Additive manufacturing has led to numerous innovations in orthopaedic surgery: surgical guides; surface coatings/textures; and custom implants. Most contemporary implants are made from titanium alloy (Ti-6Al-4V). Despite being widely available industrially and clinically, there is little published information on the performance of this 3D printed material for orthopaedic devices with respect to regulatory approval. The aim of this study was to document the mechanical, chemical and biological properties of selective laser sintering (SLS) manufactured specimens following medical device (TOKA®, 3D Metal Printing LTD, UK) submission and review by the UK Medicines and Healthcare Products Regulatory Agency (MHRA). All specimens were additively manufactured in Ti-6Al-4V ELI (Renishaw plc, UK). Mechanical tests were performed according to ISO6892-1, ISO9585 and ISO12107 for tensile (n=10), bending (n=3) and fatigue (n=16) respectively (University of Bath, UK). Appropriate chemical characterisation and biological tests were selected according to recommendations in ISO10993 and conducted by external laboratories (Wickham Labs, UK; Lucideon, UK; Edwards Analytical, UK) in adherence with Good Lab Practise guidelines. A toxicological review was conducted on the findings (Bibra, UK).Abstract
Objectives
Methods
We examined macroscopically and microscopically 55 cadaver rotator-cuff tendons attached to their humeral heads to determine the distance between the edge of the articular cartilage and the tendon insertion of the supraspinatus (the width of the sulcus) and the score of regressive changes at the sulcus. In 33 specimens we measured the
Although autografts represent the gold standard for anterior cruciate ligament (ACL) reconstruction, tissue-engineered ACLs provide a prospect to minimize donor site morbidity and limited graft availability. This given study characterizes the ligamentogenesis in embroidered poly(L-lactide-co-ε-caprolactone) (P(LA-CL)) / polylactic acid (PLA) constructs using a dynamic nude mice xenograft model. (P(LA-CL))/PLA scaffolds remained either untreated (co) or were functionalized by gas fluorination (F), collagen foam cross-linked with hexamethylene diisocyanate (HMDI) (coll), or gas fluorination combined with the foam (F+coll). Cell free constructs or those seeded for 1 week with lapine ACL ligamentocytes were implanted into nude mice for 12 weeks. Following explantation, biomechanical properties, cell vitality and content, histopathology of scaffolds (including organs: liver, kidney, spleen), sulphated glycosaminoglycan (sGAG) contents and biomechanical properties were assessed. Implantation of the scaffolds did not negatively affect mice weight development and organs, indicating biocompatibility. All scaffolds maintained their size and shape for the duration of the implantation. A high cell viability was detected in the scaffolds prior to and following implantation. Coll or F+coll scaffolds seeded with cells yielded superior macroscopic properties when compared to the controls. Mild signs of inflammation (foreign-body giant cells, hyperemia) were limited to scaffolds without collagen. Microscopical score values and sGAG content did not differ significantly. Although remaining stable in vivo, elastic modulus, maximum force,
Decellularised porcine superflexor tendon (pSFT) has been demonstrated to be a suitable scaffold for anterior cruciate ligament reconstruction[1]. While the role of collagen in tendons is well known, the mechanical role of glycosaminoglycans (GAGs) is less clear and may be altered by the decellularisation process. To determine the effects of decellularisation on pSFT GAG content and mechanical function and to investigate the consequences of GAG loss in tensile and compressive loading. pSFTs were decellularised following previous techniques [2]. For GAG removal, native pSFTs were treated with chondroitinase ABC (ChABC; 0.1U/mL, 72h). Cell and GAG removal was validated using histology and quantitative assays. Native, decellularised and ChABC treated groups (n=6) were biomechanically characterised. In tension, specimens underwent stress relaxation and strength testing using previous protocols [1]. Stress relaxation data was fitted to a modified Maxwell-Weichert model to determine time-dependent (E1 & E2) and time-independent moduli (E0). The toe and linear region moduli (Etoe, Elinear), in addition to
Summary Statement. A novel biomimetic polydioxanone tendon patch with woven and electrospun components is biocompatible, recapitulates native tendon architecture and creates a tissue-healing microenvironment directed by a subpopulation of regenerative macrophages. The woven component provides
Abstract. Objectives. Direct ink writing (DIW) has gained considerable attention in production of personalized medical implants. Laponite nanoclay is added in polycaprolactone (PCL) to improve printability and bioactivity for bone implants. The 3D structure of DIW printed PCL/Laponite products was qualitatively evaluated using micro-CT. Methods. PCL/LP composite ink was formulated by dissolving 50% m/v PCL in dichloromethane with Laponite loading of up to 30%. The rheological properties of the inks were determined using Discovery HR-2 rheometer. A custom-made direct ink writer was used to fabricate both porous scaffold with 0°/90° lay-down pattern, and solid dumbbell-shaped specimens (ASTM D638 Type IV) with two printing orientations, 0° and 90° to the loading direction in tensile testing. The 3D structure of specimens was assessed using a micro-CT. Independent t-tests were performed with significance level at p<0.05. Results. The addition of Laponite in PCL ink has significantly enhanced viscosity for shape fidelity and shear-thinning property facilitating extrusion for DIW. Uniform distribution of Laponite was illustrated by micro-CT. For the 32-layer scaffold, interconnectivity of pores is observed at all 3 planes. The variation of height and width of layers is within 6% except the bottom 2 layers which are significantly lower and wider than other layers for mechanical support. For solid specimens, no ditches/interfaces between filaments are observed in 90° orientation while they are distinctive in 0° orientation because deposited filaments contact each other sooner in 90° orientation. 90° specimens also have lower air gap fraction (0.8 vs 5.4 %) and significantly higher Young's modulus (235 vs 195 MPa) and
Abstract. Objectives. Tendon and ligament injury poses an increasingly large burden to society. With surgical repair and grafting susceptible to high failure rates, tissue engineering provides novel avenues for treatment. This systematic review explores in vivo evidence whether mesenchymal stem cell-derived extracellular vesicles (MSC-EVs) can facilitate tendon and ligament repair in animal models. Methods. On May 26th 2021, a systematic search was performed on PubMed, Web of Science, Cochrane Library, Embase, using search terms ‘mesenchymal stem cell’ or ‘multipotent stem cell’ AND ‘extracellular vesicles’ or ‘exosomes’ AND ‘tendon’ or ‘ligament’ or ‘connective tissue’. Risk of bias was assessed using SYstematic Review Center for Laboratory animal Experimentation (SYRCLE) tool. Studies administering EVs isolated from human or animal-derived MSCs into in vivo models of tendon/ligament injury were included. In vitro, ex vivo, in silico studies were excluded, and studies without a control group were excluded. Data on isolation and characterisation of MSCs and EVs, and in vivo findings in animal models were extracted. Results. Out of 383 relevant studies, 11 case-control studies were included for data extraction, including a total of 448 animal subjects (range 10–90). Six studies utilised bone marrow-derived MSCs. All studies characterised their MSCs via flow cytometry, which expressed CD44 and CD90, and isolated EVs via ultracentrifugation (average diameter 125nm). Five studies utilised histological scoring systems, all of which reported a lower score with EV treatment, suggesting improved healing ability. Four studies reported increased anti-inflammatory cytokine expression (IL-10, TGF-β1); three studies reported decreased endogenous M1/M2 macrophage ratio with EV treatment. Eight studies reported increased maximum stiffness, breaking load,
Dura mater is a thick membrane that is the outermost of the three layers of the meninges that surround the brain and spinal cord. Appropriate dural healing is crucial to prevent cerebrospinal fluid leaks but the entire process has been barely understood so far. Understanding of dural healing and tissue neoformation over the dural grafts, which are usually used for duraplasty, is still partial. Therefore, implantation of decellular dura mater (DM) to recipient from different donor and vitalization with recipient”s mesenchymal stem cells for the treatment of tissue on transplantation process is significant approach. This approach prevents immunological reactions and provides long-term stabilization. According to this study, it is believed that this approach will provide DM healing and become crucial in DM transplantation. The aim of this study was to develop a new construct by tissue engineering of the human DM based on a decellular allograft. Thus human DM collected from forensic medicine and decellularized using the detergent sodium dodecyl sulfate (SDS) in the multiple process of physical, enzimatic and chemical steps. Decellularization were exposing the tissue to freeze-thaw cycles, incubation in hypotonic tris-HCl buffer, 0.1% (w/v) SDS in hypotonic buffer and hypertonic buffer followed by disinfection using 0.1% (v/v) peracetic acid and final washing in phosphate-buffered saline. As a result of all these processes, cellular components of DM were removed by preserving the extracellular matrix without any significant loss in mechanical properties. Based on the histological analysis of the decellularized DM revealed the absence of visible whole cells. Collagen and glycosaminoglycan (GAG) contents of decellular DM evaluated histological staining by Masson Trichrome and Alcian blue respectively. Also biochemical tests were carried out by spectrophotometry (Quickzym Biosciences, The Netherlands) and total GAG content were analyzed by 1.9 dimethylmethylene blue assay. The histoarchitecture was unchanged, and there were no significant changes of total collagen and GAG content. Biomechanical properties were determined by tensile tests, which has confirmed the retention of biomechanical properties following decellularization. The mean
Objectives. All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors. Materials and Methods. A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05. Results. Overall, mean maximum
Introduction. Primary cilia are organelles found singularly on almost every cell in the body, including tenocytes. Tendon is a hierarchical, composite structure, and previous work from our group has suggested that the cell populations in the inter-fascicular matrix (IFM) may be different from those within the fascicle matrix (FM). This study investigated how stress deprivation influenced the primary cilia of both cell types, and the mechanics of the IFM and the FM. Materials and Methods. Rat tail tendons were dissected and then either tested immediately (fresh), or maintained in media for 1 week, either stress deprived or at 4% static strain. Fascicles and IFM were then either, fixed and imaged to determine cilia length (n = 80–160 cilia per group from across 3 rats), or mechanically tested to determine the static and viscoelastic properties of both the fascicles and the IFM (n = 6–8 per group). Results. Cilia length in the IFM and FM of fresh samples were not significantly different. After 1 week of stress deprivation, the cilia had significantly increased in length in both the IFM and FM, however the increase in length in the IFM was significantly greater than that in the FM. Cilia in tissue maintained at 4% static strain were significantly shorter than those in stress deprived tissue, however they remained longer than those in fresh tissue. The
We investigated the effect of mitomycin-C on the reduction of the formation of peritendinous fibrous adhesions after tendon repair. In 20 Wistar albino rats the tendo Achillis was cut and repaired using a modified Kessler technique. The rats were divided into two equal groups. In group 1, an injection of mitomycin-C was placed between the tendon and skin of the right leg. In group 2, an identical volume of sterile normal saline was injected on the left side in a similar fashion. All the rats received mitomycin-C or saline for four weeks starting from the day of operation. The animals were killed after 30 days. The formation of peritendinous fibrous tissue, the inflammatory reaction and tendon healing were evaluated. The
We report the effects of local administration of osteogenic protein-1 on the biomechanical properties of the overstretched anterior cruciate ligament in an animal model. An injury in the anterior cruciate ligament was created in 45 rabbits. They were divided into three equal groups. In group 1, no treatment was applied, in group II, phosphate-buffered saline was applied around the injured ligament, and in group III, 12.5 μg of osteogenic protein-1 mixed with phosphate-buffered saline was applied around the injured ligament. A control group of 15 rabbits was assembled from randomly-selected injured knees from among the first three groups. Each rabbit was killed at 12 weeks. The maximum load and stiffness of the anterior cruciate ligament was found to be significantly greater in group III than either group 1 (p = 0.002, p = 0.014) or group II (p = 0.032, p = 0.025). The
We performed a biomechanical and histological study to clarify the effect of stress enhancement on the in situ frozen-thawed patellar tendon of the rabbit as a tendon autograft model. We used 48 Japanese White rabbits divided into three groups. In group 1, the patellar tendon underwent in situ freeze-thaw treatment with liquid nitrogen to kill intrinsic fibroblasts. In group 2, after similar treatment, the medial and lateral portions were resected so that the cross-sectional area was reduced by a third. In group 3, after treatment, the cross-sectional area was reduced by a half. In groups 2 and 3, the stress in the tendon was calculated theoretically to be 150% and 200% of the physiological stress during locomotion. Eight rabbits in each group were killed at three and six weeks, respectively. At three weeks, the mean values for the
Summary. Our study shows that a tendon rupture can be successfully augmented with Demineralised Cortical Bone (DCB) giving initial appropriate mechanical strength suitable for in vivo use providing the biological reactions to the graft are favourable. Introduction. Treatment of tendon and ligament injuries remains challenging; the aim is to find a biocompatible substance with mechanical and structural properties that replicate those of normal tendon and ligament. Because of its structural and mechanical properties, we proposed that DCB can be used in repair of tendon and ligament as well as regeneration of the enthesis. DCB is porous, biocompatible and has the potential to be remodelled by the host tissues. 2 studies were designed; in the first we examined the mechanical properties of DCB after gamma irradiation (GI) and freeze drying (FD). In the second we used different techniques for repairing bone-tendon-bone with DCB in order to measure the mechanical performance of the construct. Methods. In the first study we allocated the DCB specimens into 4 groups; group-A non-freeze dried non-gamma irradiated, group-B freeze dried non-gamma irradiated, group-C non-freeze dried gamma irradiated and group-D freeze dried and gamma irradiated. The 4 groups were tested for maximum
We have developed a decellularised porcine superflexor tendon (pSFT), which has shown promising regenerative capacity in an ovine model of anterior cruciate ligament (ACL) repair. This study investigated the strain rate dependent and dynamic mechanical properties of native and decellularised pSFTs. Decellularisation was carried out using a previously established procedure, including antibiotic washes, low concentration detergent (0.1% sodium dodecyl sulphate) washes and nuclease treatments. Three different strain rates were employed: 1, 10 & 100%s-1 (n=6 for all groups). Toe-region modulus (E0), linear-region modulus (E1), transition coordinates (εT, σT),
Objectives. After an injury, the biological reattachment of tendon to bone is a challenge because healing takes place between a soft (tendon) and a hard (bone) tissue. Even after healing, the transition zone in the enthesis is not completely regenerated, making it susceptible to re-injury. In this study, we aimed to regenerate Achilles tendon entheses (ATEs) in wounded rats using a combination of kartogenin (KGN) and platelet-rich plasma (PRP). Methods. Wounds created in rat ATEs were given three different treatments: kartogenin platelet-rich plasma (KGN-PRP); PRP; or saline (control), followed by histological and immunochemical analyses, and mechanical testing of the rat ATEs after three months of healing. Results. Histological analysis showed well organised arrangement of collagen fibres and proteoglycan formation in the wounded ATEs in the KGN-PRP group. Furthermore, immunohistochemical analysis revealed fibrocartilage formation in the KGN-PRP-treated ATEs, evidenced by the presence of both collagen I and II in the healed ATE. Larger positively stained collagen III areas were found in both PRP and saline groups than those in the KGN-PRP group. Chondrocyte-related genes, SOX9 and collagen II, and tenocyte-related genes, collagen I and scleraxis (SCX), were also upregulated by KGN-PRP. Moreover, mechanical testing results showed higher ultimate
There is a growing socio-economic need (i.e. “ageing society”) for effective and reproducible strategies to repair musculoskeletal tissue. In particular, acute tendon injury and chronic tendinopathies remain clinically challenging and novel treatment modalities are urgently needed. Tendons resemble a connective tissue rich in highly organized collagen fibers, displaying a remarkably high
Background. Meniscal tears are among the most common knee injuries. To preserve as much as possible the joint, partial and total meniscal replacements are necessary. To combine the biocompatibility and mechanical resistance of meniscus allograft with the disponibility of synthetic substitutes, an acellular, viroinactivated and sterile scaffold with well-preserved structure has been developed based on PHOENIX process. Methods. Human menisci were collected from living donors undergoing total knee arthroplasty. They underwent chemical treatments, freeze-drying and gamma irradiation. Decellularisation of menisci and preservation of the matrix structure were explored by histological studies. Meniscal scaffold ultrastructure was analysed by scanning electron microscopy. Biomechanical studies were also conducted. Scaffold viroinactivation was investigated by viral clearance studies. Finally, the allografts were cultured for 4 weeks with Mesenchymal Stem Cells (CSM); cells viability and proliferation were assessed histologically and by confocal microscopy following stainings. Results. Histological data evidenced that the process led to complete decellularisation of the menisci, high porosity within the tissue and to the removal of glycosaminoglycans, present in the center of native menisci. The meniscal surface as well as collagen fibers were preserved as assessed by electron scanning microscopy. Ultimate
To date there has been no material for endoprosthetics providing excellent resistance to abrasion and corrosion combined with great
Acellular porcine super flexor tendon (pSFT) offers a promising solution to replacement of damaged anterior cruciate ligament [1]. It is desirable to package and terminally sterilise the acellular grafts to eliminate any possible harmful pathogens. However, irradiation techniques can damage the collagen ultra-structure and consequently reduce the mechanical properties [2]. The aims of this study were to investigate the effects of irradiation sterilisation of varying dosages on the biomechanical properties of the acellular pSFT. Tendons were decellularised using a previously established protocol [1] and subjected to irradiation sterilisation using either 30 kGy gamma, 55 kGy gamma, 34 kGy E-beam, 15 kGy gamma, 15 kGy E-beam and (15+15) kGy E-beam (fractionated dose). Specimens then underwent stress relaxation and strength testing at 0 and 12 months post sterilisation to determine whether any effect on these properties was progressive. For stress relaxation testing, specimens were analysed using a Maxwell-Wiechert model. For strength testing, the ultimate