Introduction Debonding at the cement-prosthesis interface leading to stem movement and abrasion, has been proposed as initiating events in aseptic loosening of cemented total hip arthroplasties. A polished tapered or an absolutely stable stem possibly minimises this risk. This study evaluated a cemented, precoated femoral stem for
Clinical Problen: the avulsion fracture of the MT V bone and the Jones fractures are typical fractures under tenssion and therefore often require osteosynthesis. Materials and Methods: to avoid soft tissue problems due to the open reduction and implant on the bone surface on the lateral foot a percutaneus technique with a 3,5mm XXS locked compression nail was developed. The fracture is reduced with the gide wire witch is also used for the canulated 3,5mm drill wich prepares the canal for the nail. The locking is performed on both sides of the fracture with one 2mm threated wire and the dynamic compression of the Fracture of the fracture is performed with a set screw in the nail. All patients are allowed to walk free with normal foot wear. From Jul 1999 to Jan.2006 77 patients were treated according to the above technique. Results: Tha OAFAS of the patients preoperativ was 22 and postoperative 96. No pseudarthrosis or implant failures occured but in 53 patients (69%) implant removal was necessary because patients had discomfort due to the implant. Conclusion: the XXS nail is a new method for minimal invasive and
The avulsion fracture of the V-th metatarsal and Jones fractures often show delayed and non-union. The tension belt osteosynthesis shows often soft tissue problems due to the thin soft tisshe covering. A new minimal invasive method with the 3,5mm XXS nail and the clinical results are presented. Percutaneously the fracture is reduced with a K-wire as a joy stick. This or if the direction needed is different a second K-wire as guide is introduced and with a canulated 3,5 mm drill the place for the nail is prepared. Proximal and distal to the fracture one threaded wire locking and fracture compression through the nail (proximal longitudinal holes) are performed. 77 patients with a XXS nail fixation of MT V fractures were treated from July 1999 to Jan.2006. Clinical and radiological re-examination at 1 to 6 years were performed. The AOFAS was 22 pre- and 96 postoperatively. No pseudarthrosis but in 53 patients implant removal was done in part due to local discomfort. This was strictly correlated to the length of the threaded wires to the bone surface. 95% reached pretrauma activity levels. Satisfaction was 9 from 10 points. The XXS nails allow a percutaneous
The avulsion fracture of the V-th metatarsal and Jones fractures often show delayed and non-union. The tension belt osteosynthesis shows often soft tissue problems due to the thin soft tisshe covering. A new minimal invasive method with the 3,5mm XXS nail and the clinical results are presented. Percutaneously the fracture is reduced with a K-wire as a joy stick. This or if the direction needed is different a second K-wire as guide is introduced and with a canulated 3,5 mm drill the place for the nail is prepared. Proximal and distal to the fracture one threaded wire locking and fracture compression through the nail (proximal longitudinal holes) are performed. 77 patients with a XXS nail fixation of MT V fractures were treated from July 1999 to Jan.2006. Clinical and radiological re-examination at 1 to 6 years were performed. The AOFAS was 22 pre- and 96 postoperatively. No pseudarthrosis but in 53 patients implant removal was done in part due to local discomfort. This was strictly correlated to the length of the threaded wires to the bone surface. 95% reached pretrauma activity levels. Satisfaction was 9 from 10 points. The XXS nails allows a percutaneous
There is a growing trend towards using pre-clinical models of atrophic non-union. This study investigated different fixation devices, by comparing the mechanical stability at the fracture site of tibia bone fixed by either intramedullary nail, compression plate or external fixator. 40 tibias from adult male Wistar rats' cadavers were osteotomised at the mid-shaft and a gap of 1 mm was created and maintained at the fracture site to simulate criteria of atrophic non-union model. These were divided into five groups (n=8 in each): the first group was fixed with 20G intramedullary nail, the second group with 18G nail, the third group with 4-hole plate, the fourth group with 6-hole plate, and the fifth group with external fixator. Tibia was harvested by leg disarticulation from the knee and ankle joints, the soft tissues were carefully removed from the leg, and tibias were kept hydrated throughout the experiment. Each group was then subdivided into two subgroups for mechanical testing: one for axial loading (n=4) and one for 4-point bending (n=4). Statistical analysis was carried out by ANOVA with a fisher post-hoc comparison between groups. A p-value less than 0.05 was considered statistically significant. Axial load to failure data and stiffness data revealed that intramedullary nails are significantly stronger and stiffer than other devices, however there was no statistically significant difference axially between the nail thicknesses. In bending, load to failure revealed that 18G nails are significantly stronger than 20G. We concluded that 18G nail is superior to the other fixation devices, therefore it has been used for in-vivo experiments to create a novel model of atrophic non-union with
Early implant migration measured with radiostereometric analysis (RSA) has been proposed as a useful predictor of long-term fixation of tibial components in total knee arthroplasty. Evaluation of actual long-term fixation is of interest for cemented components, as well as for cementless fixation, which may offer long-term advantages once osseointegration has occurred. The objective of this study was to compare the long-term migration with one- and two-year migration to evaluate the predictive ability of short-term migration data and to compare migration and inducible displacement between cemented and cementless (porous metal monoblock) components at least ten years postoperatively. Patients who had participated in RSA migration studies with two-year follow-up were recruited to return for a long-term follow-up, at least ten years from surgery. Two cemented tibial designs from two manufacturers and one porous metal monoblock cementless tibial design were studied. At the long-term follow-up, patients had supine RSA examinations to determine migration and loaded examinations (single leg stance) to determine inducible displacement. In total, 79 patients (54 female) returned, with mean time since surgery of 12 years (10 to 14). There were 58 cemented and 21 cementless tibial components.Aims
Patients and Methods
Hallux valgus (HV) presents as a common forefoot deformity that causes problems with pain, mobility, footwear, and quality of life. The most common open correction used in the UK is the Scarf and Akin osteotomy, which has good clinical and radiological outcomes and high levels of patient satisfaction when used to treat a varying degrees of deformity. However, there are concerns regarding recurrence rates and long-term outcomes. Minimally invasive or percutaneous surgery (MIS) has gained popularity, offering the potential for similar clinical and radiological outcomes with reduced postoperative pain and smaller scars. Despite this, MIS techniques vary widely, hindering comparison and standardization. This review evaluates the evidence for both open Scarf and Akin osteotomy and newer-generation MIS techniques. Fourth-generation MIS emphasizes multiplanar rotational deformity correction through
We determined the short-term clinical outcome
and migration within the bone of the humeral cementless component
of the Instrumented Bone Preserving (IBP) total elbow replacement
in a series of 16 patients. There were four men and 12 women with
a mean age at operation of 63 years (40 to 81). Migration was calculated
using radiostereometric analysis. There were no intra-operative
complications and no revisions. At two-year follow-up, all patients
showed a significant reduction in pain and functional improvement
of the elbow (both p <
0.001). Although ten components (63%)
showed movement or micromovement during the first six weeks, 14
(88%) were stable at one year post-operatively. Translation was
primarily found in the proximal direction (median 0.3 mm (interquartile range
(IQR) -0.09 to 0.8); the major rotational movement was an anterior
tilt (median 0.7° (IQR 0.4° to 1.6°)). One malaligned component
continued to migrate during the second year, and one component could
not be followed beyond three months because migration had caused
the markers to break off the prosthesis. This study shows promising early results for the cementless humeral
component of the IBP total elbow replacement. All patients had a
good clinical outcome, and most components stabilised within six
months of the operation. Cite this article:
Aims. In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for
Aims. One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore,
The Fixion expandable nailing system provides an intramedullary fracture fixation solution without the need for locking screws. Proponents of this system have demonstrated shorter surgery times with rapid fracture healing, but several centres have reported suboptimal results with loss of fixation. This is the largest comparative series to be reported to date. We compared outcomes between 50 consecutive diaphyseal tibial fractures treated with a Fixion device at our institution to an age, sex and fracture configuration matched series of 57 fractures at a neighbouring hospital treated with a conventional interlocked intramedullary nail. Minimum follow up time was 2 years. Operating time was significantly reduced in the Fixion group (mean 61 minutes, range 20–99) compared to the interlocked group (88 minutes, 52–93), p< 0.00001. The union rate was no different between the Fixion group (93.9%) and the interlocked group (96.5%), p=0.527. Time to clinical and radiological union was significantly faster in the Fixion group (median 85 days, range 42–243) compared to the interlocked group (119, 70–362), p< 0.0001. The overall reoperation rate was lower in the Fixion series (24.5% vs 38.6%, p=0.121), although the majority of reoperations in the interlocked group were more minor, for screw removal. 3 Fixion nails were revised for fixation failure and 2 manipulations were required for rotational deformities after falls; all of these patients were non-compliant with post-operative instructions. There were no fixation failures in the interlocked group. 3 fractures were noted to propagate during inflation of Fixion nails. The Fixion nail is faster to implant and allows more physiological loading of the fracture, with a faster union time. However, these advantages are offset by a reduction in construct stability. Our results have demonstrated a learning curve with a reduction in complications as our indications were narrowed, avoiding osteoporotic, multifragmentary, unstable fractures and non-compliant patients
Displaced fractures of the radial neck in children can lead to limitation of elbow and forearm movements if left untreated. Several management techniques are available for the treatment of radial neck fractures in children. Open reduction can disturb the blood supply of the soft tissue surrounding the radial head epiphysis and is associated with more complications. We report our experience of treating 14 children between the age of 4 and 13 years, who had severely displaced radial neck fractures (Judet type 111 and 1V). 12 patients were treated with indirect reduction and fixation using the Elastic Stable Intramedullary Nail (ESIN) technique, (3 with assisted percutaneous K-wire reduction) and 2 had open reduction followed by ESIN fixation of the radial head fragment. This method reduces the need for open reduction and thus the complication rate. Three patients had associated fractures of the same forearm which was also treated surgically at the same time. We routinely immobilised the forearm for two weeks and removed the nail in all cases in an average of 12 weeks. We had no complication with implant removal. All 14 patients have been followed up for average of 28 months. One patient (7%) developed asymptomatic avascular necrosis (AVN) of the head of radius. Thirteen patients (93%) had excellent result on final review. One patient had neuropraxia of the posterior interosseous nerve which recovered within 6 weeks. In conclusion we advocate ESIN for the closed reduction and fixation of severely displaced radial neck fractures in children. It remains a useful fixation method even if open reduction is required and allows early mobilisation.
Several techniques are available for the treatment of displaced fractures of the neck of the radius in children. We report our experience in 14 children treated by indirect reduction and fixation using an elastic stable intramedullary nail. The patients were followed up for a mean of 28 months. One developed asymptomatic avascular necrosis. The rest had excellent results. One had a neuropraxia of the posterior interosseous nerve, which recovered within six weeks. We advocate elastic stable intramedullary nailing for the closed reduction and fixation of these fractures in children.
Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term
Aims. Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods. Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results. Median distal migration (y-axis) at two years for the Refobacin-Optivac system was -0.79 mm (-2.01 to -0.09), for the Refobacin-Optipac system was -0.75 mm (-2.16 to 0.20), and for the Palacos-Optivac system was -1.01 mm (-4.31 to -0.29). No statistically significant differences were found between the groups. Secondary outcomes did not differ statistically between the groups at the two-year follow-up. Conclusion. At two years, we found no significant differences in distal migration or clinical outcomes between the three groups. Our data indicate that Refobacin Bone Cement R and Palacos R + G are comparable in terms of
Aims. The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment. Methods. Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated. Results. Patients treated with ORIF showed significantly better postoperative range of motion for flexion and extension (121.1° (SD 16.4°) vs 108.1° (SD 25.8°); p = 0.018). Postoperative functional scores also showed significantly better results in the ORIF group (MEPS 90.1 (SD 13.6) vs 78 (SD 20.5); p = 0.004). There was no significant difference between the groups in terms of the complication rate (RHA 23.8% (n = 10) vs ORIF 26.2% (n = 11)). Implant-related complications occurred in six cases (14.3%) in the RHA group and in five cases (11.9%) in the ORIF group. Conclusion. Irrespective of the patient’s age, sex, type of injury, or number of fracture fragments, ORIF of the radial head should be attempted initially, if a stable reconstruction can be achieved, as it seems to provide a superior postoperative outcome for the patient compared to primary RHA. If reconstruction is not feasible, RHA is still a viable alternative. In the surgical treatment of complex radial head fractures, reconstruction shows superior postoperative outcomes compared to RHA. Good postoperative results can be achieved even after failed reconstruction and conversion to secondary RHA. Therefore, we encourage surgeons to favour reconstruction of complex radial head fractures, regardless of injury type or number of fragments, as long as a
Introduction. The management of fracture-related infection has undergone radical progress following the development of international guidelines. However, there is limited consideration to the realities of healthcare in low-resource environments due to a lack of available evidence in the literature from these settings. Initial antimicrobial suppression to support fracture union is frequently used in low- and middle-income countries despite the lack of published clinical evidence to support its practice. This study aimed to evaluate the outcomes following initial antimicrobial suppression to support fracture union in the management of fracture-related infection. Materials & Methods. A retrospective review of consecutive patients treated with initial antimicrobial suppression to support fracture healing followed by definitive eradication surgery to manage fracture-related infections following intramedullary fixation was performed. Indications for this approach were; a soft tissue envelope not requiring reconstructive surgery, radiographic evidence of