Introduction and Objective. Malunion after trauma can lead to coronal plane malalignment in the lower limb. The mechanical hypothesis suggests that this alters the load distribution in the knee joint and that that this increased load may predispose to compartmental arthritis. This is generally accepted in the orthopaedic community and serves as the basis guiding deformity correction after malunion as well as congenital or insidious onset malalignment. Much of the literature surrounding the contribution of lower limb alignment to arthritis comes from cohort studies of incident osteoarthritis. There has been a causation dilemma perpetuated in a number of studies - suggesting malalignment does not contribute to, but is instead a consequence of, compartmental arthritis. In this investigation the relationship between compartmental (medial or lateral) arthritis and coronal plane malalignment (varus or valgus) in patients with post traumatic unilateral limb deformity was examined. This represents a specific niche cohort of patients in which worsened compartmental knee arthritis after extra-articular injury must rationally be attributed to malalignment. Materials and Methods. The picture archiving system was searched to identify all 1160 long leg x ray films available at a major metropolitan trauma center over a 12-year period. Images were screened for inclusion and exclusion criteria, namely patients >10 years after traumatic long bone fracture without contralateral injury or arthroplasty to give 39 cases. Alignment was measured according to established surgical standards on long leg films by 3 independent reviewers, and arthritis scores Osteoarthritis Research Society International (OARSI) and Kellegren-Lawrence (KL) were recorded independently for each compartment of both knees. Malalignment was defined conservatively as mechanical axis deviation outside of 0–20 mm medial from centre of the knee, to give 27 patients. Comparison of mean compartmental arthritis score was performed for patients with varus and valgus malalignment, using Analysis of Variance and linear regression. Results. In knees with varus malalignment there was a greater mean arthritis score in the medial compartment compared to the contralateral knee, with OARSI scores 5.69 vs 3.86 (0.32, 3.35 95% CI; p<0.05) and KL 2.92 vs 1.92 (0.38, 1.62; p<0.005). There was a similar trend in
Constitutional knee varus increases the risk of medial OA disease due to increase in the knee adduction moment and shifting of the mechanical axis medially. Hueter-Volkmann’s law states that the amount of load experienced by the growth plate during development influences the bone morphology. For this reason, heightened sports activity during growth is associated with constitutional varus due to added knee adduction moment. In early OA, X-rays often show a flattened medial femoral condyle extension facet (EF). However, it is unknown whether this is a result of osteoarthritic wear, creep deformation over decades of use, or an outcome of Hueter-Volkmann’s law during development. A larger and flattened medial EF can bear more weight, due to increased load distribution. However, a flattened EF may also extrude the meniscus, leading meniscus degeneration and joint failure. Therefore, this study aimed to investigate whether varus knees have flattened medial EFs of both femur and tibia in a cohort of patients with no signs yet of bony attrition. Segmentation and morphology analysis was conducted using Materialise software (version 8.0, Materialise Inc., Belgium). This study excluded knees with bony attrition of the EFs based on Ahlbäck criteria, intraoperative findings, and operation notes history. Standard reference frames were used for both the femur and tibia to ensure reliable and repeatable measurements. The hip-knee-angle (HKA) angle defined varus or
Background. New marker free motion analysis systems are being used extensively in the area of sports medicine and physiotherapy. The accuracy and validity of use in an orthopaedic setting have not been fully assessed for these newer marker free motion analysis systems. The aim of this study is to compare leg length and varus/
A correct ligament loading following TKA surgery is believed to minimize instability and improve patient satisfaction. The evaluation of the ligament stress or strain is however impractical in a surgical setting. Alternatively, tibial trial components containing force sensors have the potential to indirectly assess the ligament loading. These instrumented components quantify the medial and lateral forces in the tibiofemoral joint. Although this method finds clinical application already, the target values for both the force magnitude and medial / lateral force ratio under surgical conditions remain uncertain. A total of eight non-arthritic cadaveric knees have been tested mimicking surgical conditions. Therefore, the specimens are mounted in a custom knee simulator. This simulator allows to test full lower limb specimens, providing kinematic freedom throughout the range of motion. Knee flexion is obtained by lifting the femur (thigh pull). Knee kinematics are simultaneously recorded by means of a navigation system and based on the mechanical axis of the femur and tibia. In addition, the load transferred through the medial and lateral compartment of the knee is monitored. Therefore, a 2.4 mm thick sawing blade is used to machine a slot in the tibia perpendicular to the mechanical axis, at the location of the tibial cut in TKA surgery. A complete disconnection was thereby assured between the tibial plateau and the distal tibia. To fill the created gap, custom 3D printed shims were inserted. Through their specific geometry, these shims create a load deviation between two Tekscan pressure pads on the medial and lateral side. Following the insertion of the shims, the knee was closed before performing the kinematic and kinetic tests. Seven specimens showed a limited varus throughout the range of motion (ranging from 1° to 7° varus). The other knee was in valgus (4° valgus). Amongst varus knees, the results were very consistent, indicating high loads in full extension. Subsequently, the loads decrease as the knee flexes and eventually vanishes on the lateral side. This leads to consistently high compartmental load ratios (medial load / total load) in flexion. In full extension the screw-home mechanism results in increased loads, both medially and laterally. Upon flexion, the lateral loads disappear. This is attributed to slackening of the lateral collateral ligament, in turn linked to the femoral rollback and slope of the lateral compartment. The isometry of the medial collateral ligament contributes on the other hand to the near-constant load in the medial compartment. The above particularly applies for varus knees. The single
Valgus unloader knee braces are a conservative treatment option for medial compartment knee osteoarthritis (OA). These braces are designed to reduce painful, and potentially injurious compressive loading on the damaged medial side of the joint through application of a frontal-plane abduction moment. While some patients experience improvements in pain, function, and joint loading, others see little to no benefit from bracing [1]. Previous biomechanical studies investigating the mechanical effectiveness of bracing have been limited in either their musculoskeletal detail [2] or incorporation of altered external joint moments and forces [3]. The first objective was to model the relative contributions of gait dynamics, muscle forces, and the external brace abduction moment to reducing medial compartment knee loads. The second objective was to determine what factors predict the effectiveness of the valgus unloading brace. Seventeen people with knee OA (8 Female age 54.4 +/− 4.2, BMI 30.00 +/− 4.0 kg/m. 2. , Kellgren-Lawrence range of 1–4 with med. = 3) and 20 healthy age-matched controls participated in this study which was approved by the institutional ethics review board. Subjects walked across a 20m walkway with and without a Donjoy OA Assist knee brace while marker trajectories, ground reaction forces, and lower limb electromyography were recorded. The external moment applied by the brace was estimated by multiplying the brace deformation by is pre-determined brace-stiffness. For each subject, a representative stride was selected for each brace condition. A generic musculokeletal model with two legs, a torso, and 96 muscles was modified to include subject-specific frontal plane alignment and medial and lateral contact locations [4]. Muscle forces, and tibiofemoral contact forces were estimated using static optimization [4]. We defined brace effectiveness as the difference in the peak medial contact force between the braced and the unbraced conditions. A stepwise regression analysis was performed to predict brace effectiveness based on: X-ray frontal plane alignment, medial joint space, KL grade, mass, WOMAC scores, unbraced walking speed, trunk, hip and knee joint angles and moments. The OA Assist brace reduced medial joint loading by approximately 0.1 to 0.2 BW or roughly 10%, during stance. This decrease was primarily due to the external brace abduction moment, and not changes in gait dynamics, or muscle forces. The brace effectiveness could be predicted (R. 2. =0.77) by the KL grade, and the magnitude of the hip adduction moment in early stance (unbraced). The brace was more effective for those that had larger hip adduction moments and for those with more severe OA. The
The patella is an important component of the extensor mechanism of the knee. Patellar fractures need to be fixed if displacement occurs more than 2 mm. Transverse fractures comprise the largest category. Several different techniques for internal fixation have been employed. The aim of this work was to evaluate the results of treatment of transverse patellar fractures with figure of eight wiring through cannulated screws. Twenty patients were included in the study, all suffering from displaced transverse patellar fractures. All were treated by open reduction and internal fixation with figure of eight tension band wire through 4.0 mm cannulated screws. All patients were assessed after 1 month, 3 months and 6 months according to a modified Hospital for special surgery (HSS) knee scoring system. Because varus and
Summary Statement. An MRI-derived subject-specific finite element model of a knee joint was loaded with subject-specific kinetic data to investigate stress and strain distribution in knee cartilage during the stance phase of gait in-vivo. Introduction. Finite element analysis (FEA) has been widely used to predict the local stress and strain distribution at the tibiofemoral joint to study the effects of ligament injury, meniscus injury and cartilage defects on soft tissue loading under different loading conditions. Previous studies have focused on static FEA of the tibiofemoral joint, with few attempts to conduct subject-specific FEA on the knee during physical activity. In one FEA study utilising subject-specific loading during gait, the knee was simplified by using linear springs to represent ligaments. To address the gap that no studies have performed subject-specific FEA at the tibiofemoral joint with detailed structures, the present study aims to develop a highly detailed subject-specific FE model of knee joint to precisely simulate the stress distribution at knee cartilage during the stance phase of the gait cycle. Method. A detailed three-dimensional model of a healthy human knee was developed from MRI images of a living subject, including the main anatomical structures (bones, all principal ligaments, menisci and articular cartilages). The femur, tibia and fibula were considered as rigid bodies, while the menisci and articular cartilage were modelled as linearly elastic, isotropic and homogeneous while the ligaments were considered to be hyperelastic. Loading and boundary condition assignment was based on the kinematic and kinetic data recorded during gait analysis. Ten time intervals during the stance phase of gait were separately simulated to quantify the time–dependent stress distribution throughout the cycle from heel-strike to toe-off. Loading condition of the tibiofemoral joint varys during the gait cycle since the joint angle changes from extension to flextion, therefore different joint angles at relative time interval were determined to accurately simulate the varing loading condition. Results. The compressive stress and tensile strain distributions in the femoral cartilage, tibia cartilage and menisci of each selected time interval during the stance phase of gait cycle were quantified and corresponded to specific amount of varus/
The routine use of a fixed distal femoral resection angle in total knee arthroplasty (TKA) assumes little or no variation in the angle between the anatomical and mechanical femoral axes (FMA angle) in different patients. The aims of this study were threefold, firstly to investigate the distribution of FMA angle in TKA patients, secondly to identify any correlation between the FMA angle and the pre-operative coronal mechanical femoro-tibial (MFT) angle and in addition to assess post-operative MFT angle with fixed or variable distal femoral resection angles. 277 primary TKAs were performed using either fixed or variable distal femoral resection angles (174 and 103 TKAs respectively), with intramedullary femoral and extramedullary tibial jigs. The variable distal femoral resection angles were equal to the FMA angle measured on pre-operative Hip-Knee-Ankle (HKA) digital radiographs for each patient. Outcomes were assessed by measuring the FMA angle and the pre- and post-operative MFT angles on HKA radiographs. The FMA angle ranged from 2° to 9° (mean 5.9°). Both cohorts showed a correlation between FMA and pre-operative MFT angles (fixed: r = -0.499, variable: r = -0.346) with
The understanding of rotational alignment of the distal femur is essential in total knee replacement to ensure that there is correct placement of the femoral component. Many reference axes have been described, but there is still disagreement about their value and mutual angular relationship. Our aim was to validate a geometrically-defined reference axis against which the surface-derived axes could be compared in the axial plane. A total of 12 cadaver specimens underwent CT after rigid fixation of optical tracking devices to the femur and the tibia. Three-dimensional reconstructions were made to determine the anatomical surface points and geometrical references. The spatial relationships between the femur and tibia in full extension and in 90° of flexion were examined by an optical infrared tracking system. After co-ordinate transformation of the described anatomical points and geometrical references, the projection of the relevant axes in the axial plane of the femur were mathematically achieved. Inter- and intra-observer variability in the three-dimensional CT reconstructions revealed angular errors ranging from 0.16° to 1.15° for all axes except for the trochlear axis which had an interobserver error of 2°. With the knees in full extension, the femoral transverse axis, connecting the centres of the best matching spheres of the femoral condyles, almost coincided with the tibial transverse axis (mean difference −0.8°,