Advertisement for orthosearch.org.uk
Results 1 - 20 of 93
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1081 - 1086
1 Sep 2019
Murphy WS Harris S Pahalyants V Zaki MM Lin B Cheng T Talmo C Murphy SB

Aims. The practice of alternating operating theatres has long been used to reduce surgeon idle time between cases. However, concerns have been raised as to the safety of this practice. We assessed the payments and outcomes of total knee arthroplasty (TKA) performed during overlapping and nonoverlapping days, also comparing the total number of the surgeon’s cases and the total time spent in the operating theatre per day. Materials and Methods. A retrospective analysis was performed on the Centers for Medicare & Medicaid Services (CMS) Limited Data Set (LDS) on all primary elective TKAs performed at the New England Baptist Hospital between January 2013 and June 2016. Using theatre records, episodes were categorized into days where a surgeon performed overlapping and nonoverlapping lists. Clinical outcomes, economic outcomes, and demographic factors were calculated. A regression model controlling for the patient-specific factors was used to compare groups. Total orthopaedic cases and aggregate time spent operating (time between skin incision and closure) were also compared. Results. A total of 3633 TKAs were performed (1782 on nonoverlapping days; 1851 on overlapping days). There were no differences between the two groups for length of inpatient stay, payments, mortality, emergency room visits, or readmission during the 90-day postoperative period. The overlapping group had 0.74 fewer skilled nursing days (95% confidence interval (CI) -0.26 to -1.22; p < 0.01), and 0.66 more home health visits (95% CI 0.14 to 1.18; p = 0.01) than the nonoverlapping group. On overlapping days, surgeons performed more cases per day (5.01 vs 3.76; p < 0.001) and spent more time operating (484.55 minutes vs 357.17 minutes; p < 0.001) than on nonoverlapping days. Conclusion. The study shows that the practice of alternating operating theatres for TKA has no adverse effect on the clinical outcome or economic utilization variables measured. Furthermore, there is opportunity to increase productivity with alternating theatres as surgeons with overlapping cases perform more cases and spend more time operating per day. Cite this article: Bone Joint J 2019;101-B:1081–1086


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 2 - 2
1 Jul 2012
Jones MA Newell C Howard PW
Full Access

Purpose. To establish the reliability of reporting and recording revision hip and knee arthroplasties by comparing data in the National Joint Registry (NJR), Hospital Episode Statistics (HES) and our local theatre records. Methods. The paper theatre registers for all orthopaedic theatres in the Royal Derby Hospitals NHS Trust were examined for details of revision hip and knee replacements carried out in 2007 and 2008. This was then cross-checked and merged with the local electronic theatre data to obtain a definitive local record of all revision hip and knee arthroplasties. Data for the same period was requested from the NJR and HES and these data were checked against our definitive local record for discrepancies. The HES codes used were the same codes used to compile the recent NJR annual reports. Results. The theatre registers and ORMIS identified 271 revision hip and knee arthroplasties in the study period. The NJR had corresponding data for 176 (65%) of these, and HES had 250 (92%). 10 cases (4%) were not recorded by either NJR or HES: 8 secondary resurfacings of patellae and 2 posterior lip augmentations in hips. Of those operations “missed” by HES, most had been assigned a correct “W” code, but had a “Y” or “Z” OPCS code not used in the NJR annual reports. Conclusion. When HES and the NJR data are combined, they are an accurate representation of real practice. More robust methods of reporting revision arthroplasty to the NJR are required. The OPCS codes used to indicate a revision need to be reviewed


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 158 - 165
1 Feb 2024
Nasser AAHH Sidhu M Prakash R Mahmood A

Aims. Periprosthetic fractures (PPFs) around the knee are challenging injuries. This study aims to describe the characteristics of knee PPFs and the impact of patient demographics, fracture types, and management modalities on in-hospital mortality. Methods. Using a multicentre study design, independent of registry data, we included adult patients sustaining a PPF around a knee arthroplasty between 1 January 2010 and 31 December 2019. Univariate, then multivariable, logistic regression analyses were performed to study the impact of patient, fracture, and treatment on mortality. Results. Out of a total of 1,667 patients in the PPF study database, 420 patients were included. The in-hospital mortality rate was 6.4%. Multivariable analyses suggested that American Society of Anesthesiologists (ASA) grade, history of peripheral vascular disease (PVD), history of rheumatic disease, fracture around a loose implant, and cerebrovascular accident (CVA) during hospital stay were each independently associated with mortality. Each point increase in ASA grade independently correlated with a four-fold greater mortality risk (odds ratio (OR) 4.1 (95% confidence interval (CI) 1.19 to 14.06); p = 0.026). Patients with PVD have a nine-fold increase in mortality risk (OR 9.1 (95% CI 1.25 to 66.47); p = 0.030) and patients with rheumatic disease have a 6.8-fold increase in mortality risk (OR 6.8 (95% CI 1.32 to 34.68); p = 0.022). Patients with a fracture around a loose implant (Unified Classification System (UCS) B2) have a 20-fold increase in mortality, compared to UCS A1 (OR 20.9 (95% CI 1.61 to 271.38); p = 0.020). Mode of management was not a significant predictor of mortality. Patients managed with revision arthroplasty had a significantly longer length of stay (median 16 days; p = 0.029) and higher rates of return to theatre, compared to patients treated nonoperatively or with fixation. Conclusion. The mortality rate in PPFs around the knee is similar to that for native distal femur and neck of femur fragility fractures. Patients with certain modifiable risk factors should be optimized. A national PPF database and standardized management guidelines are currently required to understand these complex injuries and to improve patient outcomes. Cite this article: Bone Joint J 2024;106-B(2):158–165


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 8 - 8
1 Jul 2022
Dalal S Guro R Kotwal R Chandratreya A
Full Access

Abstract. Methodology. Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. 76 cases (mean age of 33.2 years) who had primary ACL reconstruction with BTB or quadriceps tendon with bone block, were divided into 2 matched groups (age, sex and type of graft) of 38 each based on the method of femoral fixation used (interference screw or adjustable cortical suspension). Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Complications and return to theatre were noted. Paired two-tailed student t-tests and Chi-square tests were employed for statistical analysis. Results. At a mean follow-up of 82 months, peri-operative mean EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.05), but no significant difference between the two groups (p>0.05). Mean graft length and diameter was 77mm and 9.3 respectively. Mean interval from injury to surgery was 10.5 months. 18(23.7%) patients had associated meniscal tear with 73.3 % undergoing repair. 10 cases (13.2 %) returned to theatre including, MUA for arthrofibrosis (n=2) and intra-substance graft failure (n=2). 3 cases had to be converted to interference screw fixation due to the tightrope cutting through from the femoral bone block as a result of a technical pitfall. Conclusion. Primary ACL reconstruction using adjustable cortical suspension on femoral side for BTB or quadriceps bone-block tendon graft is a safe technique with added advantages of 360 degree bone ingrowth and no screw in the femoral tunnel


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 58 - 58
7 Aug 2023
Saghir R Watson K Martin A Cohen A Newman J Rajput V
Full Access

Abstract. Introduction. Knee arthroscopy can be used for ligamentous repair, reconstruction and to reduce burden of infection. Understanding and feeling confident with knee arthroscopy is therefore a highly important skillset for the orthopaedic surgeon. However, with limited training or experience, furthered by reduced practical education due to COVID-19, this skill can be under-developed amongst trainee surgeons. Methods. At a single institution, ten junior doctors (FY1 to CT2), were recruited as a part of a five, two-hour session, training programme utilising the Simbionix® ARTHRO Mentor knee arthroscopy simulator, supplemented alongside educational guidance with a consultant orthopaedic knee surgeon. All students had minimal to no levels of prior arthroscopic experience. Exercises completed included maintaining steadiness, image centering and orientation, probe triangulation, arthroscopic knee examination, removal of loose bodies, and meniscectomy. Pre and post-experience questionnaires and quantitative repeat analysis on simulation exercises were undertaken to identify levels of improvement. Results. Comparing pre and post-experience questionnaires significant improvements in levels of confidence were noted in the following domains: naming arthroscopic instruments, port positioning and insertion, recognising normal anatomy arthroscopically, holding and using arthroscopic instruments and assisting in a live theatre setting (p<0.05). Significant improvements were noted in time taken to complete, distance covered in metres and roughness of instruments used on the simulated exercises on repeat performance (p<0.05). Conclusion. With only five sessions under senior guidance, using a simulator such as the ARTHRO Mentor, significant improvements in both levels of confidence and skill can be developed even among individuals with no prior experience


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 79 - 79
7 Aug 2023
Houston J Everett S Choudhary A Middleton S Mandalia V
Full Access

Abstract. Introduction. Symptomatic osteochondritis dissecans (OCD) and traumatic osteochondral fractures (OCF) are treated with fixation with either metal or bioabsorbable device. We performed a comparative review of patients with OCD and traumatic OCF stabilised with Bio-Compression screws which are headless absorbable compression screws. Our aim was to determine whether there was a difference in outcomes between presentations. Methods. Retrospective single-centre cohort study of all patients with OCD and OCF treated with Bio-Compression screw between July 2017 and September 2022. All patients followed up until discharge with satisfactory clinical outcome. Primary outcome was return to theatre for ongoing pain or mechanical symptoms. Secondary outcome was evidence of fixation failure on follow-up MRI scan. Results. 20 patients included; 8 OCF and 12 OCD. Average age 21 (OCF), 24 (OCD). The most common location was patella (58%) in OCF or the medial femoral condyle (75%) in OCD. Traumatic defects were smaller (2.6cm2 vs 3.3cm2) although this was not statistically significant (p=0.28). In the OCF group one patient went on to have further surgery. There were no re-operations in the OCD group. Both groups had good outcomes and similar times to discharge. There was no evidence of fixation failure of Bio-Compression screws on MRI scans. Conclusions. Within the limits of this relatively small cohort there is no significant difference between outcomes for OCD or traumatic OCF fixation with Bio-Compression screws. Both groups demonstrate good outcomes irrespective of the location or the aetiology of the fragment


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 36 - 36
7 Aug 2023
Matthews S Acton D Tucker A Graham J
Full Access

Abstract. Introduction. The Syn-VAR RCT is the first of its kind comparing hamstrings autograft v synthetic neoligament for MPFL reconstruction. Our aim is to evaluate short and long term patient related outcomes measures (PROMs) following synthetic / autologous MPFL reconstruction in a heterogenous cohort of patients with recurrent patellar instability. Method. 20 patients meeting inclusion criteria were recruited and randomised. Standardised surgery was performed by a single surgeon in Altnagelvin Hospital with data collected over 3 years from 2016. Kujala score was the primary outcome measure with data captured preoperatively and 12 weeks/2 years postoperatively. Secondary outcomes included four other validated scores and complications including Norwich Patellar Instability, Lysholm, IKDC and Banff. Results. 20 patients with an average age of 19 included 9 females and 11 males. At 12 weeks and 2 years Kujala improvement in the hamstring group was 18 and 32 (both p<0.05) compared to the synthetic group where the increase was 2 and 20 (p<0.05). All secondary score improvements at 2 years were significant (p<0.05) with no difference in any score at all time intervals when comparing both groups (p<0.05). Discussion. Our RCT validates the non-inferiority of synthetic MPFL reconstruction as a treatment for restoring patellar stability in a small heterogenous group with positive long term data and minimal morbidity. With no hamstring harvesting offering a reduction in theatre time with this offers a safe, efficient and viable alternative with reduced morbidity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 56 - 56
7 Aug 2023
Nicholls K Wilcocks K Shean K Anderson J Matthews A Vachtsevanos L
Full Access

Abstract. Introduction. Compared to the standard Tomofix plate, the anatomical Tomofix medial high tibial (MHT) plate has been shown to improve anatomical fit and post correction tibial contour, following high tibial osteotomy (HTO). Clinical data on surgical complications, osteotomy union rates and survivorship with the anatomical Tomofix MHT plate however remain limited. This study reports mid-term results of HTO surgery, using the anatomical Tomofix MHT plate. Methods. All patients undergoing HTO surgery using the anatomical Tomofix MHT plate between 2017 and 2022 were included in the study. Data on complications, osteotomy union rates and survivorship were collected prospectively and retrospectively analysed. Results. 78 HTO procedures were performed using the anatomical Tomofix plate in 68 patients. Follow-up ranged between 6 weeks and 5 years. Postoperative complications included 5 hinge fractures that united without further intervention, 1 deep vein thrombus and 1 subclinical pulmonary embolism. There were no wound problems and no returns to theatre, other than for planned removal of metalwork at 1 year. All osteotomies united with no loss of correction. Only 1 HTO was successfully revised to a partial medial knee replacement 2.5 years following osteotomy. The 5-year survivorship was 98.7%. Conclusion. The anatomical Tomofix MHT plate achieves excellent biomechanical stability and union rates in HTO surgery, with minimal complications and excellent mid-term HTO survivorship


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 58 - 58
1 Jul 2022
Joshi A Gupte C Bhattacharyya R Ahmad K Porteous A Murray J Murray J
Full Access

Abstract. Introduction. In recent years, CTA has been an effective training adjunct for orthopaedic procedures. ACLR is a complex procedure with a steep learning curve. Aim. To design a multimedia CTA learning tool for ACLR using a modified Delphi methodology. Methodology:. CTA generation: A modified Delphi method was used to generate a list of Technical Steps (TS), Decision Points (DP) and errors/solutions for an ACLR that was approved by an expert consensus amongst four, fellowship-trained knee surgeons. A technical workflow was designed to generate the audio-visual tool. Pilot study: 30 novice trainees were granted access to the CTA tool and then performed the ACLR in a cadaveric simulation workshop. A 5-point Likert scale aimed to qualitatively assess if the CTA was useful to their learning. Results:. CTA generation: 156 TS and 79 DP were included for an ACLR procedure which was divided into 7 phases. The audio-visual component was combined with the written tool to design the final CTA tool. Pilot study: 95% of trainees suggested the CTA tool would be useful before carrying out an ACLR in the operating theatre. They agreed it made their ACLR learning more effective. Conclusion:. We have designed a novel and easily accessible CTA tool to standardise teaching of ACLR surgery. Novice surgeons verify the value of the CTA as an adjunct to their apprenticeship training. Future work: A Randomised Controlled Trial (RCT) is currently being planned to evaluate whether there are any objective benefits of this CTA to train surgeons performing an ACLR


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 92 - 92
1 Jul 2022
Jones CS Johansen A Inman D Eardley W Toms A Evans J
Full Access

Abstract. Introduction. In 2020, the National Hip Fracture Database (NHFD) was extended to capture data from patients with periprosthetic femoral fractures (PPFF) with plans to include these patients in Best Practice Tarif. We aimed to describe the epidemiology of PPFF in England and Wales, with a particular focus on fractures occurring around the femoral component of knee prostheses. Methodology. This population-based observational cohort study utilised open-access data available from the NHFD. Patients aged over 60, admitted to an acute hospital in England or Wales with a PPFF, within the period 1st January 2020 to 31st December 2020 were included. The primary outcome was the incidence of PPFF in England and Wales. The secondary outcome was the treatment received. Results. We identified 2606 patients with PPFF from 135 hospitals. Of these, a total of 578 fractures occurred around the femoral component of a knee implant. These were classified as Vancouver A (epicondylar, n=77), B (involving implant/cement, n=166) and C (proximal to implant/cement, n=335). Internal fixation was the most employed treatment, used in 352 cases. Revision arthroplasty was performed in 80 cases, and 100 were managed non-operatively. Only 28% of operated PPFF went to theatre within 36 hours but nearly 90% had orthogeriatrician review within 72 hours. Conclusion. Eighty six percent of patients with PPFF were treated with non-revision surgery and would not be recorded in the National Joint Registry. In response, we support calls for the prioritisation of further research into the prevention and management of PPFF around the knee


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 95 - 95
1 Jul 2022
Bailey J Gaukroger A Manyar H Malik-Tabassum K Fawcett W Gill K
Full Access

Abstract. Introduction. Spinal local anaesthesia and opioids have long been used as peri-operative analgesia for patients undergoing arthroplasty procedures. However, intrathecal opioids are associated with numerous complications. ERAS. ®. society guidelines for elective knee replacement (2019) strongly discourage the use of spinal opioids. This study aims to report the impact of low-dose spinal and local infiltrative analgesia on patients undergoing elective knee replacement. Methodology. Retrospective cohort study of patients undergoing knee replacement under the ERAS protocol over 2 years, at a district general hospital under the care of a single surgeon. Results. A total of 80 knee replacements were included in the study (M38:F42, mean age=72.7, mean BMI=31, ASA: 1=8, 2=54, 3=18). 91% received neuroaxial anaesthesia, 89% without intrathecal opioids. Local infiltrative analgesia was used in 99% of patients. The mean length of stay was significantly shorter (2 days), when compared to patients undergoing elective knee replacements without adherence to ERAS. ®. guidance (3.8 days), P<0.001. The average maximum pain score in PACU was 0.8 (0=no pain, 10=maximum pain). All patients were mobilised within 24 hours of surgery. No patients were readmitted within 30 days. 2 patients returned to theatre (retained surgical clip and MUA for stiffness). Conclusions. The implementation of ERAS. ®. guidelines has demonstrated significantly reduced admission days following elective knee arthroplasty. Combined with low complication rates, the reduction in admission days may result in increased hospital bed availability. This has the potential to positively impact elective arthroplasty waiting lists. Further research is underway to evaluate patient-reported outcome measures in this group


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 49 - 49
1 Jul 2022
Hickland P Cassidy R Diamond O Napier R
Full Access

Abstract. Introduction. Cementless total knee arthroplasty (TKA) offers a number of conceptual benefits including osteointegration, bone preservation and reduced aseptic loosening from third body wear. Evidence of equivalence to cemented fixation exists, but the cam-post interaction of posterior-stabilised (PS)-TKA on implant osteointegration remains uncertain. This study aims to assess the survivorship of a single prosthesis PS-TKA. Methodology. All patients undergoing a PS-TKA using the Triathlon Total Knee System (Stryker Orthopaedics, USA) between 01/01/2010 and 08/04/2019, with exposure to at least 2 years’ risk of revision were identified from the hospital database. Results. 1001 TKAs were identified; 734 cementless and 267 cemented. The cementless group more frequently were male, younger, of higher BMI; and had larger components used (p<0.01). Mean exposure to risk of revision was longer in the cementless group (69.5 vs 57 months, p<0.05). Return to theatre rates were similar (4.6% vs 4.8% p = 0.88), a greater proportion in the cementless group underwent revision (2.9% vs 1.1% p=0.11). Multivariate analysis was only possible for reoperations, increased with cemented fixation (OR 2.34 CI 1.01-5.43) and decreased with age (OR 0.96 CI 0.92-1.00). Conclusion. Both cementless and cemented Triathlon PS-TKA demonstrate excellent survivorship, with revision rates of 2.9% and 1.1% at a mean of 5.25 years. This difference was not statistically significant, and variations in baseline characteristics may have influenced it. Further study is planned to assess radiographs of these patients for evidence of osteointegration, and we advocate further study with greater patient numbers


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 830 - 839
1 May 2021
Ahmed I Chawla A Underwood M Price AJ Metcalfe A Hutchinson CE Warwick J Seers K Parsons H Wall PDH

Aims. Many surgeons choose to perform total knee arthroplasty (TKA) surgery with the aid of a tourniquet. A tourniquet is a device that fits around the leg and restricts blood flow to the limb. There is a need to understand whether tourniquets are safe, and if they benefit, or harm, patients. The aim of this study was to determine the benefits and harms of tourniquet use in TKA surgery. Methods. We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled trials, and trial registries up to 26 March 2020. We included randomized controlled trials (RCTs), comparing TKA with a tourniquet versus without a tourniquet. Outcomes included: pain, function, serious adverse events (SAEs), blood loss, implant stability, duration of surgery, and length of hospital stay. Results. We included 41 RCTs with 2,819 participants. SAEs were significantly more common in the tourniquet group (53/901 vs 26/898, tourniquet vs no tourniquet respectively) (risk ratio 1.73 (95% confidence interval (CI) 1.10 to 2.73). The mean pain score on the first postoperative day was 1.25 points higher (95% CI 0.32 to 2.19) in the tourniquet group. Overall blood loss did not differ between groups (mean difference 8.61 ml; 95% CI -83.76 to 100.97). The mean length of hospital stay was 0.34 days longer in the group that had surgery with a tourniquet (95% CI 0.03 to 0.64) and the mean duration of surgery was 3.7 minutes shorter (95% CI -5.53 to -1.87). Conclusion. TKA with a tourniquet is associated with an increased risk of SAEs, pain, and a marginally longer hospital stay. The only finding in favour of tourniquet use was a shorter time in theatre. The results make it difficult to justify the routine use of a tourniquet in TKA surgery. Cite this article: Bone Joint J 2021;103-B(5):830–839


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 61 - 63
1 Jul 2019
Lawrie CM Schwabe M Pierce A Nunley RM Barrack RL

Aims. The aim of this study was to compare the actual cost of a cemented and cementless total knee arthroplasty (TKA) procedure. Materials and Methods. The cost of operative time, implants, cement, and cementing accessories were included in the overall cost of the TKA procedure. Operative time was determined from a previously published study comparing cemented and cementless implants of the same design. The cost of operative time, implants, cement, and cementing accessories was determined from market and institutional data. Results. Mean operative time for cemented TKA was 11.6 minutes longer for cemented TKA than cementless TKA (93.7 minutes (. sd. 16.7) vs 82.1 minutes (. sd. 16.6); p = 0.001). Using a conservative published standard of $36 per minute for operating theatre time cost, the total time cost was $418 higher for cementing TKA. The cost of cement and accessories ranged from $170 to $625. Overall, the calculated cost of cemented TKA is $588 to $1043, depending on technique. The general increased charge for cementless TKA implants over cemented TKA implants was $366. Conclusion. The overall procedural cost of implanting a cementless TKA is less than implanting a cemented TKA. Cost alone should not be a barrier to using cementless TKA. Cite this article: Bone Joint J 2019;101-B(7 Supple C):61–63


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 675 - 681
1 Jun 2019
Gabor JA Padilla JA Feng JE Anoushiravani AA Slover J Schwarzkopf R

Aims. Revision total knee arthroplasty (rTKA) accounts for approximately 5% to 10% of all TKAs. Although the complexity of these procedures is well recognized, few investigators have evaluated the cost and value-added with the implementation of a dedicated revision arthroplasty service. The aim of the present study is to compare and contrast surgeon productivity in several differing models of activity. Materials and Methods. All patients that underwent primary or revision TKA from January 2016 to June 2018 were included as the primary source of data. All rTKA patients were categorized by the number of components revised (e.g. liner exchange, two or more components). Three models were used to assess the potential surgical productivity of a dedicated rTKA service : 1) work relative value unit (RVU) versus mean surgical time; 2) primary TKA with a single operating theatre (OT) versus rTKA with a single OT; and 3) primary TKA with two OTs versus rTKA with a single OT. Results. In total, 4570 procedures were performed: 4128 primary TKAs, 51 TKA liner exchanges, and 391 full rTKAs. Surgical time was significantly different between the primary TKA, liner exchange, and rTKA cohorts (100.6, 97.1, and 141.7 minutes, respectively; p < 0.001). Primary TKA yielded a mean of 7.1% more RVU/min per procedure than rTKA. Our one-OT model demonstrated that primary TKA (n = 4) had a 1.9% RVU/day advantage over rTKA (n = 3). If two OTs are used for primary TKA (n = 6), the outcome strongly favours primary TKA by an added 34.6% RVUs/day. Conclusion. Our results suggest that a dedicated rTKA service would lead to lower surgeon remuneration based on the current RVU paradigm. Revision arthroplasty specialists may need additional or alternative incentives to promote the development of a dedicated revision service. Through such an approach, healthcare organizations could enhance the quality of care provided, but surgeon productivity measures would need to be adjusted to reflect the burden of these cases. Cite this article: Bone Joint J 2019;101-B:675–681


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 73 - 73
1 Jul 2012
Palmer A Dimbylow D Giritharan S Deo S
Full Access

Orthopaedic practice is increasingly guided by conclusions drawn from analysis of Joint Registry Data. Analysis of the England and Wales National Joint Registry (NJR) led Sibanda et al to conclude that UKR should be reserved for more elderly patients due to higher revision rates in younger patients. To determine our UKR revision rates at the Great Western Hospital we requested knee arthroplasty data from the NJR, Hospital Episode Statistics (HES) data submitted by our centre to the Primary Care Trust, and interrogated our internal theatre implant database. This revealed significant discrepancies between different data sources. We collected data from each source for 2005, 2006, and 2007. Operations were classified as TKR, UKR, Other or Unspecified. Results are illustrated in the attached table:. Key findings:. Our theatre implant database appears most accurate and includes a greater number of joint replacement operations than NJR or HES data and fewer ‘unspecified’ procedures. On average 15% NJR, 0% HES and 0.3% theatre data procedures were ‘unspecified’. NJR data comprises an average 17 fewer, and HES data an average 36 fewer procedures each year compared with our theatre data. Up to 80% UKRs performed are recorded as TKR in HES data. In summary there is significant inaccuracy in our NJR data which may affect the validity of conclusions drawn from NJR data analysis. HES data is even less accurate with implications for hospital funding. We strongly advise other centres to continue to maintain accurate implant data and to perform a similar audit to calculate error rates for NJR and HES data. Further analysis is required to identify at which stage of data collection inaccuracies occur so that solutions can be devised. We are currently analysing data from 2008 and 2009


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 62 - 62
1 Mar 2012
Doyle T Dargan D Connolly C Nicholas R Corry I McClelland C
Full Access

Purpose. To study the initial presentation and subsequent investigation and management of acute knee dislocations at a regional trauma centre. Introduction. Knee dislocation requires high energy trauma, and often affects young working adults. The high incidence of associated arterial, neurological, ligamentous, and other soft tissue injuries, can produce potentially devastating outcomes. Rapid mobilisation of traditionally distinct surgical teams, with urgent vascular imaging and emergency surgery are often necessary. The extent and severity of ligamentous damage may require multiple operations to repair. Methods. A retrospective nine-year study of knee dislocations managed in the Trauma and Orthopaedic Department of the Royal Hospitals, Belfast was performed using a Fractures Outcomes Research Database (FORD), a chart review, and a review of relevant radiology. Demographic data, mechanisms of injury, associated neurovascular injuries, ligamentous damage, and operative intervention were recorded. Results. 15 patients were identified over 9 years (2000-2008 inclusive). Mean age at injury was 38 years, median 37. 14 (93%) of patients were male, 1 (7%) was female. 6 injuries (40%) were sport-related, 3 (20%) occurred as a result of road traffic collisions, 5 (33%) were accidents in the workplace, and 1 (7%) was a result of a fall while intoxicated with alcohol. 5 (33%) patients experienced a common peroneal nerve palsy. 10 (67%) received vascular imaging, and 2 (13%) underwent vascular surgery as part of the initial theatre episode. All 15 dislocations led to some degree of structural soft tissue knee injuries. These included 12 (80%) anterior cruciate ligaments, 8 (53%) posterior cruciate ligaments, 7 (47%) lateral collateral ligaments, and 5 (33%) medial collateral ligaments. 3 posterolateral corner injuries required repair. Of the 15 patients, 2 (13%) underwent no operative procedures following closed reduction, and the remaining 13 patients had 21 distinct theatre episodes recorded between them. 2 fasciotomies for compartment syndrome, and 2 common peroneal nerve decompression/explorations were performed in the initial theatre episode. 3 patients (20%) were managed with an external fixator initially. 1 patient (7%) developed complications and required trans-femoral amputation. Conclusions. Knee dislocation remains uncommon, and even major centres may receive only a few injuries per year. Orthopaedic, Vascular and Plastic surgeons, as well as Emergency Physicians and Radiologists must remain vigilant to the challenge which this injury can present, and the opportunity for excellent outcomes through a coordinated approach with close communication, awareness of injury patterns, and availability of theatre and imaging resources


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 49 - 49
1 Jul 2012
Goodson MW Rath NK White SP John A Forster MC
Full Access

NICE guidelines state patients undergoing elective TKR receive post-operative chemical prophylaxis unless contraindicated, following guideline implementation our aim was to determine VTE incidence and wound complication outcomes related to administration of Rivaroxaban or Enoxaparin. From April to October 2010 we prospectively studied 294 patients having primary or revision TKR. Each received either Rivaroxoban (n=219), Enoxaparin (n=68), UHF 5000 units (n=4) or no thromboprohylaxis (n=3) post-operatively. Primary outcome was identification of symptomatic post-operative VTE incidence and compared incidence over the same period in 2009 when aspirin was the standard chemical prophylaxis for VTE. Secondary outcomes were prolonged wound oozing rates and wound washout. VTE occurred in 3 of 219 patients (2 PE, 1 DVT) receiving Rivaroxaban, and 1 PE in a patient who did not receive any thromboprophylaxis. No patients prescribed Enoxaparin developed VTE. In the same period 2009 there were 21 confirmed PEs in 512 patients undergoing TKR. This was statistically significant (Chi squared test p=0.02). Prolonged oozing was noted in 3 patients receiving Enoxaparin, and 17 patients receiving Rivaroxaban. 6 patients treated with Rivaroxaban returned to theatre, 3 for continuous ooze, 2 for wound dehiscence and 1 for infection. During the same period in 2009, there was only 1 return to theatre for haematoma washout. (Chi squared test; p=0.02). Following the NICE guidelines, there is a reduction in the PE rate following TKR but there is an increase in the overall return to theatre rate


Bone & Joint Open
Vol. 4, Issue 11 | Pages 889 - 898
23 Nov 2023
Clement ND Fraser E Gilmour A Doonan J MacLean A Jones BG Blyth MJG

Aims

To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA).

Methods

This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 914 - 918
1 Jul 2012
Jameson SS Baker PN Charman SC Deehan DJ Reed MR Gregg PJ Van der Meulen JH

We compared thromboembolic events, major haemorrhage and death after knee replacement in patients receiving either aspirin or low-molecular-weight heparin (LMWH). Data from the National Joint Registry for England and Wales were linked to an administrative database of hospital admissions in the English National Health Service. A total of 156 798 patients between April 2003 and September 2008 were included and followed for 90 days. Multivariable risk modelling was used to estimate odds ratios adjusted for baseline risk factors (AOR). An AOR < 1 indicates that risk rates are lower with LMWH than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically significant differences between the aspirin and LMWH groups in the rate of pulmonary embolism (0.49% vs 0.45%, AOR 0.88 (95% confidence interval (CI) 0.74 to 1.05); p = 0.16), 90-day mortality (0.39% vs 0.45%, AOR 1.13 (95% CI 0.94 to 1.37); p = 0.19) or major haemorrhage (0.37% vs 0.39%, AOR 1.01 (95% CI 0.83 to 1.22); p = 0.94). There was a significantly greater likelihood of needing to return to theatre in the aspirin group (0.26% vs 0.19%, AOR 0.73 (95% CI 0.58 to 0.94); p = 0.01). Between patients receiving LMWH or aspirin there was only a small difference in the risk of pulmonary embolism, 90-day mortality and major haemorrhage. These results should be considered when the existing guidelines for thromboprophylaxis after knee replacement are reviewed