Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 56 - 56
22 Nov 2024
Hanssen J Gademan M Wouthuyzen-Bakker M Davis JS Dewar D Manning L Campbell D van Prehn J Miller A van der Wal R van der Linden E Cortes-Penfield N Soriano A De Boer MG Scheper H
Full Access

Aim

Suppressive antimicrobial therapy (SAT) is used worldwide for patients with a prosthetic joint infection (PJI but clear definitions or guidelines regarding the indications, antimicrobial strategy or treatment duration are currently lacking in the literature. The aim of this study was to identify the global differences in the clinical practice of SAT for PJI.

Method

An online survey was designed to investigate the current opinion on indication and treatment goals, preferred antimicrobial drugs, dosing and treatment duration and follow-up of patients with PJI on suppression. The survey was distributed using e-mail lists of several international bone and joint infection societies and study groups. Recipients were asked to share the survey with colleagues who were not a member of one of the societies but who were involved in PJI care.


Bone & Joint Research
Vol. 13, Issue 9 | Pages 507 - 512
18 Sep 2024
Farrow L Meek D Leontidis G Campbell M Harrison E Anderson L

Despite the vast quantities of published artificial intelligence (AI) algorithms that target trauma and orthopaedic applications, very few progress to inform clinical practice. One key reason for this is the lack of a clear pathway from development to deployment. In order to assist with this process, we have developed the Clinical Practice Integration of Artificial Intelligence (CPI-AI) framework – a five-stage approach to the clinical practice adoption of AI in the setting of trauma and orthopaedics, based on the IDEAL principles (https://www.ideal-collaboration.net/). Adherence to the framework would provide a robust evidence-based mechanism for developing trust in AI applications, where the underlying algorithms are unlikely to be fully understood by clinical teams.

Cite this article: Bone Joint Res 2024;13(9):507–512.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 30 - 30
1 Jun 2023
Tissingh E Goodier D Wright J Timms A Campbell M Crook G Calder P
Full Access

Introduction

The FitBone lengthening nail (Orthofix UK) is an intramedullary device licensed for the lengthening of long bones in adults in the UK. It contains a motor powered by electricity transmitted via an induction coil placed underneath the skin. It was developed in Germany two decades ago but uptake in the UK has only started more recently. The aim of this study was to review the first cohort of FitBone lengthening nails in a unit with significant experience of other lengthening nails (including PRECICE and Stryde).

Materials & Methods

Demographic, clinical and radiological data was prospectively collected on all FitBone cases starting in February 2022. Accuracy of lengthening rate, patient satisfaction and implant issues were all considered. Complications and learning points were recorded and discussed by the multidisciplinary team involved in the patients care.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 102 - 102
23 Feb 2023
Campbell T Hill L Wong H Dow D Stevenson O Tay M Munro JT Young S Monk AP
Full Access

Contemporary indications for unicompartmental knee replacement (UKR) include bone on bone radiographic changes in the medial compartment with relatively preserved lateral and patellofemoral compartments. The role of MRI in identifying candidates for UKR is commonplace. The aim of this study was to assess the relationship between radiographic and MRI pre-operative grade and outcome following UKR.

A retrospective analysis of medial UKR patients from 2017 to 2021. Inclusion criteria were medial UKR for osteoarthritis with pre-operative and post-operative Oxford Knee Scores (OKS), pre-operative radiographs and MRI.

89 patients were included. Whilst all patients had grade 4 ICRS scores on MRI, 36/89 patients had grade 3 KL radiographic scores in the medial compartment, 50/89 had grade 4 KL scores on the medial compartment. Grade 3 KL with grade 4 IRCS medial compartment patients had a mean OKS change of 17.22 (Sd 9.190) meanwhile Grade 4 KL had a mean change of 17.54 (SD 9.001), with no statistical difference in the OKS change score following UKR between these two groups (p=0.873). Medial bone oedema was present in all but one patient. Whilst lateral compartment MRI ICRS scores ranged from 1 to 4 there was no association with MRI score of the lateral compartment and subsequent change in oxford score (P value 0.458). Patellofemoral Compartment (PFC) MRI ICRS ranged from 0 to 4. There was no association between PFC ICRS score and subsequent change in oxford knee score (P value .276)

Radiographs may under report severity of some medial sided knee osteoarthritis. We conclude that in patients with grade 3 KL score that would normally not be considered for UKR, pre-operative MRI might identify grade 4 ICRS scores and this subset of patients have equivalent outcomes to patients with radiographic Grade 4 KL medial compartment osteoarthritis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 48 - 48
10 Feb 2023
Wall C de Steiger R Mulford J Lewis P Campbell D
Full Access

There is growing interest in the peri-operative management of patients with indications for hip and knee arthroplasty in the setting of modifiable risk factors such as morbid obesity, type 2 diabetes mellitus, and smoking. A recent survey of the American Association of Hip and Knee Surgeons (AAHKS) found that 95% of respondents address modifiable risk factors prior to surgery. The aim of this study was to poll Australian arthroplasty surgeons regarding their approach to patients with modifiable risk factors.

The survey tool used in the AAHKS study was adapted for use in the Australian context and distributed to the membership of the Arthroplasty Society of Australia via Survey Monkey.

Seventy-seven survey responses were received, representing a response rate of 64%. The majority of respondents were experienced, high volume arthroplasty surgeons. Overall, 91% of respondents restricted access to arthroplasty for patients with modifiable risk factors. Seventy-two percent of surgeons restricted access for excessive body mass index, 85% for poor diabetic control, and 46% for smoking. Most respondents made decisions based on personal experience or literature review rather than hospital or departmental pressures.

Despite differences in healthcare systems, our findings were similar to those of the AAHKS survey, although their responses were more restrictive in all domains. Differences were noted in responses concerning financial considerations for potentially underprivileged populations. The survey is currently being administered by arthroplasty societies in six other countries, allowing comparison of orthopaedic practice across different healthcare systems around the world.

In conclusion, over 90% of Australian arthroplasty surgeons who responded to the survey address modifiable risk factors prior to surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 101 - 101
10 Feb 2023
Tan W Yu S Gill T Campbell D Umapathysivam K Smitham P
Full Access

The progressive painful and disabling predicament of patients with severe osteoarthritis awaiting a total hip or knee arthroplasty (THA/TKA) results in a decline in muscle mass, strength and function also known as Sarcopenia.

We conducted a cross-sectional, prospective study of patients on the waiting-list for a THA/TKA in the South Australian public healthcare system and compared the findings to healthy participants and patients newly referred from their general practitioners. Participants with a history of joint replacements, pacemakers and cancers were excluded from this study. Outcomes of this study included (i) sarcopenia screening (SARC-F ≥4); (ii) sarcopenia, defined as low muscle strength (hand grip strength M<27kg; F<16kg), low muscle quality (skeletal muscle index M<27%, F<22.1%) and low physical performance (short physical performance battery ≤8). Additional outcomes include descriptions of the recruitment feasibility, randomisation and suitability of the assessment tools.

29 healthy controls were recruited; following screening, 83% (24/29) met the inclusion criteria and 75% (18/24) were assessed. 42 newly referred patients were recruited; following screening, 67% (30/45) met the inclusion criteria and 63% (19/30) were assessed. 68 waiting list patients were recruited; following recruitment, 24% (16/68) met the inclusion criteria and 75% (12/16) were assessed. Preliminary data shows increasing waiting time is associated with higher SARC-F scores, lower hand grip strength and lower muscle quality.

As a pilot study, preliminary data demonstrate that: (1) study subjects’ willingness to participate will enable a larger study to be conducted to establish the prevalence of sarcopenia and the diagnostic cut-off points for this patient group. (2) SARC-F is a suitable tool to screen for sarcopenia. (3) There is a positive correlation between waiting time for a THA/TKA and sarcopenia.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 55 - 55
1 Dec 2022
Nowak L Campbell D Schemitsch EH
Full Access

To describe the longitudinal trends in patients with obesity and Metabolic Syndrome (MetS) undergoing TKA and the associated impact on complications and lengths of hospital stay.

We identified patients who underwent primary TKA between 2006 – 2017 within the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database. We recorded patient demographics, length of stay (LOS), and 30-day major and minor complications. We labelled those with an obese Body Mass Index (BMI ≥ 30), hypertension, and diabetes as having MetS. We evaluated mean BMI, LOS, and 30-day complication rates in all patients, obese patients, and those with MetS from 2006-2017. We used multivariable regression to evaluate the trends in BMI, complications, and LOS over time in all patients and those with MetS, and the effect of BMI and MetS on complication rates and LOS, stratified by year.

270,846 patients underwent primary TKA at hospitals participating in the NSQIP database. 63.71% of patients were obese (n = 172,333), 15.21% were morbidly obese (n = 41,130), and 12.37% met criteria for MetS (n = 33,470). Mean BMI in TKA patients increased at a rate of 0.03 per year (0.02-0.05; p < 0 .0001). Despite this, the rate of adverse events in obese patients decreased: major complications by an odds ratio (OR) of 0.94 (0.93-0.96; p < 0 .0001) and minor complications by 0.94 (0.93-0.95; p < 0 .001). LOS also decreased over time at an average rate of −0.058 days per year (-0.059 to −0.057; p < 0 .0001). The proportion of patients with MetS did not increase, however similar improvements in major complications (OR 0.94 [0.91-0.97] p < 0 .0001), minor complications (OR 0.97 [0.94-1.00]; p < 0 .0330), and LOS (mean −0.055 [-0.056 to −0.054] p < 0 .0001) were found. In morbidly obese patients (BMI ≥ 40), there was a decreased proportion per year (OR 0.989 [0.98-0.994] p < 0 .0001). Factors specifically associated with major complications in obese patients included COPD (OR 1.75 [1.55-2.00] p < 0.0001) and diabetes (OR 1.10 [1.02-1.1] p = 0.017). Hypertension (OR 1.12 [1.03-1.21] p = 0.0079) was associated with minor complications. Similarly, in patients with MetS, major complications were associated with COPD (OR 1.72 [1.35-2.18] p < 0.0001). Neuraxial anesthesia was associated with a lower risk for major complications in the obese cohort (OR 0.87 [0.81-0.92] p < 0.0001). BMI ≥ 40 was associated with a greater risk for minor complications (OR 1.37 [1.26-1.50] p < 0.0001), major complications (1.11 [1.02-1.21] p = 0.015), and increased LOS (+0.08 days [0.07-0.09] p < 0.0001).

Mean BMI in patients undergoing primary TKA increased from 2006 - 2017. MetS comorbidities such as diabetes and hypertension elevated the risk for complications in obese patients. COPD contributed to higher rates of major complications. The obesity-specific risk reduction with spinal anesthesia suggests an improved post-anesthetic clinical course in obese patients with pre-existing pulmonary pathology. Encouragingly, the overall rates of complications and LOS in patients with obesity and MetS exhibited a longitudinal decline. This finding may be related to the decreased proportion of patients with BMI ≥ 40 treated over the same period, possibly the result of quality improvement initiatives aimed at delaying high-risk surgery in morbidly obese patients until healthy weight loss is achieved. These findings may also reflect increased awareness and improved management of these patients and their elevated risk profiles.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 21 - 21
1 Mar 2021
Gottschalk M Dawes A Farley K Nazzal E Campbell C Spencer C Daly C Wagner E
Full Access

Perioperative glucocorticoids have been used as a successful non-opioid analgesic adjunct for various orthopaedic procedures. Here we describe an ongoing randomized control trial assessing the efficacy of a post-operative methylprednisolone taper course on immediate post-operative pain and function following surgical distal radius fixation. We hypothesize that a post-operative methylprednisolone taper course following distal radius fracture fixation will lead to improved patient pain and function.

This study is a randomized control trial (NCT03661645) of a group of patients treated surgically for distal radius fractures. Patients were randomly assigned at the time of surgery to receive intraoperative dexamethasone only or intraoperative dexamethasone followed by a 6-day oral methylprednisolone (Medrol) taper course. All patients received the same standardized perioperative pain management protocol. A pain journal was used to record visual analog pain scores (VAS-pain), VAS-nausea, and number of opioid tablets consumed during the first 7 post-operative days (POD). Patients were seen at 2-weeks, 6-weeks, and 12-weeks post-operatively for clinical evaluation and collection of patient reported outcomes (Disabilities of the Arm, Shoulder and Hand Score [qDASH]). Differences in categorical variables were assessed with χ2 or Fischer's exact tests. T-tests or Mann-Whitney-U tests were used to compare continuous data.

Forty-three patients were enrolled from October 2018 to October 2019. 20 patients have been assigned to the control group and 23 patients have been assigned to the treatment group. There were no differences in age (p=0.7259), Body Mass Index (p=0.361), race (p=0.5605), smoking status (p=0.0844), or pre-operative narcotic use (p=0.2276) between cohorts. 83.7% (n=36) of patients were female and the median age was 56.9 years. No differences were seen in pre-operative qDASH (p=0.2359) or pre-operative PRWE (p=0.2329) between groups. In the 7 days following surgery, patients in the control group took an average of 16.3 (±12.02) opioid tablets, while those in the treatment group took an average of 8.71 (±7.61) tablets (p=0.0270). We see that significant difference in Opioid consumption is formed at postoperative day two between the two groups with patients in the control group taking. Patient pain scores decreased uniformly in both groups to post-operative day 7. Patient pain was not statistically from POD0 to POD2 (p=0.0662 to 0.2923). However, from POD4 to POD7 patients receiving the methylprednisolone taper course reported decreased pain (p=0.0021 to 0.0497). There was no difference in qDASH score improvement at 6 or 12 weeks. Additionally, no differences were seen for wrist motion improvement at 6 or 12 weeks.

A methylprednisolone taper course shows promise in reducing acute pain in the immediate post-operative period following distal radius fixation. Furthermore, although no statistically significant reductions in post-operative opioid utilization were noted, current trends may become statistically significant as the study continues. No improvements were seen in wrist motion or qDASH and continued enrollment of patients in this clinical trial will further elucidate the role of methylprednisolone for these outcomes.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 70 - 70
1 Jul 2020
Queen R Schmitt D Campbell J
Full Access

Power production in the terminal stance phase is essential for propelling the body forward during walking and is generated primarily by ankle plantarflexion. Osteoarthritis (OA) of the ankle restricts joint range of motion and is expected to reduce power production at that ankle. This loss of power may be compensated for by unaffected joints on both the ipsilateral and contralateral limbs resulting in overloading of the asymptomatic joints. Total ankle arthroplasty (TAA) has been shown to reduce pain and has the potential to restore range of motion and therefore increase ankle joint power, which could reduce overloading of the unaffected joints and increase walking speed. The purpose of this study was to test the hypothesis that ankle OA causes a loss of power in the affected ankle, compensatory power changes in unaffected lower limb joints, and that TAA will increase ankle power in the repaired ankle and reduce compensatory changes in other joints.

One hundred and eighty-three patients (86 men, 97 women with average ages 64.1 and 62.4 years respectively) requiring surgical intervention for ankle OA were prospectively enrolled. Implant selection of either a fixed (INBONE or Salto Talaris) or mobile (STAR) bearing implant was based on surgeon preference. Three-dimensional kinematics and kinetics were collected prior to surgery and one year post-operatively during self-selected speed level walking using an eight-camera motion capture system and a series of force platforms. Subject walking speed and lower extremity joint power during the last third of stance at the ankle, knee, and hip were calculated bilaterally and compared before and after surgical intervention across the entire group and by implant type (fixed vs. mobile), and gender using a series of ANOVAs (JMP SAS, Cary, NC), with statistical significance defined as p < 0 .05.

There were no gender differences in age, walking speed, or joint power. All patients increased walking as a result of surgery (0.87 m/s±0.26 prior to surgery and 1.13 m/s±0.24 after surgery, p < 0 .001) and increased total limb power. Normalized to total power (which accounts for changes in speed and distribution of power production across joints), prior to surgery the affected ankle contributed 19%±10% of total power while the unaffected ankle contributed 42%±12% (P < 0 .001). After surgery, the affected ankle increased to 25%±9% of total power and the unaffected ankle decreased to 38%±9% of total (P < 0.001). Other joints showed no significant power changes following surgery. Fixed bearing implants provide greater surgical ankle power improvement (61% versus 29% increase, p < 0 .002). Much of that change was due to the fact that those that received fixed-bearing implants had significantly lower walking speed and power before surgery.

Ankle OA reduced ankle power production, which was partially compensated for by the unaffected ankle. TAA increases walking speed and power at the affected ankle while lowering power production on the unaffected side. The modifications in power production could lead to increased physical activity and reduced overloading of asymptomatic joints.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 37 - 37
1 Jul 2020
Mann S Tohidi M Harrison MM Campbell A Lajkosz K VanDenKerkhof E
Full Access

The purpose of this population-based study was to determine the association between morbid obesity and 10-year mortality and complications in patients undergoing primary THA.

A cohort study of 22,251 patients, aged 45–74 years old, treated with primary THA between 2002 and 2007 for osteoarthritis, was conducted using Ontario administrative healthcare databases. Patients were followed for 10 years. Risk ratios (RRs) of mortality, reoperation, revision, and dislocation in patients with body mass index (BMI) > 45 kg/m2(morbidly obese patients) compared with BMI ≤45 kg/m2 (non-morbidly obese) were estimated.

3.3% of the cohort (726) was morbidly obese. Morbidly obese patients were younger (mean age 60.6 vs. 63.3, P-value < 0 .001) and more likely to be female (63.9% vs. 52.2%, P-value < 0 .001), compared with non-morbidly obese patients. Morbid obesity was associated with higher 10-year risk of death (RR 1.38, 95% CI 1.18, 1.62). Risks of revision (RR 1.43, 95% CI 0.96, 2.13) and dislocation (RR 2.38, 95% CI 1.38, 4.10) were higher in morbidly obese men, compared with non-morbidly obese men, there were no associations between obesity and revision or dislocation in women. Risk of reoperation was higher in morbidly obese women, compared to non-morbidly obese women (RR 1.60, 95% CI 1.05, 2.40), there was no association between obesity and reoperation in men.

Morbidly obese patients undergoing primary THA are at higher risks of long-term mortality and complications. There were differences in complication risk by sex. Results should inform evidence-based perioperative counseling of morbidly obese patients considering THA.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 12 - 12
1 Apr 2019
Campbell P Kung MS Park SH
Full Access

Background

Distal femoral replacements (DFR) are used in children for limb-salvage procedures after bone tumor surgery. These are typically modular devices involving a hinged knee axle that has peripheral metal-on-polyethylene (MoP) and central metal-on-metal (M-M) articulations. While modular connections and M-M surfaces in hip devices have been extensively studied, little is known about long-term wear or corrosion mechanisms of DFRs. Retrieved axles were examined to identify common features and patterns of surface damage, wear and corrosion.

Methods

The cobalt chromium alloy axle components from 13 retrieved DFRs were cleaned and examined by eye and with a stereo microscope up to 1000× magnification. Each axle was marked into 6 zones for visual inspection: the proximal and distal views, and the middle (M-M) and 2 peripheral (MoP) zones. The approximate percentage of the following features were recorded per zone: polishing, abrasion or scratching, gouges or detectable wear, impingement wear (i.e. from non- intentional articulation), discoloration and pitting.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2019
Wilson C Critchely O Callary S Campbell D
Full Access

Introduction & aims

The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration.

Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail hydroxyapatite-coated cementless stem at 10 years using RSA.

Method

A prospective cohort of 30 patients undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration behaviour of a cementless stem. Tantalum markers were attached to the stem and placed in the bone intraoperatively, allowing for RSA measurements to be taken in vivo. Previous 5-year results have been presented.

A total of 14 patients (total 15 hips, one bilateral) with mean age 82 years (range, 69–92 years) underwent repeat long-term RSA radiographs at minimum 10 years post op. The mean time to follow up was 13.9 years (range, 13.3–14.4 years). The RSA radiographs were analysed to assess for implant rotation and translation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 92 - 92
1 Apr 2018
Messer P Baetz J Lampe F Pueschel K Klein A Morlock M Campbell G
Full Access

INTRODUCTION

The restoration of the anatomical hip rotation center (HRC) has a major influence on the longevity of hip prostheses. Deviations from the HRC of the anatomical joint after total hip arthroplasty (THA) can lead to increased hip joint forces, early wear or loosening of the implant. The contact conditions of acetabular press-fit cups after implantation, including the degree of press-fit, the existence of a polar gap and cup orientation, may affect the HRC restoration, and therefore implant stability. The aim of this study was to determine the influence of acetabular press-fit, polar gap and cup orientation on HRC restoration during THA.

METHODS

THAs were performed by an experienced orthopaedic surgeon in full cadaveric models simulating real patient surgery (n=7). Acetabular cups with a Porocoat™ (n=3) and Gription™ surface coating (n=4) were implanted (DePuy Synthes, Leeds, UK). Computed tomography (CT) scans prior to surgery, as well as after reaming and implantation of press-fit cups were used to calculate the HRC displacement. After aligning the pelves in the anterior pelvic plane, 3D reconstruction of the HRC at each stage was performed by fitting spheres to the femoral head, the reamed cavity and the inserted cup. 3D surface models of the cups were generated using a laser scanner and were registered to the CT images. The effective press-fit was calculated using the diameters of spheres, fitted to the cavity prior to cup insertion and to the outer cup coating. The polar gap was defined as the difference between the outer cup surface and the subchondral bone at the cup pole. Anteversion and abduction angles were calculated as difference between the cup planes and the sagittal and transverse plane, respectively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 4 - 4
1 Apr 2018
Baetz J Messer P Lampe F Pueschel K Klein A Morlock M Campbell G
Full Access

INTRODUCTION

Loosening is a major cause for revision in uncemented hip prostheses due to insufficient primary stability. Primary stability after surgery is achieved through press-fit in an undersized cavity. Cavity preparation is performed either by extraction (removing bone) or compaction (crushing bone) broaching. Densification of trabecular bone has been shown to enhance primary stability in human femora; however, the effect of clinically used compaction and extraction broaches on human bone with varying bone mineral density (BMD) has not yet been quantified. The purpose of this study was to determine the influence of the broach design and BMD on the level of densification at the bone-cavity interface, stem seating, the bone-implant contact area and the press-fit achieved.

METHODS

Paired human femora (m/f=11/12, age=60±18 y) were scanned with quantitative computed tomography (QCT, Philips Brilliance 16) before broaching, with the final broach, after its removal and after stem implantation. Compaction broaching (n=4) was compared in an in situ (cadaver) study against extraction broaching with blunt tooth types (n=3); in an ex situ (excised femora) study, compaction broaching was compared against extraction broaching with sharp tooth types (n=8 each). QCT data were resampled to voxel sizes of 1×1×1 mm (in situ) and 0.5×0.5×1 mm (ex situ). Mean trabecular BMD of the proximal femur was determined. The cavity volumes were segmented in the post-broach images (threshold: −250 mgHA/cm3, Avizo 9.2) and a volume of interest (VOI) of one-voxel thickness was added around the cavity to capture the interfacial bone. VOIs were transferred to the pre-broach image and bone densification was calculated within each VOI as the increase from pre- to post-broach image (MATLAB). Detailed surface data sets of broaches and stems were collected with a 3D laser-scanner (Creaform Handyscan 700) and aligned with the segmented components in the CT scans (Fig. 1). Stem seating was defined as the difference between the top edge of the stem coating and the final broach. Distance maps between the stem and cavity surface were generated to determine the bone-implant contact area and press-fit. All parameters were analysed between 5 mm distal to the coating and 1 cm distal to the lesser trochanter and analysed with related-samples Wilcoxon signed rank and Spearman's correlation tests (IBM SPSS Statistics 22).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 57 - 57
1 Feb 2017
Campbell P Yuan N Luck J Courpron P Park S
Full Access

Recently, a special type of surface pitting found on metal implants was proposed to arise from “inflammatory cell-induced” corrosion (ICI, Figure 1) (1, 2). The actual mechanism of this was unknown, but similar features were suggested to be artefacts of electrocautery damage from revision surgery (3). Under lab conditions and without the influence of any cells, we aimed to reproduce the same surface pits and structures with electrocautery.

Methods

A polished cobalt-chromium disk (40 mm diameter, 8 mm thick) was marked into 8 sections for various testing conditions (Figure 2a). A stainless steel Bovie tip with a unipolar electrocautery machine (SYSTEM 5000, ConMed, USA) was used at typical surgical coagulation conditions: (70 volt, 120 watts, 562 KHz frequency). We mimicked three types of surgical techniques with the electrocautery: “Dotting” was repeated, on and off, direct surface contact; “Dragging” was constant, direct surface contact; “Hovering” was pausing several millimeters above the surface. We also examined the interplay of these practices on diamond-tip-induced scratches and either dry or wet (normal saline) conditions. High magnification images (Keyence VHX-2000E) were taken after the disk was cleaned with laboratory soap, light mechanical scrubbing, and formalin soak.

Results

Coagulation mode generated electrical sparks when dotting/dragging and electrical arcs when hovering. These left seared marks that persisted even after cleaning (Figure 2b). At higher magnification, the surface features were comparable in size and shape to those attributed to ICI (1, 2). Areas wet with saline (Figure 3a) showed an abundance of ringed pits with raised edges that closely resembled those observed in Figure 1. Furthermore we obtained images similar to the phenomenon of “cellular tracks” (Figure 3b) (1). Premade scratches did not influence the pit arrangement but scratches made by the Bovie tip produced the characteristic scratch-associated ICI features as observed on implant retrievals in the past (Figure 3c) (4).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 59 - 59
1 Feb 2017
Campbell D Sharpe K Cohen R
Full Access

Introduction

Cementless tapered wedge stems have shown excellent results over the last decade. Distal potting with inadequate proximal fit, as well as failure to achieve biologic fixation has led to thigh pain, loosening and implant failure. To support a variety of patient morphologies a novel tapered wedge stem was designed with reduced distal morphology, maximizing the proximal contact of the grit blasted surface. The objective of the study was to analyze the clinical outcomes of this stem design.

Methods

Three hundred and nineteen patients enrolled into prospective, post-market multicenter studies received a novel tapered wedge stem. Clinical and patient-reported outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and Euroqol 5D Score (EQ-5D) were evaluated preoperative through two years postoperative.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 55 - 55
1 Feb 2017
Brozyniak C Hitt K Della Valle C Campbell D
Full Access

INTRODUCTION

As the demographic of the patient population requiring revision total knee arthroplasty (rTKA) continues to expand, varying preoperative conditions and activity levels need to be taken into consideration when analyzing postoperative outcomes. Factoring in preoperative activity levels can help manage the expectations of patients. The purpose of this study was to analyze the outcomes of low and high activity patients receiving a contemporary rTKA.

METHODS

One hundred and eighty rTKA patients enrolled in a prospective, multicenter study were evaluated through 2 years postoperative. Patients were divided into groups based on preoperative activity level using the Lower Extremity Activity Scale (LEAS). Patients scoring between 1–7 were classified as ‘Low Activity’ (LA, N=104) and patients scoring 8–18 were classified as ‘High Activity’ (HA, N=76). Clinical and patient-reported outcomes were evaluated, with an additional quality of life analysis completed utilizing SF-6D scores obtained by transforming SF-36 scores through a method described by Brazier et al. and analyzed for effect size.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 85 - 85
1 Feb 2017
Cruz A Perona P Cohen R Campbell D
Full Access

Background

Instability and dislocation are some of the most important postoperative complications and potential causes of failure that dual mobility total hip arthroplasty (THA) systems continue to address. Studies have shown that increasing the relative head size provides patients implanted with smaller and larger cups increased stability, greater ROM and a lesser incidence of impingement, without compromising clinical results. The purpose of the current study was to review clinical outcomes in three groups of primary THA patients receiving a dual mobility acetabular shell.

Methods

In two US based, post-market, multicenter studies, 450 patients received a primary cementless dual mobility THA. Patients were split into three groups based on cup size: ≤ 50mm, 52mm–56mm, and ≥ 58mm. Harris Hip Scores (HHS), Short Form 12 Physical Components (SF12 PCS), Lower Extremity Activity Scores (LEAS), and Euroqol 5D Score (EQ-5Ds) were collected preoperatively and through 2 years postoperative.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 60 - 60
1 Feb 2017
Vanacore C Masini M Westrich G Campbell D Robinson K
Full Access

Introduction

Acetabular revision surgery remains a technically demanding procedure with higher failure rates than primary total hip arthroplasty (THA). An acetabular component with three dimensional porous titanium and anatomic screw holes (Figure 1) was designed to allow the cup to be positioned anatomically and provide reliable fixation.

Methods

A prospective multicenter study of 193 cases (190 patients) was conducted to assess the midterm clinical outcomes of the revision titanium acetabular shell. Radiographs, demographics, Harris Hip Score (HHS), and Short Form 36 (SF-36) were collected preoperatively, at 6 weeks, 3 months, and annually thereafter to 5 years. The mean duration of follow-up was 3.36 years. The Paprosky classification was assessed intraoperatively. Short Form 6D (SF-6D) utility values were obtained by transforming SF-36 scores through the Brazier method and were analyzed for effect size.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 61 - 61
1 Feb 2017
Campbell D Izant T Valentino E
Full Access

1) INTRODUCTION

Acetabular fixation in cementless total hip arthroplasty (THA) relies on new technology for stability and survivorship of the implant. A highly porous 3D titanium coating was developed with a biologically inspired pore structure to improve initial friction fixation with mechanical stability and long term biological fixation. Ongoing research is investigating potential radiographic phenomenons these coatings produce, resulting in the presence of lucent lines. The purpose of this study was to evaluate clinical and radiographic outcomes of a 3D highly porous-coated titanium acetabular shell.

2) METHODS

One hundred and sixty-two cases as part of a non-randomized, post-market, multicenter study received a primary cementless THA. Clinical outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and EuroQol 5D Score (EQ-5D) were collected preoperatively and at six weeks, one year postoperative. Additionally, radiographs, radiographic parameters and techniques were analyzed for institutional differences.