Advertisement for orthosearch.org.uk
Results 1 - 20 of 297
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 12 - 12
1 Apr 2012
Menna C Deep K
Full Access

Total knee arthroplasty (TKA) is a common orthopaedic procedure. Traditionally the surgeon, based on experience, releases the medial structures in knees with varus deformity and lateral structures in knees with valgus deformity until subjectively they feel that they have achieved the intended alignment. The hypothesis for this study was that deformed knees do not routinely require releases to achieve an aligned lower limb in TKA. A single surgeon consecutive cohort of 74 patients undergoing computer navigated TKA was examined. The mechanical axes were taken as the references for distal femoral and proximal tibial cuts. The trans-epicondylar axis was taken as the reference for frontal femoral and posterior condylar cuts. A soft tissue release was undertaken after the bony cuts had been made if the mechanical femoro-tibial (MFT) angle in extension did not come to within 2° of neutral as shown by computer readings. The post-operative alignment was recorded on the navigation system and also analysed with hip-knee-ankle (HKA) radiographs. The range of pre-operative deformities on HKA radiographs was 15° varus to 27° valgus with a mean of 5° varus (SD 7.4°). Only two patients required a medial release. None of the patients required a lateral release. The post implant navigation value was within 2° of neutral in all cases. Post-operative HKA radiographs was available for 71 patients. The mean MFT angle from radiographs was 0.1° valgus (SD 2.1°). The range was from 6° varus to 7° valgus but only six patients (8.5%) were outside the ±3° range. The kinematic analysis also showed it to be within 2 degrees of neutral throughout the flexion making sure it is well balanced in 88% cases. This series has shown that over 90% of patients had limbs aligned appropriately without the need for routine soft tissue releases. The use of computer assisted bone cuts leads to a low level of collateral release in TKA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 43 - 43
1 Aug 2013
Changulani M Sankar B Deakin A Picard F
Full Access

Distal femur resection for correction of flexion contractures in total knee arthroplasty (TKA) can lead to joint line elevation, abnormal knee kinematics and patellofemoral problems. The aim of this retrospective study was to establish the contribution of soft tissue releases and bony cuts in the change in maximum knee extension in TKA. Data were available for 211 TKAs performed by a single surgeon using a medial approach. Intra-operatively pre- and post-implant extension angles and the size of bone resection were collected using a commercial navigation system. The thickness of polyethylene insert and the extent of soft tissue release performed (no release, moderate and extensive release) were collected from the patient record. A linear model was used to predict change in maximum extension from pre- to post-implant. The analysis showed that bone cuts (p<0.001), soft tissue release (p=0.001) and insert thickness (p=0.010) were all significant terms in the model (r. 2. adj. =0.170). This model predicted that carrying out a TKA with 19 mm bone cuts, 10 mm insert and no soft tissue release would give 4.2° increase in extension. It predicted that a moderate release would give a further 2.8° increase in extension with an extensive release giving 3.9°. For each mm increase in bone cuts the model predicted an 0.8° increase in extension and for each mm increase in insert size a decrease extension by 1.1°. The modelling results show that in general to increase maximum extension by the same as an extensive soft tissue release that bone cuts would have to be increased by 4–5 mm. However this model only accounted for 17% of the variation in change in extension pre- to post-implant so may not be accurate at predicting outcomes for specific patients


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 263 - 263
1 Jul 2014
Imai K Ikoma K Gay R Hirano T Ozasa Y Chen Q An K Zhao C
Full Access

Summary Statement. ASTM therapy is commonly used to treat Achilles tendinopaty. However, there was no report to evaluate the biomechanical effects, especially the dynamic viscoelasticity. We have shown that ASTM treatment was biomechanically useful for chronic Achilles tendinopathy in an animal model. Introduction. Achilles tendinopathy is a common chronic overuse injury. Because Achilles tendon overuse injury takes place in sports and there has been a general increase in the popularity of sports activities, the number and incidence of Achilles tendon overuse injury has increased. Augmented Soft Tissue Mobilization (ASTM) therapy is a modification of traditional soft tissue mobilization and has been used to treat a variety of musculoskeletal disorders. ASTM therapy is thought to promote collagen fiber realignment and hasten tendon repair. It might also change the biomechanical behavior of the injured tendon, especially the dynamic viscoelasticity. The purpose of this study is to evaluate the effect of ASTM therapy in a rabbit model of Achilles tendinopathy by quantifying dynamic biomechanical properties and histologic features. Patients & Methods. The hind limbs of 12 rabbits were used, and 24 Achilles tendons were injected with collagenase to produce tendon injury. One hind limb of each animal was then randomly allocated to receive ASTM therapy, while the other received no treatment and served as a control. ASTM was performed on the Achilles tendon for 3 minutes on postoperative days 21, 24, 28, 31, 35, and 38. The Achilles tendons were harvested 10 days after the last treatment. Specimens were examined with dynamic viscoelasticity and light microscopy. Results. The mean±SD cross-sectional area for the treated and untreated tendons was 12.30±5.47 mm. 2. and 9.57±8.36 mm. 2. , respectively. The difference between the treated and untreated tendons was statistically significant (P<.01). At all dynamic loading frequencies, the storage modulus in the untreated tendons tended to be higher than that in the treated tendons. At 0.1 Hz and 10 Hz, in the untreated tendons was significantly higher than that in the treated tendons (P=.05). The loss modulus was significantly lower in the treated tendons than in the untreated tendons (P<.05). There was no significant difference in tan δ between the treated and untreated tendons. HE stain showed that the untreated tendon fiber was wavy and kinking and displayed a disordered collagen arrangement. In contrast, the tendon fiber was well aligned in the treated tendons. In the immunohistochemically stained specimens, the type III collagen showed higher color intensity in the untreated tendons than in the treated tendons. Discussion/Conclusion. We have shown that ASTM was a biomechanically useful treatment for chronic Achilles tendinopathy. Biomechanical and histologic data showed the treated Achilles tendons had better biomechanical function and histologic outcomes than the untreated tendons


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 110 - 110
14 Nov 2024
Vettese J Julie M Evrard R Fieve L Lengelé B Cornu O
Full Access

Introduction

In tissue engineering, the establishment of sufficient vascularization is essential for tissue viability and functionality. Inadequate vascularization disrupts nutrients and oxygen supply. Nonetheless, regenerating intricate vascular networks represents a significant challenge. Consequently, research efforts devoted to preserving and regenerating functional vascular networks in engineered tissues are of paramount importance. The present work aims to validate a decellularisation process with preservation of the vascular network and extracellular matrix (ECM) components in fasciocutaneous flaps.

Method

Five vascularized fasciocutaneous flaps from cadaveric donors were carefully harvested from the anterolateral thigh (ALT), preserving the main perforator of the fascia lata. The entire ALT flap underwent decellularization by perfusion using a clinically validated chemical protocol. Fluoroscopy and computed tomography (CT) were used to analyze the persistence of the vascular network within the flap, pre- and post-decellularization. Histological analysis, including hematoxylin and eosin staining, and quantitative DNA assessment evaluated decellularization efficacy. Further qualitative (immunohistochemistry, IHC) and quantitative analyses were conducted to assess the preservation of ECM components, such as collagen, glycosaminoglycans, and elastin.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 71 - 71
1 Nov 2018
O'Cearbhaill E
Full Access

Efficient, repeatable and reliable insertion of microneedles into skin is paramount to ensure efficacious drug and vaccine delivery, as well as effective microneedle-based biosensing. Through maintaining robust mechanical adhesion, this microneedle platform offers significant potential in therapeutic delivery and longitudinal wearable applications. Here, we have shown that an angled microneedle design, which is conducive to self-administration, has the potential to address key limitations in existing microneedle technology.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 7 - 7
1 Apr 2012
Mullen M Pillai A Fogg Q Kumar CS
Full Access

The extended lateral approach offers a safe surgical approach in the fixation of calcaneal fractures. Lateral plating of the calcaneum could put structures on the medial side at risk. The aim was to identify structures at risk on the medial side of the calcaneum from wires, drills or screws passed from lateral to medial.

Ten embalmed cadaveric feet were dissected. A standard extended lateral approach was performed. The DePuy perimeter plate was first applied and 2mm K-wires were drilled through each of the holes. The medial side was now examined to determine the structures at risk through each hole. The process was repeated with the Stryker plate. The calcaneum was divided into 6 zones, by two vertical lines, from the margins of the posterior facet and a transverse line along the axis of the bone through the highest point of the peroneal tubercle.

The DePuy and the Stryker plates have 12 screw positions, 5 of which are common. With both systems, screw positions in zone 1 risk injury to the medial plantar nerve and zone 3 the lateral plantar nerve. A screw through zone 2 compromises the medial plantar in both. Screws through zone 4 risk the lateral plantar nerve with the DePuy plate. Screws through zone 5 of the DePuy plate risk the medial calcaneal nerve. Zone 5 of the Stryker plate and Zone 6 of both are safe.

There is significant risk to medial structures from laterally placed wires, drills or screws. Subtalar screws have the highest risk and have to be carefully measured and placed. The Stryker plating system is relatively safer than the DePuy perimeter plate with three safe zones out of six.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 1 - 1
17 Apr 2023
Sgardelis P Giddins G
Full Access

Distal radius fractures are common, particularly in post-menopausal women. Several factors have been identified such as osteopenia and an increased risk of falling. We hypothesised that increased soft tissue padding from muscle and fat in the volar hand may confer an element of protection against fractures more in men than women and more in younger than older patients. The aim of the study was to assess for thenar and hypothenar thickness and assess whether it varies between sexes and changes with age. We retrospectively evaluated hand MRI scans performed for non-acute conditions in adults without previous injury or surgery. Using the Patient Archiving and Communication System (PACS) we measured the distance (mm) from the volar surface of the trapezium to the skin, the hook of the hamate to skin and the pisiform to skin as measures of thenar and hypothenar thickness. We also recorded the sex and age of the subjects. Soft tissue thickness was corrected for hand size by dividing by capitate length which we measured; we have already established this as a surrogate measure of hand size. The scans of 51 men (mean age 35, range 19–66) years and 27 women (mean age 49, range 19–79) years were reviewed. Men had significantly thicker soft tissues compared to women over both the thenar and hypothenar eminences (p=0.0001). Soft tissue thickness did not change significantly with age (p> 0.05). The study confirms a significant difference in volar hand soft tissue thickness between men and women accounting for differences in hand size. Our previous research has shown how we fall onto our outstretched hands in the upper limb falling reflex and we have shown that padding the thenar and hypothenar eminences reduces force transmission to the forearm bones. In theory thicker thenar and hypothenar musculature would help protect against distal radius fractures following a fall on an outstretched hand. The thinner musculature on women may further predispose them to an increased risk of distal radius fractures. Further research is needed to assess for any loss of volar hand soft tissue thickness beyond age 75 years


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 29 - 29
1 Dec 2022
Pedrini F Salmaso L Mori F Sassu P Innocenti M
Full Access

Open limb fractures are typically due to a high energy trauma. Several recent studied have showed treatment's superiority when a multidisciplinary approach is applied. World Health Organization reports that isolate limb traumas have an incidence rate of 11.5/100.000, causing high costs in terms of hospitalization and patient disability. A lack of experience in soft tissue management in orthopaedics and traumatology seems to be the determining factor in the clinical worsening of complex cases. The therapeutic possibilities offered by microsurgery currently permit simultaneous reconstruction of multiple tissues including vessels and nerves, reducing the rate of amputations, recovery time and preventing postoperative complications. Several scoring systems to assess complex limb traumas exist, among them: NISSSA, MESS, AO and Gustilo Anderson. In 2010, a further scoring system was introduced to focus open fractures of all locations: OTA-OFC. Rather than using a single composite score, the OTA-OFC comprises five components grades (skin, arterial, muscle, bone loss and contamination), each rated from mild to severe. The International Consensus Meeting of 2018 on musculoskeletal infections in orthopaedic surgery identified the OTA-OFC score as an efficient catalogue system with interobserver agreement that is comparable or superior to the Gustilo-Anderson classification. OTA-OFC predicts outcomes such as the need for adjuvant treatments or the likelihood of early amputation. An orthoplastic approach reconstruction must pay adequate attention to bone and soft tissue infections management. Concerning bone management: there is little to no difference in terms of infection rates for Gustilo-Anderson types I–II treated by reamed intramedullary nail, circular external fixator, or unreamed intramedullary nail. In Gustilo-Anderson IIIA-B fractures, circular external fixation appears to provide the lowest infection rates when compared to all other fixation methods. Different technique can be used for the reconstruction of bone and soft tissue defects based on each clinical scenario. Open fracture management with fasciocutaneous or muscle flaps shows comparable outcomes in terms of bone healing, soft tissue coverage, acute infection and chronic osteomyelitis prevention. The type of flap should be tailored based on the type of the defect, bone or soft tissue, location, extension and depth of the defect, size of the osseous gap, fracture type, and orthopaedic implantation. Local flaps should be considered in low energy trauma, when skin and soft tissue is not traumatized. In high energy fractures with bone exposure, muscle flaps may offer a more reliable reconstruction with fewer flap failures and lower reoperation rates. On exposed fractures several studies report precise timing for a proper reconstruction. Hence, timing of soft tissue coverage is a critical for length of in-hospital stay and most of the early postoperative complications and outcomes. Early coverage has been associated with higher union rates and lower complications and infection rates compared to those reconstructed after 5-7 days. Furthermore, early reconstruction improves flap survival and reduces surgical complexity, as microsurgical free flap procedures become more challenging with a delay due to an increased pro-thrombotic environment, tissue edema and the increasingly friable vessels. Only those patients presenting to facilities with an actual dedicated orthoplastic trauma service are likely to receive definitive treatment of a severe open fracture with tissue loss within the established parameters of good practice. We conclude that the surgeon's experience appears to be the decisive element in the orthoplastic approach, although reconstructive algorithms may assist in decisional and planification of surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 15 - 15
17 Apr 2023
Inglis B Inacio J Dailey H
Full Access

Virtual mechanical testing is a method for measuring bone healing using finite element models built from computed tomography (CT) scans. Previously, we validated a dual-zone material model for ovine fracture callus that differentiates between mineralized woven bone and soft tissue based on radiodensity. 1. The objective of this study was to translate the dual-zone material model from sheep to two important clinical scenarios: human tibial fractures in early-stage healing and late-stage nonunions. CT scans for N = 19 tibial shaft fractures were obtained prospectively at 12 weeks post-op. A second group of N = 33 tibial nonunions with CT scans were retrospectively identified. The modeling techniques were based on our published method. 2. The dual-zone material model was implemented for humans by performing a cutoff sweep for both the 12-week and nonunion groups. Virtual torsional rigidity (VTR) was calculated as VTR = ML/φ [N-m. 2. /°], where M is the moment reaction, L is the diaphyseal segment length, and φ is the angle of twist. As the soft tissue cutoff was increased, the rigidity of the clinical fractures decreased and soft tissue located within the fracture gaps produced higher strains that are not predicted without the dual zone approach. The structural integrity of the nonunions varied, ranging from very low rigidities in atrophic cases to very high rigidities in highly calcified hypertrophic cases, even with dual-zone material modeling. Human fracture calluses are heterogeneous, comprising of woven bone and interstitial soft tissue. Use of a dual-zone callus material model may be instrumental in identifying delayed unions during early healing when callus formation is minimal and/or predominantly fibrous with little mineralization. ACKNOWLEDGEMENTS:. This work was supported by the National Science Foundation (NSF) grant CMMI-1943287


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 115 - 115
2 Jan 2024
Akbar M Crowe L Woolcock K Cole J McInnes I Millar N
Full Access

Dupuytren's disease (DD) is a fibroproliferative soft tissue disease affecting the palmar fascia of the hand causing permanent and irreversible flexion contracture. Aberrant fibrosis is likely to manifest through a combination of extrinsic, intrinsic, and environmental factors, including genetics and epigenetics. However, the role of epigenetics in soft tissue fibrosis in diseases such as DD is not well established. Therefore, we conducted a comprehensive multi-omic study investigating the epigenetic profiles that influence gene expression in DD pathology. Using control (patients undergoing carpal tunnel release) and diseased fibroblasts (patients undergoing Dupuytren's fasciectomy), we conducted ATAC-seq to assess differential chromatin accessibility between control and diseased fibroblasts. Additionally, ChIP-seq mapped common histone modifications (histone H4; H3K4me3, H3K9me3, H3K27me3, H4K16Ac, H4K20Me3) associated with fibrosis. Furthermore, we extracted RNA from control and DD tissue and performed bulk RNA-seq. ATAC-seq analysis identified 2470 accessible genomic loci significantly more accessible in diseased fibroblasts compared to control. Comparison between diseased and control cells identified numerous significantly different peaks in histone modifications (H4K20me3, H3K27me3, H3K9me3) associated with gene repression in control cells but not in diseased cells. Pathway analysis demonstrated a substantial overlap in genes being de-repressed across these histone modifications (Figure 1). Both, ATAC-seq and ChIP-seq analysis indicated pathways such as cell adhesion, differentiation, and extracellular matrix organisation were dysregulated as a result of epigenetic changes. Moreover, de novo motif enrichment analysis identified transcription factors that possibly contributed to the differential gene expression between control and diseased tissue, including HIC1, NFATC1 and TEAD2. RNA-seq analysis found that these transcription factors were upregulated in DD tissue compared to control tissue. The current epigenetic study provides insights into the aberrant fibrotic processes associated with soft tissue diseases such as DD and indicates that epigenetic-targeted therapies may be an interesting viable treatment option in future. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 108 - 108
14 Nov 2024
Marchiori G Zaffagnini S Cavazza L Fabbro GD Grassi A Lopomo NF Giavaresi G Maglio M
Full Access

Introduction. Histology is still considered the gold standard method for the evaluation of soft tissues in the musculoskeletal field, thanks to the possibility of studying structures using different staining and high magnification microscopy. To overcome the intrinsic limits of this method, contrast enhanced microtomographic (CE- microCT) protocols are constantly evolving to allow 3D study of soft tissues. However, no standardized approaches are available, and many concerns exist about the alterations induced to the samples. Method. microCT/histology protocols were explored on human tendons and menisci. To enhance contrast tissues for microCT scanning 1) examethyldisilazane drying 2) 2% phosphotungstic acid (PTA) in alcoholic solution exposition and 3) 2% PTA in aqueous solution exposition were performed; to observe PTA contrast progression, three exposition and scanning times were selected. microCT images were compared to histological slices obtained from the same samples, after rehydration protocols, or from adjacent tissues portion, stained with Picrosirius red to highlight the peculiar collagenic structures. Result. Exposition times influence PTA diffusion and tissue contrast; its specificity for collagenic structure allow a clearer contrast of the tissues. Histological processing on the same samples is possible: PTA removal requires careful washing in basic solution to reduce the hardening of the sample, while drying can be reverted applying inverse protocol. Comparison with microCT images is really accurate if histology is performed on the same sample, although all protocols induce tissue shrinkage with relative packing of collagen fibers. Conclusion. The contrast approaches tested proved effective in highlighting the structures of both tendons and menisci, but the structural effects induced by tissue shrinkage do not allow a completely real microCT visualization of native tissue. Histology can be the reference method to monitor the efficacy of the contrast methods and the alterations induced to define the possibility of improvement of the technique. Acknowledgement. PR23-PAS-P4 “ADJOINT 2”- INAIL


To describe clinical situations for use of modified VAC in POC based on: diagnosis, comorbidities, BMI, wound size in cm, days following trauma when VAC was first applied, total duration of uninterrupted use, frequency of change, settings, bacterial growth, outcomes. To report the outcomes of mVAC use in POC within 6 months to help improve and standardize its application in the institution. This study involves data gathering from inpatients handled by orthopedic surgeons in training and subspecialty rotations in POC. The data collected are highly dependent on the doctors-in-charge's complete charting, thorough reporting and accurate documentation. Modified Vacuum Assisted Closure (mVAC) is used frequently in this study and is defined as a form of revised, adapted and reformed use of VAC based on available materials in the involved institution. The materials that are included are, but not limited to the following: sterile Uratex™ blue foam, nasogastric or suction tubing, phlegm suction machine, Bactigras™ and Opsite™ or Ioban™. A total of 58 patients were included in the study. The average age of the population was 35 and are predominantly male. The most common mechanism of injury was motorcycle accident and 37 of the patients were diagnosed with an open fracture of the lower extremity with open tibia fractures (22) being the most common. Average wound area measured was 24.12 cm. 3. All patients yield a bacteria growth with e. coli being the most frequent. Average during of uninterrupted use was 39 days. Of the 58 included in the study, 8 patients underwent STSG, 2 had a flap coverage surgery, 4 patients eventually underwent amputation and 33 with complete resolution of soft tissue defect after conversion to biologic dressing post-mVAC. The rest of the population were still ongoing mVAC at the end of the study. mVAC is an alternative temporary medium for soft tissue coverage for cases with or without concomitant fractures. mVAC promotes removal of exudate from the wound, supports wound apposition and granulation bed proliferation. Usage mVAC helps prepare for skin coverage procedure and on some cases leads to full resolution of defect


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 65 - 65
17 Apr 2023
Tacchella C Lombardero SM Clutton E Chen Y Crichton M
Full Access

In this work, we propose a new quantitative way of evaluating acute compartment syndrome (ACS) by dynamic mechanical assessment of soft tissue changes. First, we have developed an animal model of ACS to replicate the physiological changes during the condition. Secondly, we have developed a mechanical assessment tool for quantitative pre-clinical assessment of ACS. Our hand-held indentation device provides an accurate method for investigations into the local dynamic mechanical properties of soft tissue and for in-situ non-invasive assessment and monitoring of ACS. Our compartment syndrome model was developed on the cranial tibial and the peroneus tertius muscles of a pig's leg (postmortem). The compartment syndrome pressure values were obtained by injecting blood from the bone through the muscle. To enable ACS assessment by a hand-held indentation device we combined three main components: a load cell, a linear actuator and a 3-axis accelerometer. Dynamic tests were performed at a frequency of 0.5 Hz and by applying an amplitude of 0.5 mm. Another method used to observe the differences in the mechanical properties inside the leg was a 3D Digital Image Correlation (3D-DIC). Videos were taken from two different positions of the pig's leg at different pressure values: 0 mmHg, 15 mmHg and 40 mmHg. Two strains along the x axis (Exx) and y axis (Eyy) were measured. Between the two pressure cases (15 mmHg and 40 mmHg) a clear deformation of the model is visible. In fact, the bigger the pressure, the more visible the increase in strain is. In our animal model, local muscle pressures reached values higher than 40 mmHg, which correlate with observed human physiology in ACS. In our presentation we will share our dynamic indentation results on this model to demonstrate the sensitivity of our measurement techniques. Compartment syndrome is recognised as needing improved clinical management tools. Our approach provides both a model that reflects physiological behaviour of ACS, and a method for in-situ non-invasive assessment and monitoring


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 6 - 6
1 Nov 2021
Lu V Zhang J Thahir A Lim JA Krkovic M
Full Access

Introduction and Objective. Despite the low incidence of pilon fractures among lower limb injuries, their high-impact nature presents difficulties in surgical management and recovery. Current literature includes a wide range of different management strategies, however there is no universal treatment algorithm. We aim to determine clinical outcomes in patients with open and closed pilon fractures, managed using a treatment algorithm that was applied consistently over the span of this study. Materials and Methods. This retrospective study was conducted at a single institution, including 141 pilon fractures in 135 patients, from August 2014 to January 2021. AO/OTA classification was used to classify fractures. Among closed fractures, 12 had type 43A, 18 had type 43B, 61 had type 43C. Among open fractures, 11 had type 43A, 12 had type 43B, 27 had type 43C. Open fractures were further classified with Gustilo-Anderson (GA); type 1: n=8, type 2: n=10, type 3A: n=12, type 3B: n=20. Our treatment algorithm consisted of fine wire fixator (FWF) for severely comminuted closed fractures (AO/OTA type 43C3), or open fractures with severe soft tissue injury (GA type 3). Otherwise, open reduction internal fixation (ORIF) was performed. When required, minimally invasive osteosynthesis (MIO) was performed in combination with FWF to improve joint congruency. All open fractures, and closed fractures with severe soft tissue injury (skin contusion, fracture blister, severe oedema) were initially treated with temporary ankle-spanning external fixation. For all open fracture patients, surgical debridement, soft tissue cover with a free or pedicled flap were performed. For GA types 1 and 2, this was done with ORIF in the same operating session. Those with severe soft tissue injury (GA type 3) were treated with FWF four to six weeks after soft tissue management was completed. Primary outcome was AOFAS Ankle-Hindfoot score at 3, 6 and 12-months post-treatment. Secondary outcomes include time to partial weight-bear (PWB) and full weight-bear (FWB), bone union time. All complications were recorded. Results. Mean AOFAS score 3, 6, and 12 months post-treatment for open and closed fracture patients were 44.12 and 53.99 (p=0.007), 62.38 and 67.68 (p=0.203), 78.44 and 84.06 (p=0.256), respectively. 119 of the 141 fractures healed without further intervention (84.4%). Average time to bone union was 51.46 and 36.48 weeks for open and closed fractures, respectively (p=0.019). Union took longer in closed fracture patients treated with FWF than ORIF (p=0.025). On average, open and closed fracture patients took 12.29 and 10.76 weeks to PWB (p=0.361); 24.04 and 20.31 weeks to FWB (p=0.235), respectively. Common complications for open fractures were non-union (24%), post-traumatic arthritis (16%); for closed fractures they were post-traumatic arthritis (25%), superficial infection (22%). Open fracture was a risk factor for non-union (p=0.042; OR=2.558, 95% CI 1.016–6.441), bone defect (p=0.001; OR=5.973, 95% CI 1.986–17.967), and superficial infection (p<0.001; OR=4.167, 95% CI 1.978–8.781). Conclusions. The use of a two-staged approach involving temporary external fixation followed by definitive fixation, provides a stable milieu for soft tissue recovery. FWF combined with MIO, where required for severely comminuted closed fractures, and FWF for open fractures with severe soft tissue injury, are safe methods achieving low complication rates and good functional recovery


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 29 - 29
1 Jan 2019
Yao J Mengoni M Williams S Jones A
Full Access

Acetabular tissue damage is implicated in osteoarthritis (OA) and investigation of in situ acetabular soft tissues behaviour will improve understanding of tissue properties and interconnections. The study aim was to visualise acetabular soft tissues under load and to quantify displacements using computed tomography (CT) scans (XtremeCT, Scano Medical). A CT scan (resolution 82 μm) was performed on the disarticulated, unloaded porcine acetabulum. The femoral head was soaked in Sodium Iodide (NaI) solution and cling film wrapped to prevent transfer to the acetabular side. The joint was realigned, compressed using cable ties and re-scanned. The two images were down-sampled to 0.3 mm. Acetabular bone and soft tissues were segmented. Bony features were used to register the two background images, using Simpleware ScanIP 7.0 (Synopsys), to the same position and orientation (volume difference < 5%). Acetabular soft tissues displacements were measured by tracking the same points at the tissue edges on the two acetabular masks, along with difference in bone position as an additional error assessment. The use of radiopaque solution provided a clear contrast allowing separation of the femoral and acetabular soft tissues in the loaded image. The image registration process resulted in a difference in bone position in the areas of interest equivalent to image resolution (0.3 mm, a mean of 3 repeats by same user). A labral tip displacement of 1.7 mm and a cartilage thickness change from 1.5 mm unloaded to 0.9 mm loaded, were recorded. The combination of contrast enhancement, registration and focused local measurement was precise enough to reduce bone alignment error to that of image resolution and reveal local soft tissue displacements. These measurement methods can be used to develop models of soft tissues properties and behaviour, and therapy for hip tissue damage at early stage may be reviewed and optimised


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 22 - 22
1 Mar 2021
Makelov B Silva J Apivatthakakul T Gueorguiev B Varga P
Full Access

Osteosynthesis of high-energy metaphyseal proximal tibia fractures is still challenging, especially in patients with severe soft tissue injuries and/or short stature. Although the use of external fixators is the traditional treatment of choice for open comminuted fractures, patients' acceptance is low due to the high profile and therefore the physical burden of the devices. Recently, clinical case reports have shown that supercutaneous locked plating used as definite external fixation could be an efficient alternative. Therefore, the aim of this study was to evaluate the effect of implant configuration on stability and interfragmentary motions of unstable proximal tibia fractures fixed by means of externalized locked plating. Based on a right tibia CT scan of a 48 years-old male donor, a finite element model of an unstable proximal tibia fracture was developed to compare the stability of one internal and two different externalized plate fixations. A 2-cm osteotomy gap, located 5 cm distally to the articular surface and replicating an AO/OTA 41-C2.2 fracture, was virtually fixed with a medial stainless steel LISS-DF plate. Three implant configurations (IC) with different plate elevations were modelled and virtually tested biomechanically: IC-1 with 2-mm elevation (internal locked plate fixation), IC-2 with 22-mm elevation (externalized locked plate fixation with thin soft tissue simulation) and IC-3 with 32-mm elevation (externalized locked plate fixation with thick soft tissue simulation). Axial loads of 25 kg (partial weightbearing) and 80 kg (full weightbearing) were applied to the proximal tibia end and distributed at a ratio of 80%/20% on the medial/lateral condyles. A hinge joint was simulated at the distal end of the tibia. Parameters of interest were construct stiffness, as well as interfragmentary motion and longitudinal strain at the most lateral aspect of the fracture. Construct stiffness was 655 N/mm (IC-1), 197 N/mm (IC-2) and 128 N/mm (IC-3). Interfragmentary motions under partial weightbearing were 0.31 mm (IC-1), 1.09 mm (IC-2) and 1.74 mm (IC-3), whereas under full weightbearing they were 0.97 mm (IC-1), 3.50 mm (IC-2) and 5.56 mm (IC-3). The corresponding longitudinal strains at the fracture site under partial weightbearing were 1.55% (IC-1), 5.45% (IC-2) and 8.70% (IC-3). From virtual biomechanics point of view, externalized locked plating of unstable proximal tibia fractures with simulated thin and thick soft tissue environment seems to ensure favorable conditions for callus formation with longitudinal strains at the fracture site not exceeding 10%, thus providing appropriate relative stability for secondary bone healing under partial weightbearing during the early postoperative phase


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 130 - 130
2 Jan 2024
Dvorak N
Full Access

In-vitro models of disease are valuable tools for studying disease and analysing response to therapeutics. Recently, advances in patient-derived organoid (PDO) models have been shown to faithfully recapitulate structure, function, and therapeutic response for a wide range of tissues. Frozen shoulder is a rare example of a chronic inflammatory fibrotic disease which is self-limiting, unlike many other soft tissue fibrotic disorders. As no in-vitro 3D models or in-vivo animal models exist for frozen shoulder, establishing an organoid model which recapitulates core diseases features may give insight into fibrosis resolution. Consequently, using biocompatible hydrogels, primary capsular fibroblasts, monocyte-derived macrophages and HUVEC cells, we generated stable PDO cultures which exhibited key disease phenotypes, including vascularization, increased stiffness, and an expanded lining layer over 21 days of culture. Through further investigation of cell-matrix and cell-cell interactions in the organoid model, we intend to unpack the differences between resolving and non-resolving fibrotic disease and uncover clinically relevant therapeutic targets for fibrosis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 77 - 77
2 Jan 2024
Gueorguiev B Varga P
Full Access

Intramedullary nails (IMNs) are the current gold standard for treatment of long bone diaphyseal and selected metaphyseal fractures. Their design has undergone many revisions to improve fixation techniques, conform to the bone shape with appropriate anatomic fit, reduce operative time and radiation exposure, and extend the indication of the same implant for treatment of different fracture types with minimal soft tissue irritation. The IMNs are made or either titanium alloy or stainless steel and work as load-sharing internal splints along the long bone, usually accommodating locking elements – screws and blades, often featuring angular stability and offering different configurations for multiplanar fixation – to secure secondary fracture healing with callus formation in a relative-stability environment. Bone cement augmentation of the locking elements can modulate the construct stiffness, increase the surface area at the bone-implant interface, and prevent cut-through of the locking elements. The functional requirements of IMNs are related to maintaining fracture reduction in terms of length, alignment and rotation to enhance fracture healing. The load distribution during patient's activities is along the entire bone-nail interface, with nail length and anatomic fit being important factors to avoid stress risers


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 79 - 79
2 Jan 2024
Rasouligandomani M Chemorion F Bisotti M Noailly J Ballester MG
Full Access

Adult Spine Deformity (ASD) is a degenerative condition of the adult spine leading to altered spine curvatures and mechanical balance. Computational approaches, like Finite Element (FE) Models have been proposed to explore the etiology or the treatment of ASD, through biomechanical simulations. However, while the personalization of the models is a cornerstone, personalized FE models are cumbersome to generate. To cover this need, we share a virtual cohort of 16807 thoracolumbar spine FE models with different spine morphologies, presented in an online user-interface platform (SpineView). To generate these models, EOS images are used, and 3D surface spine models are reconstructed. Then, a Statistical Shape Model (SSM), is built, to further adapt a FE structured mesh template for both the bone and the soft tissues of the spine, through mesh morphing. Eventually, the SSM deformation fields allow the personalization of the mean structured FE model, leading to generate FE meshes of thoracolumbar spines with different morphologies. Models can be selectively viewed and downloaded through SpineView, according to personalized user requests of specific morphologies characterized by the geometrical parameters: Pelvic Incidence; Pelvic Tilt; Sacral Slope; Lumbar Lordosis; Global Tilt; Cobb Angle; and GAP score. Data quality is assessed using visual aids, correlation analyses, heatmaps, network graphs, Anova and t-tests, and kernel density plots to compare spinopelvic parameter distributions and identify similarities and differences. Mesh quality and ranges of motion have been assessed to evaluate the quality of the FE models. This functional repository is unique to generate virtual patient cohorts in ASD. Acknowledgements: European Commission (MSCA-TN-ETN-2020-Disc4All-955735, ERC-2021-CoG-O-Health-101044828)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 69 - 69
4 Apr 2023
Smeeton M Wilcox R Isaac G Anderson J Board T Van Citters D Williams S
Full Access

Dual mobility (DM) total hip replacements (THRs) were introduced to reduce dislocation risk, which is the most common cause of early revision. Although DM THRs have shown good overall survivorship and low dislocation rates, the mechanisms which describe how these bearings function in-vivo are not fully understood. Therefore, the study aim was to comprehensively assess retrieved DM polyethylene liners for signs of damage using visual inspection and semi-quantitative geometric assessment methods. Retrieved DM liners (n=18) were visually inspected for the presence of surface damage, whereby the internal and external surfaces were independently assigned a score of one (present) or zero (not present) for seven damage modes. The severity of damage was not assessed. The material composition of embedded debris was characterised using energy-dispersive x-ray analysis (EDX). Additionally, each liner was geometrically assessed for signs of wear/deformation [1]. Scratching and pitting were the most common damage modes on either surface. Additionally, burnishing was observed on 50% of the internal surfaces and embedded debris was identified on 67% of the external surfaces. EDX analysis of the debris identified several materials including titanium, cobalt-chrome, iron, and tantalum. Geometric analysis demonstrated highly variable damage patterns across the liners. The incidence of burnishing was three times greater for the internal surfaces, suggesting that this acts as the primary articulation site. The external surfaces sustained more observable damage as evidenced by a higher incidence of embedded debris, abrasion, delamination, and deformation. In conjunction with the highly variable damage patterns observed, these results suggest that DM kinematics are complex and may be influenced by several factors (e.g., soft tissue fibrosis, patient activities) and thus further investigation is warranted