Advertisement for orthosearch.org.uk
Results 1 - 20 of 1456
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1555 - 1561
1 Nov 2015
Kwan MK Chiu CK Lee CK Chan CYW

Percutaneous placement of pedicle screws is a well-established technique, however, no studies have compared percutaneous and open placement of screws in the thoracic spine. The aim of this cadaveric study was to compare the accuracy and safety of these techniques at the thoracic spinal level. A total of 288 screws were inserted in 16 (eight cadavers, 144 screws in percutaneous and eight cadavers, 144 screws in open). Pedicle perforations and fractures were documented subsequent to wide laminectomy followed by skeletalisation of the vertebrae. The perforations were classified as grade 0: no perforation, grade 1: < 2 mm perforation, grade 2: 2 mm to 4 mm perforation and grade 3: > 4 mm perforation. In the percutaneous group, the perforation rate was 11.1% with 15 (10.4%) grade 1 and one (0.7%) grade 2 perforations. In the open group, the perforation rate was 8.3% (12 screws) and all were grade 1. This difference was not significant (p = 0.45). There were 19 (13.2%) pedicle fractures in the percutaneous group and 21 (14.6%) in the open group (p = 0.73). In summary, the safety of percutaneous fluoroscopy-guided pedicle screw placement in the thoracic spine between T4 and T12 is similar to that of the conventional open technique. Cite this article: Bone Joint J 2015;97-B:1555–61


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. Cite this article: Bone Joint J 2015; 97-B:1111–17


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 36 - 36
1 Jun 2023
Rashid L Trompeter A Saw A
Full Access

Introduction. Osteotomy is a key step in distraction osteogenesis. Various techniques of osteotomy have been described with its own benefits and pitfalls. Percutaneous osteotomy using multiple drill holes is one of the most widely used osteotomy techniques. It still remains a challenge however to keep the drill holes aligned prior to the osteotomy. Moreover, the efficacy of percutaneous irrigation practice to keep the temperature low during drilling with this technique is also debatable. With an aim to overcome these challenges, we are introducing a device called the Double Barrel Drill Sleeve (DBDS) to perform percutaneous osteotomies. We attempted to compare this method to the conventional multiple drill holes technique using laboratory experiments and clinical data. Materials & Methods. DBDS has two adjacent parallel barrels that can fit 3.2 to 3.5 mm diameter drill bits. It has a guide member at the drilling end that can be inserted through a pre drilled hole at the near and far cortices of a bone. This provides a constant rotating point for drilling of holes through the barrels. An osteotomy simulation was performed to compare percutaneous drilling with DBDS vis-a-vis a conventional single drill sleeve (SDS) by qualified orthopaedic surgeons, mainly to assess the drilling patterns of both techniques. Percutaneous drilling was done on PVC pipes wrapped in thick sponge to simulate tubular bone with surrounding soft tissue. We also assessed the effect of indirect irrigation on temperature during drilling using the DBDS against a control group on a cadaveric bone model. Ultimately we reviewed our patients who had undergone osteotomy for distraction osteogenesis with DBDS and the conventional technique, and compared their outcomes. Results. Completion time for the osteotomy simulation in the DBDS group was significantly faster than the conventional drilling group; 74 seconds to 179 seconds. There was significantly less drilling deviation from the midpoint in the DBDS group as compared to the SDS group. Mean bone temperature during drilling with indirect irrigation using DBDS was significantly lower (32.6'C) compared to the control group (48.4'C). There was no significant difference in healing index between patients treated with DBDS and the conventional method. None of these patients developed non union. Conclusions. Percutaneous drilling with DBDS was quicker and more linear compared to the conventional method. Its double-barreled feature allows effective indirect irrigation during drilling. A comparable healing index in both of the techniques shows its clinical efficacy. These attributes make DBDS a usefull tool to overcome some of the pitfalls associated with the conventional multiple drill holes technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 14 - 14
7 Nov 2023
Bhikha S
Full Access

When a suspicious spine lesion is identified, an accurate diagnosis based on tissue biopsy is needed to direct towards the correct treatment protocol. Several studies concluded that the percutaneous fluoroscopy guided biopsy of vertebral lesions is a safe, effective and accurate diagnostic tool and is preferred over open techniques when possible. The aim of this study was to review percutaneous fluoroscopy guided transpedicular spinal biopsies at a tertiary hospital over a 6-year period. The research design was a retrospective review of patients who underwent percutaneous transpedicular spinal biopsies under fluoroscopy guidance at a tertiary hospital over a six year period (1st January 2016 to the 31st December 2021). The spine theatre registry and hospital records system were used as the source for data collection. Statistical analysis was conducted to determine the effectiveness of transpedicular spinal biopsies, compare spinal pathology amongst age and gender and to identify any complications. The study analysed 180 biopsies, 120 yielding a positive result (66.67%). Of these 8.9% were pyogenic infection, 18.4% neoplasm, 36.7% Tuberculosis and 2.7% other. There were 75 males and 105 females with an age range between 9 and 86 years and mean age of 43.44. Comparing age and gender found no statistical significance (p = 0.778). Comparing biopsy result and gender showed no statistical significant relationship (p = 0.970). Comparison of biopsy result with age showed no statistical significant association (p = 0,545). Four complications were identified (2.22%). The study showed that fluoroscopy guided percutaneous transpedicular biopsy is an effective and safe modality in obtaining spinal specimens in all age groups for a wide spectrum of spinal pathological lesions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 17 - 17
10 Feb 2023
Weber A Dares M
Full Access

Percutaneous flexor tenotomy involves cutting the flexor digitorum tendons to correct claw toe deformity to treat apical pressure areas and prevent subsequent infection in patients with peripheral neuropathy. Performing this under ultrasound guidance provides reassurance of complete release of the tendon and increases procedural safety. This study is a retrospective case series evaluating the effectiveness, safety, and patient satisfaction of performing percutaneous ultrasound-guided flexor tenotomy in an outpatient setting. People with loss of protective sensation, a digital flexion deformity, and an apical toe ulcer or pre-ulcerative lesion who presented to our institution between December 2019 and June 2022 were included in this study. Participants were followed-up at a minimum of 3 months. Time to ulcer healing, re-ulceration rate, patient satisfaction, and complications were recorded. An Australian cost analysis was performed comparing this procedure performed in rooms versus theatres. There were 28 ulcers and 41 pre-ulcerative lesions. A total of 69 tenotomy procedures were performed on 38 patients across 52 episodes of care. The mean time to ulcer healing was 22.5 +/- 6.4 days. There were 2 cases of re-ulceration. 1 patient sustained a transfer lesion. There were four toes that went onto require amputation, all in the setting of pre-existing osteomyelitis. 94% of patients strongly agreed that they were satisfied with the outcome of the procedure. Costs saved were estimated to be $1426. Flexor tenotomy is a minimally invasive procedure that can be performed in the outpatient setting, and therefore without delay to treatment, reducing risk of ulcer progression and need for subsequent amputation. This is the first study to report on flexor tenotomy under ultrasound-guidance. Ultrasound-guided percutaneous flexor tenotomy is safe and effective, with high patient satisfaction and low recurrence rates. This performance in the outpatient setting ensures significant time and cost savings for both the practitioner and patient


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 30 - 31
1 Mar 2008
Narvani A Tsiridis E Ramachandran M Briggs T Cannon S Saifuddin A Mitchell R
Full Access

The aim of this study was to compare the accuracy of image guided (ultrasound or CT) percutaneous needle biopsy to percutaneous needle biopsy without image guidance in diagnosis of soft tissue tumours. Eighty-eight consecutive patients with soft tissue lesion who were referred to the soft tissue tumour unit underwent percutaneous needle biopsies of their lesion either with image guidance or without. Sixty-one out of these 88 patients subsequently underwent excision of their lesion and the excised specimen was then subjected to histological examination. The accuracy of image guided percutaneous needle biopsy and percutaneous needle biopsy without image was then calculated by comparing the histological results of the needle biopsy to that of excision biopsy. The diagnosis accuracy of image guided percutaneous needle biopsy was 92% (34 out 37) compared to 79% (22 out of 28) for percutaneous needle biopsy without image. In 3 out of the 28 patients who had percutaneous needle biopsy without image guidance, there was insufficient material obtained from the needle biopsy to allow a histological diagnosis. This was not the case with any of the patients who had image guided percutaneous needle biopsy. Conclusion: Using image guidance, either USS or CT scan, improves the diagnostic accuracy of percutaneous needle biopsy and should be the gold standard technique in management of soft tissue tumours. However, if the lesion is palpable and not mobile, the accuracy of percutaneous needle biopsy without image guidance can be up to 79%


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 33 - 33
1 Apr 2022
Chester J Trompeter A van Arkel R
Full Access

Introduction. Non-union is debilitating, costly and affects 2–8% of intramedullary fixed fractures. Clinical data suggest that percutaneous interfragmentary screws offer a less invasive alternative to exchange nailing. This study aimed to assess their efficiency with biomechanical analyses. Materials and Methods. A tibia was prepared for finite element analysis by creating a fracture of AO classification 42A2b, prior to reaming and insertion of an intramedullary nail. A callus was modelled as granulation tissue and gait loads were applied. The model was validated against published data and with sensitivity studies. The effects of weightbearing, fracture gap and angle, percutaneous screws and exchange nailing were compared through quantification of interfragmentary motion and strain, with the latter used to gauge healing performance via mechano-regulation theory. Results. Axial interfragmentary motion increased with increasing weightbearing, however, shear decreased at 25–50% weightbearing, leading to superior healing performance. Fracture gap had minimal effect on axial motion, but larger gaps gave greater shear, compromising healing. Elevated fracture obliquity culminated in more shear and inferior healing. Exchange nailing reduced axial motion by ∼30%, but had little effect on shear. Conversely, percutaneous screws had negligible effect on axial motion, but reduced shear by ∼15%, with three screws having a similar net effect on healing as exchange nailing from 10 to 11mm. Conclusions. This study provides new insight into fracture healing biomechanics and discovered that partial weightbearing, less oblique fractures and percutaneous screws all reduce shear, enhancing healing


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 31 - 31
19 Aug 2024
Polesello GC Ricioli W Gonçalves CI
Full Access

The objective of this study is to evaluate the effectiveness and safety of percutaneous tenotomy of the iliopsoas tendon with the aid of ultrasound in cadavers. An anatomical and descriptive study of the technique of percutaneous tenotomy of the iliopsoas tendon guided by ultrasound and to share our experience in performing it and its reproducibility in clinical practice. Out of 20 tenotomies, 17 were total, performed at the level of the superior border of the acetabulum. Three tenotomies were partial, with more than 75% of the tendon being sectioned in all three. During one of the tenotomies, there was a partial injury to the femoral nerve. Measurements were made of the distance between the site where the blade was inserted and the femoral nerve, a noble structure that would be at greater risk during the procedure, with an average distance of 8.4 millimeters. Ultrasound-guided iliopsoas tendon release procedures have the ability to be performed in a cadaveric model, consistently achieving complete tendon release, except in cases of obesity, with minimal repercussions on adjacent structures, and require approximately 4 minutes to complete


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 190 - 190
1 Mar 2006
Narvani A Tsiridis E Mitchell R Saifuddin A Briggs T Cannon S
Full Access

We compared the accuracy of image guided (ultrasound or CT) percutaneous core needle biopsy to percutaneous core needle biopsy without image guidance in diagnosis of soft tissue tumours. 140 patients with soft tissue lesion who were referred to a London bone and soft tissue tumour unit underwent percutaneous core needle biopsies of their lesion either with or without image guidance.111 of these 140 patients subsequently had surgical excision. The accuracy of image guided percutaneous biopsy and percutaneous biopsy without image was then calculated by comparing the histological results of the needle biopsy to that of the resection. The diagnosis accuracy of unguided biopsy was 78% (36 out of 46) compared to 95% (62 out of 65) in image guided. In 6 out of the 46 patients who had unguided biopsy, there was insufficient material obtained from the needle biopsy to allow histological diagnosis. This was not the case with any of the patients who had image guided core needle biopsy. Using image guidance, either USS or CT scan, improves the diagnostic accuracy of percutaneous core needle biopsy and must be considered in management of patients with soft tissue tumours


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 2 - 2
1 Sep 2021
Hashmi SM Hammoud I Kumar P Eccles J Ansar MN Ray A Ghosh K Golash A
Full Access

Objectives. This presentation discusses the experience at our Centre with treating traumatic thoracolumbar fractures using percutaneous pedicle screw fixation and also looks at clinical and radiological outcomes as well as complications. Design. This is a retrospective study reviewing all cases performed between Jan 2013 and June 2019. Subjects. In our study there were 257 patients in total, of which there were 123 males and 134 females aged between 17 and 70. Methods. We reviewed the case notes and imaging retrospectively to obtain the relevant data. Results. A total of 257 patients were included, 123 males and 134 females; the mean age was 47.6 years. The majority of injuries were from fall from significant height. In 98 cases the fracture involved a thoracic vertebra and in 159 cases a lumbar vertebra. Percutaneous pedicle screw fixation was performed either one level above and below fracture or Two levels above and below the fracture depending upon the level of injury. Forty two cases were treated with additional short pedicle screws at the level of fracture. More than 15% (39) of patients presented with a neurological deficit on admission and more than 80% (32) of those showed post-operative improvement in their neurology as per Frankel Grading system. The mean Operative time was 117minutes +− 45, and mean length of hospital stay was 7.2 +− 3.8 days, with significant improvement in Visual analogue score. Percutaneous fixation achieved a satisfactory improvement in radiological parameters including sagittal Cobb angle (SCA) post-operatively in all patients. The vast majority of patients achieved a good functional outcome according to modified Macnab criteria. Follow up was for a maximum of two years, with relevant imaging at each stage. Ten (3.8%) patients had wound infection with three patients requiring wound debridement. Four patients had upper level screws pulled out and in Four cases one screw was misplaced. All eight had revision surgery. Conclusions. Percutaneous pedicle screw fixation is a safe surgical option with comparable outcomes to open surgery and a potential reduction in perioperative morbidity. Percutaneous pedicle screw fixation is the primary surgical technique to treat traumatic thoracolumbar fractures at our Centre. There were no major complications in our series, with good functional outcome following surgery


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 1 - 1
1 Apr 2022
Jahmani R Alorjan M
Full Access

Introduction. Femoral-shortening osteotomy for the treatment of leg length discrepancy is demanding technique. Many surgical technique and orthopaedic devises have been suggested to perform this procedure. Herein, we describe modified femoral shortening osteotomy over a nail, using a percutaneous multiple drill-hole osteotomy technique. Materials and Methods. We operated on six patients with LLD. Mean femoral shortening was 4.2 cm. Osteotomy was performed using a multiple drill-hole technique, and bone was stabilized using an intramedullary nail. Post-operative clinical and radiological data were reported. Results. Shortening was achieved, with a final LLD of < 1 cm in all patients. All patients considered the lengths of the lower limbs to be equal. No special surgical skills or instrumentation were needed. Intraoperative and post-operative complications were not recorded. Conclusions. Percutaneous femoral-shortening osteotomy over a nail using multiple drill-hole osteotomy technique was effective and safe in treating LLD


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 871 - 878
1 Aug 2024
Pigeolet M Ghufran Syed J Ahmed S Chinoy MA Khan MA

Aims. The gold standard for percutaneous Achilles tendon tenotomy during the Ponseti treatment for idiopathic clubfoot is a tenotomy with a No. 15 blade. This trial aims to establish the technique where the tenotomy is performed with a large-bore needle as noninferior to the gold standard. Methods. We randomized feet from children aged below 36 months with idiopathic clubfoot on a 1:1 basis in either the blade or needle group. Follow-up was conducted at three weeks and three months postoperatively, where dorsiflexion range, Pirani scores, and complications were recorded. The noninferiority margin was set at 4° difference in dorsiflexion range at three months postoperatively. Results. The blade group had more dorsiflexion at both follow-up consultations: 18.36° versus 18.03° (p = 0.115) at three weeks and 18.96° versus 18.26° (p = 0.001) at three months. The difference of the mean at three months 0.7° is well below the noninferiority margin of 4°. There was no significant difference in Pirani scores. The blade group had more extensive scar marks at three months than the needle group (8 vs 2). No major complications were recorded. Conclusion. The needle tenotomy is noninferior to the blade tenotomy for usage in Ponseti treatment for idiopathic clubfoot in children aged below 36 months. Cite this article: Bone Joint J 2024;106-B(8):871–878


Full Access

Hallux valgus surgery can result in moderate to severe post-operative pain requiring the use of narcotic medication. The percutaneous distal metatarsal osteotomy is a minimally invasive approach which offers many advantages including minimal scarring, immediate weight bearing and decreased post-operative pain. The goal of this study is to determine whether the use of narcotics can be eliminated using an approach combining multimodal analgesia, ankle block anesthesia and a minimally invasive surgical approach. Following ethics board approval, a total of 160 ambulatory patients between the ages of 18-70 with BMI ≤ 40 undergoing percutaneous hallux valgus surgery are to be recruited and randomized into Narcotic-free (NF) or Standard (S) groups. To date, 72 patients have been recruited (38 NF and 34 S). The NF group received acetaminophen, naproxen, pregabalin 75mg and 100mg Ralivia (tramadol extended release) before surgery and acetaminophen, naproxen, pregabalin 150mg one dose and Ralivia 100mg BID for five days, as well as a rescue narcotic (hydromorphone, 1mg pills) after surgery. The S group received acetaminophen and naproxen prior to surgery and acetaminophen, naproxen and hydromorphone (1mg pills) post-operatively, our current standard. Visual analog scales (VAS) were used to assess pain and narcotic consumption was recorded at 6, 12, 24, 36, 48, 72 hours and seven days post-operatively. Patients wore a smart watch to record the number of daily steps and sleep hours. A two-sided t-test was used to compare the VAS scores and narcotic consumption. During the first post-operative week, the NF group consumed in total an average of 6.5 pills while the S group consumed in total an average of 16 pills and this difference was statistically significant (p-value=0.001). Importantly, 19 patients (50%) in the NF group and four patients (12%) in the S group did not consume any narcotics post-operatively. For the VAS scores at 24, 48, 72 hours and seven days the NF group's average scores were 2.17, 3.17, 2.92, 2.06 respectively and the S group's average scores were 3.97, 4.2, 3.23, 1.97. There was a statistically significant difference between the groups at 24 and 48hours (the NF group scored lower on the VAS) with a p-value of 0.0008 and 0.04 respectively, but this difference is not considered clinically significant as the minimal clinically important difference reported in the literature is a two-point differential. The NF group walked an average of 1985.75 steps/day and slept an average of 8h01 minute/night, while the S group walked an average of 1898.26 steps/day and slept an average of 8h26 minutes/night in the first post-operative week. Hallux valgus remains a common orthopedic foot problem for which surgical treatment results in moderate to severe post-operative pain. This study demonstrates that with the use of multimodal analgesia, ultrasound guided ankle blocks and a percutaneous surgical technique, narcotic requirements decreased post-operatively. The use of long-acting tramadol further decreased the need for narcotic consumption. Despite decreased use of narcotics, this combined novel approach to hallux valgus surgery allows for early mobilization and excellent pain control


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 5 - 5
23 Apr 2024
Sain B Sidharthan S Naique S
Full Access

Introduction. Treatment of non-union in open tibial fractures Gustilo-Anderson(GA)-3A/3B fractures remains a challenging problem. Most of these can be dealt using treatment methods that requires excision of the non-union followed by bone grafting, masquelet technique, or acute shortening. Circular fixators with closed distraction or bone transport also remains a useful option. However, sometimes due to patient specific factors these cannot be used. Recently antibiotic loaded bone substitutes have been increasingly used for repairing infected non-unions. They provide local antibiotic delivery, fill dead space, and act as a bone conductive implant, which is resorted at the end of a few months. We aimed to assess the outcome of percutaneous injection of bone substitute while treating non-union of complex open tibial fractures. Materials & Methods. Three cases of clinical and radiological stiff tibial non-union requiring further intervention were identified from our major trauma open fracture database. Two GA-3B cases, treated with a circular frame developed fracture-related-infection(FRI) manifesting as local cellulitis, loosened infected wires/pins with raised blood-markers, and one case of GA-3A treated with an intramedullary nail. At the time of removal of metalwork/frame, informed consent was obtained and Cerament-G. TM. (bone-substitute with gentamicin) was percutaneously injected through a small cortical window using a bone biopsy(Jamshedi needle). All patients were allowed to weight bear as tolerated in a well-fitting air-cast boot and using crutches. They were followed up at 6 weekly intervals with clinical assessment of their symptoms and radiographs. Fracture union was assessed using serial radiographs with healing defined as filling of fracture gap, bridging callus and clinical assessment including return to full painless weight bearing. Results. Follow-up at 6 months showed all fractures had healed with no defect or gaps with evidence of new trabecular bone and significant resorption of Cerament-G. TM. at final follow-up. There was no evidence of residual infection with restoration of normal limb function. Fractures with no internal fixation showed a mild deformity that had developed during the course of the healing, presumed due to mild collapse in the absence of fixation. These were less than 10 degrees in sagittal and coronal planes and were clinically felt to be insignificant by the patients. Conclusions. Cerament-G's unique combination of high dose antibiotics and hydroxy apatite matrix provided by calcium sulphate might help provide an osteoconductive environment to allow these stiff non-unions to heal. The matrix appears to provide a scaffold-like structure that allows new bone in-growth with local release of antibiotics helping reduce deep-seated infections. The final deformation at fracture site underlines the need for fixation- and it is very unlikely that this technique will work in mobile nonunions. Whilst similar fractures may heal without the use of bone substitute injections, the speed of healing in presence of significant fracture gap suggests the use of these bone substitutes did help in our cases. Further studies with a larger cohort, including RCTs, to evaluate the effectiveness of this technique compared to other methods are needed


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 20 - 20
4 Jun 2024
Lewis T Robinson PW Ray R Dearden PM Goff TA Watt C Lam P
Full Access

Background. Recent large studies of third-generation minimally invasive hallux valgus surgery (MIS) have demonstrated significant improvement in clinical and radiological outcomes. It remains unknown whether these clinical and radiological outcomes are maintained in the medium to long-term. The aim of this study was to investigate the five-year clinical and radiological outcomes following third-generation MIS hallux valgus surgery. Methods. A retrospective observational single surgeon case series of consecutive patients undergoing primary isolated third-generation percutaneous Chevron and Akin osteotomies (PECA) for hallux valgus with a minimum 60 month clinical and radiographic follow up. Primary outcome was radiographic assessment of the hallux valgus angle (HVA) and intermetatarsal angle (IMA) pre-operatively, 6 months and ≥60 months following PECA. Secondary outcomes included the Manchester-Oxford Foot Questionnaire, patient satisfaction, Euroqol-5D Visual Analogue Scale and Visual Analogue Scale for Pain. Results. Between 2012 and 2014, 126 consecutive feet underwent isolated third-generation PECA. The mean follow up was 68.8±7.3 (range 60–88) months. There was a significant improvement in radiographic deformity correction; IMA improved from 13.0±3.0 to 6.0±2.6, (p < 0.001) and HVA improved from 27.5±7.6 to 7.8±5.1. There was a statistically significant but not clinically relevant increase of 1.2±2.6° in the HVA between 6 month and ≥60 month radiographs. There was an increase in IMA of 0.1±1.6º between 6 month and ≥60 month radiographs which was not statistically or clinically significant. MOXFQ Index score at ≥follow up was 10.1±17.0. The radiographic recurrence rate was 2.6% at final follow up. The screw removal rate was 4.0%. Conclusion. Radiological deformity correction following third-generation PECA is maintained at a mean follow up of 68.8 months with a radiographic recurrence rate of 2.6%. Clinical PROMs and patient satisfaction levels are high and comparable to other third-generation studies with shorter duration of follow up


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1264 - 1270
1 Sep 2015
Karantana A Scammell BE Davis TRC Whynes DK

This study compares the cost-effectiveness of treating dorsally displaced distal radial fractures with a volar locking plate and percutaneous fixation. It was performed from the perspective of the National Health Service (NHS) using data from a single-centre randomised controlled trial. In total 130 patients (18 to 73 years of age) with a dorsally displaced distal radial fracture were randomised to treatment with either a volar locking plate (n = 66) or percutaneous fixation (n = 64). The methodology was according to National Institute for Health and Care Excellence guidance for technology appraisals. . There were no significant differences in quality of life scores between groups at any time point in the study. Both groups returned to baseline one year post-operatively. . NHS costs for the plate group were significantly higher (p < 0.001, 95% confidence interval 497 to 930). For an additional £713, fixation with a volar locking plate offered 0.0178 additional quality-adjusted life years in the year after surgery. The incremental cost-effectiveness ratio (ICER) for plate fixation relative to percutaneous fixation at list price was £40 068. When adjusting the prices of the implants for a 20% hospital discount, the ICER was £31 898. Patients who underwent plate fixation did not return to work earlier. We found no evidence to support the cost-effectiveness, from the perspective of the NHS, of fixation using a volar locking plate over percutaneous fixation for the operative treatment of a dorsally displaced radial fracture. Cite this article: Bone Joint J 2015;97-B:1264–70


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 66 - 66
14 Nov 2024
Tirta M Hjorth MH Jepsen JF Kold S Rahbek O
Full Access

Introduction. Epiphysiodesis, defined as the process of closing the growth plate (physis), have been used for several years as a treatment option of cases where the predicted leg-length discrepancy (LLD) falls between 2 to 5 cm. The aim of this study was to systematically review the existing literature on the effectiveness of three different epiphysiodesis techniques with implant usage for the treatment of leg-length discrepancy in the pediatric population. The secondary aim was to address the reported complications of staples, tension-band plates (TBP) and percutaneous epiphysiodesis screws (PETS). Method. This systematic review was performed according to PRISMA guidelines. We searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with epiphysiodesis with an implant. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre/post-operatively, successful/unsuccessful) and complications that were graded on severity. Result. Forty-four studies (2184 patients) were included, from whom 578 underwent TBP, 455 PETS and 1048 staples. From pooled analysis of the studies reporting success rate, 64% (150/234) successful TBP surgeries (10 studies), 78% (222/284) successful PETS (9 studies) and 52% (212/407) successful Blount staples (8 studies). Severe complications rate was 7% for PETS, 17% for TBP and 16% for Blount staples. TBP had 43 cases of angular deformity (10%), Blount staples 184 (17%) while PETS only 18 cases (4%). Conclusion. Our results highlighted that PETS seems to be the most successful type of epiphysiodesis surgery with an implant, with higher success rate and lower severe complications than TBP or Blount staples


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 365 - 373
1 Mar 2016
Lucas y Hernandez J Golanó† P Roshan-Zamir S Darcel V Chauveaux D Laffenêtre O

Aims. The aim of this study was to report a single surgeon series of consecutive patients with moderate hallux valgus managed with a percutaneous extra-articular reverse-L chevron (PERC) osteotomy. . Patients and Methods. A total of 38 patients underwent 45 procedures. There were 35 women and three men. The mean age of the patients was 48 years (17 to 69). An additional percutaneous Akin osteotomy was performed in 37 feet and percutaneous lateral capsular release was performed in 22 feet. Clinical and radiological assessments included the type of forefoot, range of movement, the American Orthopedic Foot and Ankle (AOFAS) score, a subjective rating and radiological parameters. . The mean follow-up was 59.1 months (45.9 to 75.2). No patients were lost to follow-up. Results. The mean AOFAS score increased from 62.5 (30 to 80) pre-operatively to 97.1 (75 to 100) post-operatively. A total of 37 patients (97%) were satisfied. At the last follow up there was a statistically significant decrease in the hallux valgus angle, the intermetatarsal angle and the proximal articular set angle. The range of movement of the first metatarsophalangeal joint improved significantly.. There was more improvement in the range of movement in patients who had fixation of the osteotomy of the proximal phalanx. Conclusion. Preliminary results of this percutaneous approach are promising. This technique is reliable and reproducible. Its main asset is that it maintains an excellent range of movement. Take home message: The PERC osteotomy procedure is an effective approach for surgical management of moderate hallux valgus which combines the benefits of percutaneous surgery with the versatility of the chevron osteotomy whilst maintaining excellent first MTPJ range of motion. Cite this article: Bone Joint J 2016;98-B:365–73


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1502 - 1507
1 Nov 2006
Lauge-Pedersen H Hägglund G Johnsson R

Percutaneous physiodesis is an established technique for treating mild leg-length discrepancy and problems of expected extreme height. Angular deformities resulting from incomplete physeal arrest have been reported, and little is known about the time interval from percutaneous physiodesis to actual physeal arrest. This procedure was carried out in ten children, six with leg-length discrepancy and four with expected extreme height. Radiostereometric analysis was used to determine the three-dimensional dynamics of growth retardation. Errors of measurement of translation were less than 0.05 mm and of rotation less than 0.06°. Physeal arrest was obtained in all but one child within 12 weeks after physiodesis and no clinically-relevant angular deformities occurred. This is a suitable method for following up patients after percutaneous physiodesis. Incomplete physeal arrest can be detected at an early stage and the procedure repeated before corrective osteotomy is required


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 57 - 57
4 Apr 2023
Tariq M Uddin Q Amin H Ahmed B
Full Access

This study aims to compare the outcomes of Volar locking plating (VLP) versus percutaneous Kirschner wires (K-wire) fixation for surgical management of distal radius fractures. We systematically searched multiple databases, including MEDLINE for randomized controlled trials (RCTs) comparing outcomes of VLP fixation and K-wire for treatment of distal radius fracture in adults. The methodological quality of each study was assessed by the Cochrane Risk of Bias tool. Patient-reported outcomes, functional outcomes, and complications at 1 year follow up were evaluated. Meta-analysis was performed using random-effects models and results presented as risk ratios (RRs) or mean differences (MDs) with 95% confidence interval (CI). 13 RCTs with 1336 participants met the inclusion criteria. Disabilities of the Arm, Shoulder and Hand (DASH) scores were significantly better for VLP fixation (MD= 2.15; 95% CI, 0.56-3.74; P = 0.01; I2=23%). No significant difference between the two procedures for grip strength measured in kilograms (MD= −3.84; 95% CI,-8.42-0.74; P = 0.10; I2=52%) and Patient-Rated Wrist Evaluation (PRWE) scores (MD= −0.06; 95% CI,-0.87-0.75; P = 0.89; I2=0%). K-wire treatment yielded significantly improved extension (MD= −4.30; P=0.04) but with no differences in flexion, pronation, supination, and radial deviation (P >0.05). The risk of complications and rate of reoperation were similar for the two procedures (P >0.05). This meta-analysis suggests that VLP fixation improves DASH score at 12 months follow up, however, the difference is small and unlikely to be clinically important. Existing literature does not provide sufficient evidence to demonstrate the superiority of either VLP or K-wire treatment in terms of patient-reported outcomes, functional outcomes, and complications