Aims. The aim of this study was to estimate the clinical and economic burden of dislocation following
Aims. The aim of this study was to report the long-term follow-up of cemented short Exeter femoral components when used in
Aims. The Forgotten Joint Score-12 (FJS-12) is a validated patient-reported outcome measure (PROM) tool designed to assess artificial prosthesis awareness during daily activities following total hip arthroplasty (THA). The patient-acceptable symptom state (PASS) is the minimum cut-off value that corresponds to a patient’s satisfactory state-of-health. Despite the validity and reliability of the FJS-12 having been previously demonstrated, the PASS has yet to be clearly defined. This study aims to define the PASS of the FJS-12 following
Aims. The Exeter V40 femoral stem is the most implanted stem in the National Joint Registry (NJR) for
Aims. Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. Methods. We retrospectively identified 55 patients who underwent
The aim of this study was to determine both the incidence of, and the reoperation rate for, postoperative periprosthetic femoral fracture (POPFF) after total hip arthroplasty (THA) with either a collared cementless (CC) femoral component or a cemented polished taper-slip (PTS) femoral component. We performed a retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All POPFFs were identified using regional radiograph archiving and electronic care systems.Aims
Methods
The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression.Aims
Methods
Aims. Contemporary outcomes of
Aims. Periprosthetic femoral fracture (PPF) is a major complication following total hip arthroplasty (THA). Uncemented femoral components are widely preferred in
Total hip arthroplasty (THA) is the only successful treatment for patients in whom the hip joint is destroyed by inflammatory arthritis. Due to the effects of both the disease and its treatment elevated rates of complications and of aseptic loosening have been described. Whether with modern uncemented hip prostheses the results can be improved is not fully known. Therefore, we decided to carry out a prospective study.
At the introduction of a new press-fit acetabular component a prospective study on the results of uncemented THA was started. From 1995 to 1999 85 primary THAs were carried out in 72 patients (57 women, 15 men) suffering from inflammatory arthritis. Diagnosis: RA 76, adult-onset Still 4, JIA 3, miscellaneous 2. Mean age at operation was 60 years (SD 15. 9). Clinically, the Harris Hip Score was used for evaluation. Radiographically, the Larsen classification was used and at follow-up radiolucencies and signs of migration were registered. The implants used in this study were the EPF-PLUS® acetabular component and the SL-PLUS® femoral component (PLUS Endoprothetik AG, Rotkreuz-CH). The EPF-PLUS® acetabular component is a novel modular press-fit cup. Its shell has a triple radius profile on cross-section, thereby creating a gradual lowering of the polar part of the cup. This produces a small gap of about 2 mm. between the acetabulum and the pole of the cup. Therefore, forces are mainly transmitted to the peripheral part of the acetabulum, leading to an enhanced primary stability. Originally, the shell had a gritblasted surface for osseointegration. Since 1996, the outer surface of the cup has been coated with a ground layer of pure titanium and a superficial layer of a crystalline hydroxyapatite (Ti-HA). The gritblasted version was used in 14 hips (1995–1996), the Ti-HA coated version in 71 hips. In 68 hips the cup was implanted by press-fit fixation, in 17 screws were added.
Larsen classification was as follows: 0-1: 6; 3: 17; 4: 60; 5: 2. At follow-up, 5 patients (6 THAs) were deceased. Deep infection required revision in one hip. Another revision was carried out for recurrent dislocations. One grit-blasted cup developed late subsidence and was revised almost 4 years postoperatively. One Ti-HA coated cup failed early due to severe acetabular bone loss. Finally, one femoral component developed a varus tilt and became symptomatic 2 years after implantation, requiring revision. In all 62 patients with 74 THAs in follow-up cup and stem are functioning well, both clinically and radiographically. Harris Hip Score increased from 36. 6 (SD 17. 7) to 87. 9 (SD 11. 8).
The medium-term results of the EPF®-PLUS cup show that its primary stability is good and that, as the polar gap rapidly disappears, osseointegration is secure. Only severe acetabular deficiency appears to be a contra-indication for this implant. Also, the SL-PLUS® stem performs well in inflammatory arthritis.
Aims. Breast cancer survivors have known risk factors that might influence the results of total hip arthroplasty (THA) or total knee arthroplasty (TKA). This study evaluated clinical outcomes of patients with breast cancer history after
In
Polished taper-slip (PTS) cemented stems have an excellent clinical track record and are the most common stem type used in
Aims. There is inconsistent evidence on whether prior spinal fusion surgery adversely impacts outcomes following total hip arthroplasty (THA). We conducted a systematic review and meta-analysis to assess the association between pre-existing spinal fusion surgery and the rate of complications following
Literature data show varying rates of aseptic loosening of standard hemispherical cups after
Aims. Although there is increasing legalization of the use of cannabis in the USA, few well-powered studies have evaluated the association between cannabis use disorder and outcomes following
Arthrofibrosis is a relatively frequent complication after total knee arthroplasty. Although stiffness after total hip arthroplasty (THA), because of formation of heterotopic ossification or other causes, is not uncommon, to the authors’ best knowledge, arthrofibrosis after THA has not been described. The aim of this study is to describe the arthrofibrosis of the hip after
Aims. The aim of this study was to determine the prevalence of depressive and anxiety disorders prior to total hip (THA) and total knee arthroplasty (TKA) and to assess their impact on the rates of any infection, revision, or reoperation. Methods. Between January 2000 and March 2019, 21,469 primary and revision arthroplasties (10,011 THAs; 11,458 TKAs), which were undertaken in 15,504 patients at a single academic medical centre, were identified from a 27-county linked electronic medical record (EMR) system. Depressive and anxiety disorders were identified by diagnoses in the EMR or by using a natural language processing program with subsequent validation from review of the medical records. Patients with mental health diagnoses other than anxiety or depression were excluded. Results. Depressive and/or anxiety disorders were common before THA and TKA, with a prevalence of 30% in those who underwent
Aims. In recent years, the use of a collared cementless femoral prosthesis has risen in popularity. The design intention of collared components is to transfer some load to the resected femoral calcar and prevent implant subsidence within the cancellous bone of the metaphysis. Conversely, the load transfer for a cemented femoral prosthesis depends on the cement-component and cement-bone interface interaction. The aim of our study was to compare the three most commonly used collared cementless components and the three most commonly used tapered polished cemented components in patients aged ≥ 75 years who have undergone a
Aim. Prosthetic joint infection (PJI) is a serious complication following total hip arthroplasty (THA) entailing increased mortality, decreased quality of life, and high healthcare costs. In 2009 a nationwide, multidisciplinary infection control program was launched in Sweden, PRISS, which aimed to reduce the PJI burden by 50%. The primary aim was to investigate whether the PRISS project reduced PJI incidence after