Aims. To report mid- to long-term results of Oxford mobile bearing domed
Introduction:. Isolated lateral compartment osteoarthritis (OA) occurs in 5–10% of knees with unicompartmental OA.
Aims. It remains controversial whether patellofemoral joint pathology is a contraindication to
Objectives. Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain. Methods. A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system. Results. A 5° increase in tibial component posterior slope resulted in a 53% increase in mean major principal strain in the posterior tibial zone adjacent to the implant (p = 0.003). The highest strains for all implant positions were recorded in the anterior cortex 2 cm to 3 cm distal to the implant. Posteriorly, strain tended to decrease with increasing distance from the implant. Lateral cortical strain showed no significant relationship with implant position. Conclusion. Relatively small changes in implant position and orientation may significantly affect tibial cortical strain. Avoidance of excessive posterior tibial slope may be advisable during lateral UKA. Cite this article: A. M. Ali, S. D. S. Newman, P. A. Hooper, C. M. Davies, J. P. Cobb. The effect of implant position on bone strain following
Purpose. The aim of this study was to compare the short-term and mid-term outcome of lateral UKRs using a single prosthesis, the AMC Uniglide knee implant. Methods. Between 2003 and 2010, seventy
Oxford Medial Unicompartmental Knee Replacement (OMUKR) is a well-established treatment option for isolated medial compartment arthritis, with good patient reported outcome measures (PROMs). We present our results of the Oxford Domed
The December 2024 Knee Roundup. 360. looks at: Unicompartmental knee arthroplasty and total knee arthroplasty in the same patient?;
Introduction. Patient Specific Instrumentation (PSI) has the potential to allow surgeons to perform procedures more accurately, at lower cost and faster than conventional instrumentation. However, studies using PSI have failed to convincingly demonstrate any of these benefits clinically. The influence of guide design on the accuracy of placement of PSI has received no attention within the literature. Our experience has suggested that surgeons gain greater benefit from PSI when undertaking procedures they are less familiar with.
Abstract. Background. The Oxford Domed
Introduction: Unicompartmental knee Arthroplasty (UKA) is a commonly used and accepted treatment for Osteoarthritis (OA) in the medial compartment. How-ever, despite some good results. 1. there is still a reluctance to use this procedure in the lateral compartment for the same indications, as the procedure is considered technically difficult, and not as successful. 2. This study reports the clinical outcome of lateral UKAs in comparison with medial UKAs, TKAs and a normal population group using a knee score designed to highlight the shortcomings of TKA. 3. . Methods: 20 consecutive patients over 2 years following lateral UKA were functionally assessed. They were compared with 3 groups of 20 age and sex matched patients: those who had undergone medial UKA or TKA in the same time period, or normal controls from an upper limb clinic. Clinical function was assessed at least 2 years postoperatively, using the ‘total knee questionaire’. 3. This consists of 55 scaled multiple choice questions. The score is derived from the product of three scales: the importance of a specific activity, the frequency with which it is undertaken, and the ease with a patient can perform it. Results: 90% of the patients reported that they were either satisfied or very satisfied with their lateral UKA, with 95% of the patients in the medial UKA group and 75% in the TKA group reaching this level of satisfaction. The average Composite Score for the lateral UKA group was significantly better compared with the TKA group (p <
0, 05). (Kneeling – (5,72/4,45), Gardening – (7,32/5,18), Pivoting – (7,83/6,78) and Walking with heavy bags (8,2/5,97)). The Total Composite Score was significantly better (p<
0, 05) in Patients after lateral UKA (7,14) compared to patients who underwent TKA (5,99). No statistically significant differences in the Total Composite Score was found between both the lateral &
medial UKA patients taken as a single group compared with the control group. Conclusion:
Introduction. It is documented in the literature the very good results of
Introduction. Chronic uneven distribution of forces over the articular cartilage, which are present in OA, has been shown to be a risk factor for the development of OA. Certain regions of the articular cartilage will be exposed to increased chronic peak loads, whereas other regions encounter a corresponding relative reduction of transmitted forces. This has a well known influence on cartilage viability and is a precursor of degenerative progression. Congruence of joints has an important impact on force distribution across articular surfaces. Therefore, tibiofemoral incongruence could lead to alterations of load distribution and ultimately to progressive degenerative changes. In clinical practice the routine method for evaluation of progressive OA is analysis of joint space width (JSW) using weight bearing radiographs. Recent studies have suggested that JSW has a strong positive correlation with cartilage compression, volume and meniscal extrusion. Lateral unicondylar knee arthroplasty (UKA) has gained increasing popularity over the last decade in the treatment of isolated unicompartmental osteoarthritis (OA). However, progressive degenerative alterations of the medial compartment following
We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled prosthesis. At a mean follow-up of nine years (2 to 21) 15 knees had revision surgery, nine for progression of arthritis, six for loosening, four for breakage of a component and four for more than one reason. Six patients complained of moderate or severe pain at the final follow-up. Only five knees were lost to follow-up in the 21-year period. We performed survivorship analysis on the group using revision for any cause as the endpoint. At ten years the cumulative survival rate was 83%, and at 15 years, when ten knees were still at risk, it was 74%. Based on our clinical results and survival rate the St Georg Sled may be considered to be a suitable unicompartmental replacement for isolated lateral compartment osteoarthritis.
The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from distal femur nor to over tighten the knee and thus ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component. The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III].Introduction
Aim
The results of mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing (five-year survival: 82%). Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to a high dislocation rate. A detailed analysis confirmed the elevated lateral tibial joint line to be a contributory factor to bearing dislocation. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from the distal femur nor to over tighten the knee and therefore ensure that the tibial joint line was not elevated. Other modifications included use of a domed tibial component. The aim of this study is to compare the outcome of these iterations: the original series (series I), those with improved surgical technique (series II) and the domed tibial component (series III). The primary outcome measure was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In the original series (n=53), implanted using a standard open approach, there were six dislocations in the first year, the average flexion 110°, and 95% had no/mild pain on activity. In the second series (n=65), there were 3 dislocations, the average flexion was 117°, and 80% had no/mild pain on activity. In the third series with the modified technique and a convex domed tibial plateau, there was one dislocation, average flexion was 125° and 94% had no/mild pain on activity. At four years the cumulative primary dislocation rates were 10%, 5% and 0% respectively, and were significantly different (p=0.04). The improved surgical technique and implant design has reduced dislocation rate to an acceptable level so a mobile bearing can now be recommended for lateral UKR.
Commonly performed unicompartmental knee arthroplasty (UKA) is not designed for the lateral compartment. Additionally, the anatomical medial and lateral tibial plateaus have asymmetrical geometries, with a slightly dished medial plateau and a convex lateral plateau. Therefore, this study aims to investigate the native knee kinematics with respect to the tibial insert design corresponding to the lateral femoral component. Subject-specific finite element models were developed with tibiofemoral (TF) and patellofemoral joints for one female and four male subjects. Three different TF conformity designs were applied. Flat, convex, and conforming tibial insert designs were applied to the identical femoral component. A deep knee bend was considered as the loading condition, and the kinematic preservation in the native knee was investigated.Aims
Methods
Mobile-bearing unicompartmental knee replacements
(UKRs) with a flat tibial plateau have not performed well in the
lateral compartment, owing to a high dislocation rate. This led
to the development of the Domed Lateral Oxford UKR (Domed OUKR)
with a biconcave bearing. The aim of this study was to assess the
survival and clinical outcomes of the Domed OUKR in a large patient
cohort in the medium term. We prospectively evaluated 265 consecutive knees with isolated
disease of the lateral compartment and a mean age at surgery of
64 years (32 to 90). At a mean follow-up of four years ( The Domed Lateral OUKR gives good clinical outcomes, low re-operation
and revision rates and a low dislocation rate in patients with isolated
lateral compartmental disease, in the hands of the designer surgeons. Cite this article:
There has been renewed interest in the use of unicompartmental knee arthroplasty (UKA) for patients with limited degenerative disease of the knee due to improved surgical techniques and prosthetic design, and the desire for minimally invasive surgery. However, patient satisfaction following UKA for lateral compartment disease have been suboptimal with increased revision rates. Robotic-assisted UKA has been shown to improve precision and accuracy of component placement, which may improve outcomes of lateral UKA. The purpose of this study was to compare the outcome of robotic-assisted UKA to conventional UKA for degenerative disease of the lateral compartment with the hypothesis that robotic-assisted lateral UKA results in superior outcomes compared to conventional UKA. The institution's joint registry was searched for patients who underwent UKA for limited degenerative disease of the lateral knee compartment between 2004 and 2012 and a total of 125 lateral UKAs were identified. The medical records of all patients were reviewed and assessed for the type of surgical procedure used (robotic-assisted versus conventional), length of hospital stay, Oxford knee score, and occurrence of revision surgery. Preoperative and postoperative radiographs were assessed for tibiofemoral angle, femoral and tibial joint line angle, posterior tibial slope, and orientation of the femoral and tibial components.Introduction
Methods
Between 29th May 2001 and 15th May 2003, 233 consecutive Preservation unicompartmental knee replacements (UKR) were performed. Of these, 30 were lateral UKRs (13%) performed in 12 men and 16 women (2 bilateral cases) with a mean age of 67 years (range 36 to 93 years). A metal-backed mobile bearing tibial component was used in 13 knees and an all-polyethylene fixed bearing tibial component in 17 knees. The patients were reviewed prospectively at 1 and 2 years. The 2 year results show no difference in range of motion or function between the mobile and fixed bearing versions of the Preservation knee when used on the lateral side. This is similar to the reported results on the medial side. There were 3 early revisions, all in the mobile bearing group. The incidence of revision has been reduced by the introduction of an improved cementing technique.