Advertisement for orthosearch.org.uk
Results 1 - 20 of 139
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 167 - 167
1 Jan 2013
Morris C Kumar V Sharma S Morris M Raut V Kay P
Full Access

Financial impact and patient satisfaction with four different anticoagulants for hip and knee arthroplasty in patients with a previous history of VTE- A prospective randomised trial. Introduction. New generation oral anticoagulants (dabigatran/rivaroxaban) have recently become available for the prevention of venous thromboembolism (VTE) following hip and knee arthroplasty. Traditional therapies (warfarin/low molecular weight heparins) are less costly, but have several limitations. The aim of this study was to evaluate the financial impact of substituting enoxaparin and warfarin with newer therapies dabigatran and rivaroxaban. A secondary objective was to investigate patient satisfaction with these treatments. Methods. A randomised prospective study was conducted over a 12 month period. Patients with a history of VTE undergoing hip or knee replacement were randomised to receive one of four anticoagulants for five weeks post surgery. Information was gathered during the hospital stay and then post discharge, by telephone, for five weeks(35 days)to determine costs. The costs included cost of drug, nursing time, blood monitoring and transport costs. The patients were also asked to complete the Duke Anticoagulation Satisfaction Scale (DASS). The DASS is a 26 item questionnaire which has 7 responses for each question. Results. Although dabigatran and rivaroxaban had higher drug acquisition costs, warfarin and enoxaparin were financially more costly overall. These additional costs were mainly due to increased blood monitoring and time for training and administration which is not required for newer therapies. DASS scores were significantly better with dabigatran (38.5±5.1) and rivaroxaban (38.6±8.3) compared to warfarin (71.8±16.2) and enoxaparin (68.5±14.2) (p< 0.001). This indicates more satisfaction for patients prescribed dabigatran or rivaroxaban compared to traditional therapies. Conclusion. The use of new generation oral anticoagulants has the potential to significantly reduce the financial burden of thromboprophylaxis on the NHS with an additional benefit of better patient satisfaction when compared to traditional therapies


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 23 - 23
1 Jan 2013
Strambi F Yeo A Riva G Buly J Hisole J Field R
Full Access

Introduction

Total hip arthroplasty (THA) is undertaken to relieve pain and to restore mobility. The orthopaedic community remains divided on the influence of surgical approach in achieving functional recovery most quickly and effectively. We report a study comparing THA performed through a posterior (Posterior) against anterior approach (Heuter).

Methods

Fifty patients were prospectively enrolled and randomized for Posterior or Heuter procedures. Informed patient consent and local ethics approval was obtained. All patients received an uncemented, ceramic-on-ceramic prosthesis performed by a single surgeon.

Functional outcome was assessed by time to achieve milestones of walking, stair climbing, hip movement and balance. Kinematic data on level-ground walking and the effect of fatigue was assessed using a portable gait analysis system at 6-, 12-, and 24-weeks post-operatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 236 - 236
1 Sep 2012
Roche J Joss B DeSteiger R Miller L Nivbrant B Wood D
Full Access

There is ongoing debate on the benefits of fixed versus mobile bearing Unicompartmental Knee Replacement (UKR). We report the results from a randomised controlled trial comparing fixed and mobile bearing of the same UKR prosthesis. Forty patients were randomized to receive identical femoral components and either a fixed or mobile bearing tibial component. At 6.5 years follow-up 37% of the mobile bearing design had been revised and 14% for the fixed bearing design. The main reasons for revision were pain and loosening. These results were compared with data from The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) that show a cumulative percent revision of 24.2% for the mobile bearing Preservation UKR at 6.5 years. All locally explanted mobile bearings were examined microscopically, and 83% demonstrated significant backside wear. Constraint on the undersurface of the bearing coupled with a congruent upper surface may have contributed to the excessive revision rate. This is the first randomised controlled trial examining mobile and fixed variations of the same UKR prosthesis and shows this design of UKR with the mobile bearing has an unacceptably high revision rate and patients with this knee design should be closely monitored


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 397 - 402
1 Apr 2001
Freedman KB Back S Bernstein J

We reviewed all 717 manuscripts published in the 1997 issues of the British and American volumes of the Journal of Bone and Joint Surgery and in Clinical Orthopaedics and Related Research, from which 33 randomised, controlled trials were identified. The results and sample sizes were used to calculate the statistical power of the study to distinguish small (0.2 of standard deviation), medium (0.5 of standard deviation), and large (0.8 of standard deviation) effect sizes. Of the 33 manuscripts analysed, only three studies (9%) described calculations of sample size. To perform post-hoc power assessments and estimations of deficiencies of sample size, the standard effect sizes of Cohen (small, medium and large) were calculated. Of the 25 studies which reported negative results, none had adequate power (β < 0.2) to detect a small effect size and 12 (48%) lacked the power necessary to detect a large effect size. Of the 25 studies which did not have an adequate size of sample to detect small differences, the average used was only 10% of the required number. Our findings suggest that randomised, controlled trials in clinical orthopaedic research utilise sample sizes which are too small to ensure statistical significance for what may be clinically important results


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 69 - 69
1 Jan 2013
Hanusch B Gregg P Hui A
Full Access

Introduction. High flexion knee arthroplasties have been designed to allow up to 155 degrees flexion and enable high flexion activities such as kneeling and squatting. To date randomised controlled trials have shown no difference in range of movement (ROM) between high flexion and standard designs. Objectives. The aim of this study was to determine if there is a difference in functional outcome and ROM between the standard and high flexion design of the PFC Sigma TKA system. Methods. 84 patients with the diagnosis of osteoarthritis undergoing primary total knee arthroplasty were randomised to receive either a PFC Sigma or PFC Sigma RP-F total knee arthroplasty. ROM, Oxford Knee Score, Knee Society Score, Patella score and SF-12v2 were assessed independently before and at one year after surgery. Patients were blinded to the implant they received. Results. 42 patients in each group were included in this study and underwent surgery. 77 patients (92%) completed their one-year follow-up. There was no statistically significant difference in preoperative scores between groups. At one year there was a statistically significant difference in ROM between the groups with a mean of 105 degrees in the PFC Sigma and 114 degrees in the PFC Sigma RP-F group (p=0.01). There was also a statistically significant difference in flexion with 106 degrees and 115 degrees respectively (p=0.007). The difference in improvement in ROM and flexion was also statistically significant between the groups (p=0.009 and p=0.008). There was no statistically significant difference in any of the functional outcome scores. Conclusions. This is the first randomised controlled trial to show a statistically significant difference in ROM and flexion between a standard and a high flexion design TKA. Further follow-up will be carried out to determine if these differences persist over time and to evaluate the long-term survival of the different designs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 72 - 72
1 Jan 2013
Hamilton D Gaston P Patton S Burnett R Howie C Simpson H
Full Access

Introduction. Many prosthetic design changes have been introduced in attempt to improve outcomes following TKA; however there is no consensus as to whether these changes confer benefits to patients. This study aimed to assess whether patients treated with a modern implant design had an enhanced patient outcome compared to a traditional model in a double blind randomised controlled trial. Methods. 212 consecutive patients were prospectively randomised to receive either a modern (Triathlon) or a traditional (Kinemax) TKA (both Stryker Orthopaedics). 6 surgeons at a single unit performed all procedures in a standardised manner. A single researcher, blinded to implant allocation, performed all assessments. Patients were assessed pre-operatively, and at 6, 26, 52 weeks post-surgery with the Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, goniometry, timed functional assessment, lower limb power (Leg Extensor Power Rig) and pain numerical rating scales (NRS). Change in scores and between group differences were assessed with Two-Way Repeated Measures ANOVAs. Results. Both groups benefited from TKA demonstrating significant improvement in all parameters (p = < 0.001 in all cases). Significant interaction of the implant was observed in 1 year change score of OKS (F = 4.28, p = 0.04), knee flexion (F = 8.42, p = 0.004), lower limb power output (F = 11.33, p = 0.001) and maximal pain report (F = 7.44, p = 0.001), the modern implant superior in each case. Larger change scores were observed in WOMAC and timed functional assessments, but were not statistically significant. Conclusions. In a large prospective double blind randomised controlled trial, patients receiving a modern implant design demonstrated a significantly enhanced patient outcome in terms of knee range of motion, lower limb power output, reduced maximal pain report, and a clinically meaningful reduction in the OKS compared to a traditional design


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 245 - 245
1 Sep 2012
Khan L Will E Keating J
Full Access

Introduction. The aims of this study were to undertake a prospective randomised trial to compare functional outcome, strength and range of motion after treatment of medial collateral ligament injuries by either early unprotected mobilisation or mobilisation with a hinged brace. Methods. Patients were randomised into either unprotected mobilisation or mobilisation with a hinged brace. Assessments occurred at 2 weeks, 6 weeks, 3 months and 6 months. Outcome measures included validated questionnaires (International Knee Documentation Committee and Knee Injury and Osteoarthritis Outcome Score scores), range of motion measurements and strength testing. Results. Eighty six patients (mean age 30.4) were recruited. There were 53 men and 33 women. The mode of injury was sport in 56 patients (65%) with football, rugby and skiing being the most common types of sport involved. The mean time to return to full weight bearing was 3 weeks in both groups. The mean time to return to work was 4.6 weeks in the braced group and 4.1 weeks in the non-braced group (p=0.79). Return to running was at a mean of 14.3 weeks in the braced group and 12.8 weeks in the non-braced group (p=0.64). Return to full sport was 22 weeks in the braced group and 22.1 weeks in the non-braced group (p=0.99). There was no significant difference in range of movement or pain scores between the two groups at 2,6,12 and 24 weeks. Conclusions. The use of a hinged knee brace does not influence recovery after a medial collateral injury


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 67 - 67
1 Jan 2013
Liddle A Pandit H Jenkins C Price A Gill H Dodd C Murray D
Full Access

Unicompartmental Knee Replacement (UKR) is associated with fewer complications, faster recovery and better function than Total Knee Replacement (TKR). However, joint registries demonstrate a higher revision rate in UKR, limiting its use. Currently most UKRs are cemented and performed using a minimally invasive technique. In joint registries, common reasons for revision include aseptic loosening and pain. These problems could potentially be addressed by using cementless implants, which may provide more reliable fixation. The objectives of this study were to compare the quality of fixation (determined by the incidence and appearance of radiolucencies), and clinical outcomes of cemented and cementless UKR at five years. A randomised controlled trial was established with 63 knees (62 patients) randomised to either cemented (32 patients) or cementless UKR (30 patients). Fixation was assessed with fluoroscopic radiographs aligned to the bone-implant interface at one and five years. Outcome scores were collected pre-operatively and at one, two and five years, including Oxford Knee Score (OKS), American Knee Society Score, objective and functional (AKSS-O/F) and Tegner Activity Scale (TAS), expressed as absolute scores and 0–5 year change (δ) scores. Four patients died during the study period. There were no revisions. Mean operative time was 11 minutes shorter in the cementless group (p=0.029). At five years, there was no significant difference in any outcome measure except AKSS-F and δAKSS-F which were significantly better in the cementless group (both p=0.003). There were no femoral radiolucencies in either group. There were significantly more tibial radiolucencies in the cemented group (20/30 vs 2/27, p< 0.001). There were nine complete radiolucencies in the cemented group and none in the cementless group (p< 0.001). Cementless fixation provides improved fixation at five years compared to cemented fixation in UKR, maintaining equivalent or superior clinical outcomes with a shorter operative time and no increase in complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 91 - 91
1 Sep 2012
Raman R Singh J Johnson G Sharma H Day N Shaw C
Full Access

Introduction

Viscosupplementation is used widely to provide symptomatic relief to patients with knee OA. This study aimed to compare the efficacy and safety of the standard (3×2ml) and single (1×6ml) dosing regimens of hylan G-F 20.

Methods

Prospective, randomized, blinded (reviewers), comparative independent study. Inclusion criteria was OA knee pain e 60mm on a 100mm VAS; no prior intra articular (IA) injection. Patients were randomised to recieve 1 × 6mL or 3 × 2mL hylan G-F 20. Follow-up at 1, 6, 12, 26 and 52 weeks. Analgesics prohibited for 24 hours prior to follow-up assessments and NSAID's for 26 wks. All adverse events (AE) were recorded. Primary outcome measure: Target knee pain (VAS) at 26 weeks. Secondary outcome measures included WOMAC, Oxford knee score, SF12


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 78 - 78
1 Sep 2012
McKay G Harvie P Sloan K Beaver R
Full Access

We report our five-year functional results comparing navigated and conventional total knee replacement. To our knowlege this represents the first Level 1 study comparing function in navigated and conventional total knee replacement at five years.

An origianl cohort of 71 patients undergoing Duracon (Stryker Orthopaedics, St. Leonards, Australia) total knee replacement without patellar resurfacing were prospectively randomised to undergo operation using computer navigation (Stryker Image Free Computer Navigation System (version 1.0; Stryker Orthopaedics))(n=35) or a jig-based method (n=36). The two groups were matched for age, gender, height, weight, BMI, ASA grade abd pre-operative deformity. All operations were performed by a single surgeon. Reviews were undertaken by senior physiotherpist blinded to participant status using validated outcome scoring tools (Knee Society Score, WOMAC Score and Short Form SF-36 Score). All patients underwent CT scanning of the implanted prosthesis as per Perth CT Knee Protocol to assess component alignment.

After 5 years 24 patients in the navigated group and 22 patients in the conventional group were available for review. At 5 years no statistically significant difference was seen in any of the aforementioned outcome scores when comparing navigated and conventional groups. No statistically significant differencewas seen between 2- and 5-year results for either group.

Due to the relatively low numbers in each group these data were compared with retrospective cohorts of navigated (n=100) and conventional (n=70) Duracon total knee replacements performed outwith this study over the same 5-year period. WITHIN the retrospective cohorts no statistically significant differences were found when comparing any of the aforementioned outcome scores. In addition, when comparing parallel scores between prospective and retrospective groups again no statistically significant differences were identified.

At 5-years post-operatively the functional outcome between computer navigated and conventional total knee replacement appears to be no different despite the better alignment achieved using navigation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 27 - 27
1 Sep 2012
Dawson-Bowling S Yeoh D Edwards H East D Ellens N Miles K Butler-Manuel P Apthorp H
Full Access

Introduction

Debate continues regarding the relative advantages of ceramic-on-ceramic (CoC) and metal-on-polyethylene (MoP) articulations in total hip arthroplasty (THA). Perceived benefits of CoC include longevity, and low wear - in turn limiting the effects of particulate wear debris. However, CoC bearings cost significantly more, and concern remains over the risk of ceramic fracture; a complication not seen with MoP bearings, which are also cheaper.

Method

We electronically randomised 268 consecutive patients undergoing THA to receive either a CoC or MoP articulation. Patients aged over 72 were excluded. In all patients the prosthesis used was an uncemented ABG II (Stryker, USA), implanted by one of the two senior authors (HDA, ABM). Patients were scored preoperatively, and at annual follow-up clinics, using SF36, Visual Analogue (VAS), Merle d'Aubigné (MD) and Oxford Hip (OHS) Scores. Satisfaction levels were also documented.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 71 - 71
1 Sep 2012
Hanratty B Thompson N Bennett D Robinson A Mullan C Beverland D
Full Access

Increasing knee flexion following total knee arthroplasty (TKA) has become an important outcome measure. Surgical technique is one factor that can influence knee motion. In this study, it was hypothesised that stripping of the posterior knee capsule could improve flexion and range of motion (ROM) following TKA. Patients who were undergoing TKA were prospectively randomised into two groups - one group (62 patients) were allocated stripping of the posterior knee capsule (PCS), the other group (66 patients) no stripping (no-PCS). The primary outcome was change in flexion and ROM compared to pre-operative measurements at three time points; after wound closure, 3months and 1year post-operatively. Secondary outcomes were absolute measurements of flexion, extension, ROM and complications. All operations were performed by a single surgeon using the same implant and technique. All patients received identical post-operative rehabilitation. There was a significant gain in flexion after wound closure in the PCS group (p=0.022), however there was no significant difference at 3months or 1year post-operatively. Absolute values of extension (p=0.008) and flexion (p=0.001) 3months post-operatively were significantly reduced for the PCS group. The absolute value of ROM was significantly higher for the no-PCS group at 3months (p=0.0002) and 1year (p=0.005). There were no significant difference in the rate of complications. Posterior capsular stripping causes a transient increase in flexion that does not persist post-operatively. We do not recommend routine stripping of the posterior knee capsule in patients undergoing TKA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 36 - 36
23 Feb 2023
Ma N Gogos S Moaveni A
Full Access

Surgical site infections following orthopaedic surgery are a serious complication associated with increased morbidity and mortality. Intra-wound antibiotic powder may be able to provide infection prophylaxis locally with less systemic adverse effects, and promising results have been reported in systematic reviews of its use in spine surgery. This study aims to analyse the efficacy and adverse effect profile of intra-wound antibiotics in reducing surgical site infections in orthopaedic surgery for traumatic pelvic and lower limb fractures. A systematic review was conducted for studies reporting on the incidence of surgical site infections following administration of intra-wound antibiotic powder in pelvic and lower limb trauma surgery. Randomised controlled trials, cohort and case-control studies were included. A meta-analysis was conducted for deep surgical site infections. Seven studies were included in the systematic review including six retrospective case-control studies and one randomised controlled trial. Results of the meta-analysis suggest a potential 23% reduction in the odds of developing a deep surgical site infection in patients treated with intra-operative antibiotic powder compared with those managed with intravenous antibiotics alone (OR 0.77, 95% CI 0.52 – 1.13), although the results did not reach statistical significance. Notable selective bias against intra-wound antibiotics and suboptimal study design were found in the retrospective studies, however the randomised controlled trial reported a significant reduction in deep surgical site infections with intra-wound vancomycin powder. There were no reports of systemic adverse outcomes and minimal risk of wound complications with the use of intra-wound antibiotics. This review suggests the use of intra-wound antibiotic powder in pelvic and lower limb trauma surgery may reduce the incidence of deep surgical site infections. Further powered studies including randomised controlled trials are required to confirm the results highlighted in this study


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 12 - 12
10 May 2024
Sevic A Patel C Tomlinson M
Full Access

Introduction. Comparative studies examining Fixed-Bearing (FB) and Mobile-Bearing (MB) Total Ankle Replacement (TAR) designs have demonstrated similar results and successful long-term outcomes for both. To date there has been no study directly comparing FB and MB designs of the same prosthesis. We present the first prospective randomised trial comparing patient satisfaction, functional outcomes and radiographic results of the Salto Talaris Fixed-Bearing and the Salto Mobile-Bearing Total Ankle Replacement in the treatment of end-stage ankle arthritis. Methods. A total of 108 adult patients with end-stage ankle arthritis were enrolled in the study between November 2014 and October 2021 with similar demographic comparison. Prospective patient-reported outcomes and standardised weightbearing ankle radiographs were performed preoperatively, at 6 weeks, 6 months and 12 months post-operatively, followed by yearly intervals. All surgeries were performed by a single non-design orthopaedic foot and ankle specialist with experience in over 200 Salto and Salto Talaris TAR prior to the study. Radiographs were examined independently by two clinicians. Complete patient data and radiographs were available for 103 patients with an average follow up of 2 years. Results. Both groups demonstrated statistically significant improvement from preoperative evaluation to most recent follow up with no statistically significant difference between the two groups in all outcome measures. Radiographic incidence of subchondral cyst formation was 8.9% and 38.2% for FB and MB, respectively. Talar subsidence occurred in 2.2% and 5.5% of FB and MB, respectively. Discussion. Our study demonstrates a higher than previously reported rate of cyst formation in the MB TAR and comparatively higher talar subsidence in the MB TAR vs FB however this did not correlate with clinical outcome measures which were favourable for both groups. Conclusion. Fixed-Bearing and Mobile-Bearing Total Ankle Replacement demonstrate comparable favourable


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 18 - 18
23 Feb 2023
Grant M Zeng N Lin M Farrington W Walker M Bayan A Elliot R Van Rooyen R Sharp R Young S
Full Access

Joint registries suggest a downward trend in the use of uncemented Total Knee Replacements (TKR) since 2003, largely related to reports of early failures of uncemented tibial and patella components. Advancements in uncemented design such as trabecular metal may improve outcomes, but there is a scarcity of high-quality data from randomised trials. 319 patients <75 years of age were randomised to either cemented or uncemented TKR implanted using computer navigation. Patellae were resurfaced in all patients. Patient outcome scores, re-operations and radiographic analysis of radiolucent lines were compared. Two year follow up was available for 287 patients (144 cemented vs 143 uncemented). There was no difference in operative time between groups, 73.7 v 71.1 mins (p= 0.08). There were no statistical differences in outcome scores at 2 years, Oxford knee score 42.5 vs 41.8 (p=0.35), International Knee Society 84.6 vs 84.0 (p=0.76), Forgotten Joint Score 66.7 vs 66.4 (p=0.91). There were two revisions, both for infection one in each group (0.33%). 13 cemented and 8 uncemented knees underwent re-operation, the majority of these being manipulation under anaesthetic (85.7%), with no difference (8.3% vs 5.3%, 95% CI -2.81% to 8.89%, p = 0.31). No difference was found in radiographic analysis at 2 years, 1 lucent line was seen in the cemented group and 3 in the uncemented group (0.67% v 2.09%, 95%CI -4.1% to 1.24%, p = 0.29). We found no difference in clinical or radiographic outcomes between cemented and uncemented TKR including routine patella resurfacing at two years. Early results suggest there is no difference between cemented and uncemented TKR at 2 years with reference to survivorship, patient outcomes and radiological parameters


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 14 - 14
12 Dec 2024
Kakwani M Pujol-Nicolas A Griffiths A Hutt N Townshend D Murty A Kakwani R
Full Access

Objectives. Minimally invasive surgery (MIS) has gained popularity for hallux valgus, compared to the traditional scarf osteotomy (OS). Though evidence suggests similar clinical outcomes, there is paucity of randomised controlled studies. This study aimed to assess the feasibility of conducting a randomised controlled trial comparing the patient recorded and clinical outcomes for the surgical management of Hallux Valgus between OS and MIS Chevron Akin (MICA). Methods. Patients suitable for surgical correction were invited to participate. Post-op rehabilitation was standardised for both groups. Patients completed a validated questionnaire (Manchester Oxford Foot questionnaire and EQ-5D-5L) pre-operatively and post-operatively at 6 months and 1 year. Radiological parameters and range of motion were measured pre-and post-operatively. Results. 31 patients were recruited between Dec 2017 and June 2022. 17 patients were randomised to MICA (15 female, mean age 51) and 15 to OS (14 female, mean age 51). Both groups had a significant improvement in all MOXFQ parameters at 6m and 12m, as well as radiological parameters. VAS improved for OS (p=0.048) and for MICA (p=0.059) at 6m. There was no significant improvement in EQ-5D in either group at 12 months and no significant difference in operative time (p=0.53). There was a higher number of complications in the MICA group with 5 removal of metalwork (29.4%) and 2 superficial infections (11.8%) versus none in the OS group. The dorsiflexion significantly improved in the OS group at 6months (p=0.04). Recruitment rate dipped during COVID. No patients were lost at follow up. Conclusion. Both surgical options show similar clinical results, but higher complication rates were seen with MICA. This study illustrates the feasibility to conduct a randomised control trial for the comparison between the two techniques. Challenges to recruitment included surgeon equipoise, patient preference, training requirement and the pandemic which could be mitigated in a larger study


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 36 - 36
1 Nov 2016
Barrack R
Full Access

Tourniquet use in total knee arthroplasty (TKA) is convenient for the surgeon and provides a bloodless field for expeditious surgery and a dry field for cementation, but can best be described as an orthopaedic tradition. It is logical for complex anatomy of ligament, nerve, and vessel surgery but it may not be necessary for TKA. In one recent randomised trial, the absence of the tourniquet was not found to affect the quality of cement fixation. There are numerous potential downsides to the use of a tourniquet including decrease range of motion, delayed recovery, increased pain, wound complications, micro-emboli, neuropathy, and increased VTE. There are also a number of complications associated with the use of a tourniquet including arterial thrombosis, skin irritation below the tourniquet, post-operative hyperemia, blood loss, less accurate intra-operative assessment, and it complicates intravenous drug administration. Studies of range of motion have shown that when there is a difference noted, the range of motion is consistently better without tourniquet use. When a tourniquet is utilised it has been found to be advantageous to only use the tourniquet for a minimal amount of the case, typically when cementing is performed. Functional strength has also been found to be improved without the use of a tourniquet. In a recent randomised trial, tourniquet use was associated with decreased quad strength at 3 weeks that persisted at 3 months. This was attributed to muscle damage, tourniquet-induced ischemia, and compressive injury. Increased peri-operative pain has also been reported in randomised trials associated with the use of a tourniquet. Edema, swelling, and limb girth issues have also been noted to be associated with tourniquet use. Exsanguinating a limb will result in swelling approximately 10% of the original volume half due to a return of blood, and half due to reactive hyperemia. Longer tourniquet times are also associated with increased wound drainage and more wound hypoxia as measured by transcutaneous oxygen levels. Tourniquet use has also been associated with embolic phenomenon with several times greater risk of large emboli. In one study where quantitative MRI was utilised on both thighs after unilateral total knee replacement with and without a tourniquet, the tourniquet group showed more atrophy with a loss of 20% of the volume compared to the normal side in total knees performed with a tourniquet which also performed clinically worse. There is a small but substantial risk of arterial thrombosis particularly in patients that have atherosclerotic plaque. Ironically there is a risk of increased post-operative blood loss due to the post-tourniquet “blush” as the blood pressure and pain increase hours after a surgical procedure is completed. There is also difficulty in identifying and coagulating posterior and lateral geniculate vessels with the components in place. Utilizing a tourniquet also interferes with intra-operative assessment of patella tracking, range of motion, ligament stability, and gap balancing. Randomised clinical trials have concluded that there is less pain and quicker recovery without the use of a tourniquet. There have also been reports of less swelling, increased range of motion, less analgesic use and better clinical outcome when a tourniquet is not utilised. A meta-analysis of systematic reviews favored not utilizing a tourniquet due to the decrease in complication rate and the improvement in clinical results. While it is standard practice in the US to utilise a tourniquet, the strong consensus of the literature on the subject favors either not using a tourniquet or minimizing the use of a tourniquet for the period of time necessary for a very dry field for cement fixation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 23 - 23
10 May 2024
Leary J Lynskey T Muller A
Full Access

Objective. Carpal tunnel release surgery is a commonly performed procedure for alleviating symptoms of median nerve compression and restoring hand function. With pressure on theatre time these procedures are now commonly performed in a step-down out-patient facility under local anaesthetic. The choice of suture for skin closure in this procedure can impact the quality of wound healing, patient outcomes and the follow-up required however the question of the best type of suture remains unanswered. The purpose of this study was to compare the outcomes of absorbable and non-absorbable sutures using a randomised control trial design. Methods. Eighty patients diagnosed with bilateral carpal tunnel syndrome were enrolled and underwent outpatient carpal tunnel release surgery under local anaesthetic in a staged fashion. Random number generation was used to assign each hand to receive interrupted nylon or Vicryl Rapide sutures. Pre-operative data collection included patient demographics, ASA, inflammatory conditions, smoking status as well as a Boston Carpal Tunnel Questionnaire (BCTQ) for each hand. Patients were followed up at 2 and 6 weeks after each operation and the BCTQ was repeated along with the Patient and Observer Scar Assessment Scale and the VAS score for wound discomfort. This study has approval from the DHB ethics committee, Local Iwi, HDC and ANZ Clinical Trials:ACTRN12623000100695. Results. Statistical analysis assessed patient preference and the scores between the groups. Multi-variate analysis was performed to assess the factors that may be contributing to patient choice. Conclusion. Insights into patient preference and clinical outcomes associated with absorbable sutures and non-absorbable sutures in the setting of out-patient surgery are discussed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 69 - 69
10 Feb 2023
Tong Y Holmes S Sefton1 A
Full Access

There is conjecture on the optimal timing to administer bisphosphonate therapy following operative fixation of low- trauma hip fractures. Factors include recommendations for early opportunistic commencement of osteoporosis treatment, and clinician concern regarding the effect of bisphosphonates on fracture healing. We performed a systematic review and meta-analysis to determine if early administration of bisphosphonate therapy within the first month post-operatively following proximal femur fracture fixation is associated with delay in fracture healing or rates of delayed or non-union. We included randomised controlled trials examining fracture healing and union rates in adults with proximal femoral fractures undergoing osteosynthesis fixation methods and administered bisphosphonates within one month of operation with a control group. Data was pooled in meta-analyses where possible. The Cochrane Risk of Bias Tool and the GRADE approach were used to assess validity. For the outcome of time to fracture union, meta-analysis of three studies (n= 233) found evidence for earlier average time to union for patients receiving early bisphosphonate intervention (MD = −1.06 weeks, 95% CI −2.01 – −0.12, I. 2. = 8%). There was no evidence from two included studies comprising 718 patients of any difference in rates of delayed union (RR 0.61, 95% CI 0.25–1.46). Meta-analyses did not demonstrate a difference in outcomes of mortality, function, or pain. We provide low-level evidence that there is no reduction in time to healing or delay in bony union for patients receiving bisphosphonates within one month of proximal femur fixation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 24 - 24
1 Jun 2018
Taunton M
Full Access

Total hip arthroplasty (THA) has been cited as one of the most successful surgical procedures performed today. However, as hip surgeons, we desire constantly improving outcomes for THA patients with more favorable complication rates. At the same time, patients desire hip pain relief and return to function with as little interruption of life as possible. The expectation of patients has changed; they have more physical demands for strength and flexibility, and aspire to achieve more in their recreational pursuits. Additionally, health care system constraints require the THA episode of care to become more efficient as the number of procedures increases with time. These factors, over the past fifteen years, have led to a search for improved surgical approaches and peri-operative pain and rehabilitation protocols for primary THA. The orthopaedic community has seen improved pain control, length of stay, and reduction in complications with changes in practice and protocols. However, the choice of surgical approach has provided significant controversy in the orthopaedic literature. In the 2000s, the mini-posterior approach (MPA) was demonstrated as the superior tissue sparing approach. More recently, there has been a suggestion that the direct anterior approach (DAA) leads to less muscle damage, and improved functional outcomes. A recent prospective randomised trial has shown a number of early deficits of the posterior approach when compared to the direct anterior approach. The posterior approach resulted in patients taking an additional 5 days to discontinue a walker, discontinue all gait aids, discontinue narcotics, ascend stairs with a gait aid, and to walk 6 blocks. Patients receiving the posterior approach required more morphine equivalents in the hospital, and had higher VAS pain scores in the hospital than the direct anterior approach. Interestingly, activity monitoring at two weeks post-operatively also favored DAA with posterior approach patients walking 1600 steps less per day than DAA patients. There has been little difference in the radiographic outcomes or complications between approaches in prospective randomised trials. A number of randomised clinical trials have demonstrated that both the direct anterior and posterior approach provided excellent early post-operative recovery with a low complication rate. DAA patients have objectively faster recovery with slightly shorter times to achieve milestones of function, with similar radiographic and clinical outcomes at longer-term outcomes, with a similar complication rate