Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 347 - 347
1 Dec 2013
Higa M Chang C Roche C Struk A Farmrer K Wright T Banks S
Full Access

Introduction. Persistent problems and relatively high complication rates with reverse total shoulder arthroplasty (RTSA) are reported (1, 2). It is assumed that some of these complications are affected by improper intraoperative soft tissue tension. Achieving proper intraoperative soft tissue tension is an obvious surgical goal. However, intraoperative soft tissue tension measurements and methods for RTSA have not been reported. One way to quantify soft tissue tension is to measure intraoperative joint forces using an instrumented prosthesis. Hence, we have developed an instrumented RTSA to measure shoulder joint forces intraoperatively. The goal of this study was to measure intraoperative shoulder joint forces during RTSA. Materials and Methods. The instrumented shoulder prosthesis measures the contact force vector between the glenosphere and humeral tray. This force sensor is a custom instrumented trial implant that can be used with an existing RTSA system (EQUINOXE, Exactech Inc, Gainesville, FL) just as a standard trial implant is used. Four uniaxial foil strain gauges (QFLG-02-11-3LJB, Tokyo Sokki Kenkyujo Co., Ltd., JP) are instrumented inside the sensor. Using a calibration matrix, the three force components were calculated from four strain gauge outputs (3). Sixteen patients who underwent RTSA took part in this IRB approved study. All patients were greater than 50 years of age and willing to review and sign the study informed consent form. After obtaining informed consent for surgery, a standard deltopectoral approach to the shoulder was performed. The instrumented trial prostheses were assembled on the glenoid baseplate instead of a standard glenosphere. After the joint was reduced, joint forces were recorded during cyclic rotation, flexion, scapular plane movement (scaption), and adduction of the shoulder. Strain gauge outputs were recorded during these movements as well as the neutral position just before movements. Mean values of forces with each motion were compared by one-way analysis of variance (ANOVA). A multiple comparisons test was subsequently performed to examine differences between motions. Results. Three sensors failed due to intraoperative breakage of strain gauge wires, leaving 13 subjects with measured joint reaction forces. During abduction, for example, the force vector varied from superior to antero-medial, and the resultant joint force in abduction was 83 N in a representative subject (Figure 1). Average joint reaction forces decreased with shoulder motion from a neutral position to external rotation or scaption. Conversely, they increased with flexion or abduction (Figure 2). Mean force values were not the same for each movement (p = 0.018). Forces recorded during flexion and scaption movements differed significantly (p = 0.012). Discussion. The intraoperative forces acting in the RTSA have been measured for the first time, and these measurements are ongoing. We expect more measurements will permit surgeons objectively to place and align implant components to achieve predictable and durable RTSA results


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 5 - 5
1 Feb 2020
Burton W Myers C Rullkoetter P
Full Access

Introduction. Gait laboratory measurement of whole-body kinematics and ground reaction forces during a wide range of activities is frequently performed in joint replacement patient diagnosis, monitoring, and rehabilitation programs. These data are commonly processed in musculoskeletal modeling platforms such as OpenSim and Anybody to estimate muscle and joint reaction forces during activity. However, the processing required to obtain musculoskeletal estimates can be time consuming, requires significant expertise, and thus seriously limits the patient populations studied. Accordingly, the purpose of this study was to evaluate the potential of deep learning methods for estimating muscle and joint reaction forces over time given kinematic data, height, weight, and ground reaction forces for total knee replacement (TKR) patients performing activities of daily living (ADLs). Methods. 70 TKR patients were fitted with 32 reflective markers used to define anatomical landmarks for 3D motion capture. Patients were instructed to perform a range of tasks including gait, step-down and sit-to-stand. Gait was performed at a self-selected pace, step down from an 8” step height, and sit-to-stand using a chair height of 17”. Tasks were performed over a force platform while force data was collected at 2000 Hz and a 14 camera motion capture system collected at 100 Hz. The resulting data was processed in OpenSim to estimate joint reaction and muscle forces in the hip and knee using static optimization. The full set of data consisted of 135 instances from 70 patients with 63 sit-to-stands, 15 right-sided step downs, 14 left-sided step downs, and 43 gait sequences. Two classes of neural networks (NNs), a recurrent neural network (RNN) and temporal convolutional neural network (TCN), were trained to predict activity classification from joint angle, ground reaction force, and anthropometrics. The NNs were trained to predict muscle and joint reaction forces over time from the same input metrics. The 135 instances were split into 100 instances for training, 15 for validation, and 20 for testing. Results. The RNN and TCN yielded classification accuracies of 90% and 100% on the test set. Correlation coefficients between ground truth and predictions from the test set ranged from 0.81–0.95 for the RNN, depending on the activity. Predictions from both NNs were qualitatively assessed. Both NNs were able to effectively learn relationships between the input and output variables. Discussion. The objective of the study was to develop and evaluate deep learning methods for predicting patient mechanics from standard gait lab data. The resulting models classified activities with excellent performance, and showed promise for predicting exact values for loading metrics for a range of different activities. These results indicate potential for real-time prediction of musculoskeletal metrics with application in patient diagnostics and rehabilitation. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 56 - 56
1 Dec 2022
Bishop E Kuntze G Clark M Ronsky J
Full Access

Individuals with multi-compartment knee osteoarthritis (KOA) frequently experience challenges in activities of daily living (ADL) such as stair ambulation. The Levitation “Tri-Compartment Offloader” (TCO) knee brace was designed to reduce pain in individuals with multicompartment KOA. This brace uses novel spring technology to reduce tibiofemoral and patellofemoral forces via reduced quadriceps forces. Information on brace utility during stair ambulation is limited. This study evaluated the effect of the TCO during stair descent in patients with multicompartment KOA by assessing knee flexion moments (KFM), quadriceps activity and pain. Nine participants (6 male, age 61.4±8.1 yrs; BMI 30.4±4.0 kg/m2) were tested following informed consent. Participants had medial tibiofemoral and patellofemoral OA (Kellgren-Lawrence grades two to four) diagnosed by an orthopaedic surgeon. Joint kinetics and muscle activity were evaluated during stair descent to compare three bracing conditions: 1) without brace (OFF); 2) brace in low power (LOW); and 3) brace in high power (HIGH). The brace spring engages from 60° to 120° and 15° to 120° knee flexion in LOW and HIGH, respectively. Individual brace size and fit were adjusted by a trained researcher. Participants performed three trials of step-over-step stair descent for each bracing condition. Three-dimensional kinematics were acquired using an 8-camera motion capture system. Forty-one spherical reflective markers were attached to the skin (on each leg and pelvis segment) and 8 markers on the brace. Ground reaction forces and surface EMG from the vastus medialis (VM) and vastus lateralis (VL) were collected for the braced leg. Participants rated knee pain intensity performing the task following each bracing condition on a 10cm Visual Analog Scale ranging from “no pain” (0) to “worst imaginable pain” (100). Resultant brace and knee flexion angles and KFM were analysed during stair contact for the braced leg. The brace moment was determined using brace torque-angle curves and was subtracted from the calculated KFM. Resultant moments were normalized to bodyweight and height. Peak KFMs were calculated for the loading response (Peak1) and push-off (Peak2) phases of support. EMG signals were normalized and analysed during stair contact using wavelet analysis. Signal intensities were summed across wavelets and time to determine muscle power. Results were averaged across all 3 trials for each participant. Paired T-tests were used to determine differences between bracing conditions with a Bonferroni adjustment for multiple comparisons (α=0.025). Peak KFM was significantly lower compared to OFF with the brace worn in HIGH during the push-off phase (p Table 1: Average peak knee flexion moments, quadriceps muscle power and knee pain during stair descent in 3 brace conditions (n=9). Quadriceps activity, knee flexion moments and pain were significantly reduced with TCO brace wear during stair descent in KOA patients. These findings suggest that the TCO assists the quadriceps to reduce KFM and knee pain during stair descent. This is the first biomechanical evidence to support use of the TCO to reduce pain during an ADL that produces especially high knee forces and flexion moments. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 43 - 43
1 Feb 2020
Knowles N Kusins J Faieghi M Ryan M Dall'Ara E Ferreira L
Full Access

Introduction. Subject-specific finite element models (FEMs) allow for a variety of biomechanical conditions to be tested in a highly repeatable manner. Accuracy of FEMs is improved by mapping density using quantitative computed tomography (QCT) and choosing a constitutive relationship relating density and mechanical properties of bone. Although QCT-derived FEMs have become common practice in contemporary computational studies of whole bones, many density-modulus relationships used at the whole bone level were derived using mechanical loading of small trabecular or cortical bone cores. These cores were mechanically loaded to derive an apparent modulus, which is related to each core's mean apparent or ash density. This study used these relationships and either elemental or nodal material mapping strategies to elucidate optimal methods for scapular QCT-FEMs. Methods. Six cadaveric scapulae (3 male; 3 female; mean age: 68±10 years) were loaded within a micro-CT in a custom CT-compatible hexapod robot Pre- and post-loaded scans were acquired (spatial resolution = 33.5 µm) and DVC was used to quantify experimental full-field displacements (BoneDVC, Insigneo) (Figure 1).. Experimental reaction forces applied to the scapulae were measured using a 6-DOF load cell. FEMs were derived from corresponding QCT scans of each cadaver bone. These models were mapped with one of fifteen density-modulus relationships and elemental or nodal material mapping strategies. DVC-derived BCs were imposed on the QCT-FEMs using local displacement measurements obtained from the DVC algorithm. Comparisons between the empirical and computational models were performed using resultant reaction loads and full-field displacements (Figure 2). Results and Discussion. Reaction forces predicted by the QCT-FEMs showed large percentage error variations across all specimens and density-modulus relationships with elemental material mapping. The percentage errors were as large as 899%, but as low as 3=57% for the different specimens. Similarly, when using a nodal material mapping strategy, percentage errors were as large as 965%, but as low as 4=59% for the different specimens (Figure 3). For all specimens, minimal variation only occurred in the slope between the QCT-FEM and DVC displacements in the x and y directions for either elemental or nodal material mapping strategies. Slopes ranged from 0.86 to 1.06. This held true for 3 specimens in the z direction; however, for the remaining 3 specimens more pronounced variations occurred between the QCT-FEM and DVC displacements, dependent on density-modulus relationship. The r. 2. values were consistently between 0.82 and 1.00 for both material mapping strategies and density-modulus relationships for all three Cartesian components of displacement and all specimens. Conclusions. The results suggest that QCT-FEMs using DVC derived boundary conditions can replicate experimental loading of cadaveric specimens. It was also shown that only slight variations exist when either elemental or nodal material mapping strategies are adopted. Given the recent advancements provided by DVC-derived BCs, this study provides a basis for a common methodology that can be implemented in future studies comparing similar outcomes in all anatomic locations. Expanding the current sample size has the potential to determine if a single density-modulus relationship can exist or if specimen or anatomic location-specific relationships should be utilized. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 23 - 23
1 Apr 2018
Zeller I Dessinger G Sharma A Fehring T Komistek R
Full Access

Background. Previous in vivo fluoroscopic studies have documented that subjects having a PS TKA experience a more posterior condylar contact position at full extension, a high incidence of reverse axial rotation and mid flexion instability. More recently, a PS TKA was designed with a Gradually Reducing Radius (Gradius) curved condylar geometry to offer patients greater mid flexion stability while reducing the incidence of reverse axial rotation and maintaining posterior condylar rollback. Therefore, the objective of this study was to assess the in vivo kinematics for subjects implanted with a Gradius curved condylar geometry to determine if these subjects experience an advantage over previously designed TKA. Methods. In vivo kinematics for 30 clinically successful patients all having a Gradius designed PS fixed bearing TKA with a symmetric tibia were assessed using mobile fluoroscopy. All of the subjects were scored to be clinically successful. In vivo kinematics were determined using a 3D-2D registration during three weight-bearing activities: deep-knee-bend (DKB), gait, and ramp down (RD). Flexion measurements were recorded using a digital goniometer while ground reaction forces were collected using a force plate as well. The subjects then assessed for range of motion, condyle translation and axial rotation and ground reaction forces. Results. During a DKB, subjects implanted a Gradius designed, PS fixed bearing TKA design exhibited an average of 3.35 mm of posterior femoral rollback of the lateral condyle and 2.73 mm of the medial condyle with an average axial rotation of 4.90° in the first 90° of flexion. The average max flexion was 111.4°. From full extension to maximum flexion, the average axial rotation was 4.73°, while the subjects experienced 5.34 and 1.97 mm on the lateral and medial condyle rollback, respectively. During mid flexion from 30 to 60 degrees of flexion, the subjects experienced 1.34° of axial rotation, −1.13 and −0.11 mm of lateral and medial condyle motion. Conclusions. Subjects in this study did experience good weight-bearing flexion and magnitudes of axial rotation and posterior femoral rollback similar to previous PS TKA designs. During mid flexion, subjects in this study did experience less mid flexion paradoxical sliding than other PS TKA, leading to greater mid flexion stability for the patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 3 - 3
1 Sep 2012
Galibaro P Al-Munajjed A Dendorfer S Toerholm S Rasmussen J
Full Access

INTRODUCTION. Several clinical studies demonstrated long-term adjacent-level effects after implantation of spinal fusion devices[1]. These effects have been reported as adjacent joint degeneration and the development of new symptoms correlating with adjacent segment degeneration[2] and the trend has therefore gone to motion preservation devices; however, these effects have not been understood very well and have not been investigated thoroughly[3]. The aim of this study is to investigate the effect of varying the stiffness of spinal fusion devices on the adjacent vertebral levels. Disc forces, moments and facet joint forces were analyzed. METHODS. The AnyBody Modeling System was used to compute the in-vivo muscle and joint reaction forces of a musculoskeletal model. The full body model used in this study consists of 188 muscle fascicles in the lumbar spine and more than 1000 individual muscle branches in total. The model has been proposed by de Zee et al.[3], validated by Rasmussen et al.[4] and by Galibarov et al.[5]. The new model[5] determines the individual motions between vertebrae based on the equilibrium between forces acting on the vertebrae from muscles and joints and the passive stiffness in disks and ligaments, figure 1a. An adult of 1.75 m and 75 kg with a spinal implant in L4L5 was modeled. This model was subjected to a flexion-extension motion using different elastic moduli to analyze and compare to a non-implanted scenario. The analyzed variables were vertebral motion, the disc reaction forces and moments, as well as facet joint forces in the treated and the adjacent levels: L2L3, L3L4, L4L5 and L5-Sacrum. RESULTS. When introducing a spinal fusion device in the L4L5 joint the reaction forces and moments decreased in this joint with stiffer devices leading to lower joint loads. However, in the adjacent joints, L3L4 and L5Sacrum, an increase was observed when implanting stiffer devices. Similar trends could be found for the L2L3 joint. The loads in the facet joints showed the same trends. While introducing a spinal fusion device reduced the facet joint forces in the treated joint, the loads in the adjacent facet joints were increased according to the stiffness of the implanted device, figure 1b. DISCUSSION. While the treated disc joint showed reduced motion and loads, the adjacent levels demonstrated a significant increase. In particular, the increased facet joint forces in the adjacent levels can lead to adjacent level facet pain or accelerated facet joint degeneration. Introducing a device resulted in preventing facet contact and therefore facet joint loads, even using the device with the lowest stiffness. CONCLUSION. The presented model shows that clinical complications such as facet joint degeneration in adjacent levels after implantation of spinal fusion device are consistent with the change in the mechanical-stimulus distribution in the system


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 62 - 62
1 Apr 2018
Van Houcke J Galibarov P Allaert E Pattyn C Audenaert E
Full Access

Introduction. A deep squat (DS) is a challenging motion at the level of the hip joint generating substantial reaction forces (HJRF). As a closed chain exercise, it has great value in rehabilitation and muscle strengthening of hip and knee. During DS, the hip flexion angle approximates the functional range of hip motion risking femoroacetabular impingement in some morphologies. In-vivo HJRF measurements have been limited to instrumented implants in a limited number of older patients performing incomplete squats (< 50° hip flexion and < 80° knee flexion). On the other hand, total hip arthroplasty is being increasingly performed in a younger and higher demanding patient population. These patients clearly have a different kinetical profile with hip and knee flexion ranges going well over 100 degrees. Since measurements of HJRF with instrumented prostheses in healthy subjects would be ethically unfeasible, this study aims to report a personalised numerical solution based on inverse dynamics to calculate realistic in-silico HJRF values during DS. Material and methods. Thirty-five healthy males (18–25 years old) were prospectively recruited for motion and morphological analysis. DS motion capture (MoCap) acquisitions and MRI scans with gait lab marker positions were obtained. The AnyBody Modelling System (v6.1.1) was used to implement a novel personalisation workflow of the AnyMoCap template model. Bone geometries, semi-automatically segmented from MRI, and corresponding markers were incorporated into the template human model by an automated procedure. A state of-the-art TLEM 2.0 dataset, included in the Anybody Managed Model Repository (v2.0), was used in the template model. The subject-specific MoCap trials were processed to compute kinematics of DS, muscle and joint reaction forces in the entire body. Resulting hip joint loads were compared with in-vivo data from OrthoLoad dataset. Additionally, hip and knee joint angles were computed. Results. An average HJRF of 274%BW (251.5 – 297.9%BW; 95% confidence interval) was calculated at the peak of DS. The HJRF on the pelvis was directed superior, medial and posterior throughout the DS. Peak knee and hip flexion angles were 112° (108.1° – 116.5°) and 107° (104.6° – 109.4°) on average. Discussion and conclusions. A comprehensive approach to construct an accurate personalised musculoskeletal model from subject-specific MoCap data, bone geometries, and palpatory landmarks was presented. Consistently higher HJR forces during DS in young adults were demonstrated as opposed to the Orthoload dataset. Similarly, knee and hip flexion angles were much higher, which could cause the increase in HJRF. It can be concluded that DS kinetics in young adults differ from the typical total hip arthroplasty population. These models will enable further in-silico joint biomechanics studies, and could serve the purpose of a virtual test bed for implant design


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 9 - 9
1 Jun 2021
Greene A Verstraete M Roche C Conditt M Youderian A Parsons M Jones R Flurin P Wright T Zuckerman J
Full Access

INTRODUCTION. Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes. METHODS. Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests. RESULTS. No significant differences were observed for the flexion/extension maneuver between the 38mm and 42mm liner sizes, but a significant difference was observed for every internal/external rotation assessment at 0°, 45°, and 90° of abduction. No significant differences were observed for the across the body and overhead maneuvers, but a significant difference was observed for the behind the back maneuver (p = 0.015). Standard deviations were pronounced across all maneuvers. CONCLUSION. This study observed significant differences in intraoperative load values in rTSA when comparing different humeral liner sizes. Limitations of this study include the small sample sizes and large standard deviations observed, as well as comparing across multiple patients and multiple surgeons. Area for future work includes comparing load values with postoperative functional results and complication risks for short, midterm, and long-term outcomes in efforts to find the optimal load range for a given patient


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 108 - 108
1 May 2016
Verstraete M Herregodts S De Baets P Victor J
Full Access

Introduction. For the evaluation of new orthopaedic implants, cadaveric testing remains an attractive solution. However, prior to cadaveric testing, the performance of an implant can be evaluated using numerical simulations. These simulations can provide insight in the kinematics and contact forces associated with a specific implant design and/or positioning. Methods. Both a two and three dimensional simulation model have been created using the AnyBody Modelling System (AMS). In the two dimensional model, the knee joint is represented by a hinge. Similarly, the ankle and hip joint are represented by a hinge joint and a variable amplitude quadriceps force is applied to a rigid bar connected to the tibia (Figure 1a). In line with this simulation model, a hinge model was created that could be mounted in the UGent knee simulator to evaluate the performance of the simulated model. The hinge model thereby performs a cyclic motion under varying quadriceps load while recording the ankle reaction forces. In addition to the two dimensional model, a three dimensional model has been developed (Figure 1b). More specifically, a model is built of a sawbone leg holding a posterior stabilized single radius total knee implant. The physical sawbone model contains simplified medial and lateral collateral ligaments. In line with the boundary conditions of the UGent knee simulator, the simulated hip contains a single rotational degree of freedom and the ankle holds four degrees of freedom (three rotations, single translation). In the simulations, the knee is modelled using the force-dependent kinematics (FDK) method built in the AMS. This leaves the knee with six degrees of freedom that are controlled by the ligament tension in combination with the applied quadriceps load and shape of the implant. The physical sawbone model goes through five cycles in the UGent simulator using while recording the kinematics of the femur and tibia using a set of markers rigidly attached to the femur and tibia bone. The position of the implant with respect to the markers was evaluated by CT-scanning the sawbone model. Results and Discussion. In a first step, the reaction forces at the ankle in the 2D model were evaluated. The difference between the simulated and measured reaction force is limited and can be explained from a slight variation of the attachment point of the quadriceps load. For the 3D model, the kinematic patterns have been evaluated for both the simulation and physical model using Grood & Suntay definitions. The kinematic parameters display realistic trends, however, no exact match has been obtained for all parameters so far. The latter might be attributed to a number of simplifications in the simulation model as well as elastic deformation of the physical sawbone model. Conclusion. A three dimensional model of a knee implant in the UGent Knee Simulator has been developed. The simulated kinematic patterns appear realistic though no exact match with the measured patterns has been obtained. Future research will therefore focus on the development of a more realistic experimental and numerical model


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2013
Wiik A Tankard S Lewis A Krishnan S Amis A Cobb J
Full Access

Background. High functional aspirations and an active ageing population equate to a growing number of patients awaiting hip arthroplasty demanding superior biomechanical function. The purpose of this study was to compare the biomechanics of top walking speed between two commonly used hip arthroplasty procedures to determine if a performance advantage existed. Methods. A retrospective comparative study was performed using sixty-seven subjects, twenty-two subjects in both hip resurfacing and total hip arthroplasty groups along with twenty-three healthy controls. All arthroplasty subjects were recruited based on high psychometric scoring and had been performed through a posterior approach, and had been discharged from follow-up. On an instrumented treadmill each subject was measured by a researcher blinded to which procedure that patient had undergone. After a six minute acclimatization period, the speed was increased incrementally until top walking performance had been attained. At all increments, ground reaction forces and temporospatial measurements were collected. Results. The two arthroplasty groups were well matched demographically, with no significant differences with regards to age, sex, height, BMI and pre-operative radiological severity. Treadmill temporospatial analysis demonstrated significant differences between the two groups. The hip resurfacing group were able to walk statistically faster (p=0.023) with an increased step length(p=0.041). The top walking speed mean of 2.06m/sec by the resurfacing almost matched the healthy controls. Assessing ground reaction forces and symmetry also demonstrated hip resurfacing was superior (Graph 1). [Graph 1: Mean Gait Biomechanics at Top Speed]. Conclusion. This study is the first to focus on high end performance following hip arthroplasty, encouraging patients to achieve as high a speed as they comfortably could. The total hip arthroplasty group walked nine percent faster than the previously published top speed of 1.73m/sec, however the resurfacings still walked ten percent faster, matching the normal controls for speed and step length


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 14 - 14
1 Jul 2020
Young K Wilson JA Dunbar MJ Roy P Abidi S
Full Access

Identifying knee osteoarthritis (OA) patient phenotypes is relevant to assessing treatment efficacy, yet biomechanical variability has not been applied to phenotyping. This study aimed to identify demographic and gait related groups (clusters) among total knee arthroplasty (TKA) candidates, and examine inter-cluster differences in gait feature improvement post-TKA. Knee OA patients scheduled for TKA underwent three-dimensional gait analysis one-week pre and one-year post-TKA, capturing lower-limb external ground reaction forces and kinematics using a force platform and optoelectronic motion capture. Principal component analysis was applied to frontal and sagittal knee angle and moment waveforms (n=135 pre-TKA, n=106 post-TKA), resulting in a new uncorrelated dataset of subject PCscores and PC vectors, describing major modes of variability throughout one gait cycle (0–100%). Demographics (age, gender, body mass index (BMI), gait speed), and gait angle and moment PCscores were standardized and assessed for outliers. One patient exceeding Tukey's outer (3IQR) fence was removed. Two-dimensional multidimensional scaling followed by k-medoids clustering was applied to scaled demographics and pre-TKA PCscores [134×15]. Number of clusters (k=2:10) were assessed by silhouette coefficients, s, and stability by Adjusted Rand Indices (ARI) of 100 data subsets. Clusters were validated by examining inter-cluster differences at baseline, and inter-cluster gait changes (PostPCscore–PrePCscore, n=105) by k-way ANOVA and Tukey's honestly significant difference (HSD) criterion. Four (k=4) TKA candidate groups yielded optimum clustering metrics (s = 0.4, ARI=0.75). Cluster 1 was all-males (male:female=19:0) who walked with faster gait speeds (1>2,3), larger flexion angle magnitudes and stance-phase angle range (PC1 & PC4 1>2,3,4), and more flexion (PC2 1>2,3,4) and adduction moment (PC2 & PC3 1>2,3) range patterns. Cluster 1 had the most dynamic kinematics and kinetic loading/unloading range amongst the clusters, representing a higher-functioning (less “stiff”) male subset. Cluster 2 captured older (2>1,3) males (31:1) with slower gait speeds (2 4), and lower flexion angle magnitude (PC1 3 2,3) and less stiff kinematic and kinetic patterns relative to Clusters 2 and 3, representing a higher-functioning female subset. Radiographic severity did not differ between clusters (Kellgren-Lawrence Grade, p=0.9, n=102), and after removing demographics and re-clustering, gender differences remained (p < 0 .04). Pre-TKA, higher-functioning clusters (1&4) had more dynamic loading/un-loading kinetic patterns. Post-TKA, high-functioning clusters experienced less gait improvement (flexion angle PC2, 1,4 < 3, p≥0.004, flexion moment PC2, 4 < 2,3), with some sagittal range patterns decreasing postoperatively. TKA candidates can be characterized by four clusters, differing by demographics and biomechanical severity features. Post-TKA, functional gains were cluster-specific, stiff-gait clusters experienced more improvement, while higher-functioning clusters experienced less gain and showed some decline. Results suggest the presence of cohorts who may not benefit functionally from TKA. Cluster profiling may support triaging and developing targeted OA treatment strategies, meeting individual function needs


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 109 - 109
1 Jul 2020
Kowalski E Lamontagne M Catelli D Beaulé P
Full Access

The literature indicates that femoroacetabular impingement (FAI) patients do not return to the level of controls (CTRL) following surgery. The purpose of this study was to compare hip biomechanics during stair climbing tasks in FAI patients before and two years after undergoing corrective surgery against healthy controls (CTRL). A total of 27 participants were included in this study. All participants underwent CT imaging at the local hospital, followed by three-dimensional motion analysis done at the human motion biomechanics laboratory at the local university. Participants who presented a cam deformity >50.5° in the oblique-axial or >60° in the radial planes, respectively, and who had a positive impingement test were placed in the FAI group (n=11, age=34.1±7.4 years, BMI=25.4±2.7 kg/m2). The remaining participants had no cam deformity and negative impingement test and were placed in the CTRL group (n=16, age=33.2±6.4 years, BMI=26.3±3.2 kg/m2). The CTRL group completed the biomechanics protocol once, whereas the FAI group completed the protocol twice, once prior to undergoing corrective surgery for the cam FAI, and the second time at approximately two years following surgery. At the human motion biomechanics laboratory, participants were outfitted with 45 retroreflective markers placed according to the UOMAM marker set. Participants completed five trials of stairs task on a three step instrumented stair case to measure ground reaction forces while 10 Vicon MX-13 cameras recorded the marker trajectories. Data was processed using Nexus software and divided into stair ascent and stair descent tasks. The trials were imported into custom written MatLab software to extract peak pelvis and hip kinematics and hip kinetic variables. Non-parametric Kruskal-Wallis tests were used to determine significant (p < 0.05) differences between the groups. No significant differences occurred during the stair descent task between any of the groups. During the stair ascent task, the CTRL group had significantly greater peak hip flexion angle (Pre-Op=58±7.1°, Post-Op=58.1±6.6°, CTRL=64.1±5.1°) and sagittal hip range of motion (ROM) (Pre-Op=56.7±6.7°, Post-Op=56.3±5.5°, CTRL=61.7±4.2°) than both the pre- and post-operative groups. Pre-operatively, the FAI group had significantly less peak hip adduction angle (Pre-Op=2±4.5°, Post-Op=3.4±4.4°, CTRL=5.5±3.7°) and hip frontal ROM (Pre-Op=9.9±3.4°, Post-Op=11.9±5.4°, CTRL=13.4±2.5°) compared to the CTRL group. No significant differences occurred in the kinetic variables. Our findings are in line with the Rylander and colleagues (2013) who also found that hip sagittal ROM did not improve following corrective surgery. Their study included a mix of cam and pincer-type FAI, and had a mean follow-up of approximately one year. Our cohort included only cam FAI and they had a mean follow-up of approximately two years, indicating with the extra year, the patients still did not show sagittal hip kinematics improvement. In the frontal plane, there was no significant difference between the post-op and the CTRL, indicating that the postoperative FAI reached the level of the CTRLs. This is in line with recent work that indicates a more medialized hip contact force vector following surgery, suggesting better hip stabilization


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 10 - 10
1 May 2018
Monk P Boyd R Brown C Gibbons M Alvand A Price A
Full Access

The optimal correction of the weight bearing line during High Tibial Osteotomy has not been determined. We used finite element modelling to simulate the effect that increasing opening wedge HTO has on the distribution of stress and pressure through the knee joint during normal gait. Subject-specific models were developed by combining geometry from 7T MRI scans and applied joint loads from ground reaction forces measured during level walking. Baseline stresses and pressures on the articulating proximal tibial cartilage and menisci were calculated. Progressive osteotomies were then simulated to shift the weight-bearing line from the native alignment towards/into the lateral compartment (between 40 – 80% of medial-lateral tibial width). Changes in calculated stresses and pressures were recorded. Both stress and pressure decreased in the medial compartment and increased in the lateral compartment as increasingly valgus osteotomies were simulated. The models demonstrated a consistent “safe zone” for weight bearing line position at 50%-65% medial-lateral tibial width, outside of which compartment stresses and pressures substantial increased. This study suggests a safe correction zone within which a medial opening wedge HTO can be performed correcting the WBL to 55% medio-lateral width of the tibia


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 28 - 28
1 Dec 2016
Parvizi J
Full Access

There are a number of progressive conditions that afflict the hip and result in degenerative arthritis. Along the path of progression of the disease and prior to the development of arthritis, some of these conditions may be treatable by joint preservation procedures. Periacetabular osteotomy for developmental dysplasia of the hip (DDH), femoroacetabular osteoplasty for femoroacetabular impingement (FAI), and a variety of surgical procedures for management of early osteonecrosis of the femoral head are some examples of joint preservation of the hip. DDH is characterised by abnormal development of the acetabulum and the proximal femur that leads to suboptimal contact of the articular surfaces and the resultant increase in joint reaction forces. FAI is a condition characterised by an abnormal contact between the femoral neck and the acetabular rim. FAI is believed to exist when a triad of signs (abnormal alpha angle, labral tear, and chondral lesion) can be identified. The question that remains is whether joint preservation procedures are able to avert the need for arthroplasty or just an intervention along the natural path of progression of the hip disease. There is an interesting study that followed 628 infants born in a Navajo reservation, including 8 infants with severe dysplasia, for 35 years. None of the children with DDH had surgical treatment and all had developed severe arthritis in the interim. The latter study and a few other natural history studies have shown that the lack of administration of surgical treatment to patients with symptomatic DDH results in accelerated arthritis. The situation is not so clear with FAI. Some believe that FAI is a pre-arthritic condition and surgical treatment is only effective in addressing the symptoms and does not delay or defer an arthroplasty. While others believe that restoration of the normal mechanical environment to the hip of FAI patients, by removing the abnormal contact and repair of the labrum, is likely to change the natural history of the disease and at minimum delay the need for an arthroplasty. There is a need for natural history studies or case series to settle the latter controversy


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 32 - 32
1 Apr 2017
Duncan C
Full Access

There has been a reluctance, until relatively recently, to consider replacement of the hip in patients with substantial neuromuscular imbalance. This relates to many factors, including the young age of many (such as cerebral palsy in the older teen and young adult), developmental anatomic abnormality, oft-present poor bone health, neuromuscular imbalance, and the risk of complication; especially dislocation. Mental retardation also introduces challenges with rehabilitation and an increased burden on the family and societal support systems if the outcome is to be maximised. With the development of newer techniques and technology, and the emergence of encouraging outcome studies, these patients can be more easily offered predictable relief of pain, a reasonable chance of improved function, longevity of the reconstruction, and an acceptable risk of complication. A large number of background neurological diagnoses can lead to hip degeneration, or can introduce increased complexity during management of hip degeneration unrelated to that background. Be that as it may, a short list of fundamental questions is common to all and will help guide management:. Important questions to be addressed include:. 1. Did the NV imbalance precede skeletal development? This relates to the dependence of skeletal shape and size on the loads being placed upon it: hence “Form Follows Function”. The shape and size of the hip, and location of the femoral head, will be much different in the young adult with spastic dislocation due to cerebral palsy, when compared with the elderly adult with a late onset CVA-related spasticity superimposed on hip degeneration. 2. Is the muscle tone which will support the hip arthroplasty predominantly spastic or flaccid? In each there is a risk of dislocation, which needs to be addressed at the index procedure, but in spasticity there is the added question as to what tissues need to be released or de-functioned so as to alter the magnitude and direction of the joint reaction forces. 3. Is pain the main reason for consultation? Because pain relief is the most predictable outcome that we can offer, it should guide the indications and timing of intervention. Replacement of the NM hip to improve function, in the absence of pain, should be approached with great caution


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 22 - 22
1 Feb 2017
Huff D Schwartz B Fitzpatrick C Rullkoetter P
Full Access

INTRODUCTION. Within total hip replacement, articulation of the femoral head near the rim of the acetabular liner creates undesirable conditions leading to a propensity for dislocation[1], increased contact stresses[2], increased load and torque imparted on the acetabular component[3], and increased wear[4]. Propensity for rim loading is affected by prosthesis placement, as well as the kinematics and loading of the patient. The present study investigates these effects. METHODS. CT scans from an average-sized patientwere segmented for the hemipelvis and femur of interest. DePuy Synthes implant models were aligned in a neutral position in Hypermesh. The acetabular liner was assigned deformable solid material properties, and the remainder of the model was assigned rigid properties. Joint reaction forces and kinematics of hip flexion were taken from the public Orthoload database to represent ADLs [5]: Active flexion lying on a table, gait, bending to lift and move a load, and sit-stand. The pelvis was fully constrained, while three-degree-of-freedom (3-DOF) forces were applied to the femur. Hip flexion was kinematically-prescribed while internal-external (I-E) and adduction-abduction (Ad-Ab) DOFs were constrained. Angles of acetabular implant positioning were based on published data by Rathod [6]. Femoral implant position was chosen based on cadaveric in vitro DePuy Synthes measurements of variation in femoral prosthesis position reported previously [7]. Acetabular and Femoral alignment angles were represented for nominal position, as well as positioning + 1σ and + 2σ from the mean in both anteversion and inclination for acetabular components, and both Varus/Valgus and Flexion (angle in sagittal plane) for the femoral component. The analyses were automated within Matlab to execute 68 finite element analyses in Abaqus Explicit and structured in a DOE style analysis with Cup inclination, Cup version, Stem Flexion, and Stem Varus/Valgus, and Activity as variables of interest (64 runs + 4 centerpoints = 68 analyses). From a previous study it was known that acetabular component inclination had the greatest effect on contact pressure location [7], so all data were analyzed relative to inclination, allowing other positioning variables to be represented as variation per inclination position. Results are presented as a percentage, with 0% being pole loading and 100% being rim loading, to normalize for head diameter. RESULTS. As expected, higher cup inclination generally resulted in higher propensity for rim loading. The degree to which this is true, however, is very dependent upon activity. The bent forward, liftweight activity, for example, resulted in relatively less change in center of pressure distance from the apex of the liner (COPtA) with increased inclination. Still other activities, such as Flexion, showed to be more affected by variation in Cup version, Stem Flexion, and Stem Varus/Valgus for a given inclination angle, as shown by larger variation in results. CONCLUSION. This study generally supports acetabular prosthesis inclination angle as an important variable for the study of rim loading in THA. However, it also highlights the importance of including variation in implant placement, as well as loading conditions in such evaluations


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 45 - 45
1 Mar 2017
Myers C Laz P Shelburne K Rullkoetter P
Full Access

Introduction. Alignment of the acetabular cup and femoral components directly affects hip joint loading and potential for impingement and dislocation following total hip arthroplasty (THA) [1]. Changes to the lines of action and moment generating capabilities of the muscles as a result of component position may influence overall patient function. The objectives of this study were to assess the effect of component placement on hip joint contact forces (JCFs) and muscle forces during a high demand step down task and to identify important alignment parameters using a probabilistic approach. Methods. Three patients following THA (2 M: 28.3±2.8 BMI; 1 F: 25.7 BMI) performed lower extremity maximum isometric strength tests and a step down task as part of a larger IRB-approved study. Patient-specific musculoskeletal models were created by scaling a model with detailed hip musculature [2] to patient segment dimensions and mass. For each model, muscle maximum isometric strengths were optimized to minimize differences between model-predicted and measured preoperative maximum isometric joint torques at the hip and knee. Baseline simulations used patient-specific models with corresponding measured kinematics and ground reaction forces to predict hip JCFs and muscle forces using static optimization. To assess the combined effects of stem and cup position and orientation, a 1000 trial Monte Carlo simulation was performed with input variability in each degree of freedom based on the ±1 SD range in component placement relative to native geometry reported by Tsai et al. [3] (Figure 1). Maximum confidence bounds (1–99%) were predicted for the hip JCF magnitude and muscle forces for three prime muscles involved in the task (gluteus medius, gluteus minimus and psoas). HJC confidence bounds were compared to Orthoload measurements from telemetric implants from 6 patients performing the step down task. Sensitivity of hip JCF and muscle force outputs was quantified by Pearson Product-Moment correlation between the input parameter and the value of each output averaged across four points in the cycle. Results. Variation in the placement of the stem and cup produced an average maximum confidence bound (1–99%) in hip JCF of 277.7±91.1N and forces of 259.4±58.3N in the gluteus medius for all three patients (Figure 2). Sensitivity to cup and stem placement varied among the three patients; however, in general, hip JCFs were more sensitive to the position of the stem than the cup (Figure 3). Hip JCF was most sensitive to stem anteversion (0.64±0.10) and the superior/inferior stem position (0.42±0.19). Discussion. Variation in stem anteversion and medial/lateral cup position contributed the largest amount of variability in hip JCF and muscle forces during a step down task. The probabilistic analysis characterized bounds for output parameters, considering interactions between alignment parameters. Alignments that avoid increases in JCF and muscle loading during high demand tasks may lead to earlier recovery of function, by reducing muscle fatigue and the need to develop compensatory movement patterns. Acknowledgements. This research was supported in part by DePuy-Synthes


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 26 - 26
1 May 2016
Mauck J Kebbach M Schulze C Bader R Kluess D
Full Access

Introduction. The influence of the bone mineral density (BMD) on the mechanical behavior of bones can be examined using computer tomography (CT) data and finite element (FE) simulations, because the BMD correlates with the Hounsfield scale (HU) of the CT data. Therefor the material mapping strategy, which is required to assign the HU values to the FE mesh, is of crucial importance. In this study a nodal mapping strategy was analyzed concerning its sensitivity towards FE mesh parameters and an averaging of HU values from the area around the respective nodes. Method. The FE simulation is based on CT data of a human proximal femur. Once the bone shape was reconstructed, the resulting model was meshed with quadratic tetrahedral elements in ABAQUS/CAE and all nodes were assigned an HU value from the CT data by using the respective node coordinates. In this process, the mesh density, the threshold, which could be used to exclude connective tissue and fat from the material mapping process, the considered volume around the nodes and the method of averaging were varied. The material assignment was realized by an HU value dependent, linear elastic material definition. The femur model was clamped at the level of the isthmus and a displacement of 0.5 mm was applied at the femoral head. The evaluation was based on the resulting reaction forces. Results. The sensitivity analysis demonstrated, that threshold and mesh density mainly influenced the reaction force [Fig. 1]. If a threshold was applied, the reaction force increased by about 20 % in average. A threefold increase of the mesh density led to an average gain of the results of about 24 %. For a specific mesh density the curve progressions of the respective results intersected, i.e. an alteration of the considered volume or the method of averaging barely affected the reaction force [Fig. 2, Fig. 3]. Apart from this intersection, the comparison of the small and the large average volume led to a deviation of up to 11 %. On the other hand, the examination of different methods of averaging revealed only a maximum deviation of 4 % between “mean” and “median”. Discussion. The present study indicates, that the material mapping strategy is an influential part of the modeling process, which should be validated to avoid misjudgments of the load situation. Accordingly, the use of a threshold to exclude non-bone tissue could be a helpful tool. But with the exclusion of lower HU values, the load-bearing structure gains stiffness and the reaction force in the femur rises. A finer mesh leads to a higher resolution of the bone structure and, therefore, to a higher accuracy of the results. The “equilibrium” between the different models at the intersection is caused by a more homogeneous distribution of the material property which is increased by a larger considered volume and the method “mean”


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 114 - 114
1 Feb 2017
Favre P King E Palmer M Eldemerdash A Bischoff J Lawton J
Full Access

INTRODUCTION. Aseptic loosening is the most common failure mode for Total Elbow Arthroplasty (TEA) and is considered to be associated with accelerated polyethylene bearing wear [1, 2]. This study aimed to evaluate three commercially available implant designs under loads associated with daily living. The hypothesis was that more recent designs (Discovery and Nexel) provide greater articular contact areas resulting in lower polyethylene stresses compared to the Coonrad/Morrey (CM). METHODS. Motion tracking was performed on a healthy volunteer during elbow flexion at 0, 45, and 90° shoulder abduction because most daily activities occur with some shoulder abduction [3] resulting in varus stress about the elbow. This kinematic data was used in an OpenSim upper extremity musculoskeletal model [4] to estimate muscle and joint reaction loads with 5lb in hand, consistent with the common clinical restrictions following TEA. Computer aided assemblies of the smallest size implants for each system were imported to ANSYS for finite element analysis. Metallic components were treated as rigid and polyethylene components were modeled using a nonlinear elastoplastic constitutive model calibrated to material data. Articular contacts were frictional. Physiologic joint reaction forces and moments quantified in OpenSim were applied and the resulting peak articular contact area and peak bearing von Mises stresses were assessed. RESULTS. Simulated deformation patterns of CM bearings corresponded well to those reported in retrievals studies [1, 2] supporting the clinical relevance of the modeling approach. Peak stresses for CM and Nexel were consistently found in the central and side bearings respectively. The central bearing stresses remained 2–2.6 times lower in Nexel compared to CM. Peak stress for all three TEA systems increased with shoulder abduction (Fig.1, 2). Highest peak stresses (Fig.2) were obtained in CM and consistently exceeded the polyethylene yield limit; CM showed the lowest contact area (Fig.3). Nexel and Discovery experienced peak polyethylene stresses 26–34% and 17–39% lower than CM respectively (Fig.2). DISCUSSION. Our results support the hypothesis that newer TEA systems provide increased articular contact area and reduced bearing stresses during physiological loading. The cylindrical CM central bearing carries both the joint reaction force and moment leading to edge loading and high stresses (Fig.1). The design of the Nexel central bearing provides limited resistance to varus-valgus moment, thus transferring the moment to the side bearings and reducing central bearing stresses. The hemispherical Discovery bearing design was confirmed to offer a large articular contact area. However, non-concentricity of the contact spheres can lead to edge loading and high polyethylene stresses under off-axis forces. CM and Discovery utilize conventional polyethylene, whereas Nexel utilizes highly cross-linked Vitamin-E polyethylene. This study does not account for the increased wear resistance of Vitamin-E as compared to conventional polyethylene [5]. Long term clinical data are needed to demonstrate how these wear properties, as well as the geometric design which has been shown to impact stresses and contact patterns, translate to in vivo performance. For figures, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 76 - 76
1 Feb 2017
Cobb J Wiik A Brevadt MJ Auvinet E Van Der Straeten C
Full Access

Intro. Across much of medicine, activity levels predict life expectancy, with low levels of activity being associated with increased mortality, and higher levels of activity being associated with longer healthier lives. Resurfacing is a technically demanding procedure that has suffered significant fallout from the failure of a couple of poorly performing designs. However strong evidence associates resurfacing with improved life expectancy in both the short and longer term following surgery. We wondered if there was any relationship between the function of hips following surgery and the extent of that surgery. Could a longer stem inside the femur be the reason for a slightly reduced step length? We proposed the nul hypothesis that there was no clinically relevant difference between stem length and gait. Method. After informed consent each subject was allowed a 5 minute acclimatisation period at 4km/hr on the instrumented treadmill (Kistler Gaitway, Amherst, NY). Their gait performance on an increasing incline at 5, 10 and 15%. At all 0.5km incremental intervals of speed, the vertical component of the ground reaction forces, center of pressure and temporal measurements were collected for both limbs with a sampling frequency of 100Hz over 10sec. They were also asked to log onto our JointPRO website and report their function using Oxford, EQ5D, and Imperial scores. Owing to current restrictions in indications, the patient groups selected were not comparable. However, from our database of over 800 patients who have been through the gait lab. 82 subjects were tested from 2 diagnostic groups (29 conventional THR, 27 hip resurfacing) and compared with a slightly younger group of 26 healthy controls. Patients were excluded if less than 12 months postop, or with any other documented joint disease or medical comorbidities which might affect gait performance. Body weight scaling was also applied to the outputted mechanical data to correct for mass differences. All variables for each subject group were compared to each other using an analysis of variance (ANOVA) with Tukey post hoc test with significance set at α=0.05. Results. The experimental groups were reasonably matched for sex, height and BMI, although the controls were rather younger, and the hip replacements rather older (young hip resurfacings were excluded for lack of good controls). Any differences did not reach significance. Oxford hip scores and EQ5D were almost identical for the two experimental groups. The THR group walked 10% slower than control (1.8 (±0.2)m/sec vs 2.0 (±0.1)m/sec). while the HRA group walked 5% faster (2.1(±0.2)m/sec). The difference between THR and control was significant (p<0.05). (See Figure 1). Discussion. This data records a 15% difference in top walking speed between THR and HRA, far exceeding the 5% threshold of clinical relevance. We therefore consider this improved functional outcome to be clinically relevant, and report with increasing confidence that hip resurfacings is an effective intervention in the treatment of hip disease with clinically relevant superiority over THR, even in a group with an average age of 60