Advertisement for orthosearch.org.uk
Results 1 - 20 of 148
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 1 - 1
4 Apr 2023
Buldu M Sacchetti F Yasen A Furtado S Parisi V Gerrand C
Full Access

Primary malignant bone and soft tissue tumours often occur in the lower extremities of active individuals including children, teenagers and young adults. Survivors routinely face long-term physical disability. Participation in sports is particularly important for active young people but the impact of sarcoma treatment is not widely recognised and clinicians may be unable to provide objective advice about returning to sports. We aimed to identify and summarise the current evidence for involvement in sports following treatment of lower limb primary malignant bone and soft tissue tumours. A comprehensive search strategy was used to identify relevant studies combining the main concepts of interest: (1) Bone/Soft Tissue Tumour, (2) Lower Limb, (3) Surgical Interventions and (4) Sports. Studies were selected according to eligibility criteria with the consensus of three authors. Customised data extraction and quality assessment tools were used. 22 studies were selected, published between 1985 – 2020, and comprising 1005 patients. Fifteen studies with data on return to sports including 705 participants of which 412 (58.4%) returned to some form of sport at a mean follow-up period of 7.6 years. Four studies directly compared limb sparing and amputation; none of these were able to identify a difference in sports participation or ability. Return to sports is important for patients treated for musculoskeletal tumours, however, there is insufficient published research to provide good information and support for patients. Future prospective studies are needed to collect better pre and post-treatment data at multiple time intervals and validated clinical and patient sports participation outcomes such as type of sports participation, level and frequency and a validated sports specific outcome score, such as UCLA assessment. In particular, more comparison between limb sparing and amputation would be welcome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 103 - 103
4 Apr 2023
Lu V Zhou A Krkovic M
Full Access

A major cause of morbidity in lower limb amputees is phantom limb pain (PLP) and residual limb pain (RLP). This study aimed to determine if surgical interposition of nerve endings into adjacent muscle bellies at the time of major lower limb amputation can decrease the incidence and severity of PLP and RLP. Data was retrospectively collected from January 2015 to January 2021, including eight patients that underwent nerve interposition (NI) and 36 that received standard treatment. Primary outcomes included the 11-point Numerical Rating Scale (NRS) for pain severity, and Patient-Reported Outcomes Measurement Information System (PROMIS) pain intensity, behaviour, and interference. Secondary outcome included Neuro-QoL Lower Extremity Function assessing mobility. Cumulative scores were transformed to standardised t scores. Across all primary and secondary outcomes, NI patients had lower PLP and RLP. Mean ‘worst pain’ score was 3.5 out of 10 for PLP in the NI cohort, compared to 4.89 in the control cohort (p=0.298), and 2.6 out of 10 for RLP in the NI cohort, compared to 4.44 in the control cohort (p=0.035). Mean ‘best pain’ and ‘current pain’ scores were also superior in the NI cohort for PLP (p=0.003, p=0.022), and RLP (p=0.018, p=0.134). Mean PROMIS t scores were lower for the NI cohort for RLP (40.1 vs 49.4 for pain intensity; p=0.014, 44.4 vs 48.2 for pain interference; p=0.085, 42.5 vs 49.9 for pain behaviour; p=0.025). Mean PROMIS t scores were also lower for the NI cohort for PLP (42.5 vs 52.7 for pain intensity; p=0.018); 45.0 vs 51.5 for pain interference; p=0.015, 46.3 vs 51.1 for pain behaviour; p=0.569). Mean Neuro-QoL t score was lower in NI cohort (45.4 vs 41.9;p=0.03). Surgical interposition of nerve endings during lower limb amputation is a simple yet effective way of minimising PLP and RLP, improving patients’ subsequent quality of life. Additional comparisons with targeted muscle reinnervation should be performed to determine the optimal treatment option


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 82 - 82
2 Jan 2024
Özer Y Karaduman D Karanfil Y Çiftçi E Balci C Doğu B Halil M Cankurtaran M Korkusuz F
Full Access

Osteoarthritis (OA) of the knee joint is a complex peripheral joint disorder with multiple risk factors. We aimed to examine the relationship between the grade of knee OA and anterior thigh length (ATL). A total of 64 geriatric patients who had no total hip or knee replacement with a BMI of ≥30 were evaluated. Patients' OA severity was determined by two independent experts from bilateral standing knee radiographs according to the Kellgren-Lawrence (KL) grade. Joint cartilage structure was assessed using ultrasonography (US). The ATL, the gastrocnemius medialis (GC), the rectus femoris (RF) and the rectus abdominis (RA) skeletal muscle thicknesses as well as the RF cross-sectional area (CSA) were measured with US. Sarcopenia was diagnosed using the handgrip strength (HGS), 5× sit-to-stand test (5xSST) and bioelectrical impedance analysis. The median (IQR) age of participants was 72 (65–88) years. Seventy-one per cent of the patients (n=46) were female. They were divided into the sarcopenic obese (31.3 %) and the non-sarcopenic obese (68.8%) groups. KL grade of all patients correlated negatively with the ATL (mm) and the thickness of GC (mm) (r= -0,517, p<0.001 and r= -0.456, p<0.001, respectively). In the sarcopenic obese and the non-sarcopenic obese groups, KL grade of the all patients was negatively correlated with ATL (mm) and thickness of GC (mm) (r= -0,986, p<0.001; r= -0.456, p=0.05 and r= -0,812, p=0.002; r= −0,427, p=0.006). KL grade negatively correlated with the RF thickness in the sarcopenic obese group (r= -0,928, p=0.008). In conclusion, OA risk may decrease as the lower extremity skeletal muscle mass increases. Acknowledgments: Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 19 - 19
1 Dec 2022
Belvedere C Ruggeri M Berti L Ortolani M Durante S Miceli M Leardini A
Full Access

Biomedical imaging is essential in the diagnosis of musculoskeletal pathologies and postoperative evaluations. In this context, Cone-Beam technology-based Computed Tomography (CBCT) can make important contributions in orthopaedics. CBCT relies on divergent cone X-rays on the whole field of view and a rotating source-detector element to generate three-dimensional (3D) volumes. For the lower limb, they can allow acquisitions under real loading conditions, taking the name Weight-Bearing CBCT (WB-CBCT). Assessments at the foot, ankle, knee, and at the upper limb, can benefit from it in situations where loading is critical to understanding the interactions between anatomical structures. The present study reports 4 recent applications using WB-CBCT in an orthopaedic centre. Patient scans by WB-CBCT were collected for examinations of the lower limb in monopodal standing position. An initial volumetric reconstruction is obtained, and the DICOM file is segmented to obtain 3D bone models. A reference frame is then established on each bone model by virtual landmark palpation or principal component analysis. Based on the variance of the model point cloud, this analysis automatically calculates longitudinal, vertical and mid-lateral axes. Using the defined references, absolute or relative orientations of the bones can be calculated in 3D. In 19 diabetic patients, 3D reconstructed bone models of the foot under load were combined with plantar pressure measurement. Significant correlations were found between bone orientations, heights above the ground, and pressure values, revealing anatomic areas potentially prone to ulceration. In 4 patients enrolled for total ankle arthroplasty, preoperative 3D reconstructions were used for prosthetic design customization, allowing prosthesis-bone mismatch to be minimized. 20 knees with femoral ligament reconstruction were acquired with WB-CBCT and standard CT (in unloading). Bone reconstructions were used to assess congruency angle and patellar tilt and TT-TG. The values obtained show differences between loading and unloading, questioning what has been observed so far. Twenty flat feet were scanned before and after Grice surgery. WB-CBCT allowed characterization of the deformity and bone realignment after surgery, demonstrating the complexity and multi-planarity of the pathology. These applications show how a more complete and realistic 3D geometric characterization of the of lower limb bones is now possible in loading using WB-CBCT. This allows for more accurate diagnoses, surgical planning, and postoperative evaluations, even by automatisms. Other applications are in progress


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 91 - 91
1 Jan 2017
Shi J Browne M Barrett D Heller M
Full Access

Inter-subject variability is inherently present in patient anatomy and is apparent in differences in shape, size and relative alignment of the bony structures. Understanding the variability in patient anatomy is useful for distinguishing between pathologies and to assist in surgical planning. With the aim of supporting the development of stratified orthopaedic interventions, this work introduces an Articulated Statistical Shape Model (ASSM) of the lower limb. The model captures inter-subject variability and allows reconstructing ‘virtual’ knee joints of the lower limb shape while considering pose. A training dataset consisting of 173 lower limbs from CT scans of 110 subjects (77 male, 33 female) was used to construct the ASSM of the lower limb. Each bone of the lower limb was segmented using ScanIP (Simpleware Ltd., UK), reconstructed into 3D surface meshes, and a SSM of each bone was created. A series of sizing and positioning procedures were carried out to ensure all the lower limbs were in full extension, had the same femoral length and that the femora were aligned with a coincident centre. All articulated lower limbs were represented as: (femur scale factor) × (full extension articulated lower limb + relative transformation of tibia, fibula and patella to femur). Articulated lower limbs were in full extension were used to construct a statistical shape model, representing the variance of lower limb morphology. Relative transformations of the tibia, fibula and patella versus the femur were used to form a statistical pose model. Principal component analysis (PCA) was used to extract the modes of changes in the model. The first 30 modes of the shape model covered 90% of the variance in shape and the first 10 modes of the pose model covered 90% of the pose variance. The first mode captures changes of the femoral CCD angle and the varus/valgus alignment of the knee. The second mode represents the changes in the ratio of femur to tibia length. The third mode reflects change of femoral shaft diameter and patella size. The first mode characterising pose captures the medial/lateral translation between femur and tibia. The second mode represents variation in knee flexion. The third mode reflects variation in tibio-femoral joint space. An articulated statistical modelling approach was developed to characterize inter-subject variability in lower limb morphology for a set of training specimens. This model can generate large sets of lower limbs to systematically study the effect of anatomical variability on joint replacement performance. Moreover, if a series of images of the lower limb during a dynamic activity are used as training data, this method can be applied to analyse variance of lower limb motion across a population


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 30 - 30
1 Mar 2021
De Vecchis M Biggs PR Wilson C Whatling GM Holt CA
Full Access

Abstract. Objectives. Exploring the association of objective lower limb function pre and post total knee replacement (TKR). Methods. 3D gait analysis was performed on 28 non-pathological participants (NP) and 40 patients with advanced knee osteoarthritis (OA) before and approximately one year after TKR. For NP and OA patients pre/post-TKR, 12 waveforms on kinetic and kinematic variables of the operative side were chosen to perform data reduction through Principal Component (PC) Analysis. The Cardiff Classifier, a classification system based on Dempster-Shafer theory, was trained with the first 3 PCs of each variable. The 18 highest-ranking PCs classifying the biomechanical features of each participant as Belief in Healthy, Belief in OA (BOA) or Belief in Uncertainty were used to quantify biomechanical changes pre- to post-TKR. The correlation between patients’ BOA values (range: 0 to 1, 0 indicates null BOA and 1 high BOA) pre- and post-TKR was tested through Spearman's correlation coefficient. Wilcoxon matched-pair test (α<0.05) determined the significance of the change in BOA. Results. NP (57% women) had a mean age of 38 (SD=18.13), mean height and weight of 1.70 m (SD=0.09) and 68 Kg (SD=15.24), respectively. Their mean BOA was 0.05 (SD=0.08), in line with inclusion criteria. OA patients (38% women) had a mean age of 68.5 (SD=7.59), mean height and weight of 1.68 m (SD=0.10) and 92.6 Kg (SD=21.22), respectively. Their mean pre-TKR BOA was 0.81 (SD=0.18), falling to 0.64 (SD=0.26) post-TKR. The change in BOA (0.16, SD=0.19) pre- to post-TKR was significant (p=0.000). BOAs pre- and post-TKR were non-normally distributed therefore, a Spearman's rank-order correlation was run, revealing a positive, statistically significant (p=0.000), strong correlation (r. S. =0.657) between BOA pre- and post-TKR. Conclusions. This study found that worse objective pre-operative lower limb function in people with advanced knee OA was strongly correlated with poorer one-year post-TKR function (r. S. =0.657, p<0.01). Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 57 - 57
1 Mar 2021
Walker R Rye D Yoong A Waterson B Phillips J Toms A
Full Access

Abstract. Background. Lower limb mechanical axis has long been seen as a key to successful in lower limb surgery, including knee arthroplasty. Traditionally, coronal alignment has been assessed with weight-bearing lower limb radiographs (LLR) allowing assessment of hip-knee-ankle alignment. More recently CT scanograms (CTS) have been advocated as a possible alternative, having the potential benefits of being quicker, cheaper, requiring less specialist equipment and being non-weightbearing. Objectives. To evaluate the accuracy and comparability of lower limb alignment values derived from LLR versus CTS. Methods. We prospectively investigated patients undergoing knee arthroplasty with preoperative and postoperative LLR and CTS, analysing both preoperative and postoperative LLRs & CTS giving 140 imaging tests for direct comparison. We used two independent observers to calculate on each of imaging modalities, on both pre- and post-operative images, the: hip-knee-ankle alignment (HKA), lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA). Results. 840 data points were captured from pre- and post-operative LLRs and CTSs. Analysis demonstrated very strong correlation in pre-operative HKA (LLR vs CTS, r = 0.917), post-operative HKAs (LLR vs CTS, 0.850) and postoperative LDFAs (LLR vs CTS, 0.850). Strong correlation was observed in pre-operative LDFAs (0.732), MPTAs (0.604), and post-operative MPTAs (0.690). Conclusion. Both pre- and post-operative LLR and CTS imaging display very strong correlation for HKA coronal alignment correlation, with strong correlation for other associated angles around the knee. Our results demonstrate that both LLR and CTS can be used interchangeably with similar results. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 19 - 19
1 Nov 2021
Ghaffari A J⊘rgensen M R⊘mer H S⊘ensen M Kold S Rahbek O Bisgaard J
Full Access

Introduction and Objective. Continuous peripheral nerve blocks (cPNBs) have shown good results in pain management after orthopedic surgeries. However, the variation of performance between different subspecialities is unknown. The aim of this study is to describe our experience with cPNBs after lower limb orthopedic surgeries in different subspecialties. Materials and Methods. This prospective cohort study was performed on collected data from cPNBs after orthopedic surgeries in lower limbs. Catheters were placed by experienced anesthesiologists using sterile technique. After catheterization, the patients were examined daily, by specially educated acute pain service nurses. The characteristics of the patients, duration of catheterization, severity of the post-operative pain, need for additional opioids, and possible complications were registered. Results. We included 246 patients (=547 catheters). 115 (21%) femoral, 162 (30%) saphenous, 66 (12%) sciatic, and 204 (37%) popliteal sciatic nerve catheter were used. The median duration of a catheter was 3 days [IQR = 2 – 5]. The proportion of femoral, sciatic, saphenous, and popliteal nerve catheters with duration of more than two days was 81%, 79%, 73%, and 71% for, respectively. This proportion varied also between different subspecialties. 91% of the catheters remained in place for more than two days in amputations (n=56), 89% in pediatric surgery (n=79), 76% in trauma (n=217), 64% in foot and ankle surgery (n=129), and 59% in limb reconstructive surgery (n=66). The proportion of pain-free patients were 77 – 95% at rest, 63 – 88% at mobilization. 79 – 92% did not need increased opioid doses, and 50 – 67% did not require PRN opioid. 443 catheters (81%) were removed as planned. The cause of unplanned catheter removal was loss of efficacy in 69 (13%), dislodgement in 23 (4.2%), leakage in 8 (1.5%), and erythema in 4 catheters (0.73%). No major complication occurred. Conclusions. 81% of catheters remained in place until planned removal and opioid usage after surgery was lower than expected. Catheters were efficient in both adult and pediatric surgery; however, a variation was seen between orthopaedic subspecialities regarding duration of nerve catheter usage


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 50 - 50
14 Nov 2024
Birkholtz F Eken M Swanevelder M Engelbrecht A
Full Access

Introduction. Inaccurate identification of implants on X-rays may lead to prolonged surgical duration as well as increased complexity and costs during implant removal. Deep learning models may help to address this problem, although they typically require large datasets to effectively train models in detecting and classifying objects, e.g. implants. This can limit applicability for instances when only smaller datasets are available. Transfer learning can be used to overcome this limitation by leveraging large, publicly available datasets to pre-train detection and classification models. The aim of this study was to assess the effectiveness of deep learning models in implant localisation and classification on a lower limb X-ray dataset. Method. Firstly, detection models were evaluated on their ability to localise four categories of implants, e.g. plates, screws, pins, and intramedullary nails. Detection models (Faster R-CNN, YOLOv5, EfficientDet) were pre-trained on the large, freely available COCO dataset (330000 images). Secondly, classification models (DenseNet121, Inception V3, ResNet18, ResNet101) were evaluated on their ability to classify five types of intramedullary nails. Localisation and classification accuracy were evaluated on a smaller image dataset (204 images). Result. The YOLOv5s model showed the best capacity to detect and distinguish between different types of implants (accuracy: plate=82.1%, screw=72.3%, intramedullary nail=86.9%, pin=79.9%). Screw implants were the most difficult implant to detect, likely due to overlapping screw implants visible in the image dataset. The DenseNet121 classification model showed the best performance in classifying different types of intramedullary nails (accuracy=73.7%). Therefore, a deep learning model pipeline with the YOLOv5s and DenseNet121 was proposed for the most optimal performance of automating implants localisation and classification for a relatively small dataset. Conclusion. These findings support the potential of deep learning techniques in enhancing implant detection accuracy. With further development, AI-based implant identification may benefit patients, surgeons and hospitals through improved surgical planning and efficient use of theatre time


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1019 - 1023
1 Nov 1997
Strecker W Keppler P Gebhard F Kinzl L

Corrective osteotomies are often planned and performed on the basis of normal anatomical proportions. We have evaluated the length and torsion of the segments of the lower limb in normal individuals, to analyse the differences between left and right sides, and to provide tolerance figures for both length and torsion. We used CT on 355 adult patients and measured length and torsion by the Ulm method. We excluded all patients with evidence of trauma, infection, tumour or any congenital disorder. The mean length of 511 femora was 46.3 ± 6.4 cm (±2. sd. ) and of 513 tibiae 36.9 ± 5.6 cm; the mean total length of 378 lower limbs was 83.2 ± 11.4 cm with a tibiofemoral ratio of 1 to 1.26 ± 0.1. The 99th percentile level for length difference in 178 paired femora was 1.2 cm, in 171 paired tibiae 1.0 cm and in 60 paired lower limbs 1.4 cm. In 505 femora the mean internal torsion was 24.1 ± 17.4°, and in 504 tibiae the mean external torsion was 34.9 ± 15.9°. For 352 lower limbs the mean external torsion was 9.8 ± 11.4°. The mean torsion angle of right and left femora in individuals did not differ significantly, but mean tibial torsion showed a significant difference between right (36.46° of external torsion) and left sides (33.07° of external torsion). For the whole legs torsion on the left was 7.5 ± 18.2° and 11.8 ± 18.8°, respectively (p < 0.001). There was a trend to greater internal torsion in femora in association with an increased external torsion in tibiae, but we found no correlation. The 99th percentile value for the difference in 172 paired femora was 13°; in 176 pairs of tibiae it was 14.3° and for 60 paired lower limbs 15.6°. These results will help to plan corrective osteotomies in the lower limbs, and we have re-evaluated the mathematical limits of differences in length and torsion


Bone & Joint Research
Vol. 2, Issue 9 | Pages 179 - 185
1 Sep 2013
Warwick DJ Shaikh A Gadola S Stokes M Worsley P Bain D Tucker AT Gadola SD

Objectives. We aimed to examine the characteristics of deep venous flow in the leg in a cast and the effects of a wearable neuromuscular stimulator (geko; FirstKind Ltd) and also to explore the participants’ tolerance of the stimulator. Methods. This is an open-label physiological study on ten healthy volunteers. Duplex ultrasonography of the superficial femoral vein measured normal flow and cross-sectional area in the standing and supine positions (with the lower limb initially horizontal and then elevated). Flow measurements were repeated during activation of the geko stimulator placed over the peroneal nerve. The process was repeated after the application of a below-knee cast. Participants evaluated discomfort using a questionnaire (verbal rating score) and a scoring index (visual analogue scale). Results. The geko device was effective in significantly increasing venous blood flow in the lower limb both with a plaster cast (mean difference 11.5 cm/sec. -1. ; p = 0.001 to 0.13) and without a plaster cast (mean difference 7.7 cm/sec. -1. ; p = 0.001 to 0.75). Posture also had a significant effect on peak venous blood flow when the cast was on and the geko inactive (p = 0.003 to 0.69), although these differences were less pronounced than the effect of the geko (mean difference 3.1 cm/sec. -1. (-6.5 to 10)). The geko device was well tolerated, with participants generally reporting only mild discomfort using the device. Conclusion. The geko device increases venous blood flow in the lower limb, offering a potential mechanical thromboprolylaxis for patients in a cast. Cite this article: Bone Joint Res 2013;2:179–85


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 71 - 71
11 Apr 2023
Pelegrinelli A Kowalski E Ryan N Dervin G Moura F Lamontagne M
Full Access

The study compared thigh-shank and shank-foot coordination during gait before and after total knee arthroplasty (TKA) with controls (CTRL).

Twenty-seven patients (male=15/female=12; age=63.2±6.9 years) were evaluated one month prior to and twelve months after surgery, and compared to 27 controls (male=14/female=13; age=62.2±4.3). The participants were outfitted with a full-body marker set. Gait speed (normalized by leg length) was calculated. The time series of the thigh, shank, and foot orientation in relation to the laboratory coordinate system were extracted. The coordination between the thigh-shank and shank-foot in the sagittal plane were calculated using a vector coding technique. The coupling angles were categorized into four coordination patterns. The stance phase was divided into thirds: early, mid, and late stance. The frequency of each pattern and gait speed were compared using a one-way ANOVA with a post-hoc Bonferroni correction.

Walking speed and shank-foot coordination showed no differences between the groups. The thigh-shank showed differences. The pre-TKA group showed a more in-phase pattern compared to the CTRL group during early-stance. During mid-stance, the pre- and post-TKA presented a more in-phase pattern compared to the CTRL group. Regarding shank-foot coordination, the groups presented an in-phase and shank pattern, with more shank phase during mid-stance and more in-phase during late-stance.

The pre-TKA group showed greater differences than the post-TKA compared to the controls. The more in-phase pattern in the pre- and post-TKA groups could relate to a reduced capacity for the thigh that leads the movement. During mid-stance in normal gait, the knee is extending, where the thigh and shank movements are in opposite directions. The in-phase results in the TKA groups indicate knee stiffness during the stance phase, which may relate to a muscular deficit or a gait strategy to reduce joint stress.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 32 - 32
1 Jan 2017
Hong S Wang T Lu T Kuo C Hsu H
Full Access

Identification of gait deviations and compensations in patients with total hip arthroplasty (THA) is important for the management of their fall risks. To prevent collapse of the lower limbs while balancing and supporting the body, proper combinations of joint moments are necessary. However, hip muscles affected by THA may compromise the sharing of load and thus the whole body balance. The current study aimed to quantify the control of body support in patients with THA in terms of the total support moment (Ms) and contributions of individual joint moments to Ms during walking. Six patients who underwent unilateral THA via an anterolateral approach for at least six months at the time of the gait experiment, and six age- and gender-matched healthy controls were recruited. Twenty-eight infrared retro-reflected markers were placed on specific landmarks of the pelvis-leg apparatus to track the motion of the segments during walking. Kinematic and kinetic data were measured using an 8-camera motion analysis system (Vicon, Oxford Metrics, U.K.) and two force plates (AMTI, U.S.A.). The Ms of a limb was calculated as the sum of the net extensor moments at the hip, knee and ankle during stance phase. The contributions of the hip, knee and ankle to the first and second peaks of Ms (Ms1 and Ms2) were calculated by dividing the joint moment value by the corresponding peak values of Ms. Independent t-tests were performed to compare between groups at a significance level set at α=0.05 using SAS version 9.2 (SAS Institute Inc., NC, USA). No significant differences in Ms1 and Ms2 were found between the THA group and normal controls (P >0.05). However, compared to the healthy controls, significantly increased hip and ankle contributions but decreased knee contributions to Ms1, and significantly increased hip contributions but decreased ankle contributions to Ms2 were found in the THA group. Similar Ms1 and Ms2 between groups indicates that the lower limbs in the THA group were able to provide normal body supports. However, this was achieved via an altered contributions of the hip, knee and ankle. Hip and knee extensors play important roles in supporting the body when the Ms1 occurs during early stance of walking. In the THA group, greater hip and ankle contributions but lesser knee contributions for the Ms1 indicates that the function of hip extensors were not affected but compensatory mechanisms of the knee and ankle were found. For the Ms2, hip flexor and ankle plantarflexors are important for supporting the body during late stance. Decreased hip flexor (i.e., greater hip extensor contributions) and ankle plantarflexor moments in the THA patients suggests that the hip flexors and ankle plantarflexor muscles were affected by THA surgery. Hip muscles affected by the THA may compromise the sharing of load at the hip and thus the whole body balance. Further postoperative rehabilitation is suggested for the patients following THA. Further studies on the effects of different surgical approaches on the support moments is needed for improving treatment plans


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 16 - 16
17 Apr 2023
Hornestam J Miller B Carsen S Benoit D
Full Access

To investigate differences in the drop vertical jump height in female adolescents with an ACL injury and healthy controls and the contribution of each limb in this task. Forty female adolescents with an ACL injury (ACLi, 15.2 ± 1.4 yrs, 164.6 ± 6.0 cm, 63.1 ± 10.0 kg) and thirty-nine uninjured (CON, 13.2 ± 1.7 yrs, 161.7 ± 8.0 cm, 50.6 ± 11.0 kg) were included in this study. A 10-camera infrared motion analysis system (Vicon, Nexus, Oxford, UK) tracked pelvis, thigh, shank, and foot kinematics at 200Hz, while the participants performed 3 trials of double-legged drop vertical jumps (DVJ) on two force plates (Bertec Corp., Columbus, USA) sampled at 2000Hz.The maximum jump height normalised by dominant leg length was compared between groups using independent samples t-test. The maximum vertical ground reaction force (GRFz) and sagittal ankle, knee and hip velocities before take-off were compared between limbs in both groups, using paired samples t-test. The normalised jump height was 11% lower in the ACLi than in the CON (MD=0.04 cm, p=0.020). In the ACLi, the maximum GRFz (MD=46.17N) and the maximum velocities of ankle plantar flexion (MD=79.83°/s), knee extension (MD=85.80°/s), and hip extension (MD=36.08°/s) were greater in the non-injured limb, compared to the injured limb. No differences between limbs were found in the CON.

ACL injured female adolescents jump lower than the healthy controls and have greater contribution of their non-injured limb, compared to their injured limb, in the DVJ task. Clinicians should investigate differences in the contribution between limbs during double-legged drop vertical jump when assessing patients with an ACL injury, as this could help identify asymmetries, and potentially improve treatment, criteria used to clear athletes to sport, and re-injury prevention.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 20 - 20
1 Jan 2017
Mohammad H Pillai A
Full Access

We describe a case series using calcium sulphate bio composite with antibiotics (Cerament/Stimulan) in treating infected metalwork in the lower limb. Eight patients aged 22–74 (7 males, 1 female) presented with clinical evidence of infected limb metal work from previous orthopaedic surgery. Metal work removal with application of either cerement in 5 cases (10–20ml including 175mg–350mg gentamycin) or stimulan in 3 cases (10–20ml including either 1g vancomycin or clindamycin 1.2g or 100mg tigecycline) into the site was performed. Supplemental systemic antibiotic therapy (oral/intravenous) was instituted based on intraoperative tissue culture and sensitivity. Four patients had infected ankle metalwork, 2 patients infected distal tibial metalwork and 2 had infected external fixators. Metal work was removed in all cases. The mean pre operative CRP was 15.8mg/l (range 1–56mg/l). The mean postoperative CRP at 1 month was 20.5mg/l (range 2–98mg/l). The mean pre op WCC was 7.9×10. 9. (range 4.7–10.5 ×10. 9. ). Mean post op WCC at 1 month was 7.1×10. 9. (range 5.0–9.2×10. 9. ). The organisms cultured included enterobacter, staphylococcus aureus, staphylococcus epidermidis, staphylococcus cohnii, stenotrophomonas, acinetobacter, group B streptococcus, enterococcus and escherichia coli. No additional procedures were required in any case. All surgical wounds went on to heal uneventfully. Infection control and union was achieved both clinically and radiologically in all cases. Our results support the use of a calcium sulphate bio composite with antibiotic as an adjuvant for effective local infection control in cases with implant related bone sepsis. The technique is well tolerated with no systemic or local side effects. We believe that implant removal, debridement and local antibiotic delivery can minimise the need for prolonged systemic antibiotic therapy in such cases


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2017
Stefanou M Pasparakis D Darras N Papagelopoulos P
Full Access

Many studies describe the use of the Ilizarov ring fixator for lower limb lengthening and for the management of the 3-dimensional lower limb deformities in achondroplasia, and most confirm the efficacy of this technique. However, long term follow up of these achondroplastic patients is lacking. Most studies have focused on magnitude of lengthening, treatment time required and complications, but no study has analyzed the long term postoperative condition of these patients using an objective, functional method such as gait analysis. Nineteen (19) achondroplastic patients, 12 males and 7 females, aged 19–38 years (mean 27.3 y) who have undergone tibia and femur lengthening, using the Ilizarov method, at the age of 9–19 years (mean 12.6 y), were evaluated 5–19 years (mean 10.1 y) after their last surgery, using 3-dimensional gait analysis. Nineteen (19) normal, height-matched subjects were used as controls. The VICON Nexus 8 Camera System was used to accurately measure spatiotemporal characteristics (walking velocity, stride length, step length, cadence) and kinematics (range of motion) of lower limb joints. Statistical comparison of deformity parameters between achondroplastic patients and normal population was done using the student t- test. A level of p<0.05 was considered statistically significant. Walking velocity, step length and stride length were statistically significantly decreased (p<0.05) in achondroplastic patients compared to normal population values. The achondroplastic group presented with excessive anterior pelvic tilt (mean 21.9. o. ± 7.3), excessive pelvic rotation (range 28.7. o. ±7.8), decreased hip extension (mean 1.8. o. ±10.1) and decreased plantar flexion (mean 17.1. o. ±5.1) when compared to normal controls. There was no statistically significant difference in the knee kinematics between the operated achondroplastic patients and normal controls. The achondroplastic patients present decreased values in their spatiotemporal characteristics compared to the normal subjects because, despite the height gain, their lower limbs remain shorter. Their excessive anterior pelvic tilt is attributed to their lordosis. Their excessive forward pelvic rotation is an attempt to increase stride and step length. The decreased hip extension is due to their anterior pelvic tilt. The correction of these patients genu varum restored knee kinematics to normal. In order to address the hip and pelvis deformities a proximal femoral osteotomy should be considered. The Ilizarov method provides functional height gain and substantially corrects the three-dimensional lower limb deformities of achondroplastic patients especially around the knee joint but more planning needs to be implemented when the system is applied to correct the disease specific deformities of the hip and pelvis. Gait analysis is an objective tool that can be used to address these design issues


Full Access

Summary. Cognitive testing scores do not correlate with physical braking performance. Psychological questioning shows patients are more dependent on driving than a control group. Introduction. Returning to driving after surgery is a multifaceted issue. There are the medical aspects to consider- whether the patient is medically fit to drive. The term ‘medically fit to drive’ can encompass a range of issues which fall to doctors to solve, including the psychological and mental wellbeing. Groups whose governance involves patients or driving do not issue sound advice for patients or doctors to follow. Investigation of aspects affecting a driver's ability to control their vehicle in a safe manner could go towards providing an evidence base for guidance to be issued in the future. Methods. A custom force assessment rig was used to gather peak force and reaction time measurements from a group of patients waiting for, or having undergone lower limb surgery. A bespoke questionnaire that investigated patient's attitudes towards returning to driving; their behaviours and concerns was issued. Other mobility questions were also issued to these patients, including the lower extremity functional scale (LEFS). The final tests (Stroop task, tower of Hanoi, and the opposite worlds test [OWT]) were aimed at assessing a patient's neurological function, in an attempt to investigate the effect of post-operative cognitive dysfunction (POCD) on driving ability. These data were compared against a control cohort. Results. No significant differences were observed in the physical results between cohorts. However, significant differences between the control cohort and patient cohort were observed in a number of tests. The tower of Hanoi was the only significantly different neurological test (p=0.027). The Stroop task and OWT were not significantly different (p=0.103, p=0.131 respectively). There were significant differences in many of the psychological and mobility questions posed (reliance on driving [p<0.001], keenness to return [p=0.014], anxiety about being unable to drive [p=0.019], depression at being unable to drive [p=0.011], worries that driving would cause them pain [p<0.001], and confidence in using public transport [p=0.002]). Activity rankings also had a significant difference, with driving becoming a higher priority in the patient group (p=0.002). There were no significant differences between cohorts in physical testing, but LEFS was significantly different (p<0.001). There was no significant correlation between physical testing and neurological function, so we cannot prove nor disprove that neurological deficits affect physical function. Psychological variables and physical function did not correlate, but LEFS was correlated to a number of psychological variables. Conclusions. Due to the insignificance of correlations between neurological function tests and physical function, further work is recommended to conclusively determine whether there is a link or not. Different and/or additional neurological test batteries should be also considered, for example the CANTAB. Future studies should stratify cohorts based on surgical indication. Extension of the psychological research could identify the most popular goals or activities for those returning from surgery, potentially creating targets for the rehabilitation process


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 700 - 704
1 Jul 1999
Sochart DH Hardinge K

We have studied the relationship between movements of the foot and ankle and venous blood flow from the lower limb using colourflow Duplex ultrasound to determine the optimum type of exercise for promoting venous return. Studies of both active and passive movements were carried out on 40 limbs in 20 subjects (18 men; 2 women), with a median age of 27 years (20 to 54). We assessed ankle dorsiflexion and plantar flexion, subtalar inversion and eversion, and a combination of all movements. There was no difference in venous flow when comparing opposite limbs in a single subject (p > 0.5), but active exercises produced higher peak and mean velocities of blood flow than passive ones. The active combined movement produced the highest velocities with an increase of 38% in mean and of 58% in peak flow velocities, which were significantly greater than the peak and mean flow rates produced by passive movements. The active combined exercise would therefore be the most effective in eliminating stasis and could contribute to the prevention of deep-vein thrombosis


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 73 - 73
1 Nov 2021
Camera A Tedino R Cattaneo G Capuzzo A Biggi S Tornago S
Full Access

Introduction and Objective

A proper restoration of hip biomechanics is fundamental to achieve satisfactory outcomes after total hip arthroplasty (THA). A global hip offset (GO) postoperatively reduction of more than 5 mm was known to impair hip functionality after THA. This study aimed to verify the restoration of the GO radiographic parameter after primary THA by the use of a cementless femoral stem available in three different offset options without length changing.

Materials and Methods

From a consecutive series of 201 patients (201 hips) underwent primary cementless THA in our centre with a minimum 3-year follow up, 80 patients (80 hips) were available for complete radiographic evaluation for GO and limb length (LL) and clinical evaluation with Harris hip score (HHS). All patients received the same femoral stem with three different offset options (option A with – 5 mm offset, option B and option C with + 5 mm offset, constant for each sizes) without changing stem length.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 12 - 12
1 Apr 2012
Menna C Deep K
Full Access

Total knee arthroplasty (TKA) is a common orthopaedic procedure. Traditionally the surgeon, based on experience, releases the medial structures in knees with varus deformity and lateral structures in knees with valgus deformity until subjectively they feel that they have achieved the intended alignment. The hypothesis for this study was that deformed knees do not routinely require releases to achieve an aligned lower limb in TKA. A single surgeon consecutive cohort of 74 patients undergoing computer navigated TKA was examined. The mechanical axes were taken as the references for distal femoral and proximal tibial cuts. The trans-epicondylar axis was taken as the reference for frontal femoral and posterior condylar cuts. A soft tissue release was undertaken after the bony cuts had been made if the mechanical femoro-tibial (MFT) angle in extension did not come to within 2° of neutral as shown by computer readings. The post-operative alignment was recorded on the navigation system and also analysed with hip-knee-ankle (HKA) radiographs. The range of pre-operative deformities on HKA radiographs was 15° varus to 27° valgus with a mean of 5° varus (SD 7.4°). Only two patients required a medial release. None of the patients required a lateral release. The post implant navigation value was within 2° of neutral in all cases. Post-operative HKA radiographs was available for 71 patients. The mean MFT angle from radiographs was 0.1° valgus (SD 2.1°). The range was from 6° varus to 7° valgus but only six patients (8.5%) were outside the ±3° range. The kinematic analysis also showed it to be within 2 degrees of neutral throughout the flexion making sure it is well balanced in 88% cases. This series has shown that over 90% of patients had limbs aligned appropriately without the need for routine soft tissue releases. The use of computer assisted bone cuts leads to a low level of collateral release in TKA