Imageless computer navigation systems have the potential to improve acetabular cup position in total hip arthroplasty (THA), thereby reducing the risk of revision surgery. This study aimed to evaluate the accuracy of three alternate registration planes in the
Introduction. The pelvis is not a static structure. It rotates in the sagittal plane depending upon the activity being performed. These dynamic changes in pelvic tilt have a substantial effect on the functional orientation of the acetabulum. The aim of this study was to quantify the changes in sagittal pelvic position between three functional postures. Methodology. Pre-operatively, 90 total hip replacement patients had their pelvic tilt measured in 3 functional positions – standing,
The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery. Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution.
Purpose. The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery. Methods. Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution.
Background. Cup anteversion and inclination are important to avoid implant impingement and dislocation in total hip arthroplasty (THA). However, it is well known that functional cup anteversion and cup inclination also change as the pelvic sagittal inclination (PSI) changes, and many reports have been made to investigate the PSI in
The aim of this study is to assess the discrepancy between weight bearing long leg radiographs and
Introduction:. External rotation (ER) of the shoulder is a commonly used clinical measurement to assess the glenohumeral joint; however, the position in which these measurements are obtained varies between clinicians. The purpose of this study was to compare the following: ER in the upright &
Total hip arthroplasty (THA) using minimally invasive surgeries (MIS) now become popular operative procedures. It is not easy to understand geometric information of pelvis and femur in the restricted operative fields during MIS-THA. Recently, THA in
Aims. Comparison of the outcome between the
Background.
The anterior pelvic plane (APP) angle is often used as a reference to decide pelvic alignment for hip surgeons. However, Rousseau criticised the validness of the APP angles because the APP angles in standing position measured on conventional standing X-ray films never showed correlation with the other pelvic alignment parameters, such as sacral slope (SS). We measured the APP angles, SS and pelvic tilt (PT) on the non-distorted anteroposterior (AP) and lateral digitally reconstructed radiography (DRR) images in
Introduction. Current techniques in total knee arthroplasty aim to restore the coronal mechanical axis to neutral. Preoperative planning has historically been based on long-leg standing films (LLSF) which allow surgeons to plan bony resection and soft tissue releases. However, LSSF can be prone to error if malrotated. Recently, patient-specific guides (PSG) utilizing
Iliopsoas tendonitis occurs in up to 30% of patients after hip resurfacing arthroplasty (HRA) and is a common reason for revision. The primary purpose of this study was to validate our novel computational model for quantifying iliopsoas impingement in HRA patients using a case-controlled investigation. Secondary purpose was to compare these results with previously measured THA patients. We conducted a retrospective search in an experienced surgeon's database for HRA patients with iliopsoas tendonitis, confirmed via the active hip flexion test in
The emergence of patient specific instrumentation has seen an expansion from simple radiographs to plan total knee arthroplasty (TKA) with modern systems using computed tomography (CT) or magnetic resonance imaging scans. Concerns have emerged regarding accuracy of these non-weight bearing modalities to assess true mechanical axis. The aim of our study was to compare coronal alignment on full length standing AP imaging generated by the EOS acquisition system with the CT coronal scout image. Eligible patients underwent unilateral or bilateral primary TKA for osteoarthritis under the care of investigating surgeon between 2017 and 2022, with both EOS X-Ray Imaging Acquisition System and CT scans performed preoperatively. Coronal mechanical alignment was measured on the
The clinical diagnosis of distal radioulnar joint (DRUJ) instability remains challenging. The current diagnostic gold standard is a dynamic computerized topography (CT) scan. This investigation compares the affected and normal wrists in multiple static positions of forearm rotation.. However, its accuracy has been questioned, as the wrist is unloaded and not placed under stress. This may fail to capture DRUJ instability that does not result in static malalignment between the ulnar head and sigmoid notch. The purpose of this biomechanical study was to evaluate the effectiveness of both dynamic and stress CT scans in detecting DRUJ instability. A customized DRUJ arthrometer was designed that allows for both static positioning, as well as dorsal and volar loading at the DRUJ in various degrees of forearm rotation. Ten fresh frozen cadavers were prepared and mounted in the apparatus. CT scans were performed both in the unloaded condition (dynamic CT) and with each arm subjected to a standardized 50N volar and dorsal force (stress CT) in neutral and maximum pronation/
The role of anconeus in elbow stability has been a long-standing debate. Anatomical and electromyographic studies have suggested a potential role as a stabilizer. However, to our knowledge, no clinical or biomechanical studies have investigated its role in improving the stability of a lateral collateral ligament (LCL) deficient elbow. Seven cadaveric upper extremities were mounted in an elbow motion simulator in the varus position. An LCL injured model was created by sectioning of the common extensor origin, and the LCL. The anconeus tendon and its aponeurosis were sutured in a Krackow fashion and tensioned to 10N and 20N through a transosseous tunnel at its origin. Varus-valgus angles and ulnohumeral rotations were recorded using an electromagnetic tracking system during simulated active elbow flexion with the forearm pronated and supinated. During active motion, the injured model resulted in a significant increase in varus angulation (5.3°±2.9°, P=.0001 pronation, 3.5°±3.4°, P=.001 supination) and external rotation (ER) (8.6°±5.8°, P=.001 pronation, 7.1°±6.1°, P=.003 supination) of the ulnohumeral articulation compared to the control state (varus angle −2.8°±3.4° pronation, −3.3°±3.2°
Compared to single-incision distal biceps repair (SI), double-incision repair (DI) theoretically allows for reattachment of the tendon to a more anatomically favorable position. We hypothesized that DI repair would result in greater terminal
Compared to single-incision distal biceps repair (SI), double-incision repair (DI) theoretically allows for reattachment of the tendon to a more anatomically favorable position. We hypothesized that DI repair would result in greater terminal
Introduction. The direct anterior approach (DAA) for total hip arthroplasty continues to gain popularity. Consequently, more procedures are being performed with the patient
Iliopsoas impingement occurs in between 5–30% of patients after hip arthroplasty and has been thought to only be caused by an oversized cup, cup malpositioning, or the depth of the psoas valley. However, no study has associated the relationship between preoperative measurements with the risk of impingement. This study sought to assess impingement between the iliopsoas and acetabular cup using a novel validated model to determine the risk factors for iliopsoas impingement. 413 patients received lower limb CT scans and lateral x-rays that were segmented, landmarked, and measured using a validated preoperative planning protocol. Implants were positioned according to the preference of ten experienced surgeons. The segmented bones were transformed to the standing reference frame and simulated with a novel computational model that detects impingement between the iliopsoas and acetabular cup. Definitions of patients at-risk and not at-risk of impingement were defined from a previous validation study of the simulation. At-risk patients were propensity score matched to not at-risk patients. 21% of patients were assessed as being at-risk of iliopsoas impingement. Significant differences between at-risk patients and not at-risk patients were observed in standing pelvic tilt (p << 0.01), standing femoral internal rotation (p << 0.01), medio-lateral centre-of-rotation (COR) change (p << 0.01),