Due to shorter hospital stays and faster patient rehabilitation
Abstract. Introduction. Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment. Methods. We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the long-term results of a previously published cohort of knees. Our series of UKA with per-operative arthroscopy (Group 1) was compared to all Oxford UKA (Group 2) and all UKA in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) (Group 3). Results. The 14-year cumulative percentage revision (CPR) was 18.5% (95% CI 12.7, 26.4) for group 1, 19.7% (95% CI 18.8, 20.6) for group 2, and 19.2% (95% CI 18.5, 19.8) for group 3. There was no statistically significant difference in the (CPR) for the entire period when group 1 was compared to groups 2 or 3. Progression of arthritis was the indication for revision in similar proportions for the three groups (Group 1: 32.3%, Group 2: 35.7% and Group 3: 33.5%). Following per-operative arthroscopy 21.6% (77/356) of knees underwent a change of surgical plan from UKA to TKA. Conclusion. Per-operative arthroscopy may improve medium-term medial
Aims. Primary (or spontaneous) and secondary osteonecrosis of the knee
can lead to severe joint degeneration, for which either total or
unicompartmental arthroplasty may be considered. However, there
are limited studies analyzing outcomes of
A review of current literature describes varying 10-year survival rates for the Oxford Unicompartmental Knee Replacement (Biomet Orthopedics Inc, Warsaw, Ind). Application of rigorous indications and meticulous surgical technique are two factors considered to reduce revision rates. A retrospective case-note review was conducted for 96 patients (128 knees) aged 42–89 (mean 57) who had an Oxford unicompartmental knee replacement for medial compartment osteoarthritis between January 2000 and January 2011. All procedures were performed, or directly supervised, by one 5 surgeons. The aim of the study was to ascertain the rate of revision to bicompartmental knee replacement and any associated contributory factors. Of the 128
Introduction: Unicomparmental knee replacements have a long clinical history of success as well as failure. Recently, in Australia some 40% of knee surgery performed consists of
The Oxford
The purpose of this study is to assess the long term results of combined ACL reconstruction and unicompartmental knee replacements (UKR). These patients have been selected for this combined operation due to their combination of instability symptoms from an absent ACL and unicompartmental arthritis. Retrospective review of 44 combined UKR and ACL reconstruction by a single surgeon. Surgeries included both medial and lateral UKR combined with either revision ACL reconstruction or primary ACL reconstruction. Patient reported outcomes were obtained preoperatively, at one year, 5 years and 10 years. Revision rate was followed up over 13 years for a mean of 7.4 years post-surgery. The average Oxford score at one year was 43 with an average increase from pre-operation to 1 year post operation of 15. For the 7 patients with 10 year follow up average oxford score was 42 at 1 year, 43 at 5 years and 45 at 10 years. There were 5 reoperations. 2 for revision to total knee arthroplasty and 1 for an exchange of bearing due to wear. The other 2 were the addition of another UKR. For those requiring reoperation the average time was 8 years. Younger more active patients presenting with ACL deficiency causing instability and unicompartmental arthritis are a difficult group to manage. Combining UKR and ACL reconstruction has scant evidence in regard to long term follow up but is a viable option for this select group. This paper has one of the largest cohorts with a reasonable follow up averaging 7.4 years and a revision rate of 11 percent. Combined unilateral knee replacements and ACL reconstruction can be a successful operation for patients with ACL rupture causing instability and unicompartmental arthritis.
Two computer assisted techniques (CT and a fluoro-guide based system) were used to insert the femoral component of the Oxford Unicompartmental Knee arthroplasty. The accuracy and variability of component positioning were compared. Clinical data was collected pre-operatively and is being collected post-operatively. Standing AP and lateral knee X-rays as well as skyline X-rays were collected pre-operatively and post-operative full length AP and lateral femur X-rays were completed in order to measure alignment of the femoral component. Results are showing accurate insertions of the Oxford knee femoral component using both systems. To review two computer-assisted techniques for inserting Oxford Unicompartmental Knee arthroplasties. CT based and fluro based techniques were compared with regards to accuracy and variability of component positioning. Currently we are able to use either a CT based system or a fluro based system to accurately insert the femoral component of the Oxford Unicompartmental Knee arthroplasty. Computer assist techniques are allowing us to perform minimally invasive arthroplasty procedures with great accuracy. Patients were all seen in a pre-admission clinic where pre-operative clinical survey data were collected. All patients had standing AP and lateral knee X-rays as well as skyline X-rays pre-operatively. Post-perative full length AP and lateral femur X-rays were completed in order to measure alignment of the femoral component. Patients are being followed post-operatively with SF-36, WOMAC, Knee Society Scores, and X-rays. Patients being operated on with the CT based system had pre operative CT scans. Intra-operatively a DRB was fixed to the patient’s femur and the chosen computer assisted technique was used to direct the rotation of the tibial cut as well as the alignment of the femoral cutting jig. To date we have completed seventeen computer assisted Oxford
Two computer assisted techniques (CT and a fluoro-guide based system) were used to insert the femoral component of the Oxford Unicompartmental Knee arthroplasty. The accuracy and variability of component positioning were compared. Clinical data was collected pre-operatively and is being collected post-operatively. Standing AP and lateral knee X-rays as well as skyline X-rays were collected pre-operatively and post-operative full length AP and lateral femur X-rays were completed in order to measure alignment of the femoral component. Results are showing accurate insertions of the Oxford knee femoral component using both systems. To review two computer-assisted techniques for inserting Oxford Unicompartmental Knee arthroplasties. CT based and fluro based techniques were compared with regards to accuracy and variability of component positioning. Currently we are able to use either a CT based system or a fluro based system to accurately insert the femoral component of the Oxford Unicompartmental Knee arthroplasty. Computer assist techniques are allowing us to perform minimally invasive arthroplasty procedures with great accuracy. Patients were all seen in a pre-admission clinic where pre-operative clinical survey data were collected. All patients had standing AP and lateral knee X-rays as well as skyline X-rays pre-operatively. Post-perative full length AP and lateral femur X-rays were completed in order to measure alignment of the femoral component. Patients are being followed post-operatively with SF-36, WOMAC, Knee Society Scores, and X-rays. Patients being operated on with the CT based system had pre operative CT scans. Intra-operatively a DRB was fixed to the patient’s femur and the chosen computer assisted technique was used to direct the rotation of the tibial cut as well as the alignment of the femoral cutting jig. To date we have completed seventeen computer assisted Oxford
Ultra-high molecular weight polyethylene (UHMWPE) is a commonly used as bearing material in joint replacement devices. UHMWPE implants can be hard to see on a standard X-ray because UHMWPE does not readily attenuate X-rays. Radiopaque UHMWPE would enable direct imaging of the bearing both during and after surgery, providing in vivo assessment of bearing position, dislocation or fracture, and potentially a direct measure of wear. The X-ray attenuation of UHMWPE was increased by diffusing an FDA approved contrast agent (Lipiodol) into UHMWPE parts (Zaribaf et al, 2018). The aim of this study was to evaluate the optimal level of radiopacity for a UHMWPE bearing. Samples of un-irradiated medical grade UHMWPE (GUR 1050) were machined into 4mm standard medium Oxford Unicompartmental bearings. Samples were immersed in Lipiodol Ultra Fluid (Guerbert, France) at elevated temperatures (85 °C, 95 °C and 105 °C) for 24 h to achieve three different levels of radiopacity. A phantom set-up was used for X-ray imaging; the phantom contained two perspex rods to represent bone, with the metallic tibial tray and polyethylene bearing fixed to the end of one rod and the metallic femoral component fixed to the other rod. Radiographs of the samples were taken (n=5) with the components positioned in full extension. To ensure consistency, the images of all the samples were taken simultaneously alongside an untreated part. The results of our ongoing study demonstrate that the radiopacity of UHMWPE can be enhanced using Lipiodol and the parts are visible in a clinical radiographs. The identification of the optimal treatment from a clinical perspective is ongoing; we are currently running a survey with clinicians to find the consensus on the optimal radiopacity taking into account the metallic components and alignment. Future work will involve a RSA study to assess the feasibility of measuring wear directly from the bearing.
Unicompartmental knee arthroplasty (UKA) is a potential treatment
for isolated bone on bone osteoarthritis when limited to a single
compartment. The risk for revision of UKA is three times higher
than for total knee arthroplasty (TKA). The aim of this review was
to discuss the different revision options after UKA failure. A search was performed for English language articles published
between 2006 and 2016. After reviewing titles and abstracts, 105
papers were selected for further analysis. Of these, 39 papers were
deemed to contain clinically relevant data to be included in this review.Objectives
Materials and Methods
The number of medial unicompartmental knee replacements (UKR) performed for arthritis has increased and as such, revisions to total knee replacement (TKR) is increasing. Previous studies have investigated survivorship of UKR to TKR revision and functional outcomes compared to TKR to TKR revision, but have failed to detail the surgical considerations involved in these revisions. Our objectives are to investigate the detailed surgical considerations involved in UKR to TKR revisions. This study is a retrospective comparative analysis of a prospectively collected database. From 2005 to 2017, 61 revisions of UKR to TKR were completed at a single center. Our inclusion criteria included: revision of UKR to TKR or TKR to TKR with minimum 1 year follow-up. Our exclusion criteria include: single component and liner revisions and revision for infection. The 61 UKR to TKR revisions were matched 2:1 with respect to age, ASA and BMI to a group of 122 TKR to TKR revisions. The following data was collected: indication for and time to revision, operative skin to skin surgical time, the use of specialized equipment (augment size/location, stem use), intraoperative and postoperative complications, re-operations and outcome scores (WOMAC, Oxford 12, SF 12, satisfaction score).Introduction
Methods
Laboratory experiments and computational models were used to predict bone-implant micromotion and bone strains induced by the cemented and cementless Biomet Oxford medial Unicompartmental Knee Replacement (UKR) tibial implants. Ten fresh frozen cadaveric knees were implanted with cementless medial mobile UKRs, the tibias were separated and all the soft tissues were resected. Five strain gauge rosettes were attached to each tibia. Four Linear Transducers were used to measure the superior-inferior and transverse bone-implant micromotions. The cementless UKRs were assessed with 10 cycles of 1kN compressive load at 4 different bearing positions. The bone-constructs were re-assessed following cementation of the equivalent UKR. The cemented bone-implant constructs were also assessed for strain and micromotion under 10000 cycles of 10mm anterior-posterior bearing movement at 2Hz and 1kN load. The cadaveric specimens were scanned using Computed Tomography, and 3D computer models were developed using Finite Element method to predict strain and micromotion under various daily loads. Results verify computer model predictions and show bone strain pattern differences, with cemented implants distributing the loads more evenly through the bone than cementless implants. Although cementless implants showed micromotions which were greater than computer predictions, the micromotions were as expected significantly greater than those of cemented implants. The computer models reveal that bone strains approach 70% of their failure limit at the posterior and anterior corners adjoining the sagittal and transverse cuts (less pronounced in cemented implants). The base of the keel also develops high strains which can approach failure depending on the amount the implant press-fit. The contributions of the anterior cruciate and patellar tendon forces exacerbate the strains in these regions. This may explain why fractures emanate from the base of the keel and the sagittal cut.Methods
Results and Discussion
Unicompartmental knee replacements (unis) offer an early option for the treatment of osteoarthritis. However there is no standard method for measuring the wear of unis in the laboratory. Most knee simulators are designed for TKA, for which there is an ISO standard. This study is about a wear method for unis, applied to a novel unicompartmental knee replacement (design by PSW). It has a metal-backed UHMWPE femoral component to articulate against a monoblock metallic tibial component. The advantage is reduced resection of strong bone from the proximal tibia for more durable fixation. The femoral component resurfaces the distal end of the femur to a flexion arc of only 42°, the area of cartilage loss in early OA (Fig. 1). We compared this novel bearing couple to the same design but with the usual arrangement of femoral metal and tibial plastic. Our hypothesis was that the wear of the reversed materials would be comparable to conventional and within the range of TKR bearings. The test was conducted on a 4-station Instron-Stanmore force-controlled knee simulator. Both specimen groups (n=4 each) were highly crosslinked UHWMPE stabilized with vitamin E. On each of the four stations, one uni system was mounted on the medial side and one on the lateral, as if a standard TKR was being tested. The ISO-14243-1 walking cycle force-control waveforms were applied for 5 million cycles (Mc) at 1Hz, but with the maximum flexion during the swing phase (usually 58°) curtailed to 35° to maintain the contact within the arc of the femoral component. In-vivo this implant would be inlaid into the distal medial femoral condyle and the articulating surface immediately transitions into native cartilage. In our test set-up there was no secondary surface as such. The reduced flexion occurred during the swing phase where compressive load was low and the effect on the wear would be negligible. Wear was measured gravimetrically at many intervals and corrected by the weight gain of extra two active soak controls per group. After 5 Mc, the average rates of gravimetric weight loss from the UHMWPE femoral and tibial bearings were 4.73±0.266 mg/Mc and 3.07±0.388 mg/Mc, respectively (statistically significantly different, p=0.0007) (Fig. 2). No significant difference was found in wear between medial and lateral placement for specimens of the same type, although the medial side generally wore more. Although the plastic femorals of the reverse design wore more than the plastic tibials, the wear was still low at <5 mg/Mc. The range for typical TKRs using ultra-high molecular weight polyethylene, tested under the same conditions in our laboratory has been 2.85–24.1 mg/Mc. In summary, we adapted the ISO standard TKA wear test for the evaluation of unis, and in this case, a uni with reversed materials. Based on the wear results, this type of ‘early intervention’ design could therefore be a viable option, offering simplicity with less modular parts as well as load sharing with the native articular cartilage.
The revision rate of unicompartmental knee replacement (UKR) in national joint registries is much higher than that of total knee replacements and that of UKR in cohort studies from multiple high-volume centres. The reasons for this are unclear but may be due to incorrect patient selection, inadequate surgical technique, and inappropriate indications for revision. Meniscal bearing UKR has well defined evidence based indications based on preoperative radiographs, the surgical technique can be assessed from post-operative radiographs and the reason for revision from pre-revision radiographs. However, for an accurate assessment aligned radiographs are required. The aim of the study was to determine why the revision rate of UKR in registries is so high by undertaking a radiographic review of revised UKR identified by the United Kingdom's (UK) National Joint Registry (NJR). A novel cross-sectional study was designed. Revised medial meniscal bearing UKR with primary operation registered with the NJR between 2006 and 2010 were identified. Participating centres from all over the country provided blinded pre-operative, post-operative, and pre-revision radiographs. Two observers reviewed the radiographs.Introduction
Methods
The purpose of this paper is to emphasize lateral compartment arthroplasty as efficient method and to discuss postoperative problems by investigating mid-term results (over 5 years) Two hundred and twenty two consecutive unicompartmental knee arthroplasties (UKA) were performed in our hospital between August 1977 and December 1999. Thirty eight joints of 37 patients underwent lateral UKA. There were 8 male and 29 female patients with an average of 65.1 years old. The following prostheses were used: Marmor in 5 patients, Oxford in 1, PCA in 11, and Omnifit in 21. Out of them, 24 joints had follow up over 5 years after replacement. Three patients died of unrelated illness and 3 were lost to follow up. The remaining 18 joints could be followed from 60 to 189 months (average, 99 months). The knee score of the Hospital for Special Surgery (the HSS knee score) was used for clinical evaluation. Clinical results by the HSS knee score showed that 2 joints were judged as “good”, 13 as “fair”, and 3 as “poor” before surgery. After surgery 13 joints were improved to “excellent”, 3 to “good”, and 2 to “fair”. The two joints with fair results had revision surgery. In all, 16 joints had satisfactory results. With radiological evaluation, the average preoperative alignment on standing was 14.9o of valgus angulation and corrected to 6.9 o of valgus. Although radiolucent lines under the tibial component were not found, a radiolucent line was observed and extended to loosening in one femoral component. This patient was successfully revised to another type of UKA 3 years after the index surgery. In the medial compartment, we found slight deterioration of osteoarthritic change in 5 joints. Of these, one patient, needed medial UKA. Lateral UKA is a reliable and successful option compared with other procedures in a patient with low level of physical activity, because the long-term results tend to last and loosening of the tibial components has not been observed as commonly as in medial UKA. However, deterioration of the medial compartment may occur. The alignment after surgery must be in slight valgus for a satisfactory long-term result.
Unicompartmental knee arthroplasty (UKA) has seen renewed interest in recent years and is a viable option for patients with limited degenerative disease of the knee as an alternative to total knee arthroplasty. However, the minimally invasive UKA procedure is challenging, and accurate component alignment is vital to long-term survival. Robotic-assisted UKA allows for greater accuracy of component placement and dynamic intraoperative ligament balancing which may improve clinical patient outcomes. The purpose of this study was to analyse the clinical outcomes in a large, consecutive cohort of patients that underwent robotic-assisted UKA at a single institution with a minimum follow-up of 2 years. The study hypothesis was that robotic-assisted UKA improves patient outcomes by decreasing the rate of revision in comparison to conventional UKA. A search of the institutional joint registry was performed to identify patients that underwent robotic-assisted UKA beginning in August 2008. The patients' electronic medical record was analysed for surgical indication, age at surgery, body mass index (BMI), and American Society of Anesthesiology Physical Status Classification System (ASA). Patient comorbidities were evaluated using the Charlson comorbidity index. Length of surgery and length of hospitalisation were assessed and clinical outcomes were evaluated using the Oxford Knee Score. In addition to postoperative follow-up assessments in clinic, patients without recent follow-up were contacted by telephone to capture the overall revision rate and time to revision.Introduction
Materials and methods
While residual fixed flexion deformity (FFD) in unicompartmental knee arthroplasty (UKA) has been associated with worse functional outcomes, limited evidence exists regarding FFD changes. The objective of this study was to quantify FFD changes in patients with medial unicompartmental knee arthritis undergoing UKA, and investigate any correlation with clinical outcomes. This study included 136 patients undergoing robotic arm-assisted medial UKA between January 2018 and December 2022. The study included 75 males (55.1%) and 61 (44.9%) females, with a mean age of 67.1 years (45 to 90). Patients were divided into three study groups based on the degree of preoperative FFD: ≤ 5°, 5° to ≤ 10°, and > 10°. Intraoperative optical motion capture technology was used to assess pre- and postoperative FFD. Clinical FFD was measured pre- and postoperatively at six weeks and one year following surgery. Preoperative and one-year postoperative Oxford Knee Scores (OKS) were collected.Aims
Methods
The Oxford mobile bearing knee prosthesis (Zimmer Biomet Inc, Warsaw, Ind) is considered a good treatment option for isolated medial compartment knee arthrosis. From February 2001 until August 2016, 1719 primary Oxford medial unicompartmental knee replacement procedures were completed at our center by a group of seven surgeons. We undertook this study to examine the long-term survivorship of the Oxford unicompartmental knee replacement looking at survivorship and reasons for failure. A retrospective consecutive case series review was completed, and all revisions and re-operations were identified. Conversion to total knee replacement (TKA) was considered a failure. Kaplan-Meier survival analysis was used to calculate the 15-year survivorship of the group overall. We specifically looked at age, gender, BMI and surgeon caseload in addition to the reasons for failure. A statistical analysis was performed and differences in survivorship were compared for the variables listed. A logistic cox regression was performed to explore predictors of revision. Overall 15-year survivorship was 89.9%. Female survivorship of 88.1% was statistically worse than the male group at 91.8% (p=0.018). Younger patients (75yrs of age (p= 0.036). There was a large range in surgical case load by individual surgeons (range 17–570 knees). There were no statistically significant differences in age, BMI, or gender when comparing the individual surgeon groups. There was a large range in 15-year survivorship between individual surgeons (range 78.3% – 95%). Overall the most common reason for revision was due to wear of the unreplaced portion of the knee (lateral and/or patella-femoral joint) followed by aseptic loosening, polyethylene dislocation, infection or persistent pain. The 15-year survivorship results of the Oxford medial unicompartmental knee replacement at our center compares favourably to other published series and large registry data series. We found a reduction in survivorship in female patients and younger patients (< 5 5yrs). There were also significant differences in survivorship based on the individual surgeon. A more selective patient approach yielded the best long-term survivorship and equivalent to that of total knee replacement. We therefore suggest using a more selective approach when choosing patients for a medial unicompartmental knee replacement with the Oxford mobile bearing prosthesis in order to enhance long-term survivorship.
Medium-term survivorship of the Oxford phase
3 unicompartmental knee replacement (UKR) has not yet been established
in an Asian population. We prospectively evaluated the outcome of
400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at
the time of operation of 69 years (48 to 82). The mean follow-up
was 5.2 years (1 to 10). Clinical and radiological assessment was
carried out pre- and post-operatively. At five years, the mean Knee
Society knee and functional scores had increased significantly from
56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and
from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively.
The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively
to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival
rate was 94% (95% confidence interval 90.1 to 98.0). A total of
14 UKRs (3.5%) required revision. The most common reason for revision
was dislocation of the bearing in 12 (3%). Conversion to a total
knee replacement was required in two patients who developed osteoarthritis
of the lateral compartment. This is the largest published series of UKR in Korean patients.
It shows that the mid-term results after a minimally invasive Oxford
phase 3 UKR can yield satisfactory clinical and functional results
in this group of patients.