was 0.90° ± 0.76°. The proportion within 3° ranged from 97.9% to 100%. The accuracy and precision for all angles comparing the final intra- operative plan and post-operative radiographs was 1.95 ± 1.48°. The proportion of patients within 3° was 93.2%, 95.3%, 96.6%, and 71.4% for the distal femur, proximal tibia, femoral flexion, and tibial slope angles when the final intra-operative plan was compared to post-operative radiographs. No patients had a postoperative complication requiring revision at the final follow-up. Conclusions. This study demonstrates that the ROSA Knee System has accurate and precise coronal plane resections with few outliers. However, the tibial slope demonstrated decreased accuracy and precision were measured on post-operative short-leg
Long femoral nails for neck of femur fractures and prophylactic fixation have a risk of anterior cortex perforation. Previous studies have demonstrated the radius of curvature (ROC) of a femoral nail influencing the finishing point of a nail and the risk of anterior cortex perforation. This study aims to calculate a patients femoral ROC using preoperative XR and CT and therefore nail finishing position. We conducted a retrospective study review of patients with long femoral cephalomedullary nailing for proximal femur fractures (OTA/AO 31(A) and OTA/AO 32) or impending pathological fractures at a level 1 trauma centre between January 1, 2015 and December 31, 2020 with both full length
The purpose of this study is to evaluate risk factors for distal construct failure (DCF) in posterior spinal instrumented fusion (PSIF) in adolescent idiopathic scoliosis (AIS). We observed an increased rate of DCF when the pedicle screw in the lowest instrumented vertebra (LIV) was not parallel to the superior endplate of the LIV, however this has not been well studied in the literature. We hypothesise a more inferiorly angled LIV screw predisposes to failure and aim to find the critical angle that predisposes to failure. A retrospective cohort study was performed on all patients who underwent PSIF for AIS at the Starship Hospital spine unit from 2010 to 2020. On a
A stiff spine leads to increased demand on the hip, creating an increased risk of total hip arthroplasty (THA) dislocation. Several authors propose that a change in sacral slope of ≤10° between the standing and relaxed-seated positions (ΔSSstanding→relaxed-seated) identifies a patient with a stiff lumbar spine and have suggested use of dual-mobility bearings for such patients. However, such assessment may not adequately test the lumbar spine to draw such conclusions. The aim of this study was to assess how accurately ΔSSstanding→relaxed-seated can identify patients with a stiff spine. This is a prospective, multi-centre, consecutive cohort series. Two-hundred and twenty-four patients, pre-THA, had standing, relaxed-seated and flexed-seated
The spinopelvic alignment is often assessed via the Pelvic Incidence-Lumbar Lordosis (PI-LL) mismatch. Here we describe and validate a simplified method to evaluating the spinopelvic alignment through the L1-Pelvis angle (L1P). This method is set to reduce the operator error and make the on-film measurement more practicable. 126 standing
Evaluation of patient specific spinopelvic mobility requires the detection of bony landmarks in
The presence of hip osteoarthritis is associated with abnormal spinopelvic characteristics. This study aims to determine whether the pre-operative, pathological spinopelvic characteristics “normalize” at 1-year post-THA. This is a prospective, longitudinal, case-control matched cohort study. Forty-seven patients underwent pre- and post- (at one-year) THA assessments. This group was matched (age, sex, BMI) with 47 controls/volunteers with well-functioning hips. All participants underwent clinical and radiographic assessments including
Internal fixation is currently the standard of care for Garden I and II femoral neck fractures in the elderly. However, there may be a degree of posterior tilt on the preoperative
Recent analyses of failure mechanisms continue to show aseptic loosening as the predominant mechanism of total knee arthroplasty (TKA) failure. Evaluation for aseptic loosening begins with careful assessment of plain films radiographs, however the utility of examining lucent lines under a cemented tibial tray remains unclear. The purpose of this study is to examine the distribution of lucent lines under cemented tibial components on single-series anteroposterior (AP) and
The functional pelvic tilt when standing and sitting forward of 7402 cases on the OPS, Optimized Ortho, Australia Data Base were reviewed. All patients had undergone
Introduction. The effect of the implant posterior condylar offset has recently generated much enthusiasm among researchers. Some reports were concerned about the relationship between the posterior condylar offset and an extension gap. However, the posterior condylar offset was measured in a flexed knee position or in reference to femoral anatomy alone. Posterior femoral condylar offset relative to the posterior wall of the tibia (posterior offset ratio; POR) is possibly the risk of knee flexion contracture associated with posterior femoral condylar offset after TKA. However, there are no reports concerning the relationship between POR and flexion contracture in vivo. The aim of this study is to evaluate the relationship between the measurement of POR and flexion contracture of the knee in vivo. Methods. Twenty-seven patients who underwent a primary total knee arthroplasty (PFC Sigma RP-F) were participated in the study. The lateral femoro-tibial angle (lateral FTA) was measured using
Introduction:. The
Background. The adult acquired flat foot is caused by a complete or partial tear of the tibialis posterior tendon. We present the results of flexor digitorum longus transfer and medializing calcaneal osteotomy for recontruction of the deformity. Material & Methods. Twenty-six patients (31 feet) with an average age of 58 years (36–75) were operated for an acquired flat foot deformity. The patients were seen before surgery, one year after surgery and an average of 85 months after surgery to assess the following parameters: AOFAS Score, VAS Score for pain (0–10). Foot x-rays in full weightbearing position (dorsoplantar and lateral) were done at every visit in order to assess the following parameters: tarsometatarsale angle on the dorsoplantar and
The best algorithm, measurements, and criteria for screening children with Down syndrome for upper cervical instability are controversial. Many authors have recommended obtaining flexion and extension views. We noted that patients who require surgical stabilization due to myelopathy or cord compression typically have grossly abnormal radiographic measurements on the neutral upright
Spinopelvic mobility describes the change in lumbar lordosis and pelvic tilt from standing to sitting position. For 1° of posterior pelvic tilt, functional cup anteversion increases by 0.75° after total hip arthroplasty (THA). Thus, spinopelvic mobility is of high clinical relevance regarding the risk of implant impingement and dislocation. Our study aimed to 1) determine the proportion of OA-patients with stiff, normal or hypermobile spino-pelvic mobility and 2) to identify clinical or static standing radiographic parameters predicting spinopelvic mobility. This prospective diagnostic cohort study followed 122 consecutive patients with end-stage osteoarthritis awaiting THA. Preoperatively, the Oxford Hip Score, Oswestry Disability Index and Schober's test were assessed in a standardized clinical examination.
Introduction. Interactions between hip, pelvis and spine, as abnormal spinopelvic movements, have been associated with inferior outcomes following total hip arthroplasty (THA). Changes in pelvis position lead to a mutual change in functional cup orientation, with both pelvic tilt and rotation having a significant effect on version. Hip osteoarthritis (OA) patients have shown reduced hip kinematics which may place increased demands on the pelvis and the spine. Sagittal and coronal planes assessments are commonly done as these can be adequately studied with anteroposterior and
Dorr bone type is both a qualitative and quantitative classification. Qualitatively on x-rays the cortical thickness determines the ABC type. The cortical thickness is best judged on a
Total Elbow Replacements are indicated for pain and disability in patients with rheumatoid and osteoarthritis of the elbow. The quality of the cementation has been specifically studied and shown to be directly related to the clinical outcome and implant survival. Aim. The aim of our study is to radiologically assess and grade the cementation around the components following total elbow replacement (GSB 3 or Coonrad Morrey) in two groups of patients. Materials and methods. Group I underwent total elbow replacement using Heraeus cement gun with medium palacos viscosity cement and group 2 using Zimmer cement gun with simplex medium viscosity cement. Average age in Group 1 was 72.3 (range 67–88 yrs) and group 2 was 69 years (range 52–87 yrs). 3 Coonrad Morrey and 13 GSB 3 total elbow replacement were used in Group 1 and 2 Coonrad Morrey and 14 GSB 3 in group 2. The primary indication for surgery was osteoarthritis, rheumatoid arthritis, post traumatic arthritis and seronegative arthritis in both groups. The cementation was assessed radiologically using three grading system (Morrey, Gerber & Bristol). Results. In Group I (Heraeus) 14 had adequete cementation in both AP and