Advertisement for orthosearch.org.uk
Results 1 - 20 of 394
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 52 - 52
4 Apr 2023
García-Rey E Saldaña L
Full Access

Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of ten years. 343 patients received a THA between 2006 and 2009. All were diagnosed with primary osteoarthritis and their mean age was 63.3 years (range, 56 to 80). 168 were women and 175 men. 250 had no significant lumbar pathology, 76 had significant lumbar pathology and 16 had lumbar fusion. Radiological analysis included sacro-femoral-pubic (SFP), acetabular abduction (AA) and anteversion cup (AV) angles. Measurements were done pre-operatively and at 6 weeks, and at five and ten years post-operatively. Three measurements were recorded and the mean obtained at all intervals. All radiographs were evaluated by the same author, who was not involved in the surgery. There were nine dislocations: six were solved with closed reduction, and three required cup revision. All the mean angles changed over time; the SFP angle from 59.2º to 60º (p=0.249), the AA angle from 44.5º to 46.8º (p=0.218), and the AV angle from 14.7º to 16.2º (p=0.002). The SFP angle was lower in older patients at all intervals (p<0.001). The SFP angle changed from 63.8 to 60.4º in women and from 59.4º to 59.3º in men, from 58.6º to 59.6º (p=0.012). The SFP angle changed from 62.7º to 60.9º in patients without lumbar pathology, from 58.6º to 57.4º in patients with lumbar pathology, and from 57.0º to 56.4º in patients with a lumbar fusion (p=0.919). The SFP cup angle was higher in patients without lumbar pathology than in the other groups (p<0.001), however, it changed more than in patients with lumbar pathology or fusion at ten years after THA (p=0.04). Posterior pelvic tilt changed with aging, influencing the cup position in patients after a THA. Changes due to lumbar pathology could influence the appearance of complications long-term


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective

Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years.

Materials and Methods

A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 57 - 57
1 May 2012
Magill P McGarry J Queally J Morris S McElwain J
Full Access

Introduction. Acetabular fractures are a challenging problem. It has been published that outcome is dependent upon the type of fracture, the reduction of the fracture and concomitant injuries. The end-points of poor outcome include avascular necrosis of the femoral head, osteoarthritis. However, we lack definitive statistics and so counselling patients on prognosis could be improved. In order to achieve this, more outcome studies from tertiary referral centres are required. We present the first long term follow up from a large tertiary referral centre in Ireland. Methods. We identified all patients who were ten years following open reduction and internal fixation of an acetbular fracture in our centre. We invited all of these patients to attend the hospital for clinical and radiographic follow-up. As part of this, three scoring systems were completed for each patient; the Short-form 36 health survey (SF36), the Merle d'Aubigné score and the Short Musculoskeletal Functional Assessment (SMFA). Results. The data represents one year's activity at a new tertiary referral unit. We identified a total of 44 patients who were ten years following ORIF of acetabular fractures in our unit. 21 patients (48%) replied to written invitation and attended the hospital for clinical and radiographic follow-up. A further 7 patients were contacted by telephone and interviewed to gauge their rehabilitation. 3 patients had passed away. The remaining 13 patients were not contactable. Of those who attended in person for follow-up; 18 were male and 3 were female. The mean age at follow-up was 40.5 years (Range 27-60). In terms of fracture pattern epidemiology, 43% of patients sustained posterior column and wall fractures, 29% posterior wall, 14% posterior column alone, 9.5% transverse with posterior wall and 9.5% bicolumnar. 2 patients in the follow-up group had total hip replacements. Of the remaining patients the overall mean SF36 score was 78.8% (SD 16.4). The mean SMFA was 14.1% (SD 5). The mean Merle d'Aubigné score was 14.9 (SD 3.2) with 63% graded as good or excellent. Comparison of outcome between sub-groups according to fracture classification showed no significant difference. Traumatic sciatic nerve injury was sustained by four patients in the follow-up group and all patients continued to complain of ongoing weakness. Of the patients who were contacted via telephone, 2 had total hip replacements. The remaining 5 reported no significant problems with their hips and cited this as the reason for not attending follow-up. Conclusion. Overall the outcome of the patients was more favourable than expected. This was supported by the results of the clinical scoring systems. In some patients this also appeared to be despite poor radiographic findings. Our observations suggest that concomitant injuries, especially sciatic nerve injury have a profound negative influence on the patients' ability to fully rehabilitate. These data provide a valuable tool for the trauma surgeon in providing the patient with an educated prognosis


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 123 - 123
1 Jul 2014
Kerens B Boonen B Schotanus M Kort N
Full Access

Summary Statement. This is the first report of a new technique for unicompartmental to total knee arthroplasty revision surgery in which patient specific guides are formed based on preoperative CT imaging. This technique can help to make revision surgery less technically demanding. Introduction. Unicompartmental to total knee arthroplasty revision surgery can be a technically demanding procedure. Joint line restoration, rotation and augmentations can cause difficulties. This study describes a new technique in which single way fitting guides serve to position knee system cutting blocks. Methods. Preoperatively an image of the distal femur and proximal tibia are formed using CT-scanning. This image is used to create patient specific guides that fit in one single position on the contours of the bone and prosthesis in situ. These guides are fixed with pins and thereafter removed. The pins determine the position of the cutting blocks. Ten consecutive revisions were performed using this technique. Results. All guides fitted well. All femoral prostheses were properly inserted using this technique. One proximal tibia however did not have not enough bonestock so that conversion to intramedular referencing was performed. This was to be expected after the preoperative planning. Postoperative position of the prosthesis was good in all cases. Discussion. This new technique can help to make unicompartmental to total knee arthroplasty less demanding. Problems such as the need for augmentations can be predicted in the preoperative planning. Radiation issues due to CT scanning are limited. The instrumentation needs to be redesigned in order to make this technique work in cases with minimal bonestock present


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 107 - 107
1 Nov 2018
Sheridan G Kelly R McDonnell S Kenny P
Full Access

This was a retrospective study of registry data from a National Orthopaedic Hospital for all THRs with 10-year follow-up data. Inclusion criteria were all THRs with a minimum of 10-year follow-up data. All metal-on-metal (MoM) THRs and MoM resurfacings were excluded from the analysis due to the high rate of revision associated with these bearings. Univariate and multivariate analyses controlling for confounding variables were performed to compare outcomes. A total of 1,697 THRs were performed in 1,553 patients. The four significant predictors for revision were fixation type (p<0.01), surface bearing type (p<0.01), age (P<0.05) and head size (p<0.05). Gender, BMI and approach had no effect on revision rates. The lowest 10-year all-cause revision rates were seen in cemented THRs at 1.7%. Ceramic-on-poly bearings had the lowest revision rate at only 1.2%. Metal-on-poly bearings had a 1.7% revision rate. Ceramic on ceramic bearings had a 7.1% revision rate with 1 revision for squeak and 1 revision for ceramic head fracture. The causes for revision in order of decreasing frequency were as follows: Infection (n=13, 0.7%), dislocation (n=7, 0.4%), periprosthetic fracture (n=3, 0.2%) and aseptic loosening (n=2, 0.1%). There were 2 re-revisions at 10 years in total. The smaller 22.225mm head sizes had a significantly lower revision rate than other head sizes (p<0.05). Ceramic-on-poly bearings, cemented fixation and smaller head sizes perform better in the experience of this registry. However, with multivariate analysis, these differences were shown to be insignificant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 85 - 85
1 May 2012
Abbas G Chuter G Williams J
Full Access

Introduction

Primary Total Elbow Replacement (TER) is gaining popularity as a primary treatment option for osteoporotic fractures of the elbow, particularly in patients with low demand. The aim of this study was to assess the clinical and functional efficacy of TER as a primary treatment for comminuted distal humerus fractures in the elderly.

Methods

We retrospectively reviewed twenty-three patients (22 females and 1 male) who were treated with primary total elbow replacement for complex, intra-articular fractures of the distal humerus in the elderly between March 2000 and January 2010. The average age of the patients was seventy-five years (ranging from 66 to 94 years). Postoperative elbow function was assessed using the Mayo Elbow Performance Score. The radiological assessment was performed using antero-posterior and lateral radiographs done at follow-up appointments.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 61 - 61
17 Apr 2023
Lodewijks L Blokhuis T Poeze M
Full Access

The need for an artificial scaffold in very large bone defects is clear, not only to limit the risk of graft harvesting, but also to improve clinical success. The use of custom osteoconductive scaffolds made from biodegradable polyester and ceramics can be a valuable patient friendly option, especially in case of a concomitant infection. Multiple types of scaffolds for the Masquelet procedure (MP) are available, however these frequently demonstrate central graft involution when defects exceed a certain size and the complication rates remains high. This paper describes three infected tibial defect nonunions with a segmental defect over ten centimeters long treated with a customized 3D printed polycaprolactone-tricalcium phosphate (PCL-TCP) cage in combination with biological adjuncts. Three male patients, between the age of 37 and 47, were treated for an infected tibial defect nonunion after sustaining Gustilo grade 3 open fractures. All had a segmental midshaft bone defect of more than ten centimeters (range 11–15cm). First stage MPs consisted of extensive debridement, external fixation and placement of anterior lateral thigh flaps (ALT). Positive cultures were obtained from all patients during this first stage, that were treated with specific systemic antibiotics during 12 weeks. The second stage MP was carried out at least two months after the first stage. CT scans were obtained after the first stage to manufacture defect-specific cages. In the final procedure a custom 3D printed PCL-TCP cage (Osteopore, Singapore) was placed in the defect in combination with biological adjuncts (BMAC, RIA derived autograft, iFactor and BioActive Glass). Bridging of the defect, assessed at six months by CT, was achieved in all cases. SPECT-scans 6 months post-operatively demonstrated active bone regeneration, also involving the central part of the scaffold. All three patients regained function and reported less pain with full weight-bearing. This case report shows that 3D printed PCL-TCP cages in combination with biological adjuncts is a novel addition to the surgical treatment of very large bone defects in (infected) posttraumatic nonunion of the tibia. This combination could overcome some of the current drawbacks in this challenging indication


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 13 - 13
17 Nov 2023
Armstrong R McKeever T McLelland C Hamilton D
Full Access

Abstract. Objective. There is no specific framework for the clinical management of sports related brachial plexus injuries. Necessarily, rehabilitation is based on injury presentation and clinical diagnostics but it is unclear what the underlying evidence base to inform rehabilitative management. Methods. A systematic review of the literature was undertaken in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We applied the PEO criteria to inform our search strategy to find articles that reported the rehabilitative management of brachial plexus injuries sustained while playing contact sports. An electronic search of Medline, CINAHL, SPORTDiscus and Web of Science from inception to 3rd November 2022 was conducted. MESH terms and Boolean operators were employed. We applied an English language restriction but no other filters. Manual searches of Google Scholar and citation searching of included manuscripts were also completed. All study types were considered for inclusion provided they were published as peer-reviewed primary research articles and contained relevant information. Two investigators independently carried out the searches, screened by title, abstract and full text. Two researchers independently extracted the data from included articles. Data was cross-checked by a third researcher to ensure consistency. To assess internal validity and risk of bias, the Joanna Briggs Institute (JBI) critical appraisal tools were utilised. Results. The search generated 88 articles. Following removal of duplicates, 43 papers were evaluated against the eligibility criteria. Nine were eligible for full text review, with the majority of exclusions being expert opinion articles. Eight case reports were included. One article reported three individuals, resulting in data for ten athletes. The mean age was 19.8 years (±4.09). Injuries occurred in five American football players, two wrestlers, two rugby players, and a basketball player. No two studies applied the same diagnostic terminology and the severity of injury varied widely. Burning pain and altered sensation was the most commonly reported symptom, alongside motor weakness in the upper limb. Clinical presentation and management differed by injury pattern. Traction injuries caused biceps motor weakness and atrophy of the deltoid region, whereas compression injuries led to rotator cuff weakness. In all cases treatment was separated into acute and rehabilitative management phases, however the time frames related to these differed. Acute interventions varied but essentially entailed soft tissue inflammation management. Rehabilitation approaches variously included strengthening of shoulder complex and cervical musculature. Return-to-play criteria was opaque. The methodological quality of the case reports was acceptable. Four met all nine of the JBI evaluation criteria, and a further three met at least 75% of items. Conclusion(s). There is a distinct lack of evidence supporting rehabilitation management of sports related brachial plexus injury. Through systematic review we found only eight reports, representing ten individual case studies. No trials, cohort studies, or even retrospective registry-based studies are available to inform clinical management, which, necessarily, is driven by expert opinion and application of basic rehabilitation principles. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 100 - 100
11 Apr 2023
Salamanna F Brodano G Griffoni C Gasbarrini A Fini M Leggi L
Full Access

Due to the presence of megakaryocytes, platelets and clotting factors, bone marrow aspirate (BMA) tends to coagulate. For the first time, starting from our previous studies on mesenchymal vertebral stem cells, it has been hypothesized that coagulated BMA represents a safe and effective autologous biological scaffold for bone regeneration in spinal surgery. The present research involved advanced preclinical in vitro models and the execution of a pilot clinical study. Evaluation of cell morphology, growth kinetics, immunophenotyping, clonogenicity, trilineage-differentiation, growth-factors and HOX and TALE gene expression were analyzed on clotted- and un-clotted human V-BMA. In parallel, a pilot clinical study on ten patients with degenerative spine diseases submitted to instrumented posterior arthrodesis, is ongoing to assess the ability of clotted-V-BMA to improve spinal fusion at 6- and 12-months follow-up. Results demonstrated that clotted-V-BMA have significantly higher growth-factor expression and mesenchymal stem cell (MSCs) viability, homogeneity, clonogenicity, and ability to differentiate towards the osteogenic phenotype than un-clotted-V-BMA. Clotted-V-BMA also highlighted significant reduced expression of PBX1 and of MEIS3 genes negatively involved in osteoblast maturation and differentiation. From December 2020, eight patients have already been enrolled with first promising results that will be finally evaluated in the next two months. The application of V-BMA-clot as carrier of progenitors and cytokines and as natural scaffold with a structural texture represents a point-of-care orthobiologic product to improve spinal fusion. Clinical application seems to be efficacy, and we will confirm and strengthen these data with the final results of the pilot clinical study


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 132 - 132
11 Apr 2023
van Hoogstraten S Arts J
Full Access

Malalignment is often postulated as the main reason for the high failure rate of total ankle replacements (TARs). Only a few studies have been performed to correlate radiographic TAR malalignment to the clinical outcome, but no consistent trends between TAR alignment parameters and the clinical outcome were found. No standard TAR alignment measurement method is present, so reliable comparison between studies is difficult. Standardizing TAR alignment measurements and increasing measurable parameters on radiographs in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurement on radiographs in the clinic. A tool to semi-automatically measure TAR alignment on anteroposterior and lateral radiographs was developed and used by two observers to measure TAR alignment parameters of ten patients. The Intraclass Coefficient (ICC) was calculated and accuracy was compared to the manual measurement method commonly used in the clinic. The tool showed an accuracy of 76% compared to 71% for the method used during follow-up in the clinic. ICC values were 0.94 (p<0.01) and higher for both inter-and intra-observer reliability. The tool presents an accurate, consistent, and reliable method to measure TAR alignment parameters. Three-dimensional alignment parameters are obtained from two-dimensional radiographs, and as the tool can be applied to any TAR design, it offers a valuable addition in the clinic and for research purposes


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 67 - 67
2 Jan 2024
Belvedere C
Full Access

3D accurate measurements of the skeletal structures of the foot, in physiological and impaired subjects, are now possible using Cone-Beam CT (CBCT) under real-world loading conditions. In detail, this feature allows a more realistic representation of the relative bone-bone interactions of the foot as they occur under patient-specific body weight conditions. In this context, varus/valgus of the hindfoot under altered conditions or the thinning of plantar tissues that occurs with advancing age are among the most complex and interesting to represent, and numerous measurement proposals have been proposed. This study aims to analyze and compare these measurements from CBCT in weight-bearing scans in a clinical population. Sixteen feet of diabetic patients and ten feet with severe adult flatfoot acquired before/after corrective surgery underwent CBCT scans (Carestream, USA) while standing on the leg of interest. Corresponding 3D shapes of each bone of the shank and hindfoot were reconstructed (Materialise, Belgium). Six different techniques found in the literature were used to calculate the varus/valgus deformity, i.e., the inclination of the hindfoot in the frontal plane of the shank, and the distance between the ground and the metatarsal heads was calculated along with different solutions for the identification of possible calcifications. Starting with an accurate 3D reconstruction of the skeletal structures of the foot, a wide range of measurements representing the same angle of hindfoot alignment were found, some of them very different from each other. Interesting correlations were found between metatarsal height and subject age, significant in diabetic feet for the fourth and fifth metatarsal bones. Finally, CBCT allows 3D assessment of foot deformities under loaded conditions. The observed traditional measurement differences and new measurement solutions suggest that clinicians should consider carefully the anatomical and functional concepts underlying measurement techniques when drawing clinical and surgical conclusions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 47 - 47
4 Apr 2023
Knopp B Kushner J Esmaeili E
Full Access

In the field of hand surgery, physicians are working to improve patient satisfaction by offering several minor procedures in the physician's office via the WALANT method. We seek to investigate the degree of patient satisfaction, out of pocket cost, convenience and comfort experienced with in-office hand procedures. A ten question survey consisting of a ten-point Likert scale of agreement and questions asking for a numerical answer was administered via phone call to 33 patients treated with minor hand operations in the office setting in the United States. There were 18 male and 15 female respondents with an average age of 65.59±12.64 years. Respondents underwent procedures including trigger finger release (18), needle aponeurotomy (7), and other minor hand operations. Survey responses indicated strong agreement with questions 1-3 and 6–8, with responses averaging 9.60±0.23 in these positive metrics. Questions 4 and 5, which asked whether the surgery and recovery period were painful, respectively, averaged 2.65±0.49, indicating a mild level of disagreement that either was “painful”. Additionally, most patients responded that they did not take time off work (12) or are not currently employed (11). Other respondents (3) reported taking between one to five days off work post-operatively. 27 respondents also reported an out of pocket cost averaging $382±$976, depending on insurance coverage. Patients reported a small degree of pain in the operative and post-operative period, a high degree of comfort and convenience and a high degree of satisfaction. Likewise, the patient-reported out of pocket cost was far lower than comparable surgical costs in alternate settings. These results support the use of in-office procedures for minor hand surgeries from a patient perspective and indicate a nearly universal intent to repeat any future hand operations in the office setting


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 33 - 33
4 Apr 2023
Pareatumbee P Yew A Koh J Zainul-Abidin S Howe T Tan M
Full Access

To quantify bone-nail fit in response to varying nail placements by entry point translation in straight antegrade humeral nailing using three-dimensional (3D) computational analysis. CT scans of ten cadaveric humeri were processed in 3D Slicer to obtain 3D models of the cortical and cancellous bone. The bone was divided into individual slices each consisting of 2% humeral length (L) with the centroid of each slice determined. To represent straight antegrade humeral nail, a rod consisting of two cylinders with diameters of 9.5mm and 8.5mm and length of 0.22L mm and 0.44L mm respectively joined at one end was modelled. The humeral head apex (surgical entry point) was translated by 1mm in both anterior-posterior and medio-lateral directions to generate eight entry points. Total nail protrusion surface area, maximum nail protrusion distance into cortical shell and top, middle, bottom deviation between nail and intramedullary cavity centre were investigated. Statistical analysis between the apex and translated entry points was conducted using paired t-test. A posterior-lateral translation was considered as the optimal entry point with minimum protrusion in comparison to the anterior-medial translation experiencing twice the level of protrusion. Statistically significant differences in cortical protrusion were found in anterior-medial and posterior-lateral directions producing increased and decreased level of protrusion respectively compared to the apex. The bottom anterior-posterior deviation distance appeared to be a key predictor of cortical breach with the distal nail being more susceptible. Furthermore, nails with anterior translation generated higher anterior-posterior deviation (>4mm) compared to posterior translation (<3mm). Aside from slight posterolateral translation of the entry point from the apex, inclusion of a distal posterior-lateral bend into current straight nail design could improve nail fitting within the curved humeral bone, potentially improving distal working length within the flat and narrow medullary canal of the distal humeral shaft


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 125 - 125
11 Apr 2023
Woodford S Robinson D Lee P Rohrle O Mehl A Ackland D
Full Access

Occlusal loading and muscle forces during mastication aids in assessment of dental restorations and implants and jaw implant design; however, three-dimensional bite forces cannot be measured with conventional transducers, which obstruct the native occlusion. The aim of this study was to combine accurate jaw kinematics measurements, together with subject-specific computational modelling, to estimate subject-specific occlusal loading and muscle forces during mastication. Motion experiments were performed on one male participant (age: 39yrs, weight: 82kg) with healthy dentition. Two low-profile magnetic sensors were fixed to the participant's teeth and the two dental arches digitised using an intra-oral scanner. The participant performed ten continuous of chewing on a polyurethane rubber sample of known material properties, followed by maximal compression (clenching). This was repeated at the molars, premolars of both the left and right sides, and central incisors. Jaw motion was simultaneously recorded from the sensors, and finite element modelling used to estimate bite force. Specifically, simulations of chewing and biting were performed by driving the model using the measured kinematics, and bite force magnitude and direction quantified. Muscle forces were then evaluated using a rigid-body musculoskeletal model of the patient's jaw. The first molars generated the largest bite forces during chewing (left: 309 N, right: 311 N) and maximum-force biting (left: 496 N, right: 495 N). The incisors generated the smallest bite forces during chewing (75 N) and maximum-force biting (114 N). The anterior temporalis and superficial masseter muscles had the largest contribution to maximum bite force, followed by the posterior temporalis and medial pterygoid muscles. This study presents a new method for estimating dynamic occlusal loading and muscle forces during mastication. These techniques provide new knowledge of jaw biomechanics, including muscle and occlusal loading, which will be useful in surgical planning and jaw implant design


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 113 - 113
2 Jan 2024
Ghaffari A Rasmussen J Kold S Rahbek O
Full Access

Gait measurements can vary due to various intrinsic and extrinsic factors, and this variability becomes more pronounced using inertial sensors in a free-living environment. Therefore, identifying and quantifying the sources of variability is essential to ensure measurement reliability and maintain data quality. This study aimed to determine the variability of daily accelerations recorded by an inertial sensor in a group of healthy individuals. Ten participants, four males and six females, with a mean age of 50 years (range: 29–61) and BMI of 26.9 kg/m. 2. (range: 21.4–36.8), were included. A single accelerometer continuously recorded lower limb accelerations over two weeks. We extracted and analyzed the accelerations of three consecutive strides within walking bouts if the time difference between the bouts was more than two hours. Multivariate mixed-effects modeling was performed on both the discretized acceleration waveforms at 101 points (0–100) and the harmonics of the signals in the frequency domain to determine the variance components for different subjects, days, bouts, and steps as the random effect variables. Intraclass correlation coefficients (ICCs) were calculated for between-day, between-bout, and between-step comparisons. The results showed that the ICCs for the between-day, between-bout, and between-step comparisons were 0.73, 0.82, 0.99 for the vertical axis; 0.64, 0.75, 0.99 for the anteroposterior axis; and 0.55, 0.96, 0.97 for the mediolateral axis. For the signal harmonics, the respective ICCs were 0.98, 0.98, 0.99 for the vertical axis; 0.54, 0.93, 0.98 for the anteroposterior axis; and 0.69, 0.78, 0.95 for the mediolateral axis. Overall, this study demonstrated that accelerations recorded continuously for multiple days in a free-living environment exhibit high variability, mainly between days, and some variability arising from differences between walking bouts during different times within days. However, reliable and repeatable gait measurements can be obtained by identifying and quantifying the sources of variability


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 84 - 84
4 Apr 2023
Gehweiler D Pastor T Beeres F Kastner P Migliorini F Nebelung S Scaglioni M Souleiman F Link B Babst R Gueorguiev B Knobe M
Full Access

Helical plates potentially bypass the medial neurovascular structures of the thigh. Recently, two plate designs (90°- and 180°-helix) proved similar biomechanically behaviour compared to straight plates. Aims of this study were: (1) Feasibility of MIPO-technique with 90°- and 180°-helical plates on the femur, (2) Assessment of distances to adjacent anatomical structures at risk, (3) Comparison of these distances to using medial straight plates instead, (4) Correlation of measurements performed in anatomic dissection with CT-angiography. MIPO was performed in ten cadaveric femoral pairs using either a 90°-helical 14-hole-LCP (Group1) or a 180°-helical 15-hole-LCP-DF (Group2). CT angiography was used to evaluate the distances between the plates and the femoral arteries as well as the distances between the plates and the perforators. Subsequently, the specimens were dissected, and the distances were determined again manually. Finally, all helical plates were removed, and all measurements were repeated after application of straight medial plates (Group3). Closest overall distances between plates and femoral arteries were 15 mm (11 − 19 mm) in Group1, 22 mm (15 − 24 mm) in Group2 and 6 mm (1 − 8 mm) in Group3 with a significant difference between Group1 and Group3 (p < 0.001). Distances to the nearest perforators were 24 mm (15 − 32 mm) in Group1 and 2 mm (1 − 4 mm) in Group2. Measurement techniques (visual after surgery and CT-angiography) demonstrated a strong correlation of r. 2. = 0.972 (p < 0.01). MIPO with 90°- and 180°-helical plates is feasible and safe. Attention must be paid to the medial neurovascular structures with 90°-helical implants and to the proximal perforators with 180°-helical implants. Helical implants can avoid medial neurovascular structures compared to straight plates although care must be taken during their distal insertion. Measurements during anatomical dissection correlate with CT-angiography


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 80 - 80
14 Nov 2024
Møller S
Full Access

Introduction. Plantar heel pain, or plantar fasciopathy (PF), is a common musculoskeletal complaint, affecting 39% of lower-extremity tendinopathies in general practice. Conservative management is recommended as the first-line treatment, yet many patients continue to experience symptoms even after ten years. There is a significant lack of high-quality evidence for the effectiveness of various treatments, highlighting the need for more research. Minimally invasive surgical options, such as endoscopic plantar fascia release and radiofrequency microtenotomy, have shown promise in reducing pain and improving outcomes. This systematic review aims to evaluate the effectiveness of these minimally invasive surgical treatments compared to non-surgical options in managing PF. Method. The systematic review, registered on PROSPERO (CRD42024490498) and adhering to PRISMA guidelines, searched databases including PubMed, Embase, Cochrane, and others for studies from January 1991 to May 2024. Keywords included plantar fasciitis, plantar fasciopathy, and heel pain. Limited to human trials, the search strategy was refined with an information specialist and found no protocol duplicates. Result. The systematic review identified eight studies involving 495 patients (56.2% women, average age 46.5 years). The studies compared various treatments, including endoscopic plantar fascia release (EPF), mini-scalpel needle (MSN) treatment, ultrasound-guided pulsed radiofrequency (UG-PRF), and needle electrolysis (NE), to non-surgical interventions and corticosteroid injections (CSI). Primary outcomes focused on pain reduction, with some needle treatments showing superior results (between-group diffence). No severe adverse events were reported. Conclusion. In conclusion, plantar fasciopathy (PF) remains a prevalent and challenging condition, that can be resistant to conservative treatments. This systematic review highlights the potential of minimally invasive surgical options, such as endoscopic plantar fascia release and needle treatments, in reducing pain and improving functional outcomes. Despite some needle treatments showing superior results, the overall lack of high-quality evidence underscores the need for further research to establish the most effective management strategies for PF


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 137 - 137
11 Apr 2023
Quinn A Pizzolato C Bindra R Lloyd D Saxby D
Full Access

There is currently no commercially available and clinically successful treatment for scapholunate interosseous ligament rupture, the latter leading to the development of hand-wrist osteoarthritis. We have created a novel biodegradable implant which fixed the dissociated scaphoid and lunate bones and encourages regeneration of the ruptured native ligament. To determine if scaphoid and lunate kinematics in cadaveric specimens were maintained during robotic manipulation, when comparing the native wrist with intact ligament and when the implant was installed. Ten cadaveric experiments were performed with identical conditions, except for implant geometry that was personalised to the anatomy of each cadaveric specimen. Each cadaveric arm was mounted upright in a six degrees of freedom robot using k-wires drilled through the radius, ulna, and metacarpals. Infrared markers were attached to scaphoid, lunate, radius, and 3rd metacarpal. Cadaveric specimens were robotically manipulated through flexion-extension and ulnar-radial deviation by ±40° and ±30°, respectively. The cadaveric scaphoid and lunate kinematics were examined with 1) intact native ligament, 2) severed ligament, 3) and installed implant. Digital wrist models were generated from computed tomography scans and included implant geometry, orientation, and location. Motion data were filtered and aligned relative to neutral wrist in the digital models of each specimen using anatomical landmarks. Implant insertion points in the scaphoid and lunate over time were then calculated using digital models, marker data, and inverse kinematics. Root mean squared distance was compared between severed and implant configurations, relative to intact. Preliminary data from five cadaveric specimens indicate that the implant reduced distance between scaphoid and lunate compared to severed configuration for all but three trials. Preliminary results indicate our novel implant reduced scapho-lunate gap caused by ligament transection. Future analysis will reveal if the implant can achieve wrist kinematics similar to the native intact wrist


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 94 - 94
11 Apr 2023
Funk G Horn E Kilway K Parrales A Iwakuma T McIff T
Full Access

Osteosarcoma and other types of bone cancers often require bone resection, and backfill with cement. A novel silorane-based cement without PMMA's drawbacks, previously developed for dental applications, has been reformulated for orthopedic use. The aim of this study is to assess each cement's ability to elute doxorubicin, maintain its potency, and maintain suitable weight-bearing strength. The silorane-based epoxy cement was synthesized using a platinum-based Lamoreaux's catalyst. Four groups of cement were prepared. Two PMMA groups, one without any additives, one with 200 mg of doxorubicin. Two silorane groups: one without any additive, one with doxorubicin, added so that the w% of drug into both cements were equal. Pellets 6 × 12 mm were used for testing (ASTM F451). n=10. Ten pellets from each group were kept dry. All others were placed into tubes containing 2.5 mL of PBS and stored at 37 °C. Elution from doxorubicin-containing groups were collected every day for 7 days, with daily PBS changeout. Antibiotic concentrations were determined via HPLC. Compressive strength and compressive modulus of all groups were determined for unsoaked specimens, and those soaked for 7 and 14 days. MTT assays were done using an MG63 osteosarcoma cell line. Both cements were able to elute doxorubicin over 7 days in clinically-favorable quantities. For PMMA samples, the incorporation of doxorubicin was shown to significantly affect the compressive strength and modulus of the samples (p<0.01). Incorporation of doxorubicin into silorane had no significant effect on either (p>.05). MTT assays indicated that doxorubicin incorporated into the silorane cement maintained its effectiveness whereas that into PMMA did not. At the dosing used, both cements remained above the 70 MPa. Both PMMA and silorane-based cements can deliver doxorubicin. Doxorubicin, however, interacts chemically with PMMA, inhibiting polymerization and lowering the chemotherapeutic's effectiveness


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 126 - 126
2 Jan 2024
Escudero-Duch C Serrano-Yamba R Sánchez-Casanova S Falguera-Uceda M Yus C Lerma-Juárez M Arruebo M Vilaboa N
Full Access

In this work, we combined tissue engineering and gene therapy technologies to develop a therapeutic platform for bone regeneration. We have developed photothermal fibrin-based hydrogels that incorporate degradable CuS nanoparticles (CuSNP) which transduce incident near-infrared (NIR) light into heat. A heat-activated and rapamycin-dependent transgene expression system was incorporated into mesenchymal stem cells to conditionally control the production of bone morphogenetic protein 2 (BMP-2). Genetically engineered cells were entrapped in the photothermal hydrogels. In the presence of rapamycin, photoinduced mild hyperthermia induced the release of BMP-2 from the NIR responsive cell constructs. Transcriptome analysis of BMP-2 expressing cells showed a signature of induced genes related to stem cell proliferation and angiogenesis. We next generated 4 mm diameter calvarial defects in the left parietal bone of immunocompetent mice. The defects were filled with NIR-responsive hydrogels entrapping cells that expressed BMP-2 under the control of the gene circuit. After one and eight days, rapamycin was administered intraperitoneally followed by irradiation with an NIR laser. Ten weeks after implantation, the animals were euthanized and samples from the bone defect zone were processed for histological analysis using Masson's trichrome staining and for immunohistochemistry analyses using specific CD31 and CD105 antibodies. Samples from mice that were only administered rapamycin or vehicle or that were only NIR-irradiated showed the persistence of fibrous tissue bridging the defect. In animals that were treated with rapamycin, NIR irradiation of implants resulted in the formation of new mineralized tissue with a high degree of vascularization, thus indicating the therapeutic potential of the approach. Acknowledgements: This research was supported by grants RTI2018-095159-B-I00 and PID2021-126325OB-I00 (MCIN/AEI/10.13039/501100011033 and “ERDF A way of making Europe”), by grant P2022/BMD- 7406 (Regional Government of Madrid). M.A.L-J. is the recipient of predoctoral fellowship PRE2019-090430 (MCIN/AEI/10.13039/501100011033)