The diagnosis of infection following shoulder arthroplasty is notoriously difficult. The prevalence of prosthetic shoulder infection after arthroplasty ranges from 3.9 – 15.4% and the most common infective organism is Cutibacterium acnes. Current preoperative diagnostic tests fail to provide a reliable means of diagnosis including WBC, ESR, CRP and joint aspiration. Fluoroscopic-guided percutaneous synovial biopsy (PSB) has previously been reported in the context of a pilot study and demonstrated promising results. The purpose of this study was to determine the diagnostic accuracy of percutaneous synovial biopsy compared with open culture results (gold standard). This was a multicenter prospective cohort study involving four sites and 98 patients who underwent revision shoulder arthroplasty. The cohort was 60% female with a mean age was 65 years (range 36-83 years). Enrollment occurred between June 2014 and November 2021. Pre-operative fluoroscopy-guided synovial biopsies were carried out by
Myxofibrosarcoma (MFS) is the second most common subtype of soft tissue sarcoma (STS) and is associated with a high rate of local recurrence after resection. These tumours frequently present with peri-lesional edema, termed “tumour tails” on staging MRI scans [1]. Tumour tails(TT) may contain satellite neoplastic cells or can represent benign reactive edema. There are no clear radiological features to distinguish malignant from reactive peri-lesional edema which limits accurate surgical planning, resulting in either high rates of inadvertently positive resection margins and local recurrences or overly-aggressive resections which negatively impact function and increase morbidity [2]. The objective of this pilot study was to prospectively study a cohort of MFS patients with TTs in an attempt to identify radiological features that predict which type of edema is malignant and requires resection together with the main tumour mass. Patients diagnosed with MFS on biopsy at an orthopaedic oncology referral centre between January 1-December 31 2018 who also had TTs on staging MRI scans were prospectively recruited for the study. Tumours were treated with wide surgical excision, including the TTs, and (neo)adjuvant radiotherapy as per institutional protocol. Staging MRI scans were reviewed in a blinded fashion by two
The final alignment of Patient Specific Instrumentation (PSI) TKA relies on the accuracy and the correct placement of the 3-D moulds, precision of saw cuts, soft tissue balancing and cementing technique. We aimed to compare the predicted alignment between PSI and Articulated Surface Mounted (ASM) computer navigation. Eight consecutive patients underwent knee replacement using MRI based PSI (Zimmer) with planning of 0º femoral and tibial mechanical alignment. After placing the conventional cutting blocks over the pins (placed according to PSI), the predicted alignment of cuts was verified with ASM navigation. PSI technique was used regardless of navigation values and alignment was compared. Good correlation was found for tibial cuts (maximum variation: coronal plane – 1º, sagittal plane – 2º) and femoral cuts in the sagittal plane (maximum variation 2º). However, in two patients the coronal plane variation in femur was > 2º (3º and 4º respectively). Navigation predicted combined final alignment of 5º valgus and 4º valgus in these patients. However, long leg standing x-rays revealed neutral and 1º valgus alignment in those two patients respectively, matching closely with PSI prediction. Final alignment in long-leg standing x-rays were independently reported by a
Hamstring tendons are commonly used for Anterior Cruciate Ligament (ACL) reconstruction. In our series of 100 consecutive Hamstring ACL reconstructions, a four-strand graft was less than 7.0 mm in 5 patients. The aim of this study was to develop a screening test to assess the size of the hamstring tendon and so aid in the pre operative planning and patient counselling especially if hamstring size was deemed to be inadequate. A retrospective study of 100 consecutive hamstring ACL reconstructions analysed the correlation of the tendon size to height, weight and body mass index. A prospective double blind study was also set up involving independent observations by a
Introduction. Most of the algorithm available today to balance varus knee is based on a surgeon's hands-on experience without full understanding of pathological anatomy of varus knee. The high-resolution MRI allows us to recognize the anatomical details of the posteromedial corner and the changes of the soft tissue associated with the osteoarthritis and varus deformity. We have in this study, reviewed 60 cases of severe varus knee scheduled for TKR and compared it to normal MRI and those MRI were evaluated and read by a
The orientation of the acetabular component in metal-on-metal hip resurfacing arthroplasty affects wear rate and hence failure. Correct assessment of acetabular orientation is key in assessing the painful hip resurfacing. This study aimed to establish if interpretation of pelvic radiographs with TraumaCad software can provide a reliable alternative to computed tomography (CT) in measuring the acetabular inclination and version. TraumaCad was used to measure the acetabular orientation on AP pelvis radiographs of 14 painful hip resurfacings. Four orthopaedic surgeons performed each measurement twice. These were compared with measurements taken from CT reformats performed by an experienced
Introduction. In the evaluation of patients with pre-arthritic hip disorders, making the correct diagnosis and identifying the underlying bone pathology is of upmost importance to achieve optimal patient outcomes. 3-dimensional imaging adds information for proper preoperative planning. CT scans have become the gold standard for this, but with the associated risk of radiation exposure to this generally younger patient cohort. Purpose. To determine if 3D-MR reconstructions of the hip can be used to accurately demonstrate femoral and acetabular morphology in the setting of femoroacetabular impingement (FAI) and development dysplasia of the hip (DDH) that is comparable to CT imaging. Materials and Methods. We performed a retrospective review of 14 consecutive patients with a diagnosis of FAI or DDH that underwent both CT and MRI scans of the same hip with 3D reconstructions. 2 fellowship trained
The TruFit® plug is a cylindrical scaffold designed to bridge defects in articular cartilages. It is a porous structure with interconnected pores, which gives it the capability of providing a framework for the ingrowth new tissue and remodelling to articular cartilage and bone. The aim of this study was to assess the radiological incorporation of TruFit® Plugs using MRI. Between December 2007 & August 2009, 22 patients underwent treatment of a chondral or osteochondral lesion using one or more TruFit Plugs. At a minimum of 2 years, 10 patients (12 lesions) were MRI scanned and assessed with a modified MOCART Scoring system by an independent Consultant
The aim of this prospective study was to determine the prevalence of bone marrow oedema (BME) in asymptomatic knees of athletes and to investigate the factors associated with appearance of BME in this group. A total of 25 asymptomatic athletes who competed at an international, national or county level during their most recent sport season were recruited in this study and had MRI scan of both knees (n=50). MRI scans were reported independently by two experienced
Introduction. High early failure rates have been reported with certain metal-metal surface arthroplasties and good results have been reported with others. This is a minimum 10-year review of the first 1000 consecutive resurfacings including all ages and diagnoses from one centre. Methods. The first 1000 surface arthroplasties (892 patients) were followed-up with postal questionnaires. Of these the first 402 hips (350 patients) were also invited for a clinico-radiological review. 54 patients (63 hips) died 6.7 years (0.7–12.6) later due to unrelated causes. Mean follow-up is 12.2 years (range 10.8–13.7). Radiographs were assessed independently by a senior
Glenoid loosening is a major problem in total shoulder arthroplasty. Failure of osteointegration, osteolysis and loosening are potential problems with concerning reports of these complications with earlier metal back designs. CT scans have been reported as more accurate than plain x-rays in examining fixation of components. This study examines the medium term osteointegration of the SMR (Lima) metal back glenoid component. 20 consecutive patients operated on by the same surgeon (KM) were evaluated at a mean of 3 years 9 months (range 3-5 years) using CT analysis. Films were read by a
Introduction. The use of metal-on-metal (MOM) and modular total hip arthroplasty (THA) is associated with potentially serious complications including elevated serum metal ion levels, pseudotumor, cardiomyopathy and neurologic abnormalities. The primary aim of this analysis was to identify any associations between the presence of pseudotumor, serum metal ion levels, and specific dual modular implant components. Methods. We evaluated prospectively collected data from 49 patients, mean age 58.4 years, who underwent implantation of modular THA from 01/2004-01/2010. The collected data spanned a 5–11 year period from the time of index procedure. Serum metal ion levels, including titanium, cobalt and chromium, were collected in 2012 and 2015. Hip ultrasounds were performed on each patient by a trained
Introduction. Literature in respect to the MRI appearances of surgically confirmed spring ligament pathology is sparse. The authors conducted a retrospective review of MRI examinations comprising 13 patients with surgically proven spring ligament abnormality. Methods. Records for operations performed for planovalgus foot deformity with operation notes confirming presence of spring ligament abnormality were obtained for patients treated 2010–11. Of 32 procedures 13 patients (3 male, 10 female) mean age 48.5 (range, 21–86 years) underwent preoperative MRI scanning using a standard musculoskeletal protocol on a T1.5 unit. Scans were retrospectively reviewed by one of the senior authors and consultant
Purpose. Rectus femoris avulsion (RFA) injuries in paediatric patients are currently managed conservatively. However, the proximal attachment of the rectus femoris muscle lies in a critical zone in the hip joint with attachments to the anterior hip capsule and anterior inferior iliac spine. Violent avulsions therefore could cause damage to the adjacent acetabular labrum and articular cartilage initiating a process leading to early degenerative changes in the hip. To date, the association between rectus avulsions and labral tears has not been studied. Method. The complete medical records of patients who were presented to McMaster University Medical Center with rectus femoris avulsions between 1983 and 2008 who were between the ages of 2 and 18 were identified. Patients were included if they had documented plain radiographs and magnetic resonance arthrography images of their hip. MRIs were reviewed by an independent
Background. It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome. Methods. A retrospective study of patients undergoing primary THR at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant
Aim. This study reviewed the efficacy of a CT arthrogram in clinical decision making for wrist disorders. Methods. Sixty four consecutive CT arthrograms done in a three year period at Glenfield Hospital were selected. All patients were referred by hand consultants at the Glenfield Hospital and all investigations were performed by a single senior
Introduction. Chronic Achilles tendinopathy is a common overuse injury. There are several modalities of treatment, reflecting difficulties in its management. In particular, due to the well-recognised morbidity associated with surgical decompression, treatment has steered towards a less invasive route. Dry needling has been efficacious in managing other tendinopathies. This study therefore assessed dry needling and percutaneous hydrostatic decompression of the Achilles tendon as a novel treatment for this condition. Methods. Twenty-two patients with 27 sonographically-confirmed chronic Achilles tendinopathy were prospectively enrolled. All were symptomatic for >6 months and have failed alternative conservative treatments. Ultrasound-guided dry needling of neovascular areas and paratenon hydrostatic decompression was performed by a dedicated
Introduction. We reports the accuracy of direct Magnetic Resonance Arthrography (MRA) in detecting Triangular Fibrocartilage Complex (TFCC), Scapho-Lunate Ligament (SLL) and Luno-Triquetral Ligament (LTL) tears using wrist arthroscopy as the gold standard. Methods. We reviewed the records of all patients who underwent direct wrist MRA and subsequent arthroscopy over a 4-year period between June 2007 and March 2011. Demographic details, MRA findings, arthroscopy findings and the time interval between MRA and arthroscopy were recorded. The scans were performed using a 1.5T scanner and a high resolution wrist coil. All scans were reported by a
Despite the high success rates of Reverse Shoulder replacements, complications of instability & scapular notching are a concern. Factors reducing relative motion of implant to underlying bone which include lateral offset to centre of rotation, screw & central peg insertion angle and early osteo-integration are maximized in the Trabecular Metal Reverse total shoulder system. We present clinico-radiological outcomes over 72 months. Analysis of a single surgeon series of 140 Reverse total shoulder replacements in 135 patients was done. Mean age was 72(range 58– 87 yrs); 81 females: 54 males. Indications were Rotator cuff arthropathy {n= 88} (63%); Osteo-arthritis with dysfunctional cuff {n= 22}(15%); post-trauma{n=23} (15%); revision from hemiarthroplasty {n=3} (2.4%) and from surface replacement {n=4} (2.8%). All patients were assessed using pre-operative Constants and Oxford scores and clinical & radiographic reviews with standard X-Rays at 6 weeks, 3, 6,12 months and yearly thereafter. X rays included an AP view in 45 degrees of external rotation and modified axillary view. Inferior Scapular notching using the Nerot-Sirveaux grades and Peg Glenoid Rim Distance were looked into by a consultant
Introduction:. Reverse total shoulder arthroplasty (RTSA) has become instrumental in relieving pain and returning function to patients with end-stage rotator cuff disease. A distalized and medialized center of rotation in addition to a semi-constrained implant design allows the deltoid to substitute for the non-functioning rotator cuff. The purpose of this study was to examine the relationship between specific deltoid and rotator cuff muscle parameters and functional outcomes following RTSA. Methods:. Patients undergoing RTSA by a single surgeon were enrolled in a prospective, IRB approved RTSA outcomes registry. Inclusion criteria were diagnosis of cuff tear arthropathy or massive rotator cuff tear, a minimum 2-year follow-up, and a preoperative shoulder MRI. We excluded patients undergoing revision arthroplasty, fracture, and a history of previous open shoulder surgery. For the 28 patients meeting our criteria, the cross-sectional area (CSA) of the anterior, middle, and posterior deltoid were measured on an axial MRI (Figure 1). Fatty infiltration (FI) of the deltoid, supraspinatus (SS), infraspinatus (IS), teres minor, and subscapularis were assessed on sagittal T1-MRI quantitatively via image processing and qualitatively on the 5-point Fuchs scale by a fellowship-trained