Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 67 - 67
7 Nov 2023
Mogale N van Schoor A Scott J Schantz D Ilyasov V Bush TR Slade JM
Full Access

Pressure ulcers are a common occurrence in individuals with spinal cord injuries, and are attributed to prolonged sitting and limited mobility. This therefore creates the need to better understand soft tissue composition, in the attempt to prevent and treat pressure ulcers. In this study, novel approaches to imaging the soft tissue of the buttocks were investigated in the loaded and unloaded position using ultrasound (US) and magnetic resonance imaging (MRI).

Twenty-six able-bodied participants (n=26, 13 males and 13 females) were recruited for this study and 1 male with a spinal cord injury. Two visits using US were required, as well as one MRI visit to evaluate soft tissue thickness and composition. US Imaging for the loaded conditions was performed using an innovative chair which allowed image acquisition in the seated upright position and MRI was done in the lateral decubitus position and loading was applied to the buttocks using a newly developed MRI compatible loader. The unloaded condition was a lateral decubitus position. Soft tissue was measured between the peak of the ischial tuberosity (IT) and the proximal femur and skin.

Tissue thickness reliability for US was excellent, ICC=0.934–0.981 with no significant differences between the scan days. US and MRI measures of tissue thickness were significantly correlated (r=0.68–0.91). US underestimated unloaded tissue thicknesses with a mean bias of 0.39 – 0.56 for total tissue and muscle + tendon thickness. When the buttocks were loaded, total tissue thickness was reduced by 64.2±9.1%.

US assessment of soft tissue thicknesses was reliable in both positions. The unloaded measurements using US were validated with MRI with acceptable limits of agreement, albeit tended to underestimate tissue thickness. Tissue thickness, but not fatty infiltration of muscle played a role in how the soft tissue of the buttocks responded to loading.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 185 - 186
1 Apr 2005
Latte V Guadalascara F D’Elia A Rossi S
Full Access

Osteoporosis is an underdiagnosed and often neglected disease, with a huge impact on social costs arising from fracture management that could be avoided with an appropriate prevention programme. The approach to diagnosis is not always efficacious and cost-optimised, often suggesting instrumental densitometry in a somehow irrational way. The objective of this study is to evaluate the introduction and use of a simple score system, in order to optimise the access to instrumental diagnosis with quantitative ultrasound (QUS) densitometric technique for those patients at risk. We used the OSIRIS score system questionnaire in order to have a simple tool to manage the osteoporosis screening of patients in our centre from January to December 2003 (more than 2000 patients in total). The score risk derived for each patient was used to recommend the instrumental densitometric measurement (heel QUS) and the need for vertebral X-ray scan and morphometric evaluation. In a further analysis on a more limited number of patients, we searched for correlations between densitometry with other score systems (O.R.A.I.,N.O.F.,S.C.O.R.E.,A.B.O.N.E.) and with pre-existing fragility fractures (vertebral and non-vertebral). Our data suggest that a correlation exists between OSIRIS score risk and heel QUS densitometric T-score, suggesting the usefulness and validity of such a score system in order to optimise the access to instrumental diagnosis of osteoporosis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 54 - 54
1 Jun 2012
Lam T Hung VY Yeung H Chu W Ng B Lee K Qin L Cheng J
Full Access

Introduction. The main challenge in management of adolescent idiopathic scoliosis (AIS) is to predict which curve will progress so that appropriate treatment can be given. We previously reported that low bone mineral density (BMD) was one of the adverse prognostic factors for AIS. With advancement in imaging technology, quantitative ultrasound (QUS) becomes a useful method to assess bone density and bone quality. The objective of this study was to assess the role of QUS as a radiation-free method to predict curve progression in AIS. Methods. 294 girls with AIS were recruited at ages 11–16 years and followed up until skeletal maturity. 269 age-matched healthy girls were recruited as controls. They provided the normal reference for calculation of Z score for QUS parameters. QUS measurements, including BUA (broadband ultrasound attenuation), VOS (velocity of sound) and SI (stiffness index) of the calcaneum, BMD of femoral neck, menarche history, ages, and Cobb angle of the major curve were recorded at baseline as independent variables. The predictive outcome was curve progression defined as an increase of Cobb angle of 6° or more. Logistic regression model and the ROC curve were used for statistical analysis. Results. Mean follow-up was 3·4 years (SD 1·57). At baseline, mean age was 13·4 years (1·23), 73 (24·8%) patients were premenarchal, and mean Cobb angle was 26·3° (SD 8·2°). 202 (68·7%), 194 (66%), and 202 (68·7%) of patients with AIS had Z score of BUA, VOS, and SI of 0 or less, respectively. Initial univariate analysis indicated all independent variables had p values less than 0.2. Logistic regression analysis indicated that the p values of their regression coefficients were: age (p<0·001), menarchal status (p<0·001), Cobb angle (p=0·008), BMD (p=0·084), BUA (p=0·722), VOS (p=0·112), and SI (p=0·027). SI, age, menarchal status, and Cobb angle were therefore included in the final prediction equation. The adjusted odds ratio for Z score of SI of 0 or less was 2·00 (95% CI 1·08–3·71). The area under the ROC curve was 0·831(95% CI 0·785–0·877). The predictive model had a sensitivity of 0·847 and a specificity of 0·665 at a probability cutoff of 0·368. Conclusions. We recorded evidence of deranged bone density and bone quality in AIS, as indicated by QUS investigation. SI is an independent and significant prognostic factor for AIS. It can be used as a radiation-free parameter to predict curve progression in combination with initial Cobb angle, age, and menarchal status, especially when DXA is not available. Acknowledgments. This study is supported by Research Grant Council—The government of HKSAR (project number CUHK4498/06M)


Bone & Joint Open
Vol. 6, Issue 3 | Pages 291 - 297
7 Mar 2025
Zambito K Kushchayeva Y Bush A Pisani P Kushchayeva S Peters M Birch N

Aims. Assessment of bone health is a multifaceted clinical process, incorporating biochemical and diagnostic tests that should be accurate and reproducible. Dual-energy X-ray absorptiometry (DXA) is the reference standard for evaluation of bone mineral density, but has known limitations. Alternatives include quantitative CT (q-CT), MRI, and peripheral quantitative ultrasound (QUS). Radiofrequency echographic multispectrometry (REMS) is a new generation of ultrasound technology used for the assessment of bone mineral density (BMD) at axial sites that is as accurate as quality-assured DXA scans. It also provides an assessment of the quality of bone architecture. This will be of direct value and significance to orthopaedic surgeons when planning surgical procedures, including fracture fixation and surgery of the hip and spine, since BMD alone is a poor predictor of fracture risk. Methods. The various other fixed-site technologies such as high-resolution peripheral q-CT (HR-pQCT) and MRI offer no further significant prognostic advantages in terms of assessing bone structure and BMD to predict fracture risk. QUS was the only widely adopted non-fixed imaging option for bone health assessment, but it is not considered adequately accurate to provide a quantitative assessment of BMD or provide a prediction of fracture risk. In contrast, REMS has a robust evidence base that demonstrates its equivalence to DXA in determining BMD at axial sites. Fracture prediction using REMS, combining the output of fragility information and BMD, has been established as more accurate than when using BMD alone. Conclusion. The practice parameters described in this protocol provide a framework for clinicians who provide REMS services that will, to the greatest possible extent, ensure the most accurate assessment possible from this diagnostic technology. Cite this article: Bone Jt Open 2025;6(3):291–297


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 465 - 465
1 Apr 2000
Fogelman I


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 283 - 283
1 Mar 2004
Saarakkala S Hirvonen J Laasanen M Nieminen H Jurvelin J TšyrŠs J
Full Access

Aims: The objective of this study was to investigate the ability of ultrasound backscattering to detect degeneration of articular cartilage. For this aim, ultrasound B-mode images were acquired from the surfaces of normal and degenerated bovine cartilage samples. Methods: Cylindrical osteochondral samples (n=31) with different degenerative cartilage appearance were prepared from the bovine patellae. Subsequently, degenerative stages of the samples were quantiþed using the Mankin score method. Ultrasound B-mode images of the samples were obtained using a 20 MHz ultrasound instrument (CortexTech.,Denmark).Biomechanical reference measurements were conducted using a stress-relaxation protocol (10% prestrain, 10% strain, 2 mm/s ramp velocity) in unconþned compression geometry. Results: Average reßection coefþcient ( ARC) (r=0.58) and integrated reßection coefþcient ( IRC) (r=0.53) correlated positively with the cartilage dynamic modulus. Furthermore, moduli decreased as a function of Mankin score (r ≤ −0.68). Finally, strong linear correlations were established between the backscattering parameters and the Mankin score (r=−0.79 for the ARC and r =−0.78 for the IRC). Conclusions: Results of this study suggest that ultrasound backscattering from the articular surface is able to diagnose the degeneration of AC. Theoretically, it is also possible to evaluate changes in subchondral bone with the backscatter measurements. In conclusion, ultrasound backscattering, when applied arthroscopically in vivo, may signiþcantly beneþt clinical diagnostics of early osteoarthrosis as well as monitoring of tissue healing after cartilage repair surgery.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 62 - 62
1 Nov 2018
Nwawka OK Lin B Toresdahl B Allen A Drakos M
Full Access

This study of collegiate basketball players evaluated change over time (COT) in ultrasound shear wave (SW) elastography metrics across the basketball season, and correlated to morphologic changes on conventional ultrasound imaging, and VISA-P scores. In eleven male collegiate basketball players (mean age 19, age range 18–21), patella tendon (PT) ultrasound and SW elastography of both knees were performed at pre-season and post-season time points, and players reported their VISA-P scores throughout the season. Patella tendinopathy grade and SW metrics were correlated to VISA-P scores using Spearman correlation coefficients. Paired t-test was used to assess differences in mean SW metrics at pre-and post-season timepoints, accounting for leg dominance. 6 of 11 players (54.5%) had baseline patella tendinopathy on ultrasound progressing in 4 players. The mean change in VISA-P score was 15.18 (+/−8.55). No significant correlation was seen between ultrasound grades of tendinopathy and VISA-P. Pre-season SW velocities did not significantly correlate with baseline VISA-P scores. Post-season SW values and SW COT demonstrated strong correlation with change in VISA-P score in dominant and non-dominant knees. Although not statistically significant, there was a trend towards higher SW velocity for tendinopathy in both dominant and non-dominant knees at both study visits. SW metrics of the PT correlated to change in VISA-P scores in the dominant and non-dominant knees, whereas conventional ultrasound grades of patella tendinopathy did not. There was a trend towards higher SW velocities in patella tendinopathy which may indicate detection of change in intrinsic tissue stiffness.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 106 - 106
4 Apr 2023
Ding Y Luo W Chen Z Guo P Lei B Zhang Q Chen Z Fu Y Li C Ma T Liu J
Full Access

Quantitative ultrasound (QUS) is a promising tool to estimate bone structure characteristics and predict fragile fracture. The aim of this pilot cross-sectional study was to evaluate the performance of a multi-channel residual network (MResNet) based on ultrasonic radiofrequency (RF) signal to discriminate fragile fractures retrospectively in postmenopausal women. Methods. RF signal and speed of sound (SOS) were obtained using an axial transmission QUS at one‐third distal radius for 246 postmenopausal women. Based on the involved RF signal, we conducted a MResNet, which combines multi-channel training with original ResNet, to classify the high risk of fragility fractures patients from all subjects. The bone mineral density (BMD) at lumber, hip and femoral neck acquired with DXA was recorded on the same day. The fracture history of all subjects in adulthood were collected. To assess the ability of the different methods in the discrimination of fragile fracture, the odds ratios (OR) calculated using binomial logistic regression analysis and the area under the receiver operator characteristic curves (AUC) were analyzed. Results. Among the 246 postmenopausal women, 170 belonged to the non-fracture group, 50 to the vertebral group, and 26 to the non-vertebral fracture group. MResNet was discriminant for all fragile fractures (OR = 2.64; AUC = 0.74), for Vertebral fracture (OR = 3.02; AUC = 0.77), for non-vertebral fracture (OR = 2.01; AUC = 0.69). MResNet showed comparable performance to that of BMD of hip and lumbar with all types of fractures, and significantly better performance than SOS all types of fractures. Conclusions. the MResNet model based on the ultrasonic RF signal can significantly improve the ability of QUS device to recognize previous fragile fractures. Moreover, the performance of the proposed model modified by age, weight, and height is further optimized. These results open perspectives to evaluate the risk of fragile fracture applying a deep learning model to analyze ultrasonic RF signal


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 111 - 111
1 Nov 2018
Kraszewski A Drakos M Hillstrom H Toresdahl B Allen A Nwawka O
Full Access

This investigation of elite male collegiate basketball players aims to determine 1) the change in 3D dynamic functional variables across a single season and 2) correlate cross-season changes in functional variables with changes in clinical and quantitative ultrasound measures. Eleven male college basketball players (mean age 19, range 18–21 years) from a single team underwent baseline patellar tendon shear wave (SW) elastography and dynamic function at the start of the season (Visit1) and at a late-season time point (Visit2). Players reported their VISA-P scores every two weeks across their 24-week season. Each athlete performed a box-ground-box jump five times while 3D lower extremity kinematic and kinetic variables were collected. Functional measures included for landing (LAND) and take-off (TOFF) phases: knee valgus angle, valgus torque, and peak limb force. Knee valgus angular impulse and ground contact time were also measured. Paired t-tests and Pearson correlation coefficients (r) compared Visit1 and Visit2 variables and assessed the strength of linear dependency, respectively. The mean change in VISA-P score was 15.18 (+/-8.55). No functional variables were different across the season. Clinical, quantitative ultrasound and functional variables were moderately correlated with take-off valgus moment, landing force, take-off force and contact time. Other correlations were low (< 0.4). Our analyses have shown moderate correlations between important clinical, quantitative imaging and function measurements. These correlations reflect the changes that occur between relevant time points and which relate internal structure and external function


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 497 - 503
1 May 2002
Hedström M åström K Sjöberg H Dalén N Sjöberg K Brosjö E

A total of 63 women who had an operation for a fracture of the hip was randomly allocated to one year of treatment either with anabolic steroids, vitamin D and calcium (anabolic group) or with calcium only (control group). The thigh muscle volume was measured by quantitative CT. The bone mineral density of the hip, femur and tibia was assessed by quantitative CT and dual-energy x-ray absorptiometry and of the heel by quantitative ultrasound. Quantitative CT showed that the anabolic group did not lose muscle volume during the first 12 months whereas the control group did (p< 0.01). There was less bone loss in the proximal tibia in the anabolic group than in the control group. The speed of gait and the Harris hip score were significantly better in the anabolic group after six and 12 months. Anabolic steroids, even in this moderate dose, given in combination with vitamin D and calcium had a beneficial effect on muscle volume, bone mineral density and clinical function in this group of elderly women


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 347 - 347
1 May 2010
Chatzipapas C Drosos G Kazakos K Tripsianis G Staikos C Verettas D
Full Access

Objectives: The aim of this study was to explore the relationship between stress fractures, bone density and factors related to bone metabolism in a comparative group matched study including male military personnel beyond basic training. Materials and Methods: Thirty two patients with stress fractures were matched with 32 uninjured-healthy volunteers (controls), by gender, age, height, body weight and level of physical performance. A questionnaire concerning the calcium intake, alcohol consumption and smoking was completed, the values of several biochemical markers related to bone metabolism were measured from blood samples, and calcaneal quantitative ultrasound was measured by heel ultrasound for each one of the 64 patients and healthy volunteers. Results: Statistically significant lower levels of serum Osteocalcin (p=0.012) and higher levels of Albumin (p=0.006) were found among patients compared to controls. The levels of serum Total Protein, Ca, intact Parathormone and 25-hydroxy Vitamin D were lower among patients compared to controls, but none of these differences was statistically significant (all p> 0.10). Moreover, mean values of T-scores and Z-scores were statistically significantly lower in patients than in controls (p=0.018 for T-scores; p=0.016 for Z-scores). Conclusions: Decreased bone turnover and low calcaneal bone density may increase the incidence of lower extremity stress fractures among men military personnel


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 98 - 98
1 Aug 2012
Cook R Curwen C Tasker T Zioupos P
Full Access

Osteoporosis (OP) results in a reduction in the mechanical competence of the bone tissue of the sufferers. In skeletal sites such as the proximal femur and the vertebrae, OP manifests itself in low trauma fragility fractures which are debilitating for the patient. The relationships between the compressive strength of cancellous tissue and its apparent density are well established in studies of the past. Recently the authors have presented a method able to assess the fracture toughness properties of cancellous bone (1), a challenging cellular material which can exhibit large elasto-plastic deformations. The in-vitro measurement of fracture toughness alongside the customary compressive strength can provide a comprehensive assessment of the mechanical capacity of cancellous bone, which will reflect closer its ability to resist crack initiation. The aims of the present study were: (1) to examine whether the observed fracture toughness deterioration can also be detected by non-invasive quantitative ultrasound (QUS); and (2) to provide rational evidence for the well proven ability of QUS to predict directly ‘risk of fracture’. 20 femoral heads were obtained from donors undergoing emergency surgery for a fractured neck of femur. QUS investigations of the calcaneus, proximal phalanx and distal radius were undertaken within 72 hours of surgery. 128 fracture toughness samples and 20 compression cores were manufactured and tested. Two clinical QUS systems were used to obtain in-vivo scan data and then directly compared those to the density, porosity and the fracture mechanics of tissue extracted from the same individuals. The results demonstrated not only that there was a significant link between in-vivo determined QUS values for the calcaneus and finger to the density of the density of the femoral head; but that there was also a significant link between the QUS results from the calcaneus and the fracture toughness of the cancellous bone from the femoral head. These results point towards a systemic effect of osteoporosis which affects similarly different parts of the skeleton and supports the use of clinical QUS systems as a diagnostic tool for the prediction of fracture risk


Bone & Joint Research
Vol. 14, Issue 1 | Pages 33 - 41
17 Jan 2025
Fujimoto K Kanamoto T Otani S Miyazaki R Ebina K Nakata K

Aims. Ultrasound-guided injection techniques are expected to enhance therapeutic efficacy for skeletal muscle injuries and disorders, but basic knowledge is lacking. The purpose of this study was to examine the diagnostic accuracy of ultrasound for abnormal skeletal muscle lesions, and to examine the distribution patterns of solution and cells injected into abnormal muscle lesions under ultrasound guidance. Methods. A cardiotoxin (CTX)-induced muscle injury model was used. Briefly, CTX was injected into tibialis anterior muscle in rats under ultrasound observation. First, the diagnostic accuracy of abnormal muscle lesions on ultrasound was examined by comparing ultrasound findings and histology. Next, Fast Green solution and green fluorescent protein (GFP)-labelled cells were simultaneously injected into the abnormal muscle lesions under ultrasound guidance, and their distribution was evaluated. Results. Evaluation of short-axis ultrasound images and cross-sectional histological staining showed a strong correlation (r = 0.927; p < 0.001) between the maximum muscle damage area in ultrasound and haematoxylin and eosin (H&E) staining evaluations. Histological analysis showed that ultrasound-guided injection could successfully deliver Fast Green solution around the myofibres at the site of injury. In contrast, the distribution of injected cells was very localized compared to the area stained with Fast Green. Conclusion. This experimental animal study demonstrated the potential of ultrasound to quantitatively visualize abnormalities of skeletal muscle. It also showed that ultrasound-guided injections allowed for highly accurate distribution of solution and cells in abnormal muscle tissue, but the patterns of solution and cell distribution were markedly different. Although future studies using a more clinically relevant model are necessary, these results are important findings when considering biological therapies for skeletal muscle injuries and disorders. Cite this article: Bone Joint Res 2025;14(1):33–41


Bone & Joint Research
Vol. 10, Issue 12 | Pages 840 - 843
15 Dec 2021
Al-Hourani K Tsang SJ Simpson AHRW