Advertisement for orthosearch.org.uk
Results 1 - 20 of 49
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 69 - 69
1 Dec 2021
MacLeod A Taylor R Casonato A Gill H
Full Access

Abstract

Objectives

Additive manufacturing has led to numerous innovations in orthopaedic surgery: surgical guides; surface coatings/textures; and custom implants. Most contemporary implants are made from titanium alloy (Ti-6Al-4V). Despite being widely available industrially and clinically, there is little published information on the performance of this 3D printed material for orthopaedic devices with respect to regulatory approval. The aim of this study was to document the mechanical, chemical and biological properties of selective laser sintering (SLS) manufactured specimens following medical device (TOKA®, 3D Metal Printing LTD, UK) submission and review by the UK Medicines and Healthcare Products Regulatory Agency (MHRA).

Methods

All specimens were additively manufactured in Ti-6Al-4V ELI (Renishaw plc, UK). Mechanical tests were performed according to ISO6892-1, ISO9585 and ISO12107 for tensile (n=10), bending (n=3) and fatigue (n=16) respectively (University of Bath, UK). Appropriate chemical characterisation and biological tests were selected according to recommendations in ISO10993 and conducted by external laboratories (Wickham Labs, UK; Lucideon, UK; Edwards Analytical, UK) in adherence with Good Lab Practise guidelines. A toxicological review was conducted on the findings (Bibra, UK).


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 720 - 725
1 Jul 1998
Sano H Uhthoff HK Backman DS Brunet JA Trudel G Pham B Ishii H

We examined macroscopically and microscopically 55 cadaver rotator-cuff tendons attached to their humeral heads to determine the distance between the edge of the articular cartilage and the tendon insertion of the supraspinatus (the width of the sulcus) and the score of regressive changes at the sulcus. In 33 specimens we measured the tensile strength. The width of the sulcus was correlated with the score of regressive changes and with the ultimate tensile strength of the supraspinatus tendon. The width of the sulcus correlated positively with the score of regressive changes (r = 0.66, p < 0.0001), but there was a negative correlation between the latter and the ultimate tensile strength (r = −0.81, p = 0.001) and between the width of the sulcus and the ultimate tensile strength (r = −0.74, p = 0.004). We believe that the width of the sulcus is a simple and useful clinical indicator of the integrity and the tensile strength of the supraspinatus tendon


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 82 - 82
4 Apr 2023
Kokozidou M Gögele C Pirrung F Hammer N Werner C Kohl B Hahn J Breier A Schöpfer M Meyer M Schulze-Tanzil G
Full Access

Although autografts represent the gold standard for anterior cruciate ligament (ACL) reconstruction, tissue-engineered ACLs provide a prospect to minimize donor site morbidity and limited graft availability. This given study characterizes the ligamentogenesis in embroidered poly(L-lactide-co-ε-caprolactone) (P(LA-CL)) / polylactic acid (PLA) constructs using a dynamic nude mice xenograft model. (P(LA-CL))/PLA scaffolds remained either untreated (co) or were functionalized by gas fluorination (F), collagen foam cross-linked with hexamethylene diisocyanate (HMDI) (coll), or gas fluorination combined with the foam (F+coll). Cell free constructs or those seeded for 1 week with lapine ACL ligamentocytes were implanted into nude mice for 12 weeks. Following explantation, biomechanical properties, cell vitality and content, histopathology of scaffolds (including organs: liver, kidney, spleen), sulphated glycosaminoglycan (sGAG) contents and biomechanical properties were assessed. Implantation of the scaffolds did not negatively affect mice weight development and organs, indicating biocompatibility. All scaffolds maintained their size and shape for the duration of the implantation. A high cell viability was detected in the scaffolds prior to and following implantation. Coll or F+coll scaffolds seeded with cells yielded superior macroscopic properties when compared to the controls. Mild signs of inflammation (foreign-body giant cells, hyperemia) were limited to scaffolds without collagen. Microscopical score values and sGAG content did not differ significantly. Although remaining stable in vivo, elastic modulus, maximum force, tensile strength and strain at Fmax were significantly lower in the in vivo compared to the samples cultured 1 week in vitro, but did not differ between scaffold subtypes, except for a higher maximum force in F+coll compared with F samples (in vivo). Scaffold functionalization with fluorinated collagen foam provides a promising approach for ACL tissue engineering. (shared first authorship). Acknowledgement: The study was supported by DFG grants SCHU1979/9-1 and SCHU1979/14-1


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 24 - 24
11 Apr 2023
Solis J Edwards J Fermor H Riches P Brockett C Herbert A
Full Access

Decellularised porcine superflexor tendon (pSFT) has been demonstrated to be a suitable scaffold for anterior cruciate ligament reconstruction[1]. While the role of collagen in tendons is well known, the mechanical role of glycosaminoglycans (GAGs) is less clear and may be altered by the decellularisation process. To determine the effects of decellularisation on pSFT GAG content and mechanical function and to investigate the consequences of GAG loss in tensile and compressive loading. pSFTs were decellularised following previous techniques [2]. For GAG removal, native pSFTs were treated with chondroitinase ABC (ChABC; 0.1U/mL, 72h). Cell and GAG removal was validated using histology and quantitative assays. Native, decellularised and ChABC treated groups (n=6) were biomechanically characterised. In tension, specimens underwent stress relaxation and strength testing using previous protocols [1]. Stress relaxation data was fitted to a modified Maxwell-Weichert model to determine time-dependent (E1 & E2) and time-independent moduli (E0). The toe and linear region moduli (Etoe, Elinear), in addition to tensile strength (UTS) and failure strain were determined from strength testing. In compression, specimens underwent confined loading conditions (ramp at 10 s-1 to 10% strain and hold). The aggregate modulus (HA) and zero-strain permeability (k0) were determined using previous techniques [3]. Data was analysed by one-way ANOVA with Tukey post-hoc test to determine significant differences between test groups (p<0.05). Quantitative assays showed no GAG reduction post-decellularisation, but a significant reduction after ChABC treatment. HA was only significantly reduced in the ChABC group. k0 was significantly higher for the ChABC group compared to decellularised. E0 was significantly reduced in the decellularised group compared to native and ChABC groups, while E1 and E2 were not different between groups. Etoe, Elinear, UTS and failure strain were not different between groups. Decellularisation does not affect GAG content or impair mechanical function in pSFT. GAG loss adversely affects pSFT compressive properties, revealing major mechanical contribution under compression, but no significant role under tension


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 24 - 24
1 Jul 2014
Morrey M Lostis E Franklin S Hakimi O Mouthy P Baboldashti NZ Carr A
Full Access

Summary Statement. A novel biomimetic polydioxanone tendon patch with woven and electrospun components is biocompatible, recapitulates native tendon architecture and creates a tissue-healing microenvironment directed by a subpopulation of regenerative macrophages. The woven component provides tensile strength while the tendon heals. Introduction. There is great interest in the use of biomimetic devices to augment tendon repairs. Ideally, implants improve healing without causing adverse local or systemic reactions. Biocompatibility remains a critical issue prior to implantation into humans, as some implants elicit a foreign body response (FBR) involving inflammation, poor wound healing and even fistulae formation. Additionally, the effect on articular cartilage locally or systemically with placement of a juxta-articular implant has not been examined. The purpose of this study is to test the in vivo biocompatibility of a novel hybrid woven and electrospun polydioxanone patch in a rat tendon transection model. Patients and Methods. Sixty Lewis rats were divided into 4 groups in which the infraspinatus was surgically transected 3 mm from its insertion. Tendons were repaired with a woven and electrospun polydioxanone patch (PDOe) and 5-0 Prolene sutures. Vicryl and Silk patches or a simple Prolene suture repair served as comparators. Animals were sacrificed at 1, 2, 4, 6 and 12 weeks to examine the biocompatibility of the implants. Immunohistochemistry was used to examine macrophage subpopulations and hematoxylin and eosin staining was used to assess foreign-body giant cells and both analyzed with a one-way ANOVA with significance set at p<.05. Articular cartilage was scrutinised with semi-quantitative analysis. Hind paw inflammatory indices were used to determine the systemic effects and biomechanical testing the tensile strength of the materials over time. Results. The PDOe patch remained grossly quiescent at all time-points. There was a severe inflammatory reaction to Vicryl at one and 2-week time-points with gross exudate. Silk patches were associated with larger fibrous capsules at each time point. There were no adverse systemic effects and articular cartilage remained normal with no differences between materials to controls. Immunohistochemistry showed a significantly higher ratio of regenerative to inflammatory macrophages for the PDOe patch compared to other constructs at each time-point and similar to controls. Silk and Vicryl patches had a greater than 10-fold increase in foreign-body giant cells compared to the PDOe patch and controls (p<.05) suggesting incorporation rather than rejection and walling off of the biomaterial. Tensile strength of the PDOe patch increased in the first 2 weeks to greater than 90 N and gradually declined to a mean of 22 N at 12 weeks. Discussion/Conclusion. The novel PDOe patch appears to be biocompatible and illicit very little FBR in this rat tendon injury model. Importantly, there was no joint reaction to the biomaterial which has not been addressed previously. We believe the electrospun component of the patch recapitulates native tendon architecture creating a tissue healing microenvironment directed by a regenerative macrophage subpopulation. These results corroborate earlier in vitro work that showed incorporation of tenocytes within the electrospun scaffold. The woven component of the scaffold provides tensile strength as the tendon heals and begins to degrade after healing is underway making it less likely to elicit a FBR. Based on these and earlier in vitro data we believe this implant shows excellent biocompatibility and is ready to proceed to human trials


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 74 - 74
1 Dec 2021
Chen H Khong J Huang J
Full Access

Abstract. Objectives. Direct ink writing (DIW) has gained considerable attention in production of personalized medical implants. Laponite nanoclay is added in polycaprolactone (PCL) to improve printability and bioactivity for bone implants. The 3D structure of DIW printed PCL/Laponite products was qualitatively evaluated using micro-CT. Methods. PCL/LP composite ink was formulated by dissolving 50% m/v PCL in dichloromethane with Laponite loading of up to 30%. The rheological properties of the inks were determined using Discovery HR-2 rheometer. A custom-made direct ink writer was used to fabricate both porous scaffold with 0°/90° lay-down pattern, and solid dumbbell-shaped specimens (ASTM D638 Type IV) with two printing orientations, 0° and 90° to the loading direction in tensile testing. The 3D structure of specimens was assessed using a micro-CT. Independent t-tests were performed with significance level at p<0.05. Results. The addition of Laponite in PCL ink has significantly enhanced viscosity for shape fidelity and shear-thinning property facilitating extrusion for DIW. Uniform distribution of Laponite was illustrated by micro-CT. For the 32-layer scaffold, interconnectivity of pores is observed at all 3 planes. The variation of height and width of layers is within 6% except the bottom 2 layers which are significantly lower and wider than other layers for mechanical support. For solid specimens, no ditches/interfaces between filaments are observed in 90° orientation while they are distinctive in 0° orientation because deposited filaments contact each other sooner in 90° orientation. 90° specimens also have lower air gap fraction (0.8 vs 5.4 %) and significantly higher Young's modulus (235 vs 195 MPa) and tensile strength (12.0 vs 9.5 MPa). Conclusions. The mechanical properties and printability of PCL/Laponite composites can be improved by controlling printing parameters; Micro-CT is an important tool to investigate the structure and properties of 3D printed products for bone tissue engineering


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 45 - 45
1 Dec 2021
Lu V Tennyson M Zhang J Khan W
Full Access

Abstract. Objectives. Tendon and ligament injury poses an increasingly large burden to society. With surgical repair and grafting susceptible to high failure rates, tissue engineering provides novel avenues for treatment. This systematic review explores in vivo evidence whether mesenchymal stem cell-derived extracellular vesicles (MSC-EVs) can facilitate tendon and ligament repair in animal models. Methods. On May 26th 2021, a systematic search was performed on PubMed, Web of Science, Cochrane Library, Embase, using search terms ‘mesenchymal stem cell’ or ‘multipotent stem cell’ AND ‘extracellular vesicles’ or ‘exosomes’ AND ‘tendon’ or ‘ligament’ or ‘connective tissue’. Risk of bias was assessed using SYstematic Review Center for Laboratory animal Experimentation (SYRCLE) tool. Studies administering EVs isolated from human or animal-derived MSCs into in vivo models of tendon/ligament injury were included. In vitro, ex vivo, in silico studies were excluded, and studies without a control group were excluded. Data on isolation and characterisation of MSCs and EVs, and in vivo findings in animal models were extracted. Results. Out of 383 relevant studies, 11 case-control studies were included for data extraction, including a total of 448 animal subjects (range 10–90). Six studies utilised bone marrow-derived MSCs. All studies characterised their MSCs via flow cytometry, which expressed CD44 and CD90, and isolated EVs via ultracentrifugation (average diameter 125nm). Five studies utilised histological scoring systems, all of which reported a lower score with EV treatment, suggesting improved healing ability. Four studies reported increased anti-inflammatory cytokine expression (IL-10, TGF-β1); three studies reported decreased endogenous M1/M2 macrophage ratio with EV treatment. Eight studies reported increased maximum stiffness, breaking load, tensile strength in EV-treated tendons. Conclusion. MSC-EVs are effective therapeutic agents for tendon/ligament pathologies, attenuating the initial inflammatory response, and accelerating tendon matrix regeneration. Future randomised controlled trials are needed to definitely demonstrate MSC-EVs superiority in management of tendon/ligament injury


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 41 - 41
1 Apr 2018
Kara A Kizmazoglu C Husemoglu B Bilici G Kocturk S Havitcioglu H
Full Access

Dura mater is a thick membrane that is the outermost of the three layers of the meninges that surround the brain and spinal cord. Appropriate dural healing is crucial to prevent cerebrospinal fluid leaks but the entire process has been barely understood so far. Understanding of dural healing and tissue neoformation over the dural grafts, which are usually used for duraplasty, is still partial. Therefore, implantation of decellular dura mater (DM) to recipient from different donor and vitalization with recipient”s mesenchymal stem cells for the treatment of tissue on transplantation process is significant approach. This approach prevents immunological reactions and provides long-term stabilization. According to this study, it is believed that this approach will provide DM healing and become crucial in DM transplantation. The aim of this study was to develop a new construct by tissue engineering of the human DM based on a decellular allograft. Thus human DM collected from forensic medicine and decellularized using the detergent sodium dodecyl sulfate (SDS) in the multiple process of physical, enzimatic and chemical steps. Decellularization were exposing the tissue to freeze-thaw cycles, incubation in hypotonic tris-HCl buffer, 0.1% (w/v) SDS in hypotonic buffer and hypertonic buffer followed by disinfection using 0.1% (v/v) peracetic acid and final washing in phosphate-buffered saline. As a result of all these processes, cellular components of DM were removed by preserving the extracellular matrix without any significant loss in mechanical properties. Based on the histological analysis of the decellularized DM revealed the absence of visible whole cells. Collagen and glycosaminoglycan (GAG) contents of decellular DM evaluated histological staining by Masson Trichrome and Alcian blue respectively. Also biochemical tests were carried out by spectrophotometry (Quickzym Biosciences, The Netherlands) and total GAG content were analyzed by 1.9 dimethylmethylene blue assay. The histoarchitecture was unchanged, and there were no significant changes of total collagen and GAG content. Biomechanical properties were determined by tensile tests, which has confirmed the retention of biomechanical properties following decellularization. The mean tensile strengths were 7,424±4,20 MPa for control group, 5,254±2,068 MPa for decellularization group. There was no statistically significant difference between tensile strength (p=0,277) and tissue thickness (p=0, 520) for both group. In conclusion, this study has developed biomechanically functional decellularized DM scaffold for use in DM repair. In addition, this study is a part of the progressing study and additional studies investigating the biocompatibility performance of the decellularized DM scaffold and there is need for in vivo studies. Keywords. Dura mater, Decellularization, Allografts, Scaffolds, Tissue Engineering


Bone & Joint Research
Vol. 6, Issue 2 | Pages 82 - 89
1 Feb 2017
Nagra NS Zargar N Smith RDJ Carr AJ

Objectives. All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. Materials and Methods. A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05. Results. Overall, mean maximum tensile strength values were significantly higher for the traditional anchor (181.0 N, standard error (. se). 17.6) compared with the all-suture anchors (mean 133.1 N . se. 16.7) (p = 0.04). The JuggerKnot anchor had greatest displacement at 50, 100 and 150 cycles, and at failure, reaching statistical significance over the control at 100 and 150 cycles (22.6 mm . se. 2.5 versus 12.5 mm . se. 0.3; and 29.6 mm . se. 4.8 versus 17.0 mm . se. 0.7). Every all-suture anchor tested showed substantial (> 5 mm) displacement between 50 and 100 cycles (6.2 to 14.3). All-suture anchors predominantly failed due to anchor pull-out (95% versus 25% of traditional anchors), whereas a higher proportion of traditional anchors failed secondary to suture breakage. Conclusion. We demonstrate decreased failure load, increased total displacement, and variable failure mechanisms in all-suture anchors, compared with traditional anchors designed for rotator cuff repair. These findings will aid the surgeon’s choice of implant, in the context of the clinical scenario. Cite this article: N. S. Nagra, N. Zargar, R. D. J. Smith, A. J. Carr. Mechanical properties of all-suture anchors for rotator cuff repair. Bone Joint Res 2017;6:82–89. DOI: 10.1302/2046-3758.62.BJR-2016-0225.R1


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_11 | Pages 27 - 27
1 Oct 2015
Rowson D Knight M Screen H
Full Access

Introduction. Primary cilia are organelles found singularly on almost every cell in the body, including tenocytes. Tendon is a hierarchical, composite structure, and previous work from our group has suggested that the cell populations in the inter-fascicular matrix (IFM) may be different from those within the fascicle matrix (FM). This study investigated how stress deprivation influenced the primary cilia of both cell types, and the mechanics of the IFM and the FM. Materials and Methods. Rat tail tendons were dissected and then either tested immediately (fresh), or maintained in media for 1 week, either stress deprived or at 4% static strain. Fascicles and IFM were then either, fixed and imaged to determine cilia length (n = 80–160 cilia per group from across 3 rats), or mechanically tested to determine the static and viscoelastic properties of both the fascicles and the IFM (n = 6–8 per group). Results. Cilia length in the IFM and FM of fresh samples were not significantly different. After 1 week of stress deprivation, the cilia had significantly increased in length in both the IFM and FM, however the increase in length in the IFM was significantly greater than that in the FM. Cilia in tissue maintained at 4% static strain were significantly shorter than those in stress deprived tissue, however they remained longer than those in fresh tissue. The tensile strength of the fascicles was not affected by stress deprivation or static strain conditions. However, the viscoelastic properties of the stress deprived fascicles were significantly reduced. By contrast, the tensile strength of the IFM was significantly reduced in the stress deprived samples, indicative of greater degradation in this region. Discussion. This is the first time differences in the cilia have been observed between tendon regions. Their different response to stress deprivation provides further evidence that these populations of cells respond differently to changes in mechanical stimulation. Cilia length increased more in the region where there was more mechanical degradation, suggesting that cilia are responding to their local mechanical environment


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 889 - 893
1 Jun 2010
Kocaoglu B Agir I Nalbantoglu U Karahan M Türkmen M

We investigated the effect of mitomycin-C on the reduction of the formation of peritendinous fibrous adhesions after tendon repair. In 20 Wistar albino rats the tendo Achillis was cut and repaired using a modified Kessler technique. The rats were divided into two equal groups. In group 1, an injection of mitomycin-C was placed between the tendon and skin of the right leg. In group 2, an identical volume of sterile normal saline was injected on the left side in a similar fashion. All the rats received mitomycin-C or saline for four weeks starting from the day of operation. The animals were killed after 30 days. The formation of peritendinous fibrous tissue, the inflammatory reaction and tendon healing were evaluated. The tensile strength of the repaired tendons was measured biomechanically. Microscopic evidence of the formation of adhesions and inflammation was less in group 1. There was no significant difference in the tensile load required to rupture the repaired tendons in the two groups. Mitomycin-C may therefore provide a simple and inexpensive means of preventing of post-operative adhesions


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1392 - 1400
1 Oct 2008
Hayashi R Kondo E Tohyama H Saito T Yasuda K

We report the effects of local administration of osteogenic protein-1 on the biomechanical properties of the overstretched anterior cruciate ligament in an animal model. An injury in the anterior cruciate ligament was created in 45 rabbits. They were divided into three equal groups. In group 1, no treatment was applied, in group II, phosphate-buffered saline was applied around the injured ligament, and in group III, 12.5 μg of osteogenic protein-1 mixed with phosphate-buffered saline was applied around the injured ligament. A control group of 15 rabbits was assembled from randomly-selected injured knees from among the first three groups. Each rabbit was killed at 12 weeks. The maximum load and stiffness of the anterior cruciate ligament was found to be significantly greater in group III than either group 1 (p = 0.002, p = 0.014) or group II (p = 0.032, p = 0.025). The tensile strength and the tangent modulus of fascicles from the ligament were also significantly greater in group III than either group I (p = 0.002, p = 0.0174) or II (p = 0.005, p = 0.022). The application of osteogenic protein-1 enhanced the healing in the injured anterior cruciate ligament, but compared with the control group the treated ligament remained lengthened. The administration of osteogenic protein-1 may have a therapeutic role in treating the overstretched anterior cruciate ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 440 - 446
1 Apr 2002
Tohyama H Yasuda K

We performed a biomechanical and histological study to clarify the effect of stress enhancement on the in situ frozen-thawed patellar tendon of the rabbit as a tendon autograft model. We used 48 Japanese White rabbits divided into three groups. In group 1, the patellar tendon underwent in situ freeze-thaw treatment with liquid nitrogen to kill intrinsic fibroblasts. In group 2, after similar treatment, the medial and lateral portions were resected so that the cross-sectional area was reduced by a third. In group 3, after treatment, the cross-sectional area was reduced by a half. In groups 2 and 3, the stress in the tendon was calculated theoretically to be 150% and 200% of the physiological stress during locomotion. Eight rabbits in each group were killed at three and six weeks, respectively. At three weeks, the mean values for the tensile strength of groups 2 and 3 were 113.7% and 75.7% of that of group 1, and at six weeks 101.2% and 57.4%, respectively. The tensile strength in group 3 was significantly lower than that in groups 1 and 2. The histological findings in group 2 were similar to those in group 1, although an acellular area appeared to be wider in the core portion compared with group 1 at each period. In group 3, the collagen bundles of the tendon were less organised than those of groups 1 and 2. Our findings showed that stress enhancement affects the remodelling of the frozen-thawed patellar tendon and that excessively high stress reduces the mechanical properties of the tendon. This indicates that high stress on the patellar tendon autograft should be avoided during ligament reconstruction


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 159 - 159
1 Jul 2014
Elnikety S Pendegrass C Alexander S Blunn G
Full Access

Summary. Our study shows that a tendon rupture can be successfully augmented with Demineralised Cortical Bone (DCB) giving initial appropriate mechanical strength suitable for in vivo use providing the biological reactions to the graft are favourable. Introduction. Treatment of tendon and ligament injuries remains challenging; the aim is to find a biocompatible substance with mechanical and structural properties that replicate those of normal tendon and ligament. Because of its structural and mechanical properties, we proposed that DCB can be used in repair of tendon and ligament as well as regeneration of the enthesis. DCB is porous, biocompatible and has the potential to be remodelled by the host tissues. 2 studies were designed; in the first we examined the mechanical properties of DCB after gamma irradiation (GI) and freeze drying (FD). In the second we used different techniques for repairing bone-tendon-bone with DCB in order to measure the mechanical performance of the construct. Methods. In the first study we allocated the DCB specimens into 4 groups; group-A non-freeze dried non-gamma irradiated, group-B freeze dried non-gamma irradiated, group-C non-freeze dried gamma irradiated and group-D freeze dried and gamma irradiated. The 4 groups were tested for maximum tensile strength. In the 2nd study, patella - patellar tendon - tibia construct of mature ewes were harvested and the distal 1cm of the patellar tendon was excised, 4 models of repair were tested;. • Model-1, DCB was used to bridge the gap between the tendon and the tibial tuberosity. The DCB strip was stitched to the tendon using one bone anchor. • Model-2, similar to model-1 with the use of 2 bone anchors. • Model-3, similar to model-2, construct was offloaded by Fiberwire continuous thread looped twice through bony tunnels sited in the patella and in the tibial tuberosity. • Model-4, similar to model-3 with 3 hand braided fiberwire threads as offloading loop. All 4 models were tested until failure and force displacement curves used to investigate the structural properties of the reconstruction. Results. The Median of maximum tensile force for group-A was 218N [95%C.I.=147.9–284.7N], group-B was 306N [95%C.I.=154.1–488.6N], group-C was 263N [95%C.I.=227.8–315.6N], group-D was 676N [95%C.I.=127-1094.9N]. Group-D results were statistically higher (p=<0.05) compared to group-A and group-C, while there was no statistical significance compared to group-B. The median failure force for model-1 was 250N, (95%C.I.=235-287), model-2 was 290N (95%C.I.=197-396), model-3 was 767N (95%C.I.=730-812) and for model-4 was 934N (95%C.I.=867-975). There was no statistical significance between model-1 and model-2 (p=0.249), however statistical significance was found between other models (p=<0.006). Discussion. Demineralised Bone is widely used as a bone graft substitute and may be used to augment bone formation in load bearing applications. In this study we focus on the potential use of demineralised bone in ligament and tendon repair. A previous animal study by our group found that the use of demineralised bone can enhance healing of the enthesis. Other published studies suggested the possibility of using DCB as ligament substitute. We examined the effect of gamma radiation as the most common sterilisation technique in medical field and the freeze drying as a possible technique for long term storage on the tensile strength of the DCB


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 3 - 3
1 Jan 2019
Edwards J Ingham E Fisher J Herbert A
Full Access

We have developed a decellularised porcine superflexor tendon (pSFT), which has shown promising regenerative capacity in an ovine model of anterior cruciate ligament (ACL) repair. This study investigated the strain rate dependent and dynamic mechanical properties of native and decellularised pSFTs. Decellularisation was carried out using a previously established procedure, including antibiotic washes, low concentration detergent (0.1% sodium dodecyl sulphate) washes and nuclease treatments. Three different strain rates were employed: 1, 10 & 100%s-1 (n=6 for all groups). Toe-region modulus (E0), linear-region modulus (E1), transition coordinates (εT, σT), tensile strength (UTS) and failure strain were calculated. For DMA, specimens were loaded between 1 & 5MPa with increasing frequency up to 2Hz. Dynamic (E*), storage (E') and loss (E'') moduli, and tan delta were calculated for native and decellularised groups (n=6). Data was analysed by 2-way ANOVA and Tukey post-hoc test (p<0.05). For decellularised tendons, altering the strain rate did not affect any of the static tensile properties. For native pSFTs, the UTS, failure strain and E1 were not affected by changing the strain rate. Increasing the strain rate significantly increased E0 (1% vs 10% and 1% vs 100%) and σT (1% vs 100%) and decreased εT (1% vs 10% and 1% vs 100%) for native pSFT. E*, E' and E'' were all significantly reduced in decellularised specimens compared to native controls across all frequencies investigated. No significant differences were found for tan delta. Evidence of strain rate dependency was witnessed in the native pSFTs by increase of the toe region modulus and displacements of the transition point coordinates. This response was not seen in the tissue following decellularisation. DMA demonstrated a reduction in dynamic, storage and loss moduli. Tan delta (E''/E') remained unchanged, indicating reductions in solid and fluid components are interlinked


Bone & Joint Research
Vol. 6, Issue 4 | Pages 231 - 244
1 Apr 2017
Zhang J Yuan T Zheng N Zhou Y Hogan MV Wang JH

Objectives. After an injury, the biological reattachment of tendon to bone is a challenge because healing takes place between a soft (tendon) and a hard (bone) tissue. Even after healing, the transition zone in the enthesis is not completely regenerated, making it susceptible to re-injury. In this study, we aimed to regenerate Achilles tendon entheses (ATEs) in wounded rats using a combination of kartogenin (KGN) and platelet-rich plasma (PRP). Methods. Wounds created in rat ATEs were given three different treatments: kartogenin platelet-rich plasma (KGN-PRP); PRP; or saline (control), followed by histological and immunochemical analyses, and mechanical testing of the rat ATEs after three months of healing. Results. Histological analysis showed well organised arrangement of collagen fibres and proteoglycan formation in the wounded ATEs in the KGN-PRP group. Furthermore, immunohistochemical analysis revealed fibrocartilage formation in the KGN-PRP-treated ATEs, evidenced by the presence of both collagen I and II in the healed ATE. Larger positively stained collagen III areas were found in both PRP and saline groups than those in the KGN-PRP group. Chondrocyte-related genes, SOX9 and collagen II, and tenocyte-related genes, collagen I and scleraxis (SCX), were also upregulated by KGN-PRP. Moreover, mechanical testing results showed higher ultimate tensile strength in the KGN-PRP group than in the saline control group. In contrast, PRP treatment appeared to have healed the injured ATE but induced no apparent formation of fibrocartilage. The saline-treated group showed poor healing without fibrocartilage tissue formation in the ATEs. Conclusions. Our results show that injection of KGN-PRP induces fibrocartilage formation in the wounded rat ATEs. Hence, KGN-PRP may be a clinically relevant, biological approach to regenerate injured enthesis effectively. Cite this article: J. Zhang, T. Yuan, N. Zheng, Y. Zhou, M. V. Hogan, J. H-C. Wang. The combined use of kartogenin and platelet-rich plasma promotes fibrocartilage formation in the wounded rat Achilles tendon entheses. Bone Joint Res 2017;6:231–244. DOI: 10.1302/2046-3758.64.BJR-2017-0268.R1


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 136 - 136
1 Nov 2018
Traweger A
Full Access

There is a growing socio-economic need (i.e. “ageing society”) for effective and reproducible strategies to repair musculoskeletal tissue. In particular, acute tendon injury and chronic tendinopathies remain clinically challenging and novel treatment modalities are urgently needed. Tendons resemble a connective tissue rich in highly organized collagen fibers, displaying a remarkably high tensile strength. However, partly due to the low number of cells and their more or less avascular nature tendons heal relatively slowly. Ultimately, tendon regeneration encompasses the full restoration of the biological, biochemical and biomechanical properties, which are often impaired by endogenous healing cascades. Usually, a connective scar tissue forms at the injury site and the replaced tissue does not function adequately at high strain levels, increasing the chance of re-rupture. Despite significant advancements in tissue regeneration and engineering strategies, the clinical impact for the regeneration of tendon remains limited. For the development of novel methods to repair tendons we need to pin down the molecular and cellular mechanisms amenable to modulate endogenous (or exogenous) cell behaviour towards functional tissue regeneration. By comparing the gene expression profile of Achilles tendon tissue harvested from young-mature and old mice we demonstrate profound changes in the expression of ECM-related proteins and a previously unknown role of Secreted protein acidic and rich in cysteine (Sparc; also known as BM-40 or osteonectin) in tendons. Sparc levels in tendons are critical for proper collagen fibril maturation and its age-related decrease, together with a change in ECM properties potentially drives adipogenic differentiation of tendon stem and progenitor cells (TDSPCs) and consequently lipid accretion in tendons. Generally, the fate of stem/ progenitor cells is largely determined by stimuli from the stem cell niche. In tendons, we describe a novel cellular barrier, most likely preventing the leakage of blood-borne products into the tendon proper. We propose that this “blood-tendon barrier” is part of the stem cell niche in tendons controlling TDSCP fate, preventing erroneous differentiation. By investigating the developmental programs driving tendon tissue formation and on the other hand the mechanisms contributing to the senescence of tendons, ultimately resulting in decreased quality of tendons in the elderly, novel targets for clinical intervention potentially can be discovered


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 70 - 70
1 Apr 2017
Günzel E Barnouin L Delépine P Le Pape F
Full Access

Background. Meniscal tears are among the most common knee injuries. To preserve as much as possible the joint, partial and total meniscal replacements are necessary. To combine the biocompatibility and mechanical resistance of meniscus allograft with the disponibility of synthetic substitutes, an acellular, viroinactivated and sterile scaffold with well-preserved structure has been developed based on PHOENIX process. Methods. Human menisci were collected from living donors undergoing total knee arthroplasty. They underwent chemical treatments, freeze-drying and gamma irradiation. Decellularisation of menisci and preservation of the matrix structure were explored by histological studies. Meniscal scaffold ultrastructure was analysed by scanning electron microscopy. Biomechanical studies were also conducted. Scaffold viroinactivation was investigated by viral clearance studies. Finally, the allografts were cultured for 4 weeks with Mesenchymal Stem Cells (CSM); cells viability and proliferation were assessed histologically and by confocal microscopy following stainings. Results. Histological data evidenced that the process led to complete decellularisation of the menisci, high porosity within the tissue and to the removal of glycosaminoglycans, present in the center of native menisci. The meniscal surface as well as collagen fibers were preserved as assessed by electron scanning microscopy. Ultimate tensile strengths of native and processed menisci were similar. Viral clearance studies showed that each viral inactivation step induced a viral load reduction compliant with the reduction factor specified in the European guidelines. CSM exhibited great viability and proliferation at the surface of the allograft and partial penetration inside. Conclusions. Scaffold safety is conferred by decellularisation and viroinactivation of the meniscus while preserving structure and mechanical resistance of the tissue, enabling cells to proliferate around and inside the allograft. Freeze-drying and gamma irradiation make it a ready-to-use product, with different sizes for partial and total meniscal replacement


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 44 - 44
1 Apr 2018
Bernstein A Reichert A Weichand P Gadow R Südkamp NP Mayr HO
Full Access

To date there has been no material for endoprosthetics providing excellent resistance to abrasion and corrosion combined with great tensile strength, fracture toughness, and bending strength, as well as adequate biocompatibility. Carbon-fiber-reinforced silicon carbide (C/SiC, C/C-SiC or C/SiSiC) is as a ceramic compound a potentially novel biomaterial offering higher ductility and durability than comparable oxide ceramics. Aim of this investigation was to test the suitability of C/SiC ceramics as a new material for bearing couples in endoprosthetics. One essential quality that any new material must possess is biocompatibility. For this project the in-vitro biocompatibility was investigated by using cuboid like scaffolds made of CMC. To determine whether the material is suited as a lubricant partner in endoprosthetics, we measured its abrasion coefficient and wear tolerance against various antibodies. The C/SiC samples tested were produced via the Liquid Silicon Infiltration (LSI) of pyrolized porous fiber preforms made by warm-flow pressing free-flowing granulates on a hydraulic downstroking press with a heated die of the type HPS-S, 1000 kN. After preparation of the composites, the tribological characteristics are determined. Flexural strength was determined at room temperature according to DIN685-3 with an universal testing machine Z100 and the Young”s -modulus was carried out via resonant frequency-damping analysis RFDA. The samples”surface as well as cell adhesion and cell morphology were assessed via ESEM. The human osteoblast-like cell line MG-63 and human ostoeblast were used for cel culture ecperiments (WST, Live/dead, Cytotoxicity, cell morphology). Based on the raw data the mean value and the standard deviation were calculated. The Mann-Whitney-U-Test was used to evaluate the differences between experiment and control samples. The flexural strength at room temperature is approx. 180 MPa, while the elongation at break is about 0.13%. The Young”s modulus is detected between 120 and 150 GPa. The density lies between 2.5 and 3.0 g/cm. 3. We noted a friction coefficient µ between 0.31. The cell lines exhibited no morphological alterations, and adhered well to the C/SiC samples. Vitality was not impaired by contact with the ceramic composite. Cell growth was observed evenly distributed over a 21-day period. In the future, investigators aiming to apply this composite in endoprosthetics will have to focus on its efficacy in conjunction with sudden, strong demands, and long-term performance in bodily fluids within joint simulators, etc. In conclusion: C/SiC can definitely be considered a new material with genuine potential for use in endoprosthetics


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 15 - 15
1 Oct 2016
Herbert A Edwards J Ingham E Fisher J
Full Access

Acellular porcine super flexor tendon (pSFT) offers a promising solution to replacement of damaged anterior cruciate ligament [1]. It is desirable to package and terminally sterilise the acellular grafts to eliminate any possible harmful pathogens. However, irradiation techniques can damage the collagen ultra-structure and consequently reduce the mechanical properties [2]. The aims of this study were to investigate the effects of irradiation sterilisation of varying dosages on the biomechanical properties of the acellular pSFT. Tendons were decellularised using a previously established protocol [1] and subjected to irradiation sterilisation using either 30 kGy gamma, 55 kGy gamma, 34 kGy E-beam, 15 kGy gamma, 15 kGy E-beam and (15+15) kGy E-beam (fractionated dose). Specimens then underwent stress relaxation and strength testing at 0 and 12 months post sterilisation to determine whether any effect on these properties was progressive. For stress relaxation testing, specimens were analysed using a Maxwell-Wiechert model. For strength testing, the ultimate tensile strength, Young's modulus and failure strain were assessed. Significant differences were found which demonstrated that all irradiation treatments had an effect on the time-independent and time-dependent viscoelastic properties of irradiated tendons compared to per-acetic acid only treated controls. Interestingly, no significant differences were found between the irradiated groups. Similar trends were found for the strength testing properties. No significant differences were found between groups at 0 and 12 months. Tendons retained sufficient biomechanical properties following sterilisation, however it was notable that there were no significant differences between the irradiated groups, as it was believed higher dosages would lead to a greater reduction in the mechanical properties. The changes observed were not altered further after 12 months storage, indicating the acellular pSFT graft has a stable shelf-life