Due to widespread cancellations in elective orthopaedic procedures, the number of patients on waiting list for surgery is rising. We aim to determine and quantify if disparities exist between inpatient and day-case orthopaedic waiting list numbers; we also aim to determine if there is a ‘hidden burden’ that already exists due to reductions in elective secondary care referrals. Retrospective data were collected between 1 April 2020 and 31 December 2020 and compared with the same nine-month period the previous year. Data collected included surgeries performed (day-case vs inpatient), number of patients currently on the orthopaedic waiting list (day-case vs inpatient), and number of new patient referrals from primary care and therapy services.Aims
Methods
To assess whether prosthetic femoral stem centralisers have a detrimental effect on the macroporosity of the cement mantle, and if so, whether this is independent of their design and the rate of implantation, 30 identically cast moulded prosthetic femora were divided into 3 groups. Group 1: no centraliser (control), Group 2: centraliser A and Group 3: centraliser B. Using third generation cementation techniques and pressure monitoring, Charnley C-stems +/− the appropriate centraliser were implanted to a constant depth. Half in each group were implanted as rapidly as possible and the other half over 90 seconds. The stems were removed and the cement mantle then underwent a preliminary arthroscopic examination prior to being sectioned transversely at 3 constant levels. Each level was then photographed and digitally enlarged to a known scale to allow examination and determination of any cement voids (macropores) surface area. There were no significant pressure fluctuations between the groups. Preliminary arthroscopic examination revealed that cement voids appeared more common when a centraliser was used. This difference was confirmed (p=0.002) following sectioning of the specimens, with cement voids found in 85% of femora when a centraliser was used and only 20% in the control group. Centraliser B performed worst with cement voids of a larger volume and more frequent occurrence (p=0.002). The macroporosity of the cement mantle was independent of the rate of implantation (p=0.39). The use of femoral stem centralisers is helpful in preventing malposition of the implant but results in increased macroporosity of the cement mantle. This may have implications regarding the longevity of an implant in terms of early loosening and therefore their design and use must always be carefully considered.