Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 44 - 44
1 Apr 2022
Chowdhury J Rodham P Asmar S Battaloglu E Foster P
Full Access

Introduction

Numerous fixation modalities can be used for various indications, including deformity correction, trauma, infection, and non-union. The Modular Rail System (MRS) is a well-tolerated apparatus that is a viable option for patients who do not want a circular frame or for whom internal fixation is not appropriate due to poor soft tissues/co-morbidities. This case series evaluates the outcomes of the use of the MRS in our centre.

Materials and Methods

Cases were identified from a prospectively gathered database. Data were collected including indication for treatment, frame duration, complications and treatment outcome. Eighteen eligible cases were identified (mean age 26, range 8–71). The MRS was sited in the femur in 14 cases, the tibia in three and the fibula in one. In nine cases, a circular frame was sited on the tibia below a femoral MRS. Frames were removed at an average of 20 weeks (range 7–31).