Background. Isolated fracture of the greater trochanter is an uncommon presentation of hip fracture. Traditional teaching has been to manage these injuries nonoperatively, but modern imaging techniques have made it possible to detect occult intertrochanteric extension of the fracture in up to 90% of cases. This study aims to review the investigation and management of greater trochanter fractures in a single major trauma centre. Methods. A retrospective review was completed of patients admitted with greater trochanter fractures. These were matched to cases with 2-part extracapsular fractures. Initial management and clinical outcome was established using electronic notes and radiographs. Mortality and length of stay was calculated for both groups. Results. 85 isolated greater trochanter fractures in 84 patients were identified from 2006–2017. 81/85 patients were treated non-operatively. 78 were mobilised full weight bearing. None required readmission or operation due to fracture displacement. 58 of these patients had cross-sectional imaging with MRI or CT and 15 of those scanned had intertrochanteric extension of the fracture. In the same time period, 998 2-part extra-capsular fractures were treated, using a sliding hip screw. Length of stay was shorter in patients with greater trochanter fractures than 2-part extracapsular fractures (median 7 days vs 14 days, P<0.0001). 30-day mortality was 11.9%, with no significant difference to patients with 2-part extracapsular fractures. Discussion. Cross sectional imaging rarely changed the treatment protocol for isolated greater trochanter fractures. The outcome following non-operative treatment is good even in the presence of
Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model. Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods.Aims
Methods
The main aims were to identify risk factors predictive of a radiolucent line (RLL) around the acetabular component with an interface bioactive bone cement (IBBC) technique in the first year after THA, and evaluate whether these risk factors influence the development of RLLs at five and ten years after THA. A retrospective review was undertaken of 980 primary cemented THAs in 876 patients using cemented acetabular components with the IBBC technique. The outcome variable was any RLLs that could be observed around the acetabular component at the first year after THA. Univariate analyses with univariate logistic regression and multivariate analyses with exact logistic regression were performed to identify risk factors for any RLLs based on radiological classification of hip osteoarthritis.Aims
Methods
We assessed the difference in hospital based and early clinical
outcomes between the direct anterior approach and the posterior
approach in patients who undergo total hip arthroplasty (THA). The outcome was assessed in 448 (203 males, 245 females) consecutive
patients undergoing unilateral primary THA after the implementation
of an ‘Enhanced Recovery’ pathway. In all, 265 patients (mean age:
71 years (49 to 89); 117 males and 148 females) had surgery using
the direct anterior approach (DAA) and 183 patients (mean age: 70
years (26 to 100); 86 males and 97 females) using a posterior approach.
The groups were compared for age, gender, American Society of Anesthesiologists
grade, body mass index, the side of the operation, pre-operative
Oxford Hip Score (OHS) and attendance at ‘Joint school’. Mean follow-up
was 18.1 months (one to 50).Aims
Patients and Methods
Persistent groin pain after seemingly successful
total hip replacement (THR) appears to have become more common.
Recent studies have indicated a high incidence after metal-on-polyethylene
and metal-on-metal conventional THR and it has been documented in
up to 18% of patients after metal-on-metal resurfacing. There are many
causes, including acetabular loosening, stress fracture, and iliopsoas
tendonitis and impingement. The evaluation of this problem requires
a careful history and examination, plain radiographs and an algorithmic approach
to special diagnostic imaging and tests. Non-operative treatment
is not usually successful. Specific operative treatment depending
on the cause of the pain usually involves revision of the acetabular
component, iliopsoas tenotomy or other procedures, and is usually
successful. Here, an appropriate algorithm is described.