We aim to analyze the role of patient-related factors on the yield of progenitor cells in the bone marrow aspiration concentrate (BMAC). We performed a
Mechanical failure of spine posterior fixation in the lumbar region Is suspected to occur more frequently when the sagittal balance is not properly restored. While failures at the proximal extremity have been studied in the literature, the lumbar distal junctional pathology has received less attention. The aim of this work was to investigate if the spinopelvic parameters, which characterize the sagittal balance, could predict the mechanical failure of the posterior fixation in the distal lumbar region. All the spine surgeries performed in 2017-2019 at Rizzoli Institute were retrospectively analysed to extract all cases of lumbar distal junctional pathology. All the revision surgeries performed due to the pedicle screws pull-out, or the breakage of rods or screws, or the vertebral fracture, or the degenerative disc disease, in the distal extremity, were included in the junctional (JUNCT) group. A total of 83 cases were identified as JUNCT group. All the 241 fixation surgeries which to date have not failed were included in the control (CONTROL) group. Clinical data were extracted from both groups, and the main spinopelvic parameters were assessed from sagittal standing preoperative (pre-op) and postoperative (post-op) radiographs with the software Surgimap (Nemaris). In particular, In JUNCT, the main failure cause was the screws pull-out (45%). Spine fixation with 7 or more levels were the most common in JUNCT (52%) in contrast to CONTROL (14%). In CONTROL, PT, TPA, SS and PI-LL were inside the recommended ranges of good sagittal balance. For these parameters, statistically significant differences were observed between pre-op and post-op (p<0.0001, p=0.01, p<0.0001, p=0.004, respectively, These results showed that failure is most common in long fused segments, likely due to long lever arms leading to implant failure. If the sagittal balance is not properly restored, after the surgery the balance is expected to worsen, eventually leading to failure: this effect was confirmed by the worsening of all the spinopelvic parameters before the revision surgery in JUNCT. Conversely, a good sagittal balance seems to avoid a revision surgery, as it is visible is CONTROL. The mismatch PI-LL after the fixation seems to confirm a good sagittal balance and predict a good correction. The linear regression of PT vs PI suggests that the spine deformity and pelvic conformation could be a predictor for the failure after a fixation.
Chordoma of the cervical spine is a rare but life-threatening disease with a relentless tendency towards local recurrence. Wide en bloc resection is recommended, but it is frequently not feasible in the cervical spine. Radiation therapy including high-energy particle therapy is commonly used as adjuvant therapy. The goal of this study was to examine treatment and outcome of patients with chordoma of the cervical spine. Patients affected by cervical spine chordoma who underwent surgery at the Rizzoli Institute and University Hospital of Modena, between 2007 and 2021 were identified. The clinical, pathologic, and radiographic data were reviewed in all cases. Patient outcomes including local recurrence and disease-specific survival (DSS) were analyzed using chi-square test and Kaplan-Meier survival analysis. Characteristics of the 29 patients (10 females; 19 males) included: median age at surgery 52.0 years (IQR 35.5 - 62.5 years), 10 (35%) involved upper cervical spine, 16 (55%) with tumors in the mid cervical spine, and 4 in the lower cervical spine (10%). Median tumor volume was 16 cm3 (IQR 8.7 - 20.8). Thirteen patients (45%) were previously treated surgically while 9 patients (31%) had previous radiation therapy. All patients underwent surgery: en bloc resection was passible in 4 patients (14 %), seventeen patients (59%) were treated with gross total resection while 8 patients (27%) underwent subtotal resection. Tumor volume was associated with a significantly higher risk of intraoperative complications (p < 0.01). Nineteen patients (65%) received adjuvant high-energy particle therapy. The median follow-up was 26 months (IQR 11 - 44). Twelve patients (41%) had local recurrence of disease. Patients treated with adjuvant high-energy particle therapy had a significant higher local control than patients who received photons or no adjuvant treatment (p = 0.01). Recurrence was the only factor significantly associated with worse DSS (p = 0.03 – OR 1.7), being the survival of the group of patients with recurrent disease 58.3% while the survival of the group of patients with no recurrent disease was 100%. Post-operative high-energy particle therapy improved local control in patients with cervical chordoma after surgical resection. Increased tumor volume was associated with increased risk of intraoperative complications. Recurrence of the disease was the only factor significantly associated with disease mortality.
Up to 20% of patients can remain dissatisfied following TKR. A proportion of TKRs will need early revision with aseptic loosening the most common. The ATTUNE TKR was introduced in 2011 as successor to its predicate design The PFC Sigma (DePuy Synthes, Warsaw, In). However, following reports of early failures of the tibial component there have been ongoing concerns of increased loosening rates with the ATTUNE TKR. In 2017 a redesigned tibial baseplate (S+) was introduced, which included cement pockets and an increased surface roughness to improve cement bonding. Given the concerns of early tibial loosening with the ATTUNE knee system, this study aimed to compare revision rates and those specific to aseptic loosening of the ATTUNE implant in comparison to an established predicate as well as other implant designs used in a high-volume arthroplasty centre. The Attune TKR was introduced to our unit in December 2011. Prior to this we routinely used a predicate design with an excellent long-term track record (PFC Sigma) which remains in use. In addition, other designs were available and used as per surgeon preference. Using a prospectively maintained database, we identified 10,202 patients who underwent primary cemented TKR at our institution between 01/04/2003–31/03/2022 with a minimum of 1 year follow-up (Mean 8.4years, range 1–20years): 1) 2406 with ATTUNE TKR (of which 557 were S+) 2) 4652 with PFC TKR 3) 3154 with other cemented designs. All implants were cemented using high viscosity cement. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Matched cohorts were selected from the ATTUNE subsets (original and S+) and PFC groups using the nearest neighbor method for radiographic analysis. Radiographs were assessed to compare the presence of radiolucent lines in the Attune S+, standard Attune, and PFC implants.Abstract
Objective
Methods
Objectives. Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years. Methods. A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)). Results. The incidence of cut-out across the sample was 5.6%, with a higher incidence in female patients. A significantly higher risk of this complication was correlated with lag-screw tip positioning in the upper part of the femoral head in the anteroposterior radiological view, posterior in the latero-lateral radiological view, and in the Cleveland peripheral zones. The tip-apex distance and the calcar-referenced tip-apex distance were found to be highly significant predictors of the risk of cut-out at cut-offs of 30.7 mm and 37.3 mm, respectively, but the former appeared more reliable than the latter in predicting the occurrence of this complication. Conclusion. The tip-apex distance remains the most accurate predictor of cut-out, which is significantly greater above a cut-off of 30.7 mm. Cite this article: G. Caruso, M. Bonomo, G. Valpiani, G. Salvatori, A. Gildone, V. Lorusso, L. Massari. A six-year
There has been significant interest in day-case and rapid discharge pathways for unicompartmental knee replacements (UKR). Pathways to date have shown this to be a safe and feasible option; however, no studies to date have published results of rapid-discharge pathways using the NAVIO robotic system. To date there is no published experience with rapid discharge UKR patients using the NAVIO robotic system. We report an initial experience of 11 patients who have safely been discharged within 24 hours. With the primary goal of investigating factors that led to rapid discharge and a secondary goal of evaluating the safety of doing so. All patients were discharged within 24 hours; there were no post-operative complications and no readmissions to hospital. The mean length of stay was 16.9 hours (SD=7.3), with most patients seen once on average by physiotherapy. Active range of motion at 6 weeks was 0.7o to 130.5 o, with all patients mobilising independently. The average 6-month post-operative Oxford Knee Score was 43.5 out of 48. There were no readmission or complications in any of our patients. This initial feasibility study identified that patients could be safely discharged within 24 hours after UKR using the NAVIO robotic system. With growing uptake of robotic procedures, with longer operative durations than traditional procedures, it is essential to ensure a rapid discharge to reduce healthcare cost whilst ensuring that patients are discharged home in a safe manner.
The coronavirus (Covid-19) pandemic, first identified in China in December 2019, halted daily living with mandatory lockdowns imposed in Israel in March 2020. This halt induced a sedentary lifestyle for most citizens as well as a decreased physical activity time. These are both common risk factors for the development of low back pain (LBP) which is considered a major global medical and economical challenge effecting almost 1 in 3 people and a leading cause of Emergency Department (ED) visits. It is hypothesized that prevalence of minor LBP episodes during the first total lockdown should have increased compared to previous times. However, due to “Covid-19 fear” we expect a decrease in ED visits. We also speculate that rate of visits due to serious spinal illness (causing either immediate hospitalization or spinal surgery within 30-days of presentation) did not change. Retrospective study based on patients visiting the ED in Tel Aviv Sourasky Medical Center During the first pandemic stage in 2020 compared to parallel periods in 2018 and 2019 due to LBP.Introduction and Objective
Materials and Methods
In the United Kingdom (UK), the fastest growing population demographic is the over 85 years of age, but despite this, outcomes achieved in the octogenarian population with a Unicompartmental Knee Replacement (UKR) are underrepresented in the literature. The Elective Orthopaedic Centre, Epsom, has an established patient reported outcome measures (PROMs) programme into which all patients are routinely enrolled. We aim to investigate the outcome of medial UKR using the oxford phase 3 implant in octogenarians. We retrospectively reviewed our database for patients aged 60–89 years, who underwent a medial unicompartmental Knee Replacement (UKR) using the oxford phase 3 implant, between June 2007-December 2012 (N=395). The patients were stratified into 3 groups based on age, 60–69 (N=188), 70–79(N=149), and 80–89(N=58). Oxford Knee Scores (OKS), Euro-quol (EQ-5D) scores, revision rates, and mortality were compared.Background
Methods
Open talus fracture are notoriously difficult to manage and they are commonly associated with a high level of complications including non-union, avascular necrosis and infection. Currently, the management of such injuries is based upon BOAST 4 guidelines although there is no suggested definitive management, thus definitive management is based upon surgeon preference. The key principles of open talus fracture management which do not vary between surgeons, however, there is much debate over whether the talus should be preserved or removed after open talus fracture/dislocation and proceeded to tibiocalcaneal fusion. A review of electronic hospital records for open talus fractures from 2014-2021 returned foureen patients with fifteen open talus fractures. Seven cases were initially managed with ORIF, five cases were definitively managed with FUSION, while the others were managed with alternative methods. We collected patient's age, gender, surgical complications, surgical risk factors and post-treatment functional ability and pain and compliance with BOAST guidelines. The average follow-up of the cohort was four years and one month. EQ-5D-5L and FAAM-ADL/Sports score was used as a patient reported outcome measure. Data was analysed using the software PRISM. Comparison between FUSION and ORIF groups showed no statistically significant difference in EQ-5D-5L score ( FUSION is typically used as second line to ORIF or failed ORIF. However, there are a lack of studies that directly compared outcome in open talus fracture patients definitively managed with FUSION or ORIF. Our results demonstrate for the first time, that FUSION may not be inferior to ORIF in terms of patient functional outcome, infection rate, and quality-of-life, in the management of patients with open talus fracture patients. Of note, as open talus fractures have increased risks of complications such as osteonecrosis and non-union, FUSION should be considered as a viable option to mitigate these potential complications in these patients.
Rib fractures (RF) represent the most common bone fracture after blunt trauma, occurring in 10–20% of all trauma patients and leading to concomitant injuries of the inner organs in severe cases. However, a standardized classification system for serial rib fractures (SRF) does still not exist. Basic knowledge about the facture pattern of SRF would help to predict organ damage, support forensic medical examinations, and provide data for in vitro and in silico studies regarding the thoracic stability. The purpose of our study was therefore to identify specific SRF patterns after blunt chest trauma. All SRF cases (≥3 subsequent RF) between mid-2008 and end of 2015 were extracted from the CT database of our University Hospital (n=383). Fractures were assigned to anterior, antero-lateral, lateral, postero-lateral, and posterior location within the transverse plane (36° each) using an angular measuring technique (reliability ±2°). Rib level, fracture type (transverse, oblique, multifragment, infracted), as well as degree of dislocation (none, </≥ rib width) were recorded and each related to the cause of accident. In total, 3747 RF were identified (9.7 per patient, ranging from 3 (n=25) to 33 (n=1)). On average, most RF occurred in crush/burying injuries (15.9, n=13) and pedestrian accidents (12.2, n=14), least in car/truck accidents (8.8, n=76). Altogether, RF gradually increased from rib 1 (n=140) towards rib 5 (n=517) and then decreased towards rib 12 (n=49), showing a bell-shaped distribution. More RF were detected on the left thorax (n=2027) than on the right (n=1720). Overall, most RF were found in the lateral (33%) and postero-lateral (29%) segment. Posterior RF mostly occurred in the lower thorax (63%), whereas anterior (100%), antero-lateral (87%), and lateral (63%) RF mostly appeared in the upper thorax. RF were distributed symmetrically to the sagittal plane, showing a hotspot (up to 98 RF) at rib levels 4 to 7 in the lateral segment and rib level 5 in the antero-lateral segment. In the car/truck accident group, 47% of all RF were in the lateral segment, in case of frontal collision (n=24) even 60%. Fall injuries (n=141) entailed mostly postero-lateral RF (35%). In case of falls >3 m (n=45), 48% more RF were detected on the left thorax compared to the right. CPR related SRF (n=33) showed a distinct fracture pattern, since 70% of all RF were located antero-laterally. Infractions were the most observed fracture type (44%), followed by oblique (25%) and transverse (18%) fractures, while 46% of all RF were dislocated (15% ≥ rib width). SRF show distinct fracture patterns depending on the cause of accident. Additional data should be collected to confirm our results and to establish a SRF classification system.
Ankle fractures are among the most common types of fractures. If surgery is not performed within 12 to 24 hours, ankle swelling is likely to develop and delay the operative fixation. This leads to patients staying longer in the ward waiting and increased hospital occupancy. This prolonged stay has significant financial implication as well as it is frustrating for both patients and health care professionals. The aim was to formulate a pathway for the ankle fracture patients coming to the emergency department, outpatients and planned for operative intervention. To identify whether pre-operative hospital admissions of stable ankle fracture patients are reduced with the implementation of the pathway. We formulated an ankle fracture fixation pathway, which was approved for use in December 2020. A
In a consecutive
Abstract. Introduction. In general the life expectancy of population is improving. This is causing to increase case load of peri-prosthesis fractures after joint replacements. We present our results of peri-prosthesis fracture around hip managed by revision arthroplasty. Methods. A
Neck of femur fracture (NOF#) is the commonest reason for admission to an orthopaedic ward with 70-75,000 cases each year in the UK. 1. The femoral head is often sent to pathology if there is clinical suspicion of a malignant cause. There is limited evidence in the literature to support the efficacy of this. 2. The purpose of this project was to study the incidence of femoral head pathology analysis in NOF # patients with a background of malignancy and evaluate the impact this investigation has on guiding future management.
Orthopedic device-related infection (ODRI) preclinical models are widely used in translational research. Most models require induction of general anesthesia, which frequently results in hypothermia in rodents. This study aimed to evaluate the impact of peri anesthetic hypothermia in rodents on outcomes in preclinical orthopedic device-related infection studies. A
Introduction. The non-union of long bones poses a substantial challenge to clinicians and patients alike. The Ilizarov fixation system and Limb Reconstruction System (LRS), renowned for their versatility in managing complex non-unions. The purpose of this retrospective study was to assess the outcomes of acute docking with the bone peg-in-bone technique for the management of non-unions of long bones. The study seeks to evaluate its effectiveness in achieving complete bony union, preserving limb length and alignment, correcting existing deformities, and preventing the onset of new ones. Method. A
Introduction. Unplanned reoperations (UROs) following corrective surgery for adult spinal deformity (ASD) present significant challenges for both patients and surgeons. Understanding the specific UROs types is crucial for improving patient outcomes and refining surgical strategies in ASD correction. Method. This
Introduction. The concept of same-day discharge has garnered increasing significance within orthopedic surgery, particularly in hip and knee procedures. Despite initial concerns surrounding the absence of prolonged hospital care, a burgeoning body of evidence highlights numerous advantages associated with same-day discharge, ranging from mitigating in-hospital infections to offering substantial financial and psychosocial benefits for both patients and healthcare providers. In this study, we aim to scrutinize the trends in same-day discharge specifically within the realm of total hip arthroplasties. Method. This
The current study aims to find the role of Enhance Recovery Pathway (ERP) as a multidisciplinary approach aimed to expedite rapid recovery, reduce LOS, and minimize morbidity associated with Non Fusion Anterior Scoliosis Correction (NFASC) surgery. A
Abstract. Objectives. Obesity is prevalent with nearly one third of the world's population being classified as obese. Total knee arthroplasty (TKA) is an effective treatment option for high BMI patients achieving similar outcomes to non-obese patients. However, increased rates of aseptic loosening in patients with a high BMI have been reported. In patients with high BMI/body mass there is an increase in strain placed on the implant fixation interfaces. As such component fixation is a potential concern when performing TKA in the obese patient. To address this concern the use of extended tibial stems in cemented implants or cementless fixation have been advocated. Extend tibial stems are thought to improve implant stability reducing the micromotion between interfaces and consequently the risk of aseptic loosening. Cementless implants, once biologic fixation is achieved, effectively integrate into bone eliminating an interface. This retrospective study compared the use of extended tibial stems and cementless implants to conventional cemented implants in high BMI patients. Methods. From a prospectively maintained database of 3239 primary Attune TKA (Depuy, Warsaw, Indiana), obese patients (body mass index (BMI) >30 kg/m²) were retrospectively reviewed. Two groups of patients 1) using a tibial stem extension [n=162] and 2) cementless fixation [n=163] were compared to 3) a control group (n=1426) with a standard tibial stem cemented implant. All operations were performed by or under the direct supervision of specialist arthroplasty surgeons. Analysis compared the groups with respect to class I, II, and III (BMI >30kg/m², >35 kg/m², >40 kg/m²) obesity. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Where radiographic images at greater than 3 months post-operatively were available, radiographs were examined to compare the presence of peri-implant radiolucent lines. Results. The mean follow-up of 4.8, 3.4, and 2.5 years for cemented, stemmed, and cementless groups respectively. In total there were 34 all-cause revisions across all the groups with revision rates of 4.55, 5.50, and 0.00 per 1000-implant-years for cemented, stemmed, and cementless groups respectively. Survival Analysis did not show any significant differences between the three groups for all-all cause revision. There were 6 revisions for aseptic loosening (5 tibial and 1 femoral); all of which were in the standard cemented implant group. In contrast there were no revisions in the stemmed or cementless implant groups, however, this was not significant on survival analysis. Analysis looking at class I, II, and III obesity also did not show any significant differences in survival for all cause revision or aseptic loosening. Conclusion. This