Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
Bone & Joint Research
Vol. 6, Issue 11 | Pages 631 - 639
1 Nov 2017
Blyth MJG Anthony I Rowe P Banger MS MacLean A Jones B

Objectives

This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group.

Methods

A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 358 - 364
1 Mar 2017
Torkington MS Davison MJ Wheelwright EF Jenkins PJ Anthony I Lovering AM Blyth M Jones B

Aims

To investigate the bone penetration of intravenous antibiotic prophylaxis with flucloxacillin and gentamicin during hip and knee arthroplasty, and their efficacy against Staphylococcus (S.) aureus and S. epidermidis.

Patients and Methods

Bone samples from the femoral head, neck and acetabulum were collected from 18 patients undergoing total hip arthroplasty (THA) and from the femur and tibia in 21 patients during total knee arthroplasty (TKA). The concentration of both antibiotics in the samples was analysed using high performance liquid chromatography. Penetration was expressed as a percentage of venous blood concentration. The efficacy against common infecting organisms was measured against both the minimum inhibitory concentration 50, and the more stringent epidemiological cutoff value for resistance (ECOFF).


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_4 | Pages 7 - 7
1 May 2015
Gupta S Cafferky D Cowie F Riches P Anthony I Mahendra A
Full Access

Extracorporeal irradiation and re-implantation of a bone segment is a technique employed in bone sarcoma surgery for limb salvage in the setting of reasonable bone stock. There is neither consensus nor rationale given for the dosage of irradiation used in previous studies, with values of up to 300Gy applied. We investigated the influence of extracorporeal irradiation on the elastic and viscoelastic properties of bone. Bone specimens were extracted from mature cattle and subdivided into thirteen groups; twelve groups exposed to increasing levels of irradiation and a control group. The specimens, once irradiated, underwent mechanical testing in saline at 37°C.

Mechanical properties were calculated by experimental means which included Young's Modulus, Poisson's Ratio, Dissipation Factor, Storage Modulus, Loss Modulus and Dynamic Modulus. These were all obtained for comparison of the irradiated specimens to the control group.

We found there to be a statistically significant increase in Poisson's ratio after increasing irradiation doses up to 300Gy were applied. However, there was negligible change in all other mechanical properties of bone that were assessed. Therefore, we conclude that the overall mechanical effect of high levels of extracorporeal irradiation (300Gy) is minute, and can be administered to reduce the risk of malignancy recurrence.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 3 - 3
1 Apr 2015
Gupta S Cafferky D Cowie F Riches P Anthony I Mahendra A
Full Access

Extracorporeal irradiation and re-implantation of a bone segment is a technique employed in bone sarcoma surgery for limb salvage in the setting of reasonable bone stock. There is neither consensus nor rationale given for the dosage of irradiation used in previous studies, with values of up to 300Gy applied. We investigated the influence of extracorporeal irradiation on the elastic and viscoelastic properties of bone. Bone specimens were extracted from mature cattle and subdivided into thirteen groups; twelve groups exposed to increasing levels of irradiation and a control group. The specimens, once irradiated, underwent mechanical testing in saline at 37°C.

Mechanical properties were calculated by experimental means which included Young's Modulus, Storage Modulus and Loss Modulus. These were all obtained for comparison of the irradiated specimens to the control group.

There were non-significant negligible changes in all of the mechanical properties of bone that were assessed with increasing dosage of irradiation. Therefore, we conclude that the overall mechanical effect of high levels of extracorporeal irradiation (300Gy) is minute, and can be administered to reduce the risk of malignancy recurrence.


Introduction:

Mayo 2A Olecranon fractures are traditionally managed with a tension band wire device (TBW) but locking plates may also be used to treat these injuries.

Objectives:

To compare clinical outcomes and treatment cost between TBW and locking plate fixation in Mayo 2A fractures.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 32 - 32
1 Oct 2014
Motesharei A Rowe P Blyth M Jones B MacLean A Anthony I
Full Access

Unicompartmental knee arthroplasty (UKA) has been gaining popularity in recent years due to its perceived benefits over total knee arthroplasty (TKA), such as greater bone preservation, reduced operating-room time, better post-operative range of motion and improved gait. However there have been failures associated with UKA caused by misalignment of the implants that have lead to revisions. To improve the implant alignment a robotic guidance system called the RIO Robotic Arm has been developed by MAKO Surgical Corp (Ft. Lauderdale, FL), which is designed to give improved accuracy compared to traditional UKA using cutting jigs and other manual instrumentation.

The University of Strathclyde in association with Glasgow Royal Infirmary has undertaken the first independent RCT trial of the MAKO system against the Oxford unicompartmental knee arthroplasty – a conventional UKA used in the UK. Motion analysis was used in order to obtain a quantitative assessment of their movement. The results from a total of 51 patients (23 MAKO, 28 Oxford) that underwent a one year post-operative biomechanical assessment were investigated.

Motion analysis showed that during level walking the MAKO group achieved a higher knee excursion during the highest flexion portion of the weight bearing stage of the gait cycle (foot-strike to mid-stance) compared to the Oxford group (18.6° and 15.8° respectively). This difference was statistically significant (p-value = 0.03). Other knee excursion values that were compared were from mid-stance to terminal stance, and overall knee flexion. No statistically significant differences were seen in either of these measurements. A subsequent comparison of both MAKO and Oxford groups with a matched normal cohort (50 patients), demonstrated that there wasn't a statistically significant difference between the MAKO group and the normal knees during mean knee excursion from foot-strike to mid-stance (18.6° and 19.5° respectively, p-value 0.36). However the Oxford group, with a lower knee excursion was found to be significantly different to our normal control group (15.8° and 19.5° respectively, p-value < 0.001).

This suggests that the robotic-assisted knees behaved more similarly to normal gait during this phase of the gait cycle than those of the conventional group. While significant differences in gait were found between the Oxford and MAKO groups, further work is required to determine if this results in improved knee function that is perceptible to the patient.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 8 - 8
1 Apr 2014
Bell S Anthony I Jones B Blyth M
Full Access

The number of primary Total Knee Arthroplasty (TKA) and primary Total Hip Arthroplasty (THA) procedures carried out in England and Wales is increasing annually. The British Orthopaedic Association guidelines for follow up currently differ for patients with TKA and THA. In THA the BOA recommends that Orthopaedic Data Evaluation Panel (ODEP) 10A rated implants should be followed up in the first year, once at seven years and three yearly thereafter. The BOA guidelines for TKA minimum requirement is radiographs at 5 years and each five years thereafter. Few studies have investigated if early follow up affects patient management following total hip and knee arthroplasty

We carried out a retrospective review of all revision procedures carried out in our institution between April 2010 to April 2013. The medical notes and radiographs for each patient were examined to determine the operative indications and patients symptoms. 92 knee revisions and 143 hip revisions were identified. Additionally we retrospectively reviewed the outcome of 300 one year routine arthroplasty follow up appointments.

The mean time of hip revision was 8.5years (range 0 to 27years) and 5.6years (range 0 to 20years) for knee revisions. The commonest cause for revision was aseptic loosening associated with pain in 49 (53%) of knee revision patients and 89 (63%) of hip revisions. Infection accounted for 26 (28%) knee revisions and 16 (12%) hip revisions. Only 1% of hip and knee revisions was carried out in asymptomatic patients with aseptic loosening.

We did not identify any cases were a patients management was altered at the routine arthroplasty review clinic and none were referred on for further surgical treatment. The findings of our study suggest there is no evidence for a routine one year arthroplasty review and revisions were carried out in asymptomatic patients in 1% of patients.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 395 - 398
1 Mar 2014
Bailey O Torkington MS Anthony I Wells J Blyth M Jones B

The aim of this study was to determine if a change in antibiotic prophylaxis for routine hip and knee replacement was associated with an increased risk of acute renal impairment.

We identified 238 patients (128 knees and 110 hips) who had received a single prophylactic dose of 1.5 g cefuroxime before joint replacement. We compared them with prospectively collected data from 254 patients (117 knees and 137 hips) who received a single prophylactic dose of 2 g flucloxacillin and a height- and gender-determined dose of gentamicin. The primary outcome measure was any new renal impairment as graded by clinically validated criteria.

We identified four patients (1.69%) in the cefuroxime group who developed renal impairment. All four had mild impairment and all renal function was normal by the third post-operative day. The incidence of new-onset renal impairment was significantly higher in the flucloxacillin-and-gentamicin group at 9.45% (24 patients) (p < 0.001). Three of these patients remained with acute renal impairment after a week, although the serum creatinine levels in all subsequently returned to normal.

Cite this article: Bone Joint J 2014;96-B:395–8.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 6 - 6
1 Sep 2013
Robinson P Anthony I Kumar S Jones B Stark A Ingram R
Full Access

This study assesses the incidence of noise in ceramic on ceramic (COC) bearings compared to metal on polyethylene (MOP) bearings. Noise after MOP implants has rarely been studied and they never been linked to squeaking.

We have developed a noise characterising hip questionnaire and sent it along with the Oxford Hip Score (OHS) to 1000 patients; 509 respondents, 282 COC and 227 MOP; median age 63.7 (range 45–92), median follow up 2.9 years (range 6–156 months).

47 (17%) of the COC patients reported noise compared to 19 (8%) of the MOP patients (P=0.048). 9 COC and 4 MOP patients reported their hip noise as squeaking. We found the incidence of squeaking in the COC hips to be 3.2% compared to 1.8% in the MOP hips. Overall, 27% patients with noise reported avoiding recreational activities because of it and patient's with noisy hips scored on average 4 points less in the OHS (COC: P=0.04 and MOP: P =0.007).

This is the first study to report squeaking from MOP hip replacements. We therefore believe the squeaking hip phenomenon is not exclusive to hard bearings. Surprisingly, only a small proportion of patients described nose from their as a ‘squeak’. Noisy hip implants may have social implications, and patients should be aware of this. We have shown a relationship between noise and a lower OHS. However, longer follow-up and further study is needed to link noise to a poorly functioning implant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 7 - 7
1 Sep 2013
Lavery J Blyth M Jones B Anthony I
Full Access

To validate the Modified Forgotten Joint Score (MFJS) as a new patient-reported outcome measure (PROM) in hip and knee arthroplasty (THR/TKR) against the UK's gold standard Oxford Hip and Knee Scores (OHS/OKS).

The MFJS is a new assessment tool devised to provide a greater discriminatory power, particularly in well performing patients. It measures an appealing concept; the ability of a patient to forget about their artificial joint in everyday life.

Postal questionnaires were sent out to 400 THR and TKR patients who were 1–2 years post-op. The data collected from the 212 returned questionnaires was analysed in relation to construct and content validity. 77 patients took part in a test-retest repeatability assessment.

The MFJS proved to have an increased discriminatory power in high-performing patients in comparison to the OHS and OKS, highlighted by its more normal frequency of distribution and reduced ceiling effects. 30.8% of patients (n=131) achieved excellent OHS/OKS scores of 42–48 this compared to just 7.69% of patients who achieved a proportionately equivalent MFJS score of 87.5–100. The MFJS proved to have an increased test-retest repeatability based upon its intra-class correlation coefficient of 0.97 compared to the Oxford's 0.85.

The MFJS provides a more sensitive tool in the assessment of well performing hip and knee arthroplasties in comparison to the OHS/OKS. The MFJS tests the concept of awareness of a prosthetic joint, rather than pain and function and therefore should be used as adjunct to the OKS/OHS.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 51 - 51
1 Aug 2013
Robinson P Anthony I Stark A Jones B Ingram R
Full Access

The link between squeaking and ceramic on ceramic (CoC) bearings has been widely reported in orthopaedic literature and is described as a hard bearing phenomenon. We aim to look at the incidence of noise in CoC bearings compared to Metal on Polyethylene (MoP) bearing, which have yet to be linked to squeaking.

We developed a noise characterizing hip questionnaire and sent that along with the Oxford Hip Score (OHS) to 1000 patients; 3:2 ratio of CoC to MoP. 282 CoC patients and 227 MoP patients returned the questions: 509 patients in total. Our patient database provided details on femoral head size and the acetabular inclination angle, for each respondent

47 (17%) of the CoC hip patients reported noise compared to 19 (8%) of the MoP hip patients (P=0.054). 9 CoC patients and 4 MoP patients reported squeaking, while clicking was the most frequent answer in both groups. 27% patients with noise reported avoiding recreational activities because of it. Patient's with noisy hips scored on average, 5 points worse in the OHS (CoC: P = 0.04 and MoP: P = 0.007) and were on average 5 years younger (CoC: P<0.001 and MoP: P=0.007). No correlation was found between noisy hips and femoral head size or inclination angle.

The squeaking hip phenomenon is not exclusive to hard bearing THA. Noise from patient's hips may have social implications and this should be highlighted when consenting a patient for either of these hip procedures. In both implants, we showed there to be a correlation between noise production and a lower OHS. However, longer follow up studies are needed to link noise to a poorly functioning implant


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 14 - 14
1 Aug 2013
Joseph J Anthony I Jones B Blyth M
Full Access

The purpose of this study was to evaluate the effect of body mass index (BMI) on patients undergoing primary total knee arthroplasty for osteoarthritis. Data was collected on 664 patients at 4 centres all of whom received a Depuy PFC Sigma prosthesis. Data collected included patient demographics, Oxford Knee Score (OKS), American Knee Society Score, SF-12, complications of surgery and the need for revision.

14% of patients had a BMI<25, 35% were overweight (BMI-25–30), 32% suffered from Grade 1 obesity (BMI-30–35) and 19% had grade 2 obesity (BMI>35). Obese patients were more likely to be female, have a higher ASA grade, present at a younger age and do sedentary work or no work at all. Pre-operative Oxford knee score was significantly worse in the BMI>35 group (p<0.001).

After surgery there was a significant improvement in functional outcome measures at 5 years post-operatively with all BMI groups improved by an average of 18 or 19 points in the OKS. However because those patients with high BMI have poorer pre-operative Oxford scores their post-operative scores were lower compared to patients with a normal BMI. Similar findings were noted with range of motion of the knee joint.

Overall complication rates were found to be significantly higher in obese patients and both revision surgery and deep infection rates increased stepwise with increasing BMI levels.

Deep Infection rates were as follows: BMI<25 0%, BMI-25–30 1.3%, BMI-30–35 1.4%, BMI-35–40 3.2% and BMI>40 6.1%.

Revision rates were as follows: BMI<25 0%, BMI-25–30 0.9%, BMI-30–35 0.9%, BMI-35–40 3.2% and BMI>40 6.1%.

Although obese patients with knee osteoarthritis do benefit from joint arthroplasty, they suffer from an increased rate of complications and need for revision surgery.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 47 - 47
1 Aug 2013
Siddiqui M Bidaye A Baird E Jones B Stark A Abu-Rajab R Anthony I Ingram R
Full Access

We compared the postoperative wound discharge rates and 3 months clinical results of three types of wound closure and dressing – 2-octylcyanoacrylate with Opstie (G+O), 2-octylcyanoacrylate with Tegaderm (G+T), and Opsite without 2-octylcyanoacrylate (O) in patients having primary total hip arthroplasty.

We randomised 141 patients scheduled for primary total hip arthroplasty into 3 arms of this study- G+O, G+T, or O. The extent of wound discharge was recorded on a diagrammatic representation of the dressing in situ on paper and graded each day. Dressings were left in-situ provided the extent of wound discharge allowed for this. The patient was clinically reviewed at 3 months to assess their scar length, cosmesis, scar discomfort, and evidence of superficial or deep wound sepsis.

A greater number of patients dressings remained dry on day 1 postoperatively in the two groups with 2-octylcyanoacrylate compared to the no glue group p=0.001. G+T group had a significantly lower proportion of patients with increased leakage of wounds on 2nd postoperative day p=0.044. At 3 months review, there was no statistical difference in the Hollander score or scar discomfort.

In patients who have had primary total hip arthroplasty, usage of 2-octylcyanoacrylate for wound closure along with Tegaderm dressing reduces wound discharge. The same effect is not noted in glue with Opsite group. Whilst dressing changes required in the non-glue group compared from the two glue groups did not reach statistical significance, this may have clinical relevance for patients and nursing staff. No effect on postoperative length of stay, or wound complications was noted.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 11 - 11
1 Aug 2013
Harding T Dolan R Hannah S Anthony I Halifax R Brooksbank A
Full Access

Aims

Isolated greater tuberosity fractures make up 17–21% of proximal humeral fractures, 30% are associated with shoulder dislocation. Conservative management of minimally displaced fractures (<5 mm) is recommended. There are few guides to which and how many fractures displace over time.

Methods

A retrospective analysis of isolated greater tuberosity fractures presenting to a shoulder fracture clinic over 1 year was performed. Patients were identified from shoulder fracture clinic lists and a bluespier database. Radiological fracture displacement was measured from the edge of the defect in the humeral head to the closest edge of the greater tuberosity. All measurements were performed by three oberservers on two occasions. Data was analysed to study the relationship between initial displacement and fracture stability and between concurrent dislocation and fracture stability. Inter-observer analysis was performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 39 - 39
1 Aug 2013
Lavery J Anthony I Blyth M Jones B
Full Access

To validate the Modified Forgotten Joint Score (MFJS) as a new patient-reported outcome measure (PROM) in hip and knee arthroplasty against the UK's gold standard Oxford Hip and Knee Scores (OHS/OKS).

The original Forgotten Joint Score was created by Behrend et al to assess post-op hip/knee arthroplasty patients. It is a new assessment tool devised to provide a greater discriminatory power, particularly in the well performing patients. It measures an appealing concept; the ability of a patient to forget about their artificial joint in everyday life. The original FJS was a 12-item questionnaire, which we have modified to 10-items to improve reliability and missing data.

Postal questionnaires were sent out to 400 total hip/knee replacement (THR/TKR) patients who were 1–2 years post-op, along with the OHS/OKS and a visual pain analog score. The data collected from the 212 returned questionnaires (53% return rate) was analysed in relation to construct and content validity. A sub-cohort of 77 patients took part in a test-retest repeatability study to assess reliability of the MFJS.

The MFJS proved to have an increased discriminatory power in high-performing patients in comparison to the OHS and OKS, highlighted by its more normal frequency of distribution and reduced ceiling effects in the MFJS. 30.8% of patients (n=131) scored 42–48 (equivalent to 87.5–100 in the MFJS) or more in the OKS compared to just 7.69% in the MFJS TKR patients. The MFJS proved to have an increased test-retest repeatability based upon its intra-class correlation coefficient of 0.968 compared to the Oxford's 0.845.

The MFJS provides a more sensitive tool in the assessment of well performing hip and knee arthroplasties in comparison to the OHS/OKS. The MFJS tests the concept of awareness of a prosthetic joint, rather than pain and function and therefore should be used as adjunct to the OKS/OHS.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 17 - 17
1 Aug 2013
Boyle J Anthony I Jones B MacLean A Wheelwright E Blyth M
Full Access

A retrospective analysis was carried out to determine the influence of pre-existing spinal pathology on the outcome of Total Knee Replacement surgery. Data was collected from 345 patients who had undergone Total Knee Replacement, at four centres in the UK, between 2000 and 2007. Oxford Knee Scores (OKS), American Knee Society Scores (AKSS) and SF-12 questionnaires were recorded prospectively. Data was collected pre-operatively and then post-operatively at 3 months, 1 year and 2 years. Patients were divided into those with (n=40) and without a history of low back pain (n=305). In addition to determining the influence of low back pain on outcome after Total Knee Replacement we also examined the influence of concomitant hip and ankle pathology in the same cohort of patients.

OKS scores were significantly worse for patients with symptomatic low back pain at 3 (p=0.05), 12 (p=0.009) and 24 months (p=0.039) following surgery. SF-12 physical scores followed a comparable pattern with significance demonstrated at 3 (p=0.038), 12 (p=0.0002) and 24 months (p=0.016). AKSS followed a similar pattern, but significance was only reached at 1 year (p=0.013). The mental component of the SF-12 measure demonstrated a significant improvement in patients' mental health post-operatively for patients with no history of low back pain. In contrast patients with low back pain showed no improvement in mental health scores post-operatively.

In contrast to low back pain, hip and ankle pathology had no statistically significant detrimental effect on the outcome of Total Knee Replacement surgery.

This study demonstrates that low back pain significantly affects the functional outcome after Total Knee Replacement surgery and that patients with low back pain show no improvement in mental health post-operatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 11 - 11
1 May 2013
Donaldson D Torkington M Anthony I Blyth M Jones B
Full Access

The longitudinal midline and medial-parapatellar incision are commonly used in Total Knee Arthroplasty (TKA). Medial-parapatellar incision n offers a smaller wound, avoids creation of thin skin flaps and easier exposure in obese patients. This incision creates a lateral skin flap which may be subject to poor blood supply and delayed wound healing.

We undertook a Randomised Controlled Trial (n=20) comparing midline and medial-parapatellar incisions. Cutaneous blood-flow was measured using a Doppler Imager. Interstitial fluid measurements for lactate, pyruvate, lactate/pyruvate ratio and glucose were obtained from subcutaneous microdialysis catheters. Wound cosmesis was graded and skin sensation tested.

Immediately post-op there was no significant difference in subcutaneous blood flow, but by day 3 patients with medial-parapatellar incisions showed greater bloodflow than midline incisions, particularly on the medial side (387 vs 278units p=0.148). At both day 1 and 3 post-op the lateral flap of the medial parapatellar incision showed decreased blood flow compared to the medial side, though these failed to reach significance. In contrast the midline incision showed no discernable difference in blood flow between the medial and lateral flaps. Concentrations of subcutaneous glucose increased from 4 hours post-op in the midline group, returning to baseline by 24hours. In contrast, the parapatellar group remained at base line throughout. Lactate concentrations increased over time in both groups peaking at 12hours post-op. No difference was noted between incision types with regard to wound cosmesis.

We conclude that the use of a medial-parapatellar incision results in only minimal biochemical changes, which are unlikely to alter wound healing. Medial-parapatellar incision is therefore a safe alternative to a midline incision and can be utilised in appropriate complex cases to aid surgical exposure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 164 - 164
1 Jan 2013
Bailey O Torkinton M Anthony I Wells J Jones B
Full Access

Introduction

Acute renal dysfunction (ARD) following orthopaedic surgery is known to increase morbidity, mortality, and length of hospital stay. The aim of this study was to compare the incidence of new acute post-operative renal dysfunction between two cohorts of elective orthopaedic surgical patients receiving either cefuroxime or a combination of gentamicin and flucloxacillin as prophylactic antibiotic regimes. The study was initiated following a change in antibiotic prophylaxis within our unit from cefuroxime to gentamicin and flucloxacillin.

Method

Using a standardised data collection tool we retrospectively reviewed medical records of 238 patients who had received 1.5g of cefuroxime (TKR: n = 128; THR: n=110). This data was compared to prospectively collected data from 254 patients (TKR=117 THR=137) who had received Flucloxacillin 2g and Gentamicin (with the dose based on height). Primary outcome measure for the study was the RIFLE criteria which grades renal impairment: 0-Nil, 1-Risk, 2-Injury, 3-Renal failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 32 - 32
1 Jan 2013
Boyle J Anthony I Jones B Wheelwright E Blyth M
Full Access

A retrospective analysis was carried out to determine the influence of pre-existing spinal pathology on the outcome of Total Knee Replacement surgery. Data was collected from 345 patients who had undergone Total Knee Replacement, at four centres in the UK, between 2000 and 2007. Oxford Knee Scores (OKS), American Knee Society Scores (AKSS) and SF-12 questionnaires were recorded prospectively. Data was collected pre-operatively and then post-operatively at 3 months, 1 year and 2 years. Patients were divided into those with (n=40) and without a history of low back pain (n=305). In addition to determining the influence of low back pain on outcome after Total Knee Replacement we also examined the influence of concomitant hip and ankle pathology in the same cohort of patients.

OKS scores were significantly worse for patients with symptomatic low back pain at 3 (p=0.05), 12 (p=0.009) and 24 months (p=0.039) following surgery. SF-12 physical scores followed a comparable pattern with significance demonstrated at 3 (p=0.038), 12 (p=0.0002) and 24 months (p=0.016). AKSS followed a similar pattern, but significance was only reached at 1 year (p=0.013). The mental component of the SF-12 measure demonstrated a significant improvement in patients' mental health post-operatively for patients with no history of low back pain. In contrast patients with low back pain showed no improvement in mental health scores post-operatively.

In contrast to low back pain, hip and ankle pathology had no statistically significant detrimental effect on the outcome of Total Knee Replacement surgery.

This study demonstrates that low back pain significantly affects the functional outcome after Total Knee Replacement surgery and that patients with low back pain show no improvement in mental health post-operatively.