We compared the postoperative wound discharge rates and 3 months clinical results of three types of wound closure and dressing – 2-octylcyanoacrylate with Opstie (G+O), 2-octylcyanoacrylate with Tegaderm (G+T), and Opsite without 2-octylcyanoacrylate (O) in patients having
When performing total hip replacements in patients with hip dysplasia, acetabular augmentation may be required to prevent early component failure. Preoperative radiographic templating may help estimate acetabularcomponent coverage but has not previously been shown to predict the need for augmentation. We developed a simple method to estimate the percentage of acetabular component coverage from pre-operative radiographs (True: False cup ratio). We aimed to evaluate whether this couldpredict the need foracetabular augmentation at
Intraoperative fractures although rare are one of the complications known to occur while performing a total hip arthroplasty (THA). However, due to lower incidence rates there is currently a gap in this area of literature that systematically reviews this important issue of complications associated with THA. Method: We looked into Electronic databases including PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), the archives of meetings of orthopaedic associations and the bibliographies of included articles and asked experts to identify prospective studies, published in any language that evaluated intra-operative fractures occurring during total hip arthroplasty from the year 1950-2020. The screening, data extraction and quality assessment were carried out by two researchers and if there was any discrepancy, a third reviewer was involved. Fourteen studies were identified. The reported range of occurrence of fracture while performing hip replacement surgery was found to be 0.4-7.6%. Major risk factors identified were surgical approaches, Elderly age, less Metaphyseal-Diaphyseal Index score, change in resistance while insertion of the femur implants, inexperienced surgeons, uncemented femoral components, use of monoblock elliptical components, implantation of the acetabular components, patients with ankylosing spondylitis, female gender, uncemented stems in patients with abnormal proximal femoral anatomy and with cortices, different stem designs, heterogeneous fracture patterns and toothed design. Intraoperative fractures during THA were managed with cerclage wire, femoral revision, intramedullary nail and cerclage wires, use of internal fixation plates and screws for management of intra operative femur and acetabular fractures. The main reason for intraoperative fracture was found to be usage of cementless implants but planning and timely recognition of risk factors and evaluating them is important in management of intraoperative fractures. Adequate surgical site exposure is critical especially during dislocation of hip, reaming of acetabulum, impaction of implant and preparing the femoral canal for stem insertion. Eccentric and increased reaming of acetabulum to accommodate a larger cup is to be avoided, especially in females and elderly patients as the acetabulum is thinner. However, this area requires more research in order to obtain more evidence on effectiveness, safety and management of intraoperative fractures during THA.
Restoration of anatomy is paramount in total hip arthroplasty (THA) to optimise function and stability. Leg-length discrepancy of ≥10mm is poorly tolerated and can be the subject of litigation. We routinely use a multimodal protocol to optimise soft tissue balancing which involves pre-operative templating, leg-length measurement supine and in the lateral position after positioning, and the use of an intra-operative leg-length measurement device to ensure optimisation of leg-length. We have analysed the results of our protocol in restoring leg-length in
This study aims to define the normal postoperative presepsin kinetics in patients undergoing primary cementless total hip replacement (THR). Patients undergoing primary cementless THR at our Institute were recruited. At enrollment anthropometric data, smocking status, osteoarthritis stage according to Kellgren and Lawrence, Harris Hip Score (HHS), drugs assumption and comorbidities were recorded. All the patients underwent serial blood tests, including complete blood count, presepsin (PS) and C-Reactive Protein (CRP) 24 hours before arthroplasty and at 24-, 48-, 72- and 96-hours postoperatively and at 3-, 6- and 12-months follow-up. Statistical analysis was performed with SPSS v25.0 (SPSS Inc, Chicago, IL, USA). The Wilcoxon and Kruskal-Wallis tests followed by the Dunn multiple comparison post hoc tests were carried out. Correlations between PS, CRP and TOT were assessed using the Spearman rank correlation coefficient. P values below 0.05 were considered significant.Aim
Methods
Total hip replacement (THR) is one of the most successful and cost-effective interventions in orthopaedic surgery. Dislocation is a debilitating complication of THR and managing an unstable THR constitutes a significant clinical challenge. Stability in THR is multifactorial and is influenced by surgical, patient and implant related factors. It is established that larger diameter femoral heads have a wider impingement-free range of movement and an increase in jump distance, both of which are relevant in reducing the risk of dislocation. However, they can generate higher frictional torque which has led to concerns related to increased wear and loosening. Furthermore, the potential for taper corrosion or trunnionosis is also a potential concern with larger femoral heads, particularly those made from cobalt-chrome. These concerns have meant there is hesitancy among surgeons to use larger sized heads. This study presents the comparison of clinical outcomes for different head sizes (28mm, 32mm and 36mm) in primary THR for 10,104 hips in a single centre. A retrospective study of all consecutive patients who underwent primary THR at our institution between 1st April 2003 and 31st Dec 2019 was undertaken. Institutional approval for this study was obtained. Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analysis was used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, gender, primary diagnosis, ASA score, articulation type, and fixation method.Abstract
Objectives
Methods
The thickness of the cement mantle surrounding total hip replacements has been used to predict the incidence of aseptic loosening. However little work has been done regarding the significance of the cement mantle distal to the tip of the femoral prosthesis. Results are reported of a radiographic audit study analyzing the thickness of the distal cement column in
Accurate orientation of the acetabular component during a total hip replacement is critical for optimising patient function, increasing the longevity of components, and reducing the risk of complications. This study aimed to determine the validity of a novel VR platform (AescularVR) in assessing acetabular component orientation in a simulated model used in surgical training. The AescularVR platform was developed using the HTC Vive® VR system hardware, including wireless trackers attached to the surgical instruments and pelvic sawbone. Following calibration, data on the relative position of both trackers are used to determine the acetabular cup orientation (version and inclination). The acetabular cup was manually implanted across a range of orientations representative of those expected intra-operatively. Simultaneous readings from the Vicon® optical motion capture system were used as the ‘gold standard’ for comparison. Correlation and agreement between these two methods was determined using Bland-Altman plots, Pearson's correlation co-efficient, and linear regression modelling.Abstract
Objectives
Methods
This was a retrospective study of registry data from a National Orthopaedic Hospital for all THRs with 10-year follow-up data. Inclusion criteria were all THRs with a minimum of 10-year follow-up data. All metal-on-metal (MoM) THRs and MoM resurfacings were excluded from the analysis due to the high rate of revision associated with these bearings. Univariate and multivariate analyses controlling for confounding variables were performed to compare outcomes. A total of 1,697 THRs were performed in 1,553 patients. The four significant predictors for revision were fixation type (p<0.01), surface bearing type (p<0.01), age (P<0.05) and head size (p<0.05). Gender, BMI and approach had no effect on revision rates. The lowest 10-year all-cause revision rates were seen in cemented THRs at 1.7%. Ceramic-on-poly bearings had the lowest revision rate at only 1.2%. Metal-on-poly bearings had a 1.7% revision rate. Ceramic on ceramic bearings had a 7.1% revision rate with 1 revision for squeak and 1 revision for ceramic head fracture. The causes for revision in order of decreasing frequency were as follows: Infection (n=13, 0.7%), dislocation (n=7, 0.4%), periprosthetic fracture (n=3, 0.2%) and aseptic loosening (n=2, 0.1%). There were 2 re-revisions at 10 years in total. The smaller 22.225mm head sizes had a significantly lower revision rate than other head sizes (p<0.05). Ceramic-on-poly bearings, cemented fixation and smaller head sizes perform better in the experience of this registry. However, with multivariate analysis, these differences were shown to be insignificant.
We undertook a retrospective cohort study to determine if body mass index (BMI) is an independent factor in determining patient outcome following total hip replacement (THR). Outcomes were determined using the Oxford Hip Score, a questionnaire designed to evaluate self-reported function and pain levels in people with hip pain. We looked at all THRs carried out on patients with a BMI of ≥30 over a 38 month period (220 operations) and compared these with 220 randomly selected THRs carried out on patients with a BMI of <30 within the same 38 month period. For each case we recorded patient BMI, P score and Oxford scores. We calculated the difference between pre-operative and one-year post-operative Oxford hip scores. We used Kendall's rank correlation to assess any potential correlation between BMI and functional change, and the Mann-Whitney U test to establish if functional change between the groups was statistically significant. Our study indicates that BMI is not an independent factor in determining relative subjective functional change following THR. Although it showed that patients with a BMI of ≥30 have worse function both before and after THR, there was no statistically significant difference between the two groups in terms of functional change. We therefore suggest that patients with a higher BMI be considered candidates for THR as they can expect the same degree of functional improvement. Given the trend for increasing numbers of obese patients in the population these findings could have a significant impact on the future of THR operations.
The position of the hip-joint centre of rotation (HJC) within the pelvis is known to influence functional outcome of total hip replacement (THR). Superior, lateral and posterior relocations of the HJC from anatomical position have been shown to be associated with greater joint reaction forces and a higher incidence of aseptic loosening. In biomechanical models, the maximum force, moment-generating capacity and the range of motion of the major hip muscle groups have been shown to be sensitive to HJC displacement. This clinical study investigated the effect of HJC displacement and acetabular cup inclination angle on functional performance in patients undergoing primary THR. Retrospective study of primary THR patients at the RNOH. HJC displacement from anatomical position in horizontal and vertical planes was measured relative to radiological landmarks using post-operative, calibrated, anterior-posterior pelvic radiographs. Acetabular cup inclination angle was measured relative to the inter-teardrop line. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.Background
Methods
It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome. Retrospective study of primary THR patients at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model. 90 THRs were studied in 87 patients (55 Female). Mean age at THR=62 (22-86). Mean follow-up=17 months (11-39 months). Median OHS=16, WOMAC=8. Coronal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05). Sagittal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05).Methods
Results
This study aimed to quantify self-reported outcomes and walking gait biomechanics in patients following primary and revision THA. The specific goals of this study were to investigate: (i) if primary and revision THA patients have comparable preoperative outcomes; and (2) if revision THA patients have worse postoperative outcomes than
Dislocation post THA confers a higher risk of re-dislocation (Kotwal et al, 2009). The dual mobility (DM) cup design (1974) was aimed at improving the stability by increasing the femoral head to neck ratio (Cuthbert et al., 2019) combining the ideas of low friction arthroplasty with increased jump distance associated with a big head arthroplasty. Understand the dislocation rates, rates of aseptic loosening, infection rate and revision rates between the 2 types of constructs to provide current and up-to date evidence. Medline, pubmed, embase and Cochrane databases were used based on PRISMA guidelines. RevMan software was used for the meta-analysis. Studies (English literature) which used DM construct with atleast 6 months follow-up used as intervention and non DM construct as control were included. 2 independent reviewers conducted the review with a third reviewer in case of difference in opinion regarding eligibility. Primary outcome was dislocation rate and secondary outcome was rate of revision. 564 articles identified out of which 44 articles were screened for full texts and eventually 4 systematic review articles found eligible for the study. Thus, study became a review of systematic reviews. From the 4 systematic reviews, another 35 studies were identified for data extraction and 13 papers were used for meta-analysis. Systematic reviews evaluated, projected an average follow up of 6-8 years with significantly lower dislocation rates for DM cups. The total number of patients undergoing DM cup
Abstract. Introduction. Dislocation post THA confers a higher risk of re-dislocation (Kotwal et al, 2009). The dual mobility (DM) cup design (1974) was aimed at improving the stability by increasing the femoral head to neck ratio (Cuthbert et al., 2019) combining the ideas of low friction arthroplasty with increased jump distance associated with a big head arthroplasty. Aims. Understand the dislocation rates, rates of aseptic loosening, infection rate and revision rates between the 2 types of constructs to provide current and up-to date evidence. Methods. Medline, pubmed, embase and Cochrane databases were used based on PRISMA guidelines. RevMan software was used for the meta-analysis. Studies (English literature) which used DM construct with atleast 6 months follow-up used as intervention and non DM construct as control were included. 2 independent reviewers conducted the review with a third reviewer in case of difference in opinion regarding eligibility. Primary outcome was dislocation rate and secondary outcome was rate of revision. Results. 564 articles identified out of which 44 articles were screened for full texts and eventually 4 systematic review articles found eligible for the study. Thus, study became a review of systematic reviews. From the 4 systematic reviews, another 35 studies were identified for data extraction and 13 papers were used for meta-analysis. Systematic reviews evaluated, projected an average follow up of 6–8 years with significantly lower dislocation rates for DM cups. The total number of patients undergoing DM cup
Total joint replacement (TJR) was one of the most revolutionary breakthroughs in joint surgery. The majority studies had shown that most implants could last about 25 years, anyway, there is still variation in the longevity of implants. In US, for all the hip revisions from 2012 to 2017 in the United States, 12.0% of the patients were diagnosed as aseptic loosening. Variable studies have showed that any factor that could cause a systemic or partial bone loss, might be the risk of periprosthetic osteolysis and aseptic loosening. Breast cancer is the most frequent malignancy in women, more than 2.1 million women were newly diagnosed with breast cancer, 626,679 women with breast cancer died in 2018. It's been reported that the mean incidence of THA was 0.29% for medicare population with breast cancer in USA, of which the incidence was 3.46% in Norwegian. However, the effects of breast cancer chemotherapy and hormonotherapy, such as aromatase inhibitors (AI), significantly increased the risk of osteoporosis, and had been proved to become a great threat to hip implants survival. In this case, a 46-year-old female undertook chemotherapy and hormonotherapy of breast cancer 3 years after her
Introduction. A recent study to identify clinically meaningful benchmarks for gait improvement after total hip replacement (THA) has shown that the minimum clinically important improvement (MCII) in gait speed after THA is 0.32 m/sec. Currently, it remains to be investigated what preoperative factors link to suboptimal recovery of gait function after THA. This study aimed to identify preoperative lower-limb muscle predictors for gait speed improvement after THA for hip osteoarthritis. Method. This study enrolled 58 patients who underwent unilateral
Introduction. Cephalomedullary nailing (CMN) is commonly used for unstable pertrochanteric fracture. CMN is relatively safe method although various complications can potentially occur needing revision surgery. Commonly used salvage procedures such as renailing, hemiarthroplasty, conservative treatment or total hip arthroplasty (THA) are viable alternatives. The aim was to investigate the rate of THA after CMN and evaluate the performance on conversion total hip arthroplasty (cTHA) after failure of CMN. Method. Collected data included patients from two orthopedic centers. Data consisted of all cTHAs after CMN between 2014-2020 and primary cementless THA operations between 2013-2023.
Abstract. Objective. Short-stem total hip arthroplasty (THA) aims to preserve the proximal bone stock for future revisions, so that the first revision should resemble a primary intervention rather than a revision. This study aimed to compare the clinical and radiological outcomes in revision THA after failed short stem versus after failed conventional stem THA. Methods. This study included forty-five patients with revision THA divided into three groups (15 each); group A: revision after short stem, group B: revision after conventional cementless stem and group C revision after conventional cemented stem. The studied groups were compared regarding 31 variables including demographic data, details of the primary and revision procedures, postoperative radiological subsidence, hospital stay, time for full weight bearing (FWB), preoperative and postoperative clinical scores. Results. Early stem subsidence (40%) was the main indication of revision in group A compared to peri-prosthetic femoral fractures (PFFs) (73.3%) and aseptic loosening (53.3%) in group B and C respectively (P=0.021). The mean time to revision was significantly shorter in group A (15 months) compared to 95.33 and 189.40 months in group B and C respectively. (P=0.005). Sixty % (9 patients) in group A were revised in the first year. The mean operative time, blood loss, postoperative blood transfusion and hospital stay were significantly lower in group A compared to group B and C (P<0.001, <0.001, 0.002 and 0.001 respectively). Revisions in group A were performed using either short stems (13.3%) or conventional stems (86.7%) whilst 80% of patients needed long stems and 20% of patients needed conventional stems in group B and C (P<0.001). The mean postoperative Harris Hip Score (HHS) at the latest follow up was 87.07, 87.53 and 85.47 in group A, B and C respectively. All PFFS had excellent results according to Beal's and Tower's criteria; all fractures healed and the implants were stable. Conclusion. The most common cause of failure of short stems is early stem subsidence. Short stem THA has specific indications and patient selection is very crucial. Preoperative templating for short stems and a detailed analysis of the individual patient anatomy in anteroposterior and lateral views are mandatory to predict the correct implant size more accurately. The use of intraoperative imaging can verify the sizing, implant position, and sufficient contact with the lateral cortex. Revision of short stem THA resembled the