We have reviewed our experience of the removal of deep extremity
We have reviewed the complication rate over a ten year period for removal of screws placed for slipped capital femoral epiphysis (SCFE) and have surveyed the views of orthopaedic surgeons with an adult hip practice in Scotland on leaving the metalwork in situ. Whilst screw removal is favoured by many orthopaedic surgeons, a recent review of the literature reported that the complication rate for removal of implants placed for SCFE was 34%. Between 1998 and 2007 84 patients had insertion of screws for SCFE. Of these 54 patients had screws removed, 51 of these records were available. The median duration between insertion and removal of screws was 2 yrs 7 months. Of the 51 children, overall five (9.8%) had complications - three (5.9%) major and two (3.9%) minor. Two screws could not be removed; one patient sustained a fracture after screw removal and two developed an infection. We assessed the attitudes of adult hip surgeons on this topic using an electronic questionnaire which was completed by 29 out of 40 recipients. 78.6% of respondents support routine removal and 21.4% favour leaving the screw permanently in place. 82.2% had needed to remove metalwork from a hip requiring arthroplasty in a patient whose metalwork was inserted during childhood; and described their experience of this including the complications encountered. We have identified a lower complication rate following screw removal inserted for SCFE than in published series. Most adult hip surgeons support routine removal once the physis is closed but studies regarding the long-term outcome of retained