Resection of the proximal femur raises several challenges to the orthopedic oncology surgeon. Among these is the re-establishment of the abductor mechanism that might impacts on hip function. Extent of tumor resection and surgeons’ preferences dictate the reconstruction method of the abductors. While some surgeons advocate the necessity of greater trochanter (GT) preservation whenever possible, others attempt direct soft tissues reattachment to the prosthesis. Sparse data in the literature evaluated the outcomes of greater trochanter fixation to the proximal femur
Aim. Megaprosthesis have become a standard option in limb preserving surgery after bone resection in musculoskeletal tumors. Recently they have also been used in complex revision arthroplasty in cases with massive bone loss. The aim of this study was to analyze the incidence of periprosthetic joint infection (PJI) both in primary oncology cases and aseptic revision cases and analyze which are the significant risk factors for PJI with a special interest on the use of prophylactic antibiotic loaded calcium sulfate beads. Method. All patients undergoing surgery with the use of
Aim. Periprosthetic joint infections are a devastating complication after modular endoprosthetic reconstruction following resection of a musculoskeletal tumour. Due to long operating times, soft tissue dissection and immunosuppression, the infection rate after limb salvage is high and ranges between 8% and 15%. The aim of this retrospective single centre study was to assess the reinfection and re-reinfection rate after septic complications of megaprostheses. Method. In this retrospective study, 627 patients with a primary replacement of a musculoskeletal tumour of the lower limb and reconstruction by a
Introduction. The development of new
Aim. Rifampicin and fluoroquinolone based therapy is generally considered as first-choice targeted oral antimicrobial therapy for staphylococcal prosthetic joint infections (PJI) treated with debridement, antibiotics and implant retention (DAIR). Alternative equally effective antimicrobial strategies are urgently needed due to toxicity and drug-drug interactions that frequently occur with this strategy. Data from recent clinical studies suggests equipoise for other antimicrobial treatment regimens. The objective of the Rifampicin Combination Therapy versus Targeted Antimicrobial Monotherapy in the Oral Antimicrobial Treatment Phase of Staphylococcal Prosthetic Joint Infection (RiCOTTA)-trial is to evaluate whether monotherapy with clindamycin is non-inferior to rifampicin/fluoroquinolone combination therapy in patients with staphylococcal PJI that are treated with DAIR. Method. The RiCOTTA-trial is a multicenter, non-inferiority, open-label, randomized controlled trial evaluating clindamycin versus rifampicin/fluoroquinolone combination therapy in the oral treatment phase in patients with staphylococcal PJI managed with DAIR. The trial is performed in 16 hospitals in the Netherlands. Eligible patients are adults with staphylococcal knee or hip PJI managed by DAIR. Patients are included one to six days before antibiotic treatment is switched from intravenous to oral therapy. Patients with a contraindication for rifampicin, with a
INTRODUCTION. Recently the evolution of prosthesis technology allows the surgeon to replace entire limbs. These special prostheses or megaprostheses were born for the treatment of severe oncological bone loss. Recently, however, the indications and applications of these devices are expanding to other orthopaedic and trauma situations. Since some years we are implanting megaprostheses in non-oncological conditions such as septic post-traumatic failures represented by complex non-unions and critical size bone defects. The purpose of this study is to retrospectively evaluate the clinical outcome of this treatment and register all the complications and infection recurrence. MATERIAL AND METHOD. Between January 2008 and January 2016 we have treated 55 patients with septic post-traumatic bone defects In 48/55 cases we perform a 2 steps procedure: 1° step: resection, debridment, devices removal and antibiotic spacer implantation; 2° step: spacer removal and
The use of new
Introduction:. The development of new prostheses due to large resections has offered important opportunities to orthopedic surgeons mainly in oncology. A medline research can easily underline how poor is the international experience about this cases in nonunion: 75 results for
Introduction. Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses. 1. In a knee simulator study, Kretzer. 2. , demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. Patients and Methods. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a
Introduction. Bone loss management represents one of the most challenging issues for the orthopaedic surgeon. In most cases, stems, structural allograft, TMcones, and sleeves are adequate to allow optimal implant stability and durable fixation. In selected cases of wide metadiaphyseal bone defects, these devices do not provide proper intraoperative stability. In such scenarios, further steps are needed and include complex modular reconstruction, substitution with
Introduction. Various anti-infective agents can be added to the surface of orthopaedic implants to actively kill bacteria and prevent infection. Silver (Ag) is a commonly used agent in various anti-infective applications. Silver disrupts bacterial membranes and binds to bacterial DNA and to the sulfhydryl groups of metabolic enzymes in the bacterial electron transport chain, thus inactivating bacterial replication and key metabolic processes. Recently we are implanting Silver coated
Introduction. Throughout the world the number of large joint arthroprosthetic implants continues to increase and consequently the number of septic complications with prosthesis mobilizations, periprostehtic bone loss or non-unions. The implant of large resection prosthesis (megaprosthesis) in selected patients could be a good solution both in hip and knee infected prosthesis with bone defects. The two stage techniques with a first operation to debride, prosthesis components removal and antibiotic spacer implantation followed by a subsequent final prosthetic implant offer great results even in highly complex patients. Objectives. The purpose of this study is to evaluate retrospectively the outcome after the implantation of
Introduction. In orthopaedics one of the most common complications is infection. The occurrence of a postoperative infection significantly increases the failure rate; both in the case of prosthetic and trauma surgery. Some patients despite a meticulous antiseptic procedures, a close monitoring of controls peri- and post-operative undergo the development of infection of the fixation devices with the risk of developing osteomyelitis. This risk is highly increased in the distal leg because of the known problems with blood supply and poor muscle coverage. The functionality of the affected segment is impaired, quoad fuctionem, with increased risk of amputation and sometimes with poor prognosis, quoad vitam. The therapeutic strategy proposed by our group is to treat an osteomyelitic site as a pseudo-tumor with a megaimplant following a ladder strategy driven by the NUSS classification. This work shows our experience with a developing system by Waldemar-LINK highlighting critical issues and preliminary results. Objectives. The purpose of this study is to evaluate retrospectively the early outcome after the implantation of this
Peri-prosthetic fractures above a TKA are becoming increasingly more common, and typically occur at the junction of the anterior flange of the femoral component and the osteopenic metaphyseal distal femur. In the vast majority of cases the TKA is well fixed and has been functioning well prior to fracture. For loose components, revision is typically indicated. Typically a
Peri-prosthetic fractures above a total knee arthroplasty (TKA) are becoming increasingly more common, and typically occur at the junction of the anterior flange of the femoral component and the osteopenic metaphyseal distal femur. In the vast majority of cases the TKA is well-fixed and has been functioning well prior to fracture. For loose components, revision is typically indicated. Typically a
Despite our best efforts, occasionally, certain patients will have multiply operated, failed reconstructions after TKA. There are situations where further attempts at arthroplasty are unwise, for example, chronic infections with multiple failed staged reconstructions. A careful pre-operative evaluation of the patient is critical to guide decision-making. An assessment of medical comorbidity, functional demands, and expectations is important. Regarding the extremity, the severity of bone loss, soft tissue defects, ligamentous competency, and neurovascular status is important. The next step is to determine whether the knee is infected. The details of such a workup are covered in other lectures, however, the author prefers to aspirate all such knees and obtain C reactive protein and sedimentation rates. For equivocal cases, PCR may be helpful. If no infection is present, complex reconstruction is considered. Segmental
Despite our best efforts, occasionally, certain patients will have multiply operated, failed reconstructions after TKA. There are situations where further attempts at arthroplasty are unwise, for example, chronic infections with multiple failed staged reconstructions. A careful preoperative evaluation of the patient is critical to guide decision-making. An assessment of medical comorbidity, functional demands, and expectations is important. Regarding the extremity, the severity of bone loss, soft tissue defects, ligamentous competency, and neurovascular status is important. The next step is to determine whether the knee is infected. The details of such a workup are covered in other lectures, however, the author prefers to aspirate all such knees and obtain C reactive protein and Sedimentation Rates. For equivocal cases, PCR may be helpful. If no infection is present, complex reconstruction is considered. Segmental
Purpose. Durable fixation may be difficult to achieve when significant bone loss is present, as it occurs in pelvic sarcoma resection and revision surgery of tumor implants. Purpose of this study was to review clinical results of primary and revision surgery of the pelvis and lower extremity in the setting of severe bone loss following limb salvage procedures for bone sarcoma using modular porous tantalum implants. Method. Retrospective study of 15 patients (nine females, six males) undergoing primary or revision pelvic reconstruction (five patients) or revision surgery of a tumor implant of the hip (five patients), knee (four patients), and ankle (one patient) using porous tantalum implants was undertaken. Reason for the tumor implant was resection of bone sarcoma in 13 cases and tumor-like massive bone loss in the remaining two cases. Cause for revision was aseptic failure (nine patients) or deep infection (six patients); average age at the time of surgery was 31 years (16–61 yrs). Revision was managed in a staged fashion in all the six infected cases. All patients presented severe combined segmental and cavitary bone defects. Bone loss was managed in all patients using porous tantalum implants as augmentation of residual bone stock and associated with a