This study was conducted to investigate the characteristics, complications, radiologic features and clinical course of patients undergoing reduction of forearm fractures in order to better inform patient prognosis and postoperative management. We conducted a retrospective cohort study of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. A preoperative radiological assessment and chart review was performed. Percent fracture displacement, location, orientation, comonution, fracture line visibility and angle of angulation were determined by AP and
Malalignment is often postulated as the main reason for the high failure rate of total ankle replacements (TARs). Only a few studies have been performed to correlate radiographic TAR malalignment to the clinical outcome, but no consistent trends between TAR alignment parameters and the clinical outcome were found. No standard TAR alignment measurement method is present, so reliable comparison between studies is difficult. Standardizing TAR alignment measurements and increasing measurable parameters on radiographs in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurement on radiographs in the clinic. A tool to semi-automatically measure TAR alignment on anteroposterior and
Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization. We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation, comminution, fracture line visibility and angle of angulation were determined by AP and
Fracture healing is an issue that has not yet been fully elucidated. It is generally accepted in the literature that head trauma accelerates fracture healing and causes higher volume callus tissue. Recent studies have examined the relationship between head trauma and fracture healing more molecularly. Based on this research; the aim of this study is to show the effect of head trauma on fracture healing radiologically and histologically and to investigate the relationship between serum β-Catenin level and fracture healing with the experiment we performed on rats. A total of 36 Wistar Albino female rats with a mean age of 24 weeks were included in the study with the permission of Mersin University Animal Experiments Local Ethics Committee. Six rats in the first group were not traumatized and their blood samples were collected on the day of the experiment started, end of the third week and end of the sixth week. In the second group, only head trauma was performed and blood samples were collected at the end of the third and sixth weeks. In the third group, only open femoral fracture model was applied, blood samples were collected at the third and sixth weeks and AP and
Introduction and Objective. Up to 30% of thoracolumbar (TL) fractures are missed in the emergency room. Failure to identify these fractures can result in neurological injuries up to 51% of the casesthis article aimed to clarify the incidence and risk factors of traumatic fractures in China. The China National Fracture Study (CNFS. Obtaining sagittal and anteroposterior radiographs of the TL spine are the first diagnostic step when suspecting a traumatic injury. In most cases, CT and/or MRI are needed to confirm the diagnosis. These are time and resource consuming. Thus, reliably detecting vertebral fractures in simple radiographic projections would have a significant impact. We aim to develop and validate a deep learning tool capable of detecting TL fractures on
Appropriate in vivo models can be used to understand atrophic non-union pathophysiology. In these models, X-ray assessment is essential and a reliable good quality images are vital in order to detect any hidden callus formation or deficiency. However, the radiographic results are often variable and highly dependent on rotation and positioning from the detector/film. Therefore, standardised A-P and
Background. Plate fixation is one of several options available to surgeons for the management of pediatric femur fractures. Recent literature reports distal femoral valgus can be a complication following lateral plate fixation of femur fractures. We report on a case of extreme distal femoral valgus deformity and a lateral dislocation of the patella four years after having plate fixation of a left distal femoral fracture. Method. A single case was anonymised and retrospectively reviewed through examination of clinical and radiographic data. Results. A 15 year old male presented with 35 degree femoral valgus deformity, one inch leg length discrepancy, painful retained hardware and a lateral dislocation of the patella four years after undergoing lateral plate fixation of a left distal femur fracture. The fracture site healed after plate insertion, but later the patient reported worsening in alignment of lower extremity and complained of pain in the limb. Antero-posterior and
The CCI mobile bearing ankle implant used at our orthopedic department 2010–2013, was abandoned due to failures and findings of bone loss at revision. The aim of this study was to a) Determine our true revision rate, b) Investigate accuracy of measuring prevalence, size and location of periprosthetic bone cysts through X-ray and CT and c) Relate these findings to implant alignment and patient reported outcome measurements (PROMs). 51 primary surgeries were performed, prior to this study 8 had been revised. Out of 43 un-revised patients, 36 were enrolled and underwent evaluation with metal artefact reduction CT-scans and conventional X-ray. They filled out 3 PROMs; SEFAS, SF-12, EQ-5D. Cyst volume larger than 0.1 ml was measured using VITREA volume tools for CT-scans and calculation of spherical volume for X-rays; using AP- and lateral projections. Location of lesions was recorded, according to their position relative to the implant. Medial-/lateral- and anterior-/posterior tilt of the implant parts was measured using IMPAX built in measuring tools, applied to AP- and
Introduction and Aims. Peritrochanteric femur fractures are common and impose major costs on the healthcare system. A fixed angle sliding hip screw is the principle method of treatment, but the rate of mechanical failure associated with these devices can be high; the usual mechanism being the collapse of the neck shaft angle leading to extrusion of the screw from the femoral head, commonly known as “cutout”. Many variables contribute to the risk of cutout, however there is substantial evidence that the “Tip Apex Distance” (a single number that summarises the position and depth of the lag screw on anteroposterior and
Summary Statement. Novel radiopaque UHMWPE sublaminar cables may be a promising alternative to gliding pedicle screws or titanium sublaminar cables within a growth-guidance system for the surgical treatment of early onset scoliosis. Introduction. Growth-guidance or self-lengthening rod systems are an alternative to subcutaneous growing rods and the vertical expandable prosthetic titanium rib for the treatment of early onset scoliosis. Their main perceived advantage over growing rods is the marked decrease in subsequent operative procedures. The Shilla growth-guidance system and a modern Luque trolley are examples of such systems; both depend on gliding pedicle screws and/or sliding titanium sublaminar wires. However, the unknown consequences of metal-on-metal wear debris are reason for concern especially in young patients. In this study, instrumentation stability, residual growth in the operated segment after surgery and biocompatibility of the novel radiopaque UHMWPE cables as an alternative to gliding pedicles screws or titanium sublaminar wires were assessed in an immature sheep model. Materials and methods. Twelve immature sheep were treated with segmental sublaminar spinal instrumentation: dual CoCr rods were held in place by pedicle screws at the most caudal instrumented level (L5) and novel radiopaque UHMWPE (Bi. 2. O. 3. additive) woven cables were placed at 5 thoracolumbar levels.
Introduction. Primary Total Elbow Replacement (TER) is gaining popularity as a primary treatment option for osteoporotic fractures of the elbow, particularly in patients with low demand. The aim of this study was to assess the clinical and functional efficacy of TER as a primary treatment for comminuted distal humerus fractures in the elderly. Methods. We retrospectively reviewed twenty-three patients (22 females and 1 male) who were treated with primary total elbow replacement for complex, intra-articular fractures of the distal humerus in the elderly between March 2000 and January 2010. The average age of the patients was seventy-five years (ranging from 66 to 94 years). Postoperative elbow function was assessed using the Mayo Elbow Performance Score. The radiological assessment was performed using antero-posterior and
Background. Posterolateral fusion (PLF) is a commonly accepted surgical procedure and overall the most common technique performed to obtain fusion in the lumbar spine. Harvesting autologous bone from the iliac crest is associated with increased operation time, blood loss, and chronic donor site pain. Allograft material has an insufficient osteoinductive potential. Bone marrow concentrate (BMC) could be an option how to promote allograft PLF healing. The purpose of the presented study was to investigate the validity of BMC addition to allografts in instrumented lumbar PLF surgery. Methods. The study was prospective, randomised, controlled and blinded. Eighty patients with degenerative disease of the lumbar spine underwent instrumented (S. 4. , Aesculap, Tuttlingen, Germany) lumbar or lumbosacral PLF. In forty cases, the PLF was done with spongious allograft chips alone (Group I). In another forty cases, spongious allograft chips were mixed with BMC (Group II), where the mesenchymal stem cell (MSCs) concentration was 1.74 × 10. 4. /L at average (range, 1.06–1.98 × 10. 4. /L). Patients were scheduled for anteroposterior and
Summary. Alignment results did not differ between PSG and conventional instrumentation. A small reduction in operation time and blood loss was found with the PSG system, but is unlikely of clinical significance. Length of hospital stay was identical for both groups. Introduction. Several techniques for aligning a TKA exist nowadays. Patient-specific guiding (PSG) has relatively recently been introduced to try to resolve the shortcomings of existing techniques while optimising the operative procedure. Still few reports have been published on the clinical outcome and on the peroperative results of this new technique. This prospective, double-blind, randomised controlled trial was designed to address the following research questions: 1. Is there a significant difference in outliers in alignment in the frontal and sagittal plane between PSG TKA and conventional TKA. 2. Is there a significant difference in operation time, blood loss and length of hospital stay between the 2 techniques. Patients & Methods. 180 patients were randomised for PSG TKA (group 1) or conventional TKA (group 2) in 2 centres. Patients were stratified per hospital. Alignment of the mechanical axis of the leg and flexion/extension and varus/valgus of the individual prosthesis components were measured on digital, standing, long-leg and standard
Summary Statement. We present a simple and useful geometrical equation system to carry out the pre-operative planning and intra-operative assessments for total knee arthroplasty. These methods are extremely helpful in severely deformed lower limbs. Introduction. Total knee arthroplasty is a highly successful surgery for most of the patients with knee osteoarthritis. With commercial instruments and jigs, most surgeons can correct the deformity and provided satisfactory results. However, in cases with severe extra-articular deformity, the instruments may mislead surgeons in making judgment of the true mechanical axis. We developed a geometrical equation system for pre-operative planning and intra-operative measurement to perform correct bony cuts and achieve good post-operative axis. Patients & Methods. From 2008 to 2012, twenty-four patients with severe extra-articular deformities of low limbs underwent total knee arthroplasties for osteoarthritis. The deformities included malunion of femoral or tibial shafts with angulation, non-union of femoral supracondylar fractures, failed high tibia osteotomies, severe bowing of femurs, and other post-traumatic sequelae. The intra-medullary or extra-medullary guide devices were not possible to provide correct axis in these cases. For pre-operative planning, we analyzed the deformities on triple-film scanography and standing anterior-posterior and
Summary. The dGEMRIC index correlates more strongly with the pattern of radiographic joint space narrowing in hip osteoarthritis at five year follow-up than morphological measurements of the proximal femur. It therefore offers potential to refine predictive models of hip osteoarthritis progression. Introduction. Longitudinal general population studies have shown that femoroacetabular impingement increases the risk of developing hip osteoarthritis, however, morphological parameters have a low positive predictive value. Arthroscopic debridement of impingement lesions has been proposed as a potential strategy for the prevention of osteoarthritis, however, the development of such strategies requires the identification of individuals at high risk of disease progression. We investigated whether delayed Gadolinium-Enhanced MRI of Cartilage (dGEMRIC) predicts disease progression. This imaging modality is an indirect measure of cartilage glycosaminoglycan content. Patients and Methods. 34 asymptomatic individuals from a longitudinal cohort study (sibkids) were assessed at baseline with the collection of Patient Reported Outcome Measures (PROMs), anteroposterior and cross-table
Summary. Quantification of Three-Dimensional Computed Tomography (Q3DCT) is a reliable and reproducible technique to quantify and characterise ankle fractures with a posterior malleolar fragment (. www.traumaplatform.org. ). This technique could be useful to characterise posterior malleolar fragments associated with specific ankle fracture patterns. Introduction. Fixation of posterior malleolar fractures of the ankle is subject of ongoing debate1. Fracture fixation is recommended for fragments involving 25–30% of articular surface1. However, these measurements -and this recommendation- are based on plain
Medial meniscus tear has been proposed as a potential etiology of spontaneous osteonecrosis of the knee (SONK). Disruption of collagen fibers within the meniscus causes meniscal extrusion, which results in alteration in load distribution in the knee. A recent study has demonstrated high incidence of medial meniscus extrusion in the knee with SONK. Our purpose was to determine whether the extent of medial meniscus extrusion correlates with the severity of SONK in the medial femoral condyle. Anteroposterior and
It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome. Methods. Retrospective study of primary THR patients at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and
Consequent upon a retrospective audit of all acute tibial nail patients within GRI in 2010, it was agreed, due to variable follow-up, imaging and requirement for secondary intervention, a standardised protocol for management of acutely nailed tibial fractures within GRI was to be established. Subsequently, a Nurse Led Tibial Nail Clinic commenced in July 201. The majority of consultants (11 of 13) devolving follow up of these patients to a protocol based algorithm designed on evidence based principles and consensus expert opinion. Aims were to standardise/improve management of tibial nail patients in terms of patient education, weight bearing, imaging, follow-up intervals and also coordinate secondary intervention via a single consultant with an interest in limb reconstruction/non union. A secondary goal was to achieve measureable outcome data for this subgroup of patients. All patients underwent post operative radiographs prior to discharge, review in clinic at 10 days for wound assessment, 6 weeks for physiotherapy and 12 weeks where standard AP and