Advertisement for orthosearch.org.uk
Results 1 - 20 of 32
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 85 - 90
1 Jun 2020
Blevins JL Rao V Chiu Y Lyman S Westrich GH

Aims. The purpose of this investigation was to determine the relationship between height, weight, and sex with implant size in total knee arthroplasty (TKA) using a multivariate linear regression model and a Bayesian model. Methods. A retrospective review of an institutional registry was performed of primary TKAs performed between January 2005 and December 2016. Patient demographics including patient age, sex, height, weight, and body mass index (BMI) were obtained from registry and medical record review. In total, 8,100 primary TKAs were included. The mean age was 67.3 years (SD 9.5) with a mean BMI of 30.4 kg/m. 2. (SD 6.3). The TKAs were randomly split into a training cohort (n = 4,022) and a testing cohort (n = 4,078). A multivariate linear regression model was created on the training cohort and then applied to the testing cohort . A Bayesian model was created based on the frequencies of implant sizes in the training cohort. The model was then applied to the testing cohort to determine the accuracy of the model at 1%, 5%, and 10% tolerance of inaccuracy. Results. Height had a relatively strong correlation with implant size (femoral component anteroposterior (AP) Pearson correlation coefficient (ρ) = 0.73, p < 0.001; tibial component mediolateral (ML) ρ = 0.77, p < 0.001). Weight had a moderately strong correlation with implant size, (femoral component AP ρ = 0.46, p < 0.001; tibial ML ρ = 0.48, p < 0.001). There was a significant linear correlation with height, weight, and sex with implant size (femoral component R. 2. = 0.607, p < 0.001; tibial R. 2. = 0.695, p < 0.001). The Bayesian model showed high accuracy in predicting the range of required implant sizes (94.4% for the femur and 96.6% for the tibia) accepting a 5% risk of inaccuracy. Conclusion. Implant size was correlated with basic demographic variables including height, weight, and sex. The linear regression and Bayesian models accurately predicted required implant sizes across multiple manufacturers based on height, weight, and sex alone. These types of predictive models may help improve operating room and implant supply chain efficiency. Level of Evidence: Level IV. Cite this article: Bone Joint J 2020;102-B(6 Supple A):85–90


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1416 - 1425
1 Dec 2024
Stroobant L Jacobs E Arnout N Van Onsem S Tampere T Burssens A Witvrouw E Victor J

Aims

Approximately 10% to 20% of knee arthroplasty patients are not satisfied with the result, while a clear indication for revision surgery might not be present. Therapeutic options for these patients, who often lack adequate quadriceps strength, are limited. Therefore, the primary aim of this study was to evaluate the clinical effect of a novel rehabilitation protocol that combines low-load resistance training (LL-RT) with blood flow restriction (BFR).

Methods

Between May 2022 and March 2024, we enrolled 45 dissatisfied knee arthroplasty patients who lacked any clear indication for revision to this prospective cohort study. All patients were at least six months post-surgery and had undergone conventional physiotherapy previously. The patients participated in a supervised LL-RT combined with BFR in 18 sessions. Primary assessments included the following patient-reported outcome measures (PROMs): Knee injury and Osteoarthritis Outcome Score (KOOS); Knee Society Score: satisfaction (KSSs); the EuroQol five-dimension five-level questionnaire (EQ-5D-5L); and the pain catastrophizing scale (PCS). Functionality was assessed using the six-minute walk Test (6MWT) and the 30-second chair stand test (30CST). Follow-up timepoints were at baseline, six weeks, three months, and six months after the start.


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims

Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.

Methods

A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 432 - 441
5 Jun 2023
Kahlenberg CA Berube EE Xiang W Manzi JE Jahandar H Chalmers BP Cross MB Mayman DJ Wright TM Westrich GH Imhauser CW Sculco PK

Aims

Mid-level constraint designs for total knee arthroplasty (TKA) are intended to reduce coronal plane laxity. Our aims were to compare kinematics and ligament forces of the Zimmer Biomet Persona posterior-stabilized (PS) and mid-level designs in the coronal, sagittal, and axial planes under loads simulating clinical exams of the knee in a cadaver model.

Methods

We performed TKA on eight cadaveric knees and loaded them using a robotic manipulator. We tested both PS and mid-level designs under loads simulating clinical exams via applied varus and valgus moments, internal-external (IE) rotation moments, and anteroposterior forces at 0°, 30°, and 90° of flexion. We measured the resulting tibiofemoral angulations and translations. We also quantified the forces carried by the medial and lateral collateral ligaments (MCL/LCL) via serial sectioning of these structures and use of the principle of superposition.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1231 - 1239
1 Nov 2024
Tzanetis P Fluit R de Souza K Robertson S Koopman B Verdonschot N

Aims

The surgical target for optimal implant positioning in robotic-assisted total knee arthroplasty remains the subject of ongoing discussion. One of the proposed targets is to recreate the knee’s functional behaviour as per its pre-diseased state. The aim of this study was to optimize implant positioning, starting from mechanical alignment (MA), toward restoring the pre-diseased status, including ligament strain and kinematic patterns, in a patient population.

Methods

We used an active appearance model-based approach to segment the preoperative CT of 21 osteoarthritic patients, which identified the osteophyte-free surfaces and estimated cartilage from the segmented bones; these geometries were used to construct patient-specific musculoskeletal models of the pre-diseased knee. Subsequently, implantations were simulated using the MA method, and a previously developed optimization technique was employed to find the optimal implant position that minimized the root mean square deviation between pre-diseased and postoperative ligament strains and kinematics.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1360 - 1368
1 Oct 2016
Waterson HB Clement ND Eyres KS Mandalia VI Toms AD

Aims. Our aim was to compare kinematic with mechanical alignment in total knee arthroplasty (TKA). Patients and Methods. We performed a prospective blinded randomised controlled trial to compare the functional outcome of patients undergoing TKA in mechanical alignment (MA) with those in kinematic alignment (KA). A total of 71 patients undergoing TKA were randomised to either kinematic (n = 36) or mechanical alignment (n = 35). Pre- and post-operative hip-knee-ankle radiographs were analysed. The knee injury and osteoarthritis outcome score (KOOS), American Knee Society Score, Short Form-36, Euro-Qol (EQ-5D), range of movement (ROM), two minute walk, and timed up and go tests were assessed pre-operatively and at six weeks, three and six months and one year post-operatively. Results. A total of 78% of the kinematically aligned group (28 patients) and 77% of the mechanically aligned group (27 patients) were within 3° of their pre-operative plan. There were no statistically significant differences in the mean KOOS (difference 1.3, 95% confidence interval (CI) -9.4 to 12.1, p = 0.80), EQ-5D (difference 0.8, 95% CI -7.9 to 9.6, p = 0.84), ROM (difference 0.1, 95% CI -6.0 to 6.1, p = 0.99), two minute distance tolerance (difference 20.0, 95% CI -52.8 to 92.8, p = 0.58), or timed up and go (difference 0.78, 95% CI -2.3 to 3.9, p = 0.62) between the groups at one year. Conclusion. Kinematically aligned TKAs appear to have comparable short-term results to mechanically aligned TKAs with no significant differences in function one year post-operatively. Further research is required to see if any theoretical long-term functional benefits of kinematic alignment are realised or if there are any potential effects on implant survival. Cite this article: Bone Joint J 2016;98-B:1360–8


Bone & Joint Open
Vol. 3, Issue 6 | Pages 470 - 474
7 Jun 2022
Baek J Lee SC Ryu S Kim J Nam CH

Aims

The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up.

Methods

From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1373 - 1379
1 Aug 2021
Matar HE Bloch BV Snape SE James PJ

Aims

Single-stage revision total knee arthroplasty (rTKA) is gaining popularity in treating chronic periprosthetic joint infections (PJIs). We have introduced this approach to our clinical practice and sought to evaluate rates of reinfection and re-revision, along with predictors of failure of both single- and two-stage rTKA for chronic PJI.

Methods

A retrospective comparative cohort study of all rTKAs for chronic PJI between 1 April 2003 and 31 December 2018 was undertaken using prospective databases. Patients with acute infections were excluded; rTKAs were classified as single-stage, stage 1, or stage 2 of two-stage revision. The primary outcome measure was failure to eradicate or recurrent infection. Variables evaluated for failure by regression analysis included age, BMI, American Society of Anesthesiologists grade, infecting organisms, and the presence of a sinus. Patient survivorship was also compared between the groups.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1254 - 1260
1 Jul 2021
Calabro L Clement ND MacDonald D Patton JT Howie CR Burnett R

Aims

The primary aim of this study was to assess whether non-fatal postoperative venous thromboembolism (VTE) within six months of surgery influences the knee-specific functional outcome (Oxford Knee Score (OKS)) one year after total knee arthroplasty (TKA). Secondary aims were to assess whether non-fatal postoperative VTE influences generic health and patient satisfaction at this time.

Methods

A study of 2,393 TKAs was performed in 2,393 patients. Patient demographics, comorbidities, OKS, EuroQol five-dimension score (EQ-5D), and Forgotten Joint Score (FJS) were collected preoperatively and one year postoperatively. Overall patient satisfaction with their TKA was assessed at one year. Patients with VTE within six months of surgery were identified retrospectively and compared with those without.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 176 - 180
1 Jun 2020
Lee G Colen DL Levin LS Kovach SJ

Aims

The integrity of the soft tissue envelope is crucial for successful treatment of infected total knee arthroplasty (TKA). The purpose of this study was to evaluate the rate of limb salvage, infection control, and clinical function following microvascular free flap coverage for salvage of the infected TKA.

Methods

We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and seven women with a mean age of 61.2 years (39 to 81). The median number of procedures performed prior to soft tissue coverage was five (2 to 9) and all patients had failed at least one two-stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 115 - 120
1 Jul 2019
Hooper J Schwarzkopf R Fernandez E Buckland A Werner J Einhorn T Walker PS

Aims

This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty.

Materials and Methods

Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1348 - 1355
1 Nov 2019
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar M Turgeon T

Aims

A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA).

Patients and Methods

Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear.


Bone & Joint Research
Vol. 8, Issue 11 | Pages 535 - 543
1 Nov 2019
Mohammad HR Campi S Kennedy JA Judge A Murray DW Mellon SJ

Objectives

The aim of this study was to determine the polyethylene wear rate of Phase 3 Oxford Unicompartmental Knee Replacement bearings and to investigate the effects of resin type and manufacturing process.

Methods

A total of 63 patients with at least ten years’ follow-up with three bearing types (1900 resin machined, 1050 resin machined, and 1050 resin moulded) were recruited. Patients underwent full weight-bearing model-based radiostereometric analysis to determine the bearing thickness. The linear wear rate was estimated from the change in thickness divided by the duration of implantation.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims

The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?

Patients and Methods

A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 98 - 103
1 Jul 2019
Premkumar A Lovecchio FC Stepan JG Sculco PK Jerabek SA Gonzalez Della Valle A Mayman DJ Pearle AD Alexiades MM Albert TJ Cross MB Haas SB

Aims

The aim of this study was to determine the general postoperative opioid consumption and rate of appropriate disposal of excess opioid prescriptions in patients undergoing primary unilateral total knee arthroplasty (TKA).

Patients and Methods

In total, 112 patients undergoing surgery with one of eight arthroplasty surgeons at a single specialty hospital were prospectively enrolled. Three patients were excluded for undergoing secondary procedures within six weeks. Daily pain levels and opioid consumption, quantity, and disposal patterns for leftover medications were collected for six weeks following surgery using a text-messaging platform.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 70 - 76
1 Jul 2019
Nowak LL Schemitsch EH

Aims

To evaluate the influence of discharge timing on 30-day complications following total knee arthroplasty (TKA).

Patients and Methods

We identified patients aged 18 years or older who underwent TKA between 2005 and 2016 from the American College of Surgeons’ National Surgical Quality Improvement Program (NSQIP) database. We propensity score-matched length-of-stay (LOS) groups using all relevant covariables. We used multivariable regression to determine if the rate of complications and re-admissions differed depending on LOS.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 793 - 798
1 Jun 2017
Anderson FL Koch CN Elpers ME Wright TM Haas SB Heyse TJ

Aims

We sought to establish whether an oxidised zirconium (OxZr) femoral component causes less loss of polyethylene volume than a cobalt alloy (CoCr) femoral component in total knee arthroplasty.

Materials and Methods

A total of 20 retrieved tibial inserts that had articulated with OxZr components were matched with 20 inserts from CoCr articulations for patient age, body mass index, length of implantation, and revision diagnosis. Changes in dimensions of the articular surfaces were compared with those of pristine inserts using laser scanning. The differences in volume between the retrieved and pristine surfaces of the two groups were calculated and compared.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1028 - 1036
1 Aug 2017
Chawla H Nwachukwu BU van der List JP Eggman AA Pearle AD Ghomrawi HM

Aims

Patellofemoral arthroplasty (PFA) has experienced significant improvements in implant survivorship with second generation designs. This has renewed interest in PFA as an alternative to total knee arthroplasty (TKA) for younger active patients with isolated patellofemoral osteoarthritis (PF OA). We analysed the cost-effectiveness of PFA versus TKA for the management of isolated PF OA in the United States-based population.

Patients and Methods

We used a Markov transition state model to compare cost-effectiveness between PFA and TKA. Simulated patients were aged 60 (base case) and 50 years. Lifetime costs (2015 United States dollars), quality-adjusted life year (QALY) gains and incremental cost-effectiveness ratio (ICER) were calculated from a healthcare payer perspective. Annual rates of revision were derived from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. Deterministic and probabilistic sensitivity analysis was performed for all parameters against a $50 000/QALY willingness to pay.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 475 - 482
1 Apr 2017
Hamilton TW Pandit HG Inabathula A Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims

While medial unicompartmental knee arthroplasty (UKA) is indicated for patients with full-thickness cartilage loss, it is occasionally used to treat those with partial-thickness loss. The aim of this study was to investigate the five-year outcomes in a consecutive series of UKAs used in patients with partial thickness cartilage loss in the medial compartment of the knee.

Patients and Methods

Between 2002 and 2014, 94 consecutive UKAs were undertaken in 90 patients with partial thickness cartilage loss and followed up independently for a mean of six years (1 to 13). These patients had partial thickness cartilage loss either on both femur and tibia (13 knees), or on either the femur or the tibia, with full thickness loss on the other surface of the joint (18 and 63 knees respectively). Using propensity score analysis, these patients were matched 1:2 based on age, gender and pre-operative Oxford Knee Score (OKS) with knees with full thickness loss on both the femur and tibia. The functional outcomes, implant survival and incidence of re-operations were assessed at one, two and five years post-operatively. A subgroup of 36 knees in 36 patients with partial thickness cartilage loss, who had pre-operative MRI scans, was assessed to identify whether there were any factors identified on MRI that predicted the outcome.