Advertisement for orthosearch.org.uk
Results 1 - 20 of 388
Results per page:
Bone & Joint Open
Vol. 4, Issue 5 | Pages 393 - 398
25 May 2023
Roof MA Lygrisse K Shichman I Marwin SE Meftah M Schwarzkopf R

Aims

Revision total knee arthroplasty (rTKA) is a technically challenging and costly procedure. It is well-documented that primary TKA (pTKA) have better survivorship than rTKA; however, we were unable to identify any studies explicitly investigating previous rTKA as a risk factor for failure following rTKA. The purpose of this study is to compare the outcomes following rTKA between patients undergoing index rTKA and those who had been previously revised.

Methods

This retrospective, observational study reviewed patients who underwent unilateral, aseptic rTKA at an academic orthopaedic speciality hospital between June 2011 and April 2020 with > one-year of follow-up. Patients were dichotomized based on whether this was their first revision procedure or not. Patient demographics, surgical factors, postoperative outcomes, and re-revision rates were compared between the groups.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 911 - 919
21 Oct 2024
Clement N MacDonald DJ Hamilton DF Gaston P

Aims

The aims were to assess whether joint-specific outcome after total knee arthroplasty (TKA) was influenced by implant design over a 12-year follow-up period, and whether patient-related factors were associated with loss to follow-up and mortality risk.

Methods

Long-term follow-up of a randomized controlled trial was undertaken. A total of 212 patients were allocated a Triathlon or a Kinemax TKA. Patients were assessed preoperatively, and one, three, eight, and 12 years postoperatively using the Oxford Knee Score (OKS). Reasons for patient lost to follow-up, mortality, and revision were recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


Bone & Joint Open
Vol. 5, Issue 8 | Pages 681 - 687
19 Aug 2024
van de Graaf VA Shen TS Wood JA Chen DB MacDessi SJ

Aims

Sagittal plane imbalance (SPI), or asymmetry between extension and flexion gaps, is an important issue in total knee arthroplasty (TKA). The purpose of this study was to compare SPI between kinematic alignment (KA), mechanical alignment (MA), and functional alignment (FA) strategies.

Methods

In 137 robotic-assisted TKAs, extension and flexion stressed gap laxities and bone resections were measured. The primary outcome was the proportion and magnitude of medial and lateral SPI (gap differential > 2.0 mm) for KA, MA, and FA. Secondary outcomes were the proportion of knees with severe (> 4.0 mm) SPI, and resection thicknesses for each technique, with KA as reference.


Bone & Joint Open
Vol. 3, Issue 7 | Pages 573 - 581
1 Jul 2022
Clement ND Afzal I Peacock CJH MacDonald D Macpherson GJ Patton JT Asopa V Sochart DH Kader DF

Aims

The aims of this study were to assess mapping models to predict the three-level version of EuroQoL five-dimension utility index (EQ-5D-3L) from the Oxford Knee Score (OKS) and validate these before and after total knee arthroplasty (TKA).

Methods

A retrospective cohort of 5,857 patients was used to create the prediction models, and a second cohort of 721 patients from a different centre was used to validate the models, all of whom underwent TKA. Patient characteristics, BMI, OKS, and EQ-5D-3L were collected preoperatively and one year postoperatively. Generalized linear regression was used to formulate the prediction models.


Bone & Joint Research
Vol. 10, Issue 8 | Pages 467 - 473
2 Aug 2021
Rodríguez-Collell JR Mifsut D Ruiz-Sauri A Rodríguez-Pino L González-Soler EM Valverde-Navarro AA

Aims

The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray.

Methods

In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and measured cement layer thickness at both levels of the resected surface of the epiphysis and the endomedular metaphyseal level.


Abstract. Introduction. The role of patellar resurfacing in total knee arthroplasty remains controversial. We questioned the effect of patellar resurfacing on the early and late revision rates after total knee arthroplasty. Materials and Methods. We analysed the data of cumulative revisions of primary knee replacement from the NJR 19th Annual Report. NJR included secondary patellar resurfacing as a revision. We compared differences in the 3-year and 15-year revision rates between the patellar resurfacing and non-resurfacing for the different combinations of total knee replacements using a paired t-test. We performed subgroup analysis for the five combinations with the highest volumes. Results. Twenty-seven implant combinations had the 15-year revision rates reported. Patellar resurfacing group had lower mean 3-year revision rate of 1.68 (SD 0.7) compared to 2.02 (SD 0.9) in non-resurfacing group (p=0.05). However, 15-year revision rate was similar between the two groups (mean 5.7, SD 2.1 vs. mean 5.7, SD 2.2; p = 0.46). High volume implants showed that two combinations (NexGen CR and PS) had similar revision rates at 3 and 15 years between resurfacing and non-resurfacing groups. Three combinations (PFC Sigma CR and PS and Genesis 2 CR) had higher revision rate in non-resurfacing group at 3 years (p=0.01) and the difference persisted at 15 years (p=0.05). Conclusions. Although revision rate in total knee arthroplasty was higher without patellar resurfacing at 3 years, at 15 years the difference was not significant. However, the higher revision without patellar resurfacing can be prosthetic combination specific which surgeons need to be aware of


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 9 - 9
1 Jul 2022
Fleming T Torrie A Murphy T Dodds A Engelke D Curwen C Gosal H Pegrum J
Full Access

Abstract. INTRODUCTION. COVID-19 reduced availability of cross-sectional imaging, prompting the need to clinically justify pre-operative computed tomography (CT) in tibial plateau fractures (TPF). The study purpose was to establish to what extent does a CT alter the pre-operative plan in TPF compared to radiographs. There is a current paucity of evidence assessing its impact on surgical planning. METHODOLOGY. 50 consecutive TPF with preoperative CT were assessed by 4 consultant surgeons. Anonymised radiographs were assessed defining the column classification, planned setup, approach, and fixation technique. At a 1-month interval, randomised matched CT scans were assessed and the same data collected. A tibial plateau disruption score (TPDS) was derived for all 4 quadrants (no injury=0,split=1,split/depression=2 and depression=3). Radiograph and CT TPDS were assessed using an unpaired T-test. RESULTS. 26 female and 24 male patients, mean age 50.3, were included. Mean TPDS on radiographs and CT scans were 2.77 and 3.17 respectively. A significant higher net CT TPDS was observed of 0.4 (95%CI 0.10-0.71)[P=0.0093]. Both radiograph and CT TPDS ANOVA were significant (P<0.0001), showing high intraobserver variability for TPF classification. Fracture apex requiring fixation changed in 34% of cases between the radiographs and CT, whilst set-up and surgical approach changed in 27% and 28.5% of cases respectively. All surgeons agreed no CT was required in only 11 out of 50 cases. CONCLUSION. CT scanning in TPF significantly affects the classification, setup, approach and fixation technique when compared to radiographs alone and can justifiably be requested as part of pre-operative planning


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 64 - 64
1 Jul 2022
Dayananda K Dalal S Thomas E Chandratreya A Kotwal R
Full Access

Abstract. INTRODUCTION. A paucity of literature exists regarding efficacy of lateral unloader bracing in treatment for pathologies effecting the lateral compartment of the knee. We evaluate patient outcomes following customised lateral unloader bracing (cLUB) in treatment of lateral compartment osteoarthritis (LCOA), lateral tibial plateau fractures (LTPF) and spontaneous osteonecrosis of knee (SONK). METHODS. Institutional study approval was obtained. All patients undergoing cLUB between January 2013 and January 2021 were included, and prospectively followed-up. Visual Analogue Scales (VAS), Oxford Knee Scores (OKS) and Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed at brace fitting and final follow-up. Brace compliance, complications and surgical interventions were also collected. Statistical analysis utilised paired t-test. RESULTS. 71 patients (LCOA n=47, LTPF n=21, SONK n=3) were analysed. VAS, OKS and KOOS scores show significant improvements after bracing (p<0.05). Brace compliance was 90.5%. One patient developed a deep-vein thrombosis, 12.7% suffered skin irritation (n=5 LTPF/n=4 LCOA) managed with bio-skin calf sleeves, and brace intolerance occurred in 8.5% (n=6). Brace survivorship was 64.8% (n=46). Twenty-five patients underwent post-bracing surgery; LTPF n=2, LCOA n=22, SONK n=1. The mean time interval between brace fitting and arthroplasty for LKOA patients was 2.1 (range 0.5-4) years. CONCLUSION. Our cohort demonstrates good compliance and significant improvements with cLUB across acute and chronic pathologies. Surgery and associated risks were avoided in certain cases. Further research is required alongside a cost-analysis. However, with increasing disease burden and surgical waiting times cLUB could be a crucial component of management in selected knee pathology cases


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims. Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. Methods. This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss. Results. No statistically significant differences in stem length, operative side, or indications for revision were found between the two cohorts. Tibial pain at the end of the stem was present in 25.3% (16/63) of cemented stems and 25.5% (12/47) of uncemented stems (p = 1.000); 74.6% (47/63) of cemented patients and 78.7% (37/47) of uncemented patients were satisfied following revision TKA (p = 0.657). Conclusion. There were no differences in patient satisfaction, overall pain, and diaphyseal tibial pain in cemented and uncemented stemmed tibial components in revision TKA. Patient factors, rather than implant selection and surgical technique, likely play a large role in the presence of postoperative pain. Stemmed tibial components have been shown to be a possible source of pain in revision TKA. There is no difference in patient satisfaction or postoperative pain with cemented or uncemented stemmed tibial components in revision TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):165–170


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 48 - 48
1 Oct 2020
Alamanda VK Sapountzis N Joseph A Chiu Y Cross M Windsor RE Rodriguez JA
Full Access

Introduction. Instability following total knee arthroplasty is a leading cause of failure and is often treated with component revision. The goal of this study was to determine if isolated tibial polyethylene insert exchange (ITPIE) to a higher-level constraint would afford similar outcomes to component revision in the properly selected patient. Methods. We retrospectively evaluated 176 consecutive patients between 2016–2017 who were revised for symptomatic instability at a single institution. Demographic information and level of constraint preoperatively and postoperatively were documented. Radiographic parameters were also recorded for patients undergoing ITPIE. Outcome measures included all cause re-revision rates as well as patient reported outcome measures (PROMs) obtained preoperatively and at minimum 1-yr follow up. Descriptive analysis including sample t-test and chi square test were performed with statistical significance set at p <0.05. Results. 100 patients underwent component revision. 76 patients underwent ITPIE. Patients undergoing ITPIE were not found to have gross malalignment, malrotation, compromised fixation or insufficient collateral ligaments. No statistically significant differences were noted in terms of demographic characteristics between the groups. Similar increases in constraint as well as the thickness of the polyethylene were noted at the time of revision surgery in both groups. Further, patients underwent similar rates of re-revision (15.9% for component revision and 11.8% for ITPIE), p=0.8. In analyzing PROMs, no statistically significant differences were noted. Radiographic parameters of those who underwent ITPIE showed majority of patients to have well aligned components. The average follow-up was 2.3(±1.0)yrs for the component revision group and 2.2(±1.1)yrs for the ITPIE group. Conclusion. In the appropriately selected patient, ITPIE offers similar rates of success to component revision including similar re-revision rates and similar improvement in PROMs. Degree of constraint is generally increased and recommended when patients are treated for instability regardless of component revision or ITPIE. Abbreviations. ITPIE - isolated tibial polyethylene insert exchange. PROMs - patient reported outcome measures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 53 - 53
1 Oct 2020
Larson D Rosenberg J Lawlor M Garvin KL Hartman C Lyden E Konigsberg B
Full Access

Introduction. Revision total knee arthroplasty (TKA) is becoming increasingly common in the United States as the population ages and larger numbers of primary TKA are performed in younger individuals. Cemented or uncemented tibial stems are frequently used in revision cases. Decreased clinical outcomes and patient satisfaction have been described for revision TKA. This study aims to determine if the presence of overall pain and tibial pain at the end of the stem differs between cemented and uncemented tibial stems in revision TKA. Methods. This was a retrospective cohort study comparing patients who underwent revision TKA utilizing cemented or uncemented tibial stems in a 15-year period at a single institution with at least two-year follow-up. Exclusion criteria included age under 18, isolated revisions of the femoral component or polyethylene exchanges, lack of preoperative or postoperative imaging, insufficient operative or implant records available for electronic chart review, revision procedures performed at outside facilities, patients who were deceased at the time of survey administration, refusal to participate in the study, and failure to return the mailed survey or respond to a telephone follow-up questionnaire. Radiographic analysis included calculation of the percentage of the tibial canal filled with the implant, as well as measurement of the diameter of the tibial stem. Radiographs were also reviewed for evidence of cavitary defects, pedestal formation, radiolucent lines, and periprosthetic fractures. Mailed surveys addressing overall pain, tibial pain, and satisfaction were analyzed using Fisher's exact test and the independent sample t-test. Logistic regression was used to adjust for age, gender, and preoperative bone loss. Results. A total of 110 patients were included (63 cemented and 47 uncemented stems). No statistically significant differences in stem length, operative side, or indications for revision were found. The uncemented group had a significantly higher percent canal fill (p < 0.0001). Tibial pain at the end of the stem was present in 25.3% of cemented stems and 25.5% of uncemented stems (p = 1.00). There was a trend towards more overall pain in the uncemented cohort, but this did not reach statistical significance. Only 74.6% of cemented patients and 78.7% of uncemented patients were satisfied following revision TKA (p = 0.66). Conclusion. The data supports our hypothesis that there are no differences in end-of-stem pain or overall pain between cemented and uncemented tibial stems in revision TKA. High rates of dissatisfaction were noted in both cohorts postoperatively, consistent with previous literature. Patient factors likely play a large role in the presence of postoperative pain. These factors should be further evaluated in future studies in an effort to reduce pain and improve patient satisfaction


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 61 - 61
1 Oct 2018
Maniar RN Dhiman A Maniar PR Bindal P Gajbhare D
Full Access

Introduction. Patient reported outcome measures (PROMs) are recognized as crucial in evaluating the outcome of total knee arthroplasty (TKA). New Knee Society Score (NKSS), introduced in 2011, is reported to be an effective, such outcome measure. Forgotten Joint score (FJS), introduced in 2012, has been validated but has only a few studies in literature reporting upon it. In a normal population without arthritis, the FJS is reported to be between 50–95, a higher score representing better status. Our aim was to determine 1) the FJS at 1-year post TKA, distributing patients in 2 groups of FJS less than/more than 50; assessing its ceiling and floor effect 2) the influence of age, sex, BMI, diabetes, thyroid, type of deformity, pre/post-operative flexion and 3) to compare and correlate FJS with NKSS and its sub-scores - Objective knee score(OKS) and Subjective knee score(SKS). Methods. We enrolled 181 patients (222 knees), who had primary TKA performed by the same surgeon at Lilavati Hospital & Research Centre, Mumbai, between June 2016 to February 2017. NKSS was administered to each patient preoperatively. At 1 year, they were prospectively called for review and NKSS and FJS were administered. 151 patients attended the review clinic and 17 patients completed the forms with the help of their physiotherapist and sent them via email. 13 patients who could not do either, were excluded from the study. Thus, we had 168 patients (207 knees) whose complete data was analyzed. Of 168 patients, 37 were males and 131 were females, with an average age of 67 years (37–85). Patients were divided into two groups based on their FJS score - Group A (FJS<50) and Group B (FJS≥50). The demographics and NKSS in both groups were compared. The study was approved by our Institutional Review Board. Statistical analysis was done using SPSS software. Raw data statistics for FJS was determined and unpaired t-test used to compare all parameters in Groups A and B. Correlation of NKSS to FJS was analyzed using Pearson's correlation test. Results. 1). FJS at 1 year: The median FJS at 1 year was 68.8 (IQR 41.7, mean 68, SD 25.3, range 0–100). It exhibited a 14% ceiling and 0.5% floor effect. There were 49 (24%) TKAs in Group A and 158 (76%) TKAs in Group B. 2). Comparison of parameters of age, sex, BMI, diabetes, thyroid disorder, type and severity of deformity and pre/post-operative flexion between the two groups showed no difference (unpaired t-test p>0.05) for each parameter, with the numbers available. 3).  . In Group A, the median values of NKSS, OKS and SKS were 174, 94 and 87 respectively as compared to the corresponding median values of 198, 98 and 100 in Group B. The difference in their corresponding values was seen to be significant (p<0.005). For both groups, the change in scores from preoperative to postoperative values was significant for NKSS (median of 73 vs 69, p=0.003) & SKS (median of 39 vs 30, p=0.006) but not for OKS (median of 47 vs 46, p=0.655). Correlation of the FJS to NKSS at 1 year was seen to be significant (p<0.005), the strength of correlation was found to be moderate (r=0.43). Each sub-score also showed significant correlation (p<0.005), which was weak to moderate (r=0.32 to 0.43). Conclusion. Mean FJS at 1-year post TKA was 68 which compares well with a mean of 72 reported in the normal population without arthritis. It exhibited 14% ceiling and 0.5% floor effects. FJS was not influenced by age, sex, BMI, co-morbidities, type/extent of deformity or pre/post-operative flexion range. Patients with higher FJS also had higher NKSS and higher OKS/SKS values but change in scores was significant only for NKSS & SKS. We observed a moderately positive correlation of FJS with NKSS at 1 year


Bone & Joint Open
Vol. 5, Issue 8 | Pages 628 - 636
2 Aug 2024
Eachempati KK Parameswaran A Ponnala VK Sunil A Sheth NP

Aims

The aims of this study were: 1) to describe extended restricted kinematic alignment (E-rKA), a novel alignment strategy during robotic-assisted total knee arthroplasty (RA-TKA); 2) to compare residual medial compartment tightness following virtual surgical planning during RA-TKA using mechanical alignment (MA) and E-rKA, in the same set of osteoarthritic varus knees; 3) to assess the requirement of soft-tissue releases during RA-TKA using E-rKA; and 4) to compare the accuracy of surgical plan execution between knees managed with adjustments in component positioning alone, and those which require additional soft-tissue releases.

Methods

Patients who underwent RA-TKA between January and December 2022 for primary varus osteoarthritis were included. Safe boundaries for E-rKA were defined. Residual medial compartment tightness was compared following virtual surgical planning using E-rKA and MA, in the same set of knees. Soft-tissue releases were documented. Errors in postoperative alignment in relation to planned alignment were compared between patients who did (group A) and did not (group B) require soft-tissue releases.


Aims

The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral.

Methods

The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 240 - 248
1 Mar 2024
Kim SE Kwak J Ro DH Lee MC Han H

Aims

The aim of this study was to evaluate whether achieving medial joint opening, as measured by the change in the joint line convergence angle (∆JLCA), is a better predictor of clinical outcomes after high tibial osteotomy (HTO) compared with the mechanical axis deviation, and to find individualized targets for the redistribution of load that reflect bony alignment, joint laxity, and surgical technique.

Methods

This retrospective study analyzed 121 knees in 101 patients. Patient-reported outcome measures (PROMs) were collected preoperatively and one year postoperatively, and were analyzed according to the surgical technique (opening or closing wedge), postoperative mechanical axis deviation (deviations above and below 10% from the target), and achievement of medial joint opening (∆JLCA > 1°). Radiological parameters, including JLCA, mechanical axis deviation, and the difference in JLCA between preoperative standing and supine radiographs (JLCAPD), an indicator of medial soft-tissue laxity, were measured. Cut-off points for parameters related to achieving medial joint opening were calculated from receiver operating characteristic (ROC) curves.


Aims

The use of high tibial osteotomy (HTO) to delay total knee arthroplasty (TKA) in young patients with osteoarthritis (OA) and constitutional deformity remains debated. The aim of this study was to compare the long-term outcomes of TKA after HTO compared to TKA without HTO, using the time from the index OA surgery as reference (HTO for the study group, TKA for the control group).

Methods

This was a case-control study of consecutive patients receiving a posterior-stabilized TKA for OA between 1996 and 2010 with previous HTO. A total of 73 TKAs after HTO with minimum ten years’ follow-up were included. Cases were matched with a TKA without previous HTO for age at the time of the HTO. All revisions were recorded. Kaplan-Meier survivorship analysis was performed using revision of metal component as the endpoint. The Knee Society Score, range of motion, and patient satisfaction were assessed.


Bone & Joint Open
Vol. 4, Issue 4 | Pages 262 - 272
11 Apr 2023
Batailler C Naaim A Daxhelet J Lustig S Ollivier M Parratte S

Aims

The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients.

Methods

All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m2 (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C’KS angle).


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims

The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design.

Methods

This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.