Introduction. Septic arthritis of the hip in the newborn baby can result in severe long term sequelae in the form of dislocation of the hip, loss of movement and growth disturbance with leg length discrepancy. Reconstructive procedures for this difficult problem have not been satisfactory. Patient and methods. This series comprises eight patients with
Purpose. We analyzed a consecutive series of 36 total hip arthroplasties using cementless conical stem with a shortening osteotomy combined with greater trochanter transfer in cases with a high dislocated hip. Material and Methods. The causes of total hip arthroplasty were the sequelae of a
Patients with a history of septic arthritis or tuberculosis (TB) of the hip frequently develop secondary osteoarthritis (OA). These patients present a challenge for having joint replacement because of abnormal bone development, the possibility of re-infection, soft tissue problems and their life-style (more active than patients with old age arthritis). We retrospectively review a decent group of 55 cases where one stage cemented total hip arthroplasty was performed with history of old hip infection by a team of surgeons at Wrightington Hospital, Lancashire, UK from 1970 to 2008. The purpose of this study is to find the survival analysis with revision (for infection) as the end stage. There are 33 females and 22 males aged from 25 to 75 yrs (mean 52 years). 21 patients had proven or probable tuberculous infection, 29 had the past history of old
Background: Childhood
This study was undertaken to assess the feasibility of a new subtrochanteric osteotomy technique for total hip arthroplasty (THA) in cases with a high dislocated hip secondary to the sequelae of a
Introduction and objective: Infection is one of the greatest threats in hip surgery. It is agreed that the implant should be removed. The debate remains open if one or two stage surgery is perferable. This study evaluates the two stage
Reasons for bone loss in
Due to medical and organizational factors, it occurs in everyday practice that spacers are left in place longer than originally planned during a two-stage prosthesis exchange in the case of prosthetic joint infections. Patients are severely restricted in their mobility and, after initial antibiotic administration, the spacer itself only acts as a foreign body. The aim of this study is to analyze whether the duration of the spacer in situ has an influence on the long-term success of treatment and mortality. We retrospectively studied all 204 two-stage prosthesis replacements of the hip and knee from 2012 to 2016 with a minimum follow-up of two years at an arthroplasty center with 3 main surgeons. The duration of the spacer interval was divided into two groups. Patients replanted within ten weeks (as is standard in multiple algorithms) after systemic antibiotic treatment were assigned to the ‘Regular Spacer Interval (< 70 days)’ group. If the spacer interval was longer, they were assigned to the ‘Long Spacer Interval (≥ 70 days)’ group.Aim
Method
Introduction. Antibiotic loaded polymethyle methacrylate spacers are commonly used in the management of septic hip replacements. Aim. The aim of this study was to determine wear patterns on the articulating surfaces of these spacers, as well as to determine the extent of PMMA particulate debris generation. Method. We took tissue specimens around the acetabulae in 12 cases at the time of the second stage procedure for
Since July 1996, we have treated 97 patients who developed sepsis following total knee arthroplasty and 53 who developed sepsis following total hip arthroplasty. We evaluated the rate of retention of prosthesis. In 69 A-host patients, 80 B-host and 1 C-host, we identified 70 cases of Staphylococcus aureus, 76 of Staphylococcus epidermidis, 33 of Pseudomonas, 23 of Escherichia coli and 18 of Enterococcus. Five patients were diabetic. Muscle flaps were used in 51 cases. Of the 131 patients available for follow-up, 94 healed with retention of prosthesis. Five patients had to undergo amputation. We are still treating 36 patients, some of whom have received a temporary prosthesis. Most patients could be salvaged with a two-staged revision. Host status influenced outcome.
Traditionally, serum white blood count (WBC), C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) have been utilized as markers to evaluate septic arthritis (SA). Recently, neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) have been identified as prognostic factors for treatment failure, mortality and morbidity in various clinical settings. To date, these markers have not been utilized for evaluating outcomes after hip and knee SA. Thus, the purpose of this study was to determine the ability of admission NLR and PLR to predict treatment failure and postoperative 90-day mortality in hip and knee SA. A retrospective study was performed using our institutional research patient database to identify 235 patients with native hip and knee septic arthritis from 2000–2018. Patient demographics, comorbidities and social factors (alcohol intake, smoking and intravenous drug use) were obtained, and NLR and PLR were calculated based on complete blood count values (absolute neutrophil, lymphocyte and platelet count) on admission. Treatment failure was defined as any reoperation or readmission within 90 days after surgery. Receiver operating curves were analyzed, and optimal thresholds for NLR and PLR were determined using Youden's test. Univariate and multivariate analyses were performed to determine if these ratios were independent predictors of treatment failure and 90-day mortality after surgery. These ratios were compared to serum WBC, CRP, and ESR.Aim
Method
Infection of total hip replacement still is considered a devastating complication. One-stage revision, meaning complete removal of the implant and thorough debridement of the site together with the insertion of a new prosthesis during the same operation, is desirable because of improved rehabilitation of the patient and reduced costs. Although this method is known since more than 30 years it is not used widely yet because of several related risks: known methods rely on the use of antibiotic-loaded cement, which often has shown insufficient release of the added antibiotic. The carrier may even act as a bed for colonisation with selected bacteria. Osseous conditions presented during revisions prevent interconnection of the cement with the sclerotic bone. The toxic monomers of PMMA and heating during polymerisation causes necroses which may be origin of repeated loosening and new growth of bacteria. Filling the defects with cement provides unfavourable conditions in case of another revision, which has to be expected at a high percentage. To overcome these disadvantages uncemented techniques seem to be favourable. After removal of the implants debridement is performed as in conventional septic surgery. After thorough cleaning and rinsing, bone voids are filled with bone graft using an impaction technique. We use allograft or xenograft bone that is free from antigenic material but intact structures of bone concerning collagen and mineral content. The bone is impregnated with high loads of antibiotic, using a specific incubation technique. There are two options of antibiotic impregnation: vancomycin (“V”) or tobramycin (“T”), the choice being dependent on the causative pathogen isolated. Combinations are possible in cases of mixed infections. The impregnation procedure guarantees high levels of antibiotics at the grafting site for several weeks during which the antibiotic is released into the surroundings. Systemic drug levels are usually undetectable. At the acetabular site we take care that the ground be sufficiently filled with antibiotic graft. Preferably an uncemented cup of hemispherical design is inserted. At the femoral site we prefer implants with a rectangular diameter. This design enables stable press fit contact with the shaft medially and laterally and leaves enough space for graft impaction at the posterior and anterior aspect of the endoprosthesis. Wounds are drained and closed immediately; rehabilitation is performed as after non-septic surgery. Between 1998 and 2004 thirty-seven patients have been revised because of culture-proven infection of hip endoprosthesis. Causative pathogens were Coag.neg. staph (18x), S.aureus (11x), MRSA (4x), enterococci (9x) and other gram-positive pathogens (3x). In 6 hips gram-negative germs were found additionally. All hips could be followed up with a minimum of 2 years and a maximum of 8 years (mean: 4.1 years). Wound healing was uneventful in all cases. Mean hospital stay was 16 days (10–32 days). Rehabilitation was in the range of uncomplicated primary THR in cases with short history of infection (up to 3 months) and prolonged in relation to duration of infection and amount of preceding surgery. In three hips there was recurrence of the infection, diagnosed between 6 and 12 weeks after surgery. In one of them the well-fixed stem had not been exchanged, in another one a technical error had occurred during impregnation of the bone graft. This one could be successfully re-operated using the same technique with appropriately impregnated bone graft, the other two were converted to a girdlestone situation. All other 32 hips showed no sign of infection until the last follow-up. Bone processed in an adequate way represents an excellent carrier for vancomycin and tobramycin. With antibiotic graft compound eradication of pathogens, grafting of bony defects and re-insertion of an uncemented prosthesis may be accomplished in a single operation, making it an ideal tool in one stage non-cemented revision for infected total hip replacement. However, principles of septic surgery need to be observed. We now recommend removing even well-fixed prostheses and taking care, that we implant at least 50cc of well impregnated bone graft. Since the graft gradually is replaced by healthy own bone, improved conditions may be expected even in the case of another revision.
Between 1996 and 2003 35 patients have been revised because of culture proven infection of a hip endoprostheses. All hips could be followed with a minimum of 3months and a maximum of 6years.
Two-stage revision arthroplasty is the gold standard for treatment of infection after total hip Arthroplasty and end stage septic arthritis of the hip. In the first stage we used a modified technique to insert an inexpensive modular femoral component coated with antibiotic-impregnated polymethylmethacrylate articulating with a polyethylene liner. The construct was used in 8 patients with infected arthroplasty, and 6 patients with septic arthritis of the hip. Two patients were excluded (no second stage). Of the remaining 12 patients, only one patient had persistent infection after the first stage; 11 patients received a successful re-implantation at the second-stage. The technique provide a construct that can be used safely and successfully in the awaiting period between the two stages of revision arthroplasty.
Introduction: Septic total hip arthroplasty is a devastating complication. Most treatment protocols for infection of more than 2 – 3 weeks duration recommend removal of the prosthesis and cement followed by 4 – 6 weeks of IV antibiotics. Results using an antibiotic spacer to allow mobility of the patient and local antibiotic deliverance by elution from the spacer are reported. Methods: Since January of 1994, antibiotic spacers have been used as adjunctive treatment along with IV antibiotics and prosthetic resection in 18
We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty.
Aims. Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for
Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision necessitate removal of all bone cement from the femur. In our two institutions, we have been using a cement-in-cement technique, leaving the distal femoral cement in selected cases for
Background. The patients with high hip dislocation due to the sequelae of