Postoperative stiffness is a relatively uncommon issue in total knee arthroplasty (TKA). However, it can be a debilitating complication when it occurs. Manipulation under anesthesia (MUA) is commonly used as the primary treatment modality following failed physiotherapy. The ADVANCE®
Introduction. In total knee arthroplasty, the aim is to relieve pain and provide a stable, functional knee. Sagittal stability is crucial in enabling a patient to return to functional activities. Knee implants with a medial pivot (MP) design are thought to more accurately reproduce the mechanics of the native joint, and potentially confer greater antero-posterior stability through the range of flexion than some other implant designs. Aim. This study aims to compare the sagittal stability of four different total knee arthroplasty implant designs. Method. Comparison was made between four different implant designs: medial pivot (MP), two different types of cruciate retaining (CR1 and CR 2) and deep dish (DD). A cohort of 30
INTRODUCTION. The purpose of TKA is to restore normal kinematics and functioning to diseased knees. The purpose of this study was to determine whether intraoperative kinematic data are correlated with minimum one-year outcomes following primary TKA. METHODS. We reviewed data on 185 consecutive primary TKAs in which sensor-embedded tibial trials were used to evaluate kinematic patterns following traditional ligament balancing. Procedures were performed by two board-certified arthroplasty surgeons. The same implant design and surgical approach was used for all knees. Contact locations on the medial and lateral condyles were recorded for each patient at 0°, 45° and 90° of flexion, and full flexion. Vector equations were created by contact locations on the medial and lateral sides and the vector intersections determined the center of rotation between each measurement position. Center of rotation was calculated as the average of vector intersections at 0 to 45°, 45 to 90°, and 90° to full flexion. If the average center of rotation was between 16 and 1000 mm of the contact location on the medial side it was considered a
In order to emulate normal knee kinematics more closely and thereby potentially improve wear characteristics and implant longevity the Medial Pivot type knee replacement geometry was designed. In the current study the clinical and radiographic results of 50 consecutive knee replacements using a Medial Pivot type knee replacement are reported; results are compared to the Australian Orthopaedic Associations National Joint Replacement Registry. The patients' data were crossed checked against the registry to see if they had been revised elsewhere. After a mean follow-up of 9.96 years results show that the Medial Pivot Knee replacement provides good pain relief and functional improvement according to KSS and Womac scores and on subjective patient questionnaires. There was one minor revision; insertion of a patella button at 6.64 years FU. There were no major revisions; all implants appeared to be well fixed on standard radiographic examination. While the revision rate for the
Distal femoral fractures in elderly patient occurred with lower energy injury due to preexisting osteoporosis. Gonarthrosis is frequently accompanied in these patients, and which is difficult to treatment and hard to restore function. Traditionally, the fractures in osteoarthritic knee are treated by open reduction and internal fixation (ORIF) and total knee arthroplasty (TKA) for osteoarthritis is considered after bone union of the prior fractures. However two-stage procedure makes some problems when TKA is performed following long immobilization, previous scar, implant removal, prolonged hospital stay, and increased cost. Several authors have reported acceptable results of primary TKA with concomitant ORIF using long stem with hinged, constrained type or posterior stabilized prosthesis, but which generally need substantial bone removal for notch preparation and is disadvantageous for the fractured extremity. We report 5 patients who were treated with primary TKA with concomitant ORIF for osteoarthritic knee accompanied by distal femoral fracture using ADVANCE
Most total knee prostheses are designed to have limited congruence between the femoral and tibial components to reduce constraint, based on the widely accepted principle that “constraint causes loosening”. Studies of the normal knee, however, indicate that stability under axial load occurs mostly by the geometric conformity of the surfaces. When moving in the plane of flexion-extension, the ligaments contribute little to stability because the ligaments are in the “toe-region” of their force-displacement curve. When an “out-of-plane” load is applied (i.e., load outside the plane of flexion-extension), ligaments are “recruited” for stability by being stressed into the elastic portion of the curve to resist the load. For the traditional total knee prosthesis, because of the lack of geometric congruity, the ligaments must provide all stability by being “balanced”, i.e. tensioned into the elastic portion of the force-displacement curve. Further, they must remain in that tensioned state indefinitely, with no stretching or migration of the implant. The
Background. In recent literatures, medial instability after TKA was reported to deteriorate early postoperative pain relief and have negative effects on functional outcome. Furthermore, lateral laxity of the knee is physiological, necessary for
Purpose. The purpose of this study was to compare the clinical and radiological results after total knee arthroplasty(TKA) with PCL sacrificing (PCS)
Backgrounds. Most of in vivo kinematic studies of total knee arthroplasty (TKA) have reported on varus knee. TKA for the valgus knee deformity is a surgical challenge. The purposes of the current study are to analyze the in vivo kinematic motion and to compare kinematic patterns between weight-bearing (WB) and non-weight-bearing (NWB) knee flexion in posterior-stabilized (PS) fixed-bearing TKA with pre-operative valgus deformity. Methods. A total of sixteen valgus knees in 12 cases that underwent TKA with Scorpio NRG PS knee prosthesis operated by modified gap balancing technique were evaluated. The mean preoperative femorotibial angle (FTA) was 156°±4.2°. During the surgery, distal femur and proximal tibia was cut perpendicular to the mechanical axis of each bone. After excision of the menisci and cruciate ligaments, balancer (Stryker joint dependent kinematics balancer) was inserted into the gap between both bones for evaluation of extension gap. Lateral release was performed in extension. Iliotibial bundle (ITB) was released from Gerdy tubercle then posterolateral capsule was released at the level of the proximal tibial cut surface. If still unbalanced, pie-crust ITB from inside-out was added at 1 cm above joint line until an even lateral and medial gap had been achieved. Flexion gap balance was obtained predominantly by the bone cut of the posterior femoral condyle. Good postoperative stability in extension and flexion was confirmed by stress roentgenogram and axial radiography of the distal femur. We evaluated the in vivo kinematics of the knee using fluoroscopy and femorotibial translation relative to the tibial tray using a 2-dimentional to 3-dimensional registration technique. Results. The average flexion angle was 111.3°±7.5° in weight-bearing and 114.9°±8.4° in non-weight-bearing. The femoral component demonstrated a mean external rotation of 5.9°±5.8° in weight-bearing and 7.4°±5.2° in non-weight-bearing (Fig.1). In weight-bearing, the femoral component showed medial pivot pattern from 0° to midflexion and a bicondylar rollback pattern from midflexion to full flexion (Fig2). Medial condyle moved similarly in non-weight-bearing condition and in weight-bearing condition. Lateral condyle moved posterior in slightly earlier angle during weight-bearing condition than during non-weight-bearing condition (Fig.3). Discussion. Numerous kinematic analyses of a normal knee have demonstrated greater posterior motion of the lateral femoral condyle relative to the medial condyle, leading to a mean external rotation and a bicondylar rollback motion with progressive knee flexion. A kinematic analysis of valgus knee was reported to show a different kinematic pattern from a physiological knee motion. Many valgus knees showed paradoxical anterior translation from extension to mid-flexion and greater posterior translation in the medial condyle than in the lateral condyle. Kitagawa et al. reported that this non-physiologic pattern wasn't completely restored after TKA using
Total Knee Artroplasty (TKA) is becoming more and more popular, even in the younger active age group. In this age group however the results are not that reproducible as in the older age group. People are more limited in their activities of daily living and complain more about pain, stifness and swelling. At the end and in general the younger age group is less satisfied than the older patients. The last decade minimal invasive solutions with modified instruments, Gender Knees, the use of navigation in TKA, ligament-based techniques, fast rehab protocols etc have all been introduced to make the results of TKA better. These are all elements that indeed can make the patient better. However the most important on the short term and the long term is the use of the correct implant size and the correct implantation of the prosthetic components. Since January 2011 we routinely use patient specific instruments in TKA patients under 60y that are very active or in older less active patients with important anatomic malformations. A CT-based system that scans the hip-knee-ankle is used. The data are sent to an engineer and a digital proposal is sent back to the surgeon that can approve the different measurements performed. Once approved the patient specific cutting blocks are sent to the surgeon. In our department we use the Advance
Ligament releases are necessary for contemporary non-conforming femoral-tibial articulations. Most total knee arthroplasty prostheses are designed to be non-conforming at the articulation between the femoral and tibial components. This design is chosen on the arthroplasty principle that “constraint causes loosening” and conforming surfaces have been considered constrained. To provide stability the ligaments are adjusted so that tension in the ligament can provide stability for the total knee replacement. Ligament releases are NOT necessary for contemporary conforming femoral-tibial articulations. Through the majority of the range of motion, the normal human knee is not stabilised by ligament tension. Rather, it is the geometrical conformity of the femur and tibia, especially on the medial side, that provides stability. The ligaments are present and ready to restrain the knee from excess varus-valgus or anterior-posterior loads. In a knee design that is congruent, ligaments may be left intact as in the normal knee, ready to provide restraint but not necessarily to provide stability except when excess loads are applied to the knee. When designing and using the ADVANCE