Aims. The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain
Increasing the accuracy of information provided through X-Rays maximises pre-operative planning. Aim of this project is to determine the necessity of calibration probes that would improve the accuracy of pre-operative templating. This is a retrospective study involving leg length and pelvis X-Rays performed across the NHS Lanarkshire from 01/03/2023 until 31/04/2024. A total of 87 leg length X-Rays were identified, 18 had a calibration probe present. Leg length was measured on each and the X-Rays were calibrated against the existing probe. In 66.7% of cases there was a major leg length discrepancy of over 2cm between the pre-calibrated and post-calibrated X-Rays. Pelvic X-Rays of 80 patients that underwent total hip replacement were reviewed. Preoperative templating was compared to the implants inserted. An average of 1.94 discrepancy in the size of the acetabular implant was identified whilst in 30 cases the size of the femoral stem was incorrect by at least 1 size. Magnification of 119.7% on X-Rays was found to provide the most accurate templating. Seventy seven cases of pelvic X-Rays before and after hip hemiarthroplasty were also reviewed. The implant head was templated incorrectly in 74% of cases and the stem in 51%. It was identified that pelvic
Aims. In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia. Patients and Methods. Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on
Assessment of stability in ankle fractures is key in deciding the most appropriate mode of treatment. Stress
Introduction. High Tibial Osteotomy has become an increasingly popular management option for patients with painful medial compartment osteoarthritis. The Fujisawa method used to calculate the angle of correction is well-documented but there have been no studies to look at the reliability and accuracy of web-based systems to calculate this angle. Patients and Methods. Patients undergoing valgus high tibial osteotomy between October 2004 and February 2010 who had full-length lower-limb views on the Picture Archiving and Communications System (PACS). The Fujisawa angle and length of osteotomy were calculated by the surgeon and two Orthopaedic registrars who had been appropriately trained. Results. Thirty X-rays were reviewed in 28 patients. Mean difference between measurements was 0.43 mm (SD 2.45) There was a statistically significant correlation between all three raters (P < 0.001). The greatest correlation was between the Consultant and the more senior trainee (r=0.86) with the lowest correlation between the Consultant and the more junior trainee (r=0.70). Concordance correlation coefficient between raters varied from 0.81 to 0.63. Bland-Altman plot of agreement between the Consultant and senior trainee was excellent showing only two values lying outside 1.96 SD. Discussion. Comparison of measurements between raters showed increased accuracy with greater experience of the measurement technique. Despite this we show high correlation between raters with measurement accuracy of all raters found within clinically acceptable limits (< 1mm). Conclusion. Measurement of tibial osteotomy using the fujisawa method on a web-based
Aims. To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. Methods. A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1). Results. We included 120 fractures in 119 patients. Compared to
Myriad protocols exist for isolated Weber B lateral malleolus fractures with a congruent tibiotalar joint on initial
Aims. Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. Methods. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative
Aims. In the Netherlands, general practitioners (GPs) can request
Accurate evaluation of lower limb coronal alignment is essential for effective pre-operative planning of knee arthroplasty. Weightbearing hip-knee-ankle (HKA)
To develop a reliable and effective radiological score to assess the healing of isolated ulnar shaft fractures (IUSF), the Radiographic Union Score for Ulna fractures (RUSU). Initially, 20 patients with
Aims. There is a lack of published evidence relating to the rate of nonunion seen in occult scaphoid fractures, diagnosed only after MRI. This study reports the rate of delayed union and nonunion in a cohort of patients with MRI-detected acute scaphoid fractures. Methods. This multicentre cohort study at eight centres in the UK included all patients with an acute scaphoid fracture diagnosed on MRI having presented acutely following wrist trauma with normal
Aims. The aims of this study were to identify means to quantify coronal plane displacement associated with distal radius fractures (DRFs), and to understand their relationship to radial inclination (RI). Methods. From posteroanterior digital
Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative
This study describes the introduction of a virtual pathway for the management of suspected scaphoid fractures and reports patient-reported outcome measures (PROMs) and satisfaction following treatment with this service. All adult patients that presented with a clinically suspected scaphoid fracture that was not visible on presentation
Midfoot arthrodesis is the conventional surgical intervention for midfoot arthritis. Arthrodesis aims to stabilise, realign and fuse the affected joints, providing patients with improved pain and function. Current research neglects the measurement of patient reported outcomes. This study aimed to investigate objective, and patient reported outcomes of midfoot arthrodesis. The secondary aim was to identify variables predicting the development of non-union. An automated search of online patient records identified 108 eligible patients (117 feet). The rates of union, re-operations, and complications were calculated using
Sub-acromial decompression surgery (SAD) has been widely used to treat shoulder impingement. Its validity has been questioned in multi-centric clinical trials and dissatisfaction rates can be high (35%). It is difficult to predict which patients will benefit operatively as research into predictive factors is limited. The study aim was to conduct a root-cause analysis of reasons for dissatisfaction in a cohort of operated patients. All patients with SAD dissatisfaction in the local Upper Limb database between 2015-19 (n=74/296) formed our study cohort. Patients were scored on Oxford shoulder score (OSS), QuickDASH score, EQ-5D-3L (TTO+VAS) at weeks 26 and 52 post-operatively. Patients' clinical history,
Restoration of native Coronal Plane Alignment of the Knee (CPAK) phenotype is a strategy suggested to achieve better satisfaction. The aim of this study was to investigate the influence of changes in CPAK classification on patient-reported outcome measures (PROMs) and survivorship in a large cohort of manual mechanically aligned (MA) cemented TKAs. A retrospective analysis of 1062 consecutive cemented TKAs using MA philosophy at a single institution. Pre- and post-operative hip-knee-ankle
Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to
Introduction. We aim to assess whether radiographic characteristics of the greater tuberosity fragment can predict rotator cuff tears inpatients with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity. Methods. A retrospective single-centre case series of 61 consecutive patients that presented with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity between January 2018 and July 2022. Inclusion criteria: patients with atraumatic anterior shoulder dislocation associated with an isolated fracture of the greater tuberosity with a minimum follow-up of 3-months. Exclusion criteria: patients with other fractures of the proximal humerus or glenoid. Rotator cuff tears were diagnosed using magnetic resonance or ultrasound imaging. Greater tuberosity fragment size and displacement was calculated on plain