Advertisement for orthosearch.org.uk
Results 1 - 20 of 27
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 18 - 18
1 Nov 2019
Ghosh A Best AJ Rudge SJ Chatterji U
Full Access

Venous thromboembolism (VTE) is a serious complication after total hip and knee arthroplasty. There is still no consensus regarding the best mode of thromboprophylaxis after lower limb arthroplasty. The aim of this study was to ascertain the efficacy, safety profile and rate of adverse thromboembolic events of aspirin as extended out of hospital pharmacological anticoagulation for elective primary total hip and knee arthroplasty patients and whether these rates were comparable with published data for low molecular weight heparin (LMWH). Data was extracted from a prospective hospital acquired thromboembolism (HAT) database. The period of study was from 1st Jan 2013-31st Dec 2016 and a total of 6078 patients were treated with aspirin as extended thromboprophylaxis after primary total hip and knee arthroplasty. The primary outcome measure of deep vein thrombosis and pulmonary embolism within 90 days postoperatively was 1.11%. The secondary outcome rates of wound infection, bleeding complications, readmission rate and mortality were comparable to published results after LMWH use. The results of this study clearly show that Aspirin, as part of a multimodal thromboprophylactic regime, is an effective and safe regime in preventing VTE with respect to risk of DVT or PE when compared to LMWH. It is a cheaper alternative to LMWH and has associated potential cost savings


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 24 - 24
1 Jan 2022
Shaeir M Raad M Graham S Shrivastava R
Full Access

Abstract

Background

Blood transfusion requirement after primary total hip replacements (THR) and total knee replacements (TKR) was found to be related to increased post-operative complications rate and length of hospital stay. Pre-operative haemoglobin level remains the single most important factor determining the requirement for post-operative blood transfusion.

Methods

We carried out a local retrospective audit of 977 THRs and TKRs in 2019. Pre-operative and pre-transfusion haemoglobin levels for transfused group of patients were recorded.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 8 - 8
1 Mar 2017
Barnes L Menendez M Lu N Huybrechts K Ring D Ladha K Bateman B
Full Access

Background

There is growing clinical and policy emphasis on minimizing transfusion use in elective joint arthroplasty, but little is known about the degree to which transfusion rates vary across US hospitals. This study aimed to assess hospital-level variation in use of allogeneic blood transfusion in patients undergoing elective joint arthroplasty, and to characterize the extent to which variability is attributable to differences in patient and hospital characteristics.

Methods

The study population included 228,316 patients undergoing total knee arthroplasty (TKA) at 922 hospitals and 88,081 patients undergoing total hip arthroplasty (THA) at 606 hospitals from January 1, 2009, to December 31, 2011, in the Nationwide Inpatient Sample database, a 20% stratified sample of US community hospitals.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 62 - 62
1 Aug 2020
Kooner S Kubik J Mahdavi S Khong H Batuyong E Sharma R
Full Access

Given the high prevalence of psychiatric illness in the total joint arthroplasty (TJA) population, relatively little is known about how these two conditions affect each other. Therefore, the purpose of this study is to evaluate the role of major psychiatric illness on patient specific outcomes after TJA. We hypothesize that patients with major psychiatric illnesses will report inferior outcomes and have more complications after TJA compared to those without any psychiatric illness.

We matched and compared two cohorts of patients undergoing TJA from a prospectively collected database registry, which included those with and without a major psychiatric disorder. Major psychiatric disorder was identified in the registry database by determining if patients had been formally diagnosed with any of the following conditions: bipolar disorder, major personality disorder, chronic mental health diagnoses, depression, or schizophrenia. Primary outcomes of interest included patient specific outcomes measured using the WOMAC or EQ5D. Secondary outcomes included complications, infections, hospital length of stay, 30-day readmission rates and final discharge destination.

In total we included 1828 TJAs (1000 THAs, 828 TKAs). In terms of the primary outcome, both the THA experimental group (37.80 ± 17.91 vs. 40.74 ± 19.3, p=0.023) and TKA experimental group (43.38 ± 18.41 vs 45.45 ± 20.07, p=0.050) had significantly lower preoperative WOMAC scores compared to their respective control groups. At the 3-month period both the THA experimental group (76.74 ± 16.94 vs. 79.16 ± 16.19, p=0.036) and TKA experimental group (71.09 ± 18.64 vs. 75.92 ± 16.22, p=0) again had significantly lower 3-month postoperative WOMAC score. Clinical outcomes at the 1-year mark were similar for both groups in terms of WOMAC and EQ5D. Patients with psychiatric illness were more likely to have increased LOS and non-routine discharge from hospital. In the THA subset, the experimental group had an increased LOS by 1.43 days (p=0.0028), in the TKA subset, the experimental group had an increased LOS by 0.77 days (p= 0.050). In terms of non-routine discharge, the THA experimental group was discharged home 86.9% of the time compared to the control group at 91.8% (p=0.024). In the TKA subset, the experimental group was discharged home 87.6% of the time compared to the control group at 92% (p=0.022). There were no other differences between the two subsets in regards to transfusions, 30-day readmissions, infections, mechanical adverse events, and medical complications.

In conclusion, our results demonstrate that psychiatric illness can result in worse outcomes in the early perioperative period after TJA, although outcomes are equivalent 1 year postoperatively. Patients with psychiatric illness can be expected to gain significant improvements in outcome after surgery that are comparable to a baseline population without psychiatric illness. Nonetheless, patients with psychiatric illness are at increased risk of delayed discharge and non-routine discharge. As such, they may require personalized care post-operatively, and should be counseled accordingly. Based on our results, psychiatric illness should not be an impediment to proceeding with TJA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 54 - 54
1 Dec 2013
Szubski C Farias-Kovac M Hebeish M Klika A Mishra K Barsoum W
Full Access

Introduction:

The prevalence of total hip (THA) and knee arthroplasty (TKA) is growing dramatically, with more than 1 million procedures performed annually in the United States. As the cost of and demand for the newest orthopaedic implants continue to rise, the price paid to medical device companies for implants is a growing concern. Some high-volume healthcare institutions have adopted price capitation strategies to control costs, in which a flat purchase price is negotiated for all implant line items regardless of technology and material. The purpose of this study was to evaluate whether the implementation of price capitation in a large health system affected trends in THA and TKA premium implant selection by surgeons. A secondary objective was to compare selection trends between surgeons with an academic center affiliation and community practice surgeons, within a single health system.

Methods:

All consecutive primary THA and TKA cases six months before (1/1/2011–6/30/2011) and after (8/1/2011–1/31/2012) implementation of a capitated pricing strategy (7/1/2011) were identified. Surgeon education regarding the new pricing policy was conducted for 1-month following implementation, and data during this time were omitted from the study. After exclusions (Figure 1), a total of 481 THA and 674 TKA from the large hospital, and 253 THA and 315 TKA from the two community hospitals comprised the final study cohort. A retrospective review of patient demographics and implant characteristics for each case was performed. Premium THA implants were defined by the existence of one of the following bearing surfaces: second (2G) or third generation (3G) highly cross-linked polyethylene liner with a ceramic or oxidized-zirconium femoral head, ceramic liner with a ceramic femoral head, or mobile-bearing system. Premium TKA implants were defined by the existence of at least one of the following criterion: mobile-bearing design, high-flexion design, oxidized-zirconium femoral component, and/or highly cross-linked polyethylene bearing surface. Pearson's chi-square analyses and Fisher's exact test were used to compare implant usage between pre- and post-capitated pricing time periods.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 87 - 87
1 Feb 2012
Patel R Stygall J Harrington J Newman S Haddad F
Full Access

We aimed to measure cerebral microemboli load during total hip [THA] and knee arthroplasty (TKA) using transcranial Doppler ultrasound (TCD) and to investigate whether cerebral embolic load influences neuropsychiatric outcome. The timing of the microemboli was also related to certain surgical activities to determine if a specific relationship exists and the presence of a patent foramen ovale was investigated.

Patients undergoing primary THA and TKA underwent a battery of ten neuropsychiatric tests pre-operatively and at 6 weeks and 6 months post-operatively. Microembolic load was recorded using TCD onto VHS tape for subsequent analysis. Patent foramen ovale detection was performed using bolus intravenous injection of agitated saline followed by valsalva manoeuvre. The timing of specific surgical steps was recorded for each operation and embolic load calculated for that period. All patients were assessed for quality of life and orthopaedic outcome measures.

Results

45 THA patients and 50 TKA patients were studied. Cerebral microembolisation occurred in 35% of all patients (10 THA patients and 19 TKA patients). Mean microembolic load was 2.8 per patient for THA and 3.76 per patient for TKA patients. PFO was detected in 29 patients overall. Insertion of the femoral component and deflation of the tourniquet were associated with a larger microembolic loads. Neuropsychiatric outcome was not affected by the low embolic loads. Quality of life and Orthopaedic outcome at 6 months was good.

Conclusion

Cerebral microembolisation occurs in a significant proportion of patients during total hip and knee arthroplasty. The presence of a patent foramen ovale does not appear to influence the incidence of microembolisation or load. Specific surgical activities are associated with generating greater embolic loads and methods of avoiding these emboli such as venting the femur may minimise complications and optimise outcomes. Neuropsychiatric outcomes do not seem to be affected by microembolisation of the brain during total joint arthroplasty.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 42 - 42
1 Dec 2021
Chisari E D'Mello D Parvizi J
Full Access

Aim. A large body of evidence is emerging to implicate that dysregulation of the gut microbiome (dysbiosis) increases the risk of surgical site infections. Gut dysbiosis is known to occur in patients with inflammatory bowel disease (IBD), allowing for translocation of bacteria across the inflamed and highly permeable intestinal mucosal wall. The null hypothesis was that IBD was not associated with increased risk of periprosthetic joint infection (PJI) after primary total hip and knee arthroplasty. Our aim was to investigate whether a prior diagnosis of IBD was associated with a higher risk of PJI following primary total hip and knee arthroplasty. Method. A matched cohort study was designed. Primary endpoint was the occurrence of PJI at 2-year. Secondary endpoints were aseptic revisions, as well as discharge to rehab facility, complications up to 30 days, and readmission up to 90 days after TJA. ICD-9 and −10 codes were used to identify patients with IBD and the control cohort. A chart review was performed to confirm diagnosis of IBD. Using our institutional database, 154 patients with IBD were identified and matched (3 to 1) for age, sex, body mass index (BMI), year of surgery, and joint affected with 462 individuals without IBD undergoing TJA. Results. The cumulative incidence of PJI was 4.55% among patients with IBD versus 1.32% among the control cohort (p=0.024). When bivariate logistic regression was performed, a diagnosis of IBD was found to be an independent risk factor for PJI (OR 3.56 95% C.I. 1.17 – 11.23; p=0.024) and aseptic revisions (OR 3.47, 95% C.I. 1.30 – 3.47; p=0.012). The rate of postoperative complications was also higher in patients with IBD. Conclusions. Based on the findings of this study, it appears that patients with IBD are at higher risk for failure due to PJI or aseptic loosening after TJA. The exact reason for this finding is not known but could be related to the bacterial translocation from the inflamed intestinal mucosa, the dysregulated inflammatory status of these patients, malnutrition, and potentially other factors. Some of the so-called aseptic failures maybe also as a result of infection that may have escaped detection and/or recognition


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 42 - 42
1 Oct 2022
Goosen J Weegen WVD Rijnen W Eck JV Liu W
Full Access

Aim. To date, the value of culture results after a debridement, antibiotics and implant retention (DAIR) for early (suspected) prosthetic joint infection (PJI) as risk indicators in terms of prosthesis retention is not clear. At one year follow-up, the relative risk of prosthesis removal was determined for culture-positive and culture-negative DAIRs after primary total hip or knee arthroplasty. The secondary aim was to explore differences in patient characteristics, infection characteristics and outcomes between these two groups. Methods. A retrospective regional registry study was performed in a group of 359 patients (positive cultures: n = 299, negative cultures n = 60) undergoing DAIR for high suspicion of early PJI in the period from 2014 to 2019. Differences in patient characteristics, deceased patients and number of subsequent DAIRs between the positive and negative DAIR groups were analyzed using independent t-tests, Mann-Whitney, Pearson's Chi-square tests and Fisher's Exact tests. Results. Overall implant survival rate following DAIR was 89%. The relative risk for prosthesis removal was 7.4 times higher (95% confidence interval (CI) 1.0–53.1) in the positive DAIR group (37/299, 12.4%) compared to the negative DAIR group (1/60, 1.7%). The positive group had a higher body mass index (p = 0.034), rate of wound leakage of >10 days (p = 0.016) and more subsequent DAIRs (p = 0.006). Conclusion. Since implant survival results after DAIR are favorable, the threshold to perform a DAIR procedure in early PJI should be low in order to retain the prosthesis. A DAIR procedure in case of negative cultures does not seem to have unfavorable results in terms of prosthesis retention


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 37 - 37
1 Apr 2019
Meftah M Kirschenbaum I
Full Access

Background. We identified several opportunities to significantly reduce cost for hip and knee arthroplasty procedures:. Customized instruments: by identifying the essential instruments for arthroplasty cases, we managed to have one universal tray for each case, and 3 specific trays from the implant manufacturing company. Customized wrap-free, color-coded, stackable trays: by using a wrap-free trays, preparation time in central sterile, opening tray time in OR and turn-over time were reduced. Also, stackable trays were organized based on side and size, therefore only 2 trays needed to be used in each case. Discounted implants: negotiated through optional case coverage with revision system and reps available as backup. Optional rep coverage protocols: designed through process management of the operating room surgical staff and central sterile. Aim of the study was to measure the cost savings, efficacy, and outcomes associated with primary total hip and knee arthroplasty by implementing these protocol. Methods. This is a prospective study from January to October 2016 for selected primary total hip and knee arthroplasties were performed with the above protocols by 2 experienced arthroplasty trained surgeons, were followed for minimum 3 months. Initiating the cost saving protocols were achieved by re-engineering customized trays, discounted implants through optional case coverage (Sourced Based Selection of a Cooperating Manufacturer, MTD), and focused on process management of the staff training. Staff responsibilities were divided into 2 categories:. Familiarity of the instruments, implant, and techniques; trays set up and assurance of availability of the implants. These responsibilities were covered by a trained OR technician and the surgeon. Final verification of the accurate implants prior to opening the packaging. This was achieved by a trained OR nurse and the surgeon. Results. We did not have any intra-operative complications. We also did not encounter any issued with the trays or errors in opening of the implants. There were no re-admissions, fracture, dislocation, or infection. The mean length of stay was 2.2 ± 0.5 days (range 1–3 days) with 68% home discharges. The cost of the implant was reduced from $4,800 to $1,895 with $2,905 cost saving per case and total savings of $58,100. The projected savings only for uncomplicated primary total hip arthroplasty (minimum 120 cases/year between 2 surgeons) is $384,600. Further cost saving from the process management changes were seen in central sterile processing time. Prior to the one tray system, the hospital had 3 in-house trays and there were 4 device company trays. We also noticed an approximate 27% improvement in turnover time. Conclusion. Repless model has significant cost saving potential. Preparation for the transition, proper patient selection, standardization of the trays and implants, and distribution of the responsibilities between OR nurses, technicians and the surgeon are essential


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 8 - 8
1 Dec 2021
Kamp MC van der Weegen W Liu W Goosen J( Rijnen W
Full Access

Aim. National Joint Replacement Registries, which are important sources for periprosthetic joint infection (PJI) data, report an average PJI incidence ranging from 0.5 to 2.0%. Unfortunately, national registries including the Dutch Arthroplasty Register (LROI), are not specifically designed to register PJI. In the Netherlands, the LROI is a nationwide population-based registry with an overall completeness of more than 95%. 3. To ensure usability and reliability of PJI data from the LROI, it is important to evaluate the quality and completeness of these data. From 2013 onwards, eight hospitals in the South-East of the Netherlands, collected their PJI data in a detailed regional infection cohort (RIC), specifically designed for this purpose. This study aimed to determine the accuracy and completeness of PJI registration (hip and knee arthroplasty) in the LROI, by comparing the LROI with the RIC. Method. All patients registered with an acute PJI in the RIC between 2014–2018 were selected for the study and were matched with the LROI. According to the Workgroup of American Musculoskeletal Infections Society (MSIS), an acute PJI was defined as at least two phenotypically identical pathogens, isolated in cultures from at least two separate tissues, obtained from the affected peri-prosthetic tissue during the DAIR treatment (debridement, antibiotics, irrigation, and retention). Only PJI occurring within 90 days after primary hip or knee arthroplasty were included. The LROI data and completeness was based on the entered procedures and documented reason for revision infection, which was not specially based on the MSIS criteria. After checks on missing and incorrectly data, the completeness of registration in the LROI was calculated by comparing the number of registrations in the LROI with data from the RIC (gold standard). Results. Of the 639 primary total hip and knee arthroplasty with a suspected PJI registered in the RIC between 2014–2018, 352 cases met the definition of acute PJI. The overall incidence was 1%. When compared with the LROI, 164 of these cases were also registered in the LROI as PJI revision, resulting in a 53% underestimation of PJI for the LROI. Conclusions. LROI data on acute PJI shows a significant underestimation, which is comparable to scarce other literature sources. To ensure reliability and usability of national PJI data, a specifically part of the LROI has to be designed for registering PJI similar to the regional cohort


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 101 - 101
1 Nov 2016
Taneja A Khong H Sharma R Smith C Railton P Puloski S Johnston K Powell J
Full Access

Patients undergoing Joint Arthroplasty received a significant proportion of blood transfusions. In this study, we compared the risk of Deep Infection, and Superficial Infection post operation following Primary Total Hip or Knee replacement in blood-transfused and non-blood-transfused patients. Cohort of patients who underwent primary total Hip or Knee Arthroplasty from April 2012 to March 2015 in Alberta. Patient characteristics, comorbidity, received blood transfusion were collected from electronic medical records, operating room information systems, discharge abstract database, provincial clinical risk grouper data. Deep Infection and Superficial Infection were captured from Provincial Surgical Site Infection Surveillance data. Deep Infection include deep incisional and organ/space infections. Logistic regression analysis were used to compare Deep Infection and Superficial Infection in blood-transfused and non-blood-transfused cohorts, and risk-adjusted for age, gender, procedure type, and co-morbidities. Our study cohort contains 27891 patients, with mean of age at admission was 66.3±10.4, 57.5% female, 49.3% had 1 or more comorbidities. 58.8% underwent Knee Replacement. 11.1% received blood transfusion during hospital stay (Total Hip Replacement (THR) =13.1% and Total Knee Replacement (TKR) =9.7%,). 1.1% had Deep Infection (THR=1.4% and TKR=0.9%) and 0.5% had Superficial Infection (THR=0.5% and TKR=0.5%). Blood-transfused patients got 1.7% Deep Infection and 1.0% Superficial infection. Non-blood-transfused patients got 1.0% Deep Infection and 0.5% Superficial infection. Controlling for age, gender, procedure type, and co-morbidities, the odds of Deep Infection were 1.6 times higher for blood-transfused patients than for non-blood-transfused patients (adjusted odds ratio [OR]=1.6, 95% confidence interval [CI] [1.2–2.2], p=0.004). The odds of Superficial Infection were 2.0 times higher for transfused patients (adjusted OR=2.0, 95% CI [1.3–3.0], p=0.002). Blood transfusion increases Deep Infection and Superficial Infection post-surgery following Primary Total Knee or Hip Replacement. This finding suggests to reduce the unnecessary blood transfusion for patients considering Joint Arthroplasty. Reducing the blood transfusion will save the inpatient cost and decrease the infective complications post-surgery in Hip or Knee Arthroplasty patients


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 13 - 13
1 Jun 2021
Anderson M Van Andel D Foran J Mance I Arnold E
Full Access

Introduction. Recent advances in algorithms developed with passively collected sensor data from smart phones and watches demonstrate new, objective, metrics with the capacity to show qualitative gait characteristics. The purpose of this feasibility study was to assess the recovery of gait quality following primary total hip and knee arthroplasty collected using a smartphone-based care platform. Methods. A secondary data analysis of an IRB approved multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total knee arthroplasty (TKA, n=88), unicondylar knee arthroplasty (UKA, n=28), and total hip arthroplasty (THA, n=82). Subjects were followed from 6 weeks preoperative to 24 weeks postoperative. The group was comprised of 117 females and 81 males with a mean age of 61.4 and BMI of 30.7. Signals were collected from the participants' smartphones. These signals were used to estimate gait quality according to walking speed, step length, and timing asymmetry. Post-operative measures were compared to preoperative baseline levels using a Signed-Rank test (p<0.05). Results. Mean walking speeds were lowest at postoperative week 2 for all three procedures (p<.001). The TKA population stabilized to preoperative speeds by week 17. For UKA cases, mean walking speeds rebounded to preoperative speed consistently by week 9 (p>.05). THA cases returned to preoperative walking speeds with a stable rebound starting at week 6 (p>.05), and improvement was seen at week 14 (p=.025). The average weekly step length was lowest in postoperative week 2 for both TKA and UKA (p<.001), and at week 3 for THA (p<.001). The TKA population rebounded to preoperative step lengths at week 9 (p=0.109), UKA cases at week 7 (p=.123), and THA cases by week 6 (p=.946). For TKA subjects, the change in average weekly gait asymmetry peaked at week 2 postoperatively (p <0.001), returning to baseline symmetry by week 13 (p=.161). For UKA cases, mean gait asymmetry also reached its maximum at week 2 (p =.006), returning to baseline beginning at week 7 (p=0.057). For THA cases mean asymmetry reached its maximum in week 2 (p <0.001) and was returned to baseline values at week 6 (p=.150). Discussion and Conclusion. Monitoring gait quality in real-world patient care following hip and knee arthroplasty using smart phone technology demonstrated recovery curves similar to previously reported curves captured by traditional gait analysis methods and patient reported outcome scores. Capturing such real-world gait quality metrics passively through the phone may also provide the advantage of removing the Hawthorne effect related to typical gait assessments and in-clinic observations, leading to a more accurate picture of patient function


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 196 - 196
1 Sep 2012
Akram T Templeton-Ward O Yousaf S Hargrove R
Full Access

Following the outcomes of the RECORD trials the protocol of extended thromboprophylaxis in patients undergoing elective primary total hip or knee arthroplasty has been changed in our institution. Between June 2008 and May 2009 patients were offered extended thromboprophylaxis with 150mg of aspirin daily, commencing preoperatively on admission and continuing for a total of six weeks. From June 2009 onwards patients were treated with 10mg of rivaroxaban once daily for two weeks following total knee and five weeks following total hip arthroplasty commencing 4 to 6 hours postoperatively. Our cohorts were 700 patients before and after the introduction of the new regimen. The two groups were matched for age, sex and type of operation. All patients with no contraindication to treatment with aspirin or rivaroxaban respectively undergoing elective primary total hip or knee arthroplasty were included in the study. Patients receiving warfarin on admission were treated with warfarin postoperatively and were excluded. We have compared the two treatment protocols in terms of safety and efficacy. Results focus on 4 safety outcome measures including mortality, haemorrhagic complications, transfusion requirements and infection rates and 2 efficacy outcome measures including thromboembolic complications and length of inpatient stay. Rates of DVT were equal in the two cohorts (P< 0.005) as were the mortality rates. Transfusion requirements post-operatively were not affected by the introduction of the new regimen however there was a significant increase in both return to theatre rates and prolonged wound ooze (P< 0.005). Infection rates were slightly higher in the cohort treated with rivaroxaban but this was not statistically significant. We conclude that further trials need to be done to confirm the suitability of routine use of rivaroxiban


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 51 - 51
10 Feb 2023
Gleeson C Zhu M Frampton C Young S Poutawera V Mutu-Grigg J
Full Access

The New Zealand Joint Registry (NZJR) was established in 1999. However, ethnicity data was not recorded by prioritisation in line with Ministry of Health (MoH) recommendations. Recently, cross-referencing with MoH updated ethnicity data for all 326,150 entries in the NZJR database. The objective of this national level, population study was to identify any ethnic disparities in access and outcome for Māori for primary total hip (THA) and knee arthroplasty (TKA) for Osteoarthritis. The utilisation rate for THA and TKAs were calculated for the Māori and NZ European population from all data in the NZJR and Census data in 2001, 2006, 2013 and 2018. Utilisation rate was reported separately for four age groups (<55, 55-64, 65-74, >75) over four time periods (1999-2004, 2005-2009, 2010-2014, 2015-2020). Revision rate, 6 months and 5-year Oxford scores were adjusted for age, sex and BMI, then compared between groups. In every age group and at all but one time point, significant under-utilisation of TKA was observed in Māori. For THAs, Māori had similar utilisation rates in the <55 and 55-64 age groups, but significantly lower utilisation rates in all other age groups. When adjusted for age, sex and BMI, no significant differences in revision rates were observed between Māori and NZ Europeans for THAs (HR 0.939, P 0.417) or TKAs (HR 1.129, P 0.149). Adjusted 6 months and 5-year Oxford scores were significantly higher in NZ Europeans, however, the maximum difference was less than 3 points and is unlikely to be clinically significant. Despite the same risk of being diagnosed with osteoarthritis, Māori are less likely to undergo THA and TKA. There are no clinically significant differences in outcomes post arthroplasty between Māori and NZ Europeans. Further research is required to investigate causes for lower utilisation in Māori


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 140 - 140
1 Feb 2020
Fassihi S Kraekel SM Soderquist MC Unger A
Full Access

Introduction. Enhanced Recovery After Surgery (ERAS) is a multi-disciplinary approach for establishing procedure–specific, evidence-based perioperative protocols to optimize patient outcomes. ERAS evidence is predominantly for non-orthopaedic procedures. We review the impact of ERAS protocol implementation on total joint arthroplasty (TJA) outcomes at our institution. Methods. All primary total hip and knee arthroplasties performed one year before and after ERAS implementation were identified by current procedural terminology code. Length of stay (LOS), disposition, readmission and opioid usage were analyzed before and after ERAS implementation and statistically analyzed with student t-test and chi-square test. Results. 2105 total patients were identified (967 THA, 494 pre-ERAS and 473 post-ERAS;1138 TKA, 575 pre-ERAS and 563 post-ERAS). TKA. After ERAS implementation, opioid consumption decreased for hospital day one (45.5MME to 36.2MME; p=0.000) and overall hospitalization (101.9MME to 83.9MME; p =0.000). Average LOS decreased (73.28hrs to 66.44hrs; p=0.000), blood transfusion rate trended down (3.3% to 1.95%; p=0.155), and disposition to home over skilled nursing facility increased (57.8% to 71.6%; p=0.000). Unplanned return-to-hospital encounters were unchanged (13.22% to 12.79%; p=0.8504). 30-day and 90-day readmission rates decreased (7.30% to 3.02%; p=0.0020 and 8.5% to 4.8%; p=0.0185, respectively). THA. After ERAS implementation, opioid consumption decreased for hospital day one (49.5MME to 35.4MME; p=0.000) and overall hospitalization (79.5MME to 59.5MME; p=0.000). Average LOS decreased (57.84hrs to 51.87hrs; p=0.011), blood transfusion rate was unchanged (4.25% to 3.81%; p=0.725), and disposition to home over skilled nursing facility increased (80.4% to 82.5%; p= 0.022). Unplanned return-to-hospital encounters were unchanged (8.51% to 8.88%; p=0.8486). Readmission trended up during postoperative days 0–30 and trended down during postoperative days 31–90. (1.42% to 2.96%; p=0.1074) and (1.21% to 0.85%; p=0.5748), respectively. Conclusion. ERAS protocols reduce postoperative opioid consumption, decrease hospital LOS, and increase patient disposition to home without adversely affecting short-term readmission rates


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 129 - 129
1 Jul 2020
Petruccelli D Wood T Winemaker MJ De Beer J
Full Access

Overall, hip and knee total joint replacement (TJR) patients experience marked benefit, with reported satisfaction rates of greater than 80% with regard to pain relief and improved function. However, many patients experience ‘nuisance’ symptoms, an annoyance which may cause discomfort, which can negatively impact postoperative satisfaction. The purpose of this study was to evaluate the prevalence of nuisance symptoms among TJR patients and impact on overall patient satisfaction. A prospective survey study to assess type and prevalence of primary hip/knee TJR related nuisance symptoms, and impact on patient satisfaction at six-months to one-year post-TJR was conducted. The survey was administered over a one-year period at one academic arthroplasty centre. Survey questions tapped occurrence of commonly reported nuisance symptoms (e.g. localized pain, swelling, stability, incision appearance/numbness, stiffness, clicking/noise, ability to perform activities of daily living), and impact of the symptom on overall hip/knee satisfaction rated on a 10-point visual analogue scale (VAS), (0=no impact, 10=to a great extent). Overall VAS satisfaction with TJR was also assessed (0=not at all satisfied, 10=extremely satisfied). Survey responses were analysed using descriptive statistics. The sample comprised of 974 primary TJR patients, including 590 knees (61%) and 384 hips 39%) who underwent surgery over a one-year period. Among knees, the most commonly reported nuisance symptoms and associated impact to satisfaction per mean VAS scores included: difficulty kneeling (78.2%, mean VAS 4.3, ±3.3), limited ability to run or jump (71.6%, VAS 3.3, ±3.3), numbness around incision (46.3%, VAS 3.8, ±3.3), clicking/noise from the knee (44.2%, VAS 2.7, ±2.7) and stiffness (43.3%, 3.3, ±2.7) following knee arthroplasty. Overall, 88.1% of knee patients surveyed experienced at least one self-reported nuisance symptom at one-year postoperative. Mean overall VAS satisfaction with knee TJR was reported as 9/10 (±1.7). Among hip TJR patients, the most commonly reported nuisance symptoms and associated impact to satisfaction per VAS scores were: limited ability to run or jump (68.6%, VAS 3.4, ±3.4), muscular pain in the thigh (44.8%, VAS 3 ±2.7), limp when walking (37.6%, VAS 4.1, ±3.2), hip stiffness (31%, VAS 3.1, ±2.4), and new or worsening low back pain (24.3%, VAS 2.9, ±2.5). Overall, 93.7% of patients experienced at least one self-reported nuisance symptom at one-year postoperative. Mean overall VAS satisfaction following total hip arthroplasty at one year was reported as 8.9/10 (±1.7). Nuisance symptoms following primary total hip and knee arthroplasty are very common. Despite the high prevalence of such symptoms, impact of individual symptoms to overall TJR satisfaction is minimal and overall TJR patient satisfaction remains high. Careful preoperative counselling regarding the prevalence of such symptoms is prudent and will help establish realistic expectations following primary hip and knee TJR


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 20 - 20
1 Apr 2019
Casale M Waddell B Ojard C Chimento G Adams T Mohammed A
Full Access

Background. Non-invasive hemoglobin measurement was introduced to potentially eliminate blood draws postoperatively. We compared the accuracy and effectiveness of a non-invasive hemoglobin measurement system with a traditional blood draw in patients undergoing total joint arthroplasty. Methods. After IRB approval, 100 consecutive patients undergoing primary total hip or knee arthroplasty had their hemoglobin level tested by both traditional blood draw and a non-invasive hemoglobin monitoring system. Results were analyzed for the entire group, further stratifying patients based on gender, race, surgery (THA versus TKA), and post-operative hemoglobin level. Finally, we compared financial implications and patient satisfaction with the device. Paired t-test with 0.05 conferring significance was used. Stratified analyses of the absolute difference between the two measures were assessed using Mann- Whitney test. To assess the level of agreement between the two measures, the concordance correlation coefficient (CCC) was calculated. Results. Mean blood-draw hemoglobin value on POD1 was 11.063 ± 1.39 g/dL and 11.192 ± 1.333 g/dL with the non-invasive device. For all patients, the mean absolute difference between the two methods was 0.13 g/dL (p = 0.30). The CCC between the two methods was 0.58, conferring a moderate to strongly positive linear relationship (Figure 1). Non-invasive measurement was preferred by 100% of patients with a mean VAS score of 0/10. Additionally, the cost savings with the non-invasive system was $16.50 per patient. Discussion. Overall, there was no significant difference between the hemoglobin level obtained by traditional laboratory methods versus the Masimo Radical-7 system on post-operative day #1 in patients who underwent total joint arthroplasty. In the minority of patients (19%) who had a hemoglobin level of less than 10 g/dL, the difference between the two methods was statistically significant. Additionally, 100% of patients preferred the Masimo device to a traditional blood draw and the Masimo device was substantially cheaper. While further investigation of non-invasive hemoglobin monitoring systems is necessary, particularly in patients with a post-operative hemoglobin of less than 10 g/dL, our study shows that the Masimo Radical-7 device provides an accurate, preferable, and less expensive alternative to a traditional blood draw after total joint replacement. Conclusion. Overall, the non-invasive hemoglobin monitoring system offered a similar hemoglobin reading to the standard lab-draw reading, while improving satisfaction and lowering cost. The system relies on adequate perfusion for measurement, and our study demonstrated that lower hemoglobin values may reduce finger-tip perfusion and affect the hemoglobin reading


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 139 - 139
1 Feb 2017
Godshaw B McDaniel G Thomas L Chimento G
Full Access

Introduction. Perioperative dexamethasone has been shown to effectively reduce post-operative nausea and vomiting and aide in analgesia after total joint arthroplasty (TJA), however systemic glucocorticoid therapy is carries the theoretical risk of increased susceptibility to prosthetic joint infection (PJI), increased white blood cell (WBC) counts, and increased blood glucose levels. The purpose of this study is to determine the effect of dexamethasone on PJI, WBC count, and blood glucose levels in diabetic and non-diabetic patients undergoing TJA. Methods. A retrospective chart review of all patients receiving primary total joint (hip or knee) arthroplasty between January 1, 2013 and December 31, 2015 (n = 1818) was conducted. The patients were divided into two main cohorts: those receiving dexamethasone (n = 1426) and those not receiving dexamethasone (n = 392); these groups were further subdivided into diabetic (n = 428 dexamethasone; n = 129 no dexamethasone) and non-diabetic patients (n = 998 dexamethasone, n = 263 no dexamethasone). The primary outcome was PJI; secondary measures included in (WBC) count, glucose levels, and days to infection. Statistics were carried out using chi-squared or ANOVA tests. Results. Of the 1818 joints, 1.05% (19) developed PJI; there was no significant difference between the dexamethasone and no dexamethasone groups (p = 0.1023): 12 (0.84%) in the dexamethasone group and 7 (1.79%) in the no-dexamethasone group. Additionally there was no significant effect on the increase in WBC count (p = 0.1784) or on the increase in blood glucose (p = 0.3120). Further subdividing the patients, there was a significantly higher rate of infection in those who received dexamethasone with diabetes (2.1%) compared to those without diabetes (0.30%) (p = 0.0016). Further, diabetics who received dexamethasone had a significantly greater elevation in blood glucose (p < 0.0001) compared to non-diabetics, but no significant change in WBC count (p = 0.6993). Conclusion. Perioperative intravenous dexamethasone had no statistically significant effect on the overall rate of prosthetic joint infections in primary total hip or knee arthroplasty; however diabetic patients had a significantly higher rate of infection compared to non-diabetics when given dexamethasone. WBC counts were not affected overall by administration of dexamethasone, or with stratification into diabetics and non-diabetics. Glucose levels were not effected by administration of dexamethasone


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 6 - 6
1 Apr 2012
Van der Walt P Nizami H
Full Access

We analysed the clinical data of 858 consecutive primary total hip and knee replacement patients to establish how age, ASA grade, body mass index and a simplified cognitive score correlate with the length of hospital stay and early complication rates. We further used statistical regression analysis to study how hospital stay and complication rates correlate with different pre-operative grading systems based on combinations of age, ASA grade, body mass index and a cognitive score. The results indicate that age and ASA grade correlate significantly with both length of hospital stay and complication rates, while body mass index correlated poorly with both. A grading system based on a combination of age and ASA grade (the AA Grade) correlated significantly with both length of hospital stay and complication rates. Adding body mass index or a cognitive score did not significantly add to the correlation. We discuss the relevance of this simple grading system and how it might contribute to pre-operative risk assessment and peri-operative planning


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 5 - 5
1 May 2012
Thomas W Dwyer A Porter P
Full Access

Aims. To establish if the principles of Enhanced Recovery, an evidence-based, integrated, multi-modal approach to improving recovery following colonic resection are transferable to elective orthopaedic primary arthroplasty surgery. The principles are to reduce the stress response provoked by surgery and eliminate the peri-operative catabolic state by optimally managing patients' metabolism, expectations, postoperative pain and mobility. This combination of interventions has not been tested in Orthopaedics before. Methods. We conducted a single surgeon, consecutive patient, interventional, cohort study of primary total hip and knee arthroplasties. Our intervention was Enhanced Orthopaedic Recovery (EOR). Results. We retrospectively reviewed 138 primary joint replacements. We performed a power calculation before prospectively assessing the next 50 hip and 32 knee arthroplasties. A two-tailed t-test showed a highly statistically significant fall in mean time to discharge (Hips 8.1-5.4 total nights stay, p=0.003, knees 8.5-5.3 total nights stay, p<0.001) and a fall in expected date of discharge from 5 to 3 postoperative days. We studied the complication and readmission rate and found no apparent difference. Conclusions. We have shown that by implementing EOR, reduced time to functional recovery and subsequent hospital discharge can be safely achieved with consequent quality of life and health economic benefits