Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and
We reviewed 43 patients who had sustained
Being challenging, multifragmentary proximal tibial fractures in patients with severe soft tissue injuries and/or short stature can be treated using externalized locked plating. A recent finite element study, investigating the fixation stability of plated unstable tibial fractures with 2-mm, 22-mm and 32-mm plate elevation under partial and full weight-bearing, reported that from a virtual biomechanical point of view, externalized plating seems to provide appropriate relative stability for secondary bone healing under partial weight-bearing during the early postoperative phase. The aim of the current study was to evaluate the clinical outcomes of using a LISS plate as a definitive external fixator for the treatment of multifragmentary proximal tibial fractures. Following appropriate indirect reduction, externalized locked plating was performed and followed up in 12 patients with multifragmentary proximal tibial fractures with simple intraarticular involvement and injured soft tissue envelope.Introduction
Methods
The objectives of this study were to compare the systemic inflammatory reaction, localised thermal response and macroscopic soft tissue injury outcomes in conventional jig-based total knee arthroplasty (conventional TKA) versus robotic total knee arthroplasty (robotic TKA). This prospective randomised controlled trial included 30 patients with symptomatic knee osteoarthritis undergoing conventional TKA versus robotic TKA. Predefined serum markers of inflammation and localised knee temperature were collected preoperatively and postoperatively at 6 hours, day 1, day 2, day 7, and day 28 following TKA. Blinded observers used the Macroscopic Soft Tissue Injury (MASTI) classification system to grade intraoperative periarticular soft tissue injury and bone trauma. Plain radiographs were used to assess the accuracy of achieving the planned limb alignment and implant positioning in both treatment groups.Introduction
Methods
The role of arthroscopy in the treatment of soft-tissue
injuries associated with proximal tibial fractures remains debatable.
Our hypothesis was that MRI over-diagnoses clinically relevant associated
soft-tissue injuries. This prospective study involved 50 consecutive
patients who underwent surgical treatment for a split-depression fracture
of the lateral tibial condyle (AO/OTA type B3.1). The mean age of
patients was 50 years (23 to 86) and 27 (54%) were female. All patients
had MRI and arthroscopy. Arthroscopy identified 12 tears of the
lateral meniscus, including eight bucket-handle tears that were
sutured and four that were resected, as well as six tears of the
medial meniscus, of which five were resected. Lateral meniscal injuries
were diagnosed on MRI in four of 12 patients, yielding an overall
sensitivity of 33% (95% confidence interval (CI) 11 to 65). Specificity
was 76% (95% CI 59 to 88), with nine tears diagnosed among 38 menisci
that did not contain a tear. MRI identified medial meniscal injuries
in four of six patients, yielding an overall sensitivity of 67%
(95% CI 24 to 94). Specificity was 66% (95% CI 50 to 79), with 15
tears diagnosed in 44 menisci that did not contain tears. MRI appears to offer only a marginal benefit as the specificity
and sensitivity for diagnosing meniscal injuries are poor in patients
with a fracture. There were fewer arthroscopically-confirmed associated
lesions than reported previously in MRI studies. Cite this article:
This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements. Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups.Aims
Methods
Osteomyelitis is an inflammatory condition accompanied by the destruction of bone and caused by an infecting microorganism. Open contaminated fractures can lead to the development of osteomyelitis of the fractured bone in 3-25% of cases, depending on fracture type, degree of
A major pathway of closed
Objectives. The use of the haptically bounded saw blades in robotic-assisted total knee arthroplasty (RTKA) can potentially help to limit surrounding
We have analysed 249 consecutive fractures of the humeral shaft treated over a three-year period. The fractures were defined by their AO morphology, position, the age and gender of the patient and the mechanism of injury. Open fractures were classified using the Gustilo system and
We assessed factors which may affect union in 32 patients with nonunion of a fracture of the diaphysis of the femur and 67 comparable patients whose fracture had united. These included gender, age, smoking habit, the use of non-steroidal anti-inflammatory drugs (NSAIDs) the type of fracture (AO classification),
The October 2014 Oncology Roundup. 360 . looks at: how best to reconstruct humeral tumours; not everything is better via the arthroscope; obesity and sarcoma; frozen autograft; en-bloc resection and metastatic disease; positive margins in
Tibial shaft fractures co-existing with osteoarthritis can increase the challenges for the orthopedic surgeon. The novel Londhe-Shah technique manages both the problems using one-stage total knee arthroplasty with a long stemmed tibial component which has a good diaphyseal fit. Three osteoarthritis patients with fractures of tibial shaft were treated with this technique and were followed up at 6-weeks, 12-weeks and 1-year (figure 1–3). A complete union of the fractured segment was achieved at follow-up without any adverse events such as infection, damage to the implant, and
1. Eighty consecutive open fractures of the tibial shaft were treated by primary internal fixation and wound closure. Wound healing was complicated by deep infection in eight patients (10 per cent) and by skin loss of varying degree in ten (l2·5 per cent). 2. Careful selection of patients on the basis of associated
We describe the results of treatment of open tibial fractures in 92 children; 22 fractures were Gustilo type I, 51 type II and 19 type III. All children received tetanus prophylaxis, systemic antibiotics for 48 hours and thorough debridement and irrigation of the wound. Fifty-one wounds with minimal
This is a prospective analysis on 30 physically
active individuals with a mean age of 48.9 years (35 to 64) with chronic
insertional tendinopathy of the tendo Achillis. Using a transverse
incision, the tendon was debrided and an osteotomy of the posterosuperior
corner of the calcaneus was performed in all patients. At a minimum
post-operative follow-up of three years, the Victorian Institute
of Sports Assessment scale – Achilles tendon scores were significantly
improved compared to the baseline status. In two patients a superficial
infection of the wound developed which resolved on antibiotics.
There were no other wound complications, no nerve related complications,
and no secondary avulsions of the tendo Achillis. In all, 26 patients
had returned to their pre-injury level of activity and the remaining
four modified their sporting activity. At the last appointment,
the mean pain threshold and the mean post-operative tenderness were
also significantly improved from the baseline (p <
0.001). In patients
with insertional tendo Achillis a transverse incision allows a wide
exposure and adequate debridement of the tendo Achillis insertion,
less
Between 2005 and 2010 ten consecutive children
with high-energy open diaphyseal tibial fractures were treated by early
reduction and application of a programmable circular external fixator.
They were all male with a mean age of 11.5 years (5.2 to 15.4),
and they were followed for a mean of 34.5 months (6 to 77). Full
weight-bearing was allowed immediately post-operatively. The mean
time from application to removal of the frame was 16 weeks (12 to
21). The mean deformity following removal of the frame was 0.15°
(0° to 1.5°) of coronal angulation, 0.2° (0° to 2°) sagittal angulation,
1.1 mm (0 to 10) coronal translation, and 0.5 mm (0 to 2) sagittal
translation. All patients achieved consolidated bony union and satisfactory
wound healing. There were no cases of delayed or nonunion, compartment
syndrome or neurovascular injury. Four patients had a mild superficial
pin site infection; all settled with a single course of oral antibiotics.
No patient had a deep infection or re-fracture following removal
of the frame. The time to union was comparable with, or better than,
other published methods of stabilisation for these injuries. The
stable fixator configuration not only facilitates management of
the accompanying
Non-accidental injury (NAI) in children includes orthopaedic trauma throughout the skeleton. Fractures with
Injury to the perforating branch of the peroneal artery has not been reported previously as a cause of acute compartment syndrome following