Aims

To identify the responsiveness, minimal clinically important difference (MCID), minimal clinical important change (MIC), and patient-acceptable symptom state (PASS) thresholds in the 36-item Short Form Health Survey questionnaire (SF-36) (v2) for each of the eight dimensions and the total score following total knee arthroplasty (TKA).

Methods

There were 3,321 patients undergoing primary TKA with preoperative and one-year postoperative SF-36 scores. At one-year patients were asked how satisfied they were and “How much did the knee arthroplasty surgery improve the quality of your life?”, which was graded as: great, moderate, little (n = 277), none (n = 98), or worse.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 82 - 82
1 Jul 2022
Walker L Clement N Deehan D
Full Access

Abstract

Introduction

The prevalence of recurrent infection following two-stage exchange arthroplasty following failure of a total knee arthroplasty (TKA) has been reported to be 10% to 25%. There is limited literature available on repeat two stage revisions for TKA infection with only small cohorts and variable success rates.

Methodology

A retrospective cohort study investigating the outcome of two stage revision arthroplasty for treatment of TKA infection was conducted with the aim of identifying factors linked to recurrence of infection. A consecutive cohort of all microbiology intra-operative periprosthetic knee samples from a single revision arthroplasty centre between January 2010 and December 2016 was identified. The final cohort consisted of 658 samples taken during 64 patients undergoing two stage revision knee surgery for infection. Patient demographics, medical and orthopaedic history data including post-operative outcomes and subsequent treatment was obtained from the electronic records system and medical notes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 11 - 11
1 Jul 2012
Jameson S Dowen D James P Reed M Deehan D
Full Access

Introduction

Unlike the NJR, no surgeon driven national database currently exists for ligament surgery in the UK and therefore information on outcome and adverse event is limited to case series.

Methods

Prospectively collected Hospital episode statistics (HES) data for England was analysed so as to determine national rates of 90-day symptomatic deep venous thrombosis (DVT), pulmonary thromboembolism (PTE) rate, significant wound infection and 30-day readmission rates with cause following anterior cruciate ligament (ACL) reconstruction. This diagnostic and operative codes information is routinely collected on every patient admitted to hospital in England NHS.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 46 - 46
1 Jul 2012
Moore O Cloke D Avery P Beasley I Deehan D
Full Access

The aim of this study was to describe the epidemiology of elite youth soccer knee injuries from prospective data collected from forty-one English FA Football Academies over a 5 year period. 12306 players were registered from U9 to the U16 age category.

We studied the incidence of injuries around the knee with particular emphasis upon those causing greater than 28 days time off sport.

There were 609 knee injuries with a mean incidence of 0.71 knee injuries per player per year and a median of 17 training days and 2 matches missed per knee injury. Increased injury rates were seen in older players, in competitive situations and in the latter stages of each half of play. Peaks in injury numbers were seen in early season and subsequent to the winter break. Sprain was the most common diagnosis with the Medial Collateral ligament affected in 23.2% of cases. 609 injuries met the UEFA Model criteria for major injury. In total 60,091 training days and 5,272 match appearances were lost through knee injury.

Knee injuries are common in elite level youth footballers and are often severe in nature, resulting in large amounts of training time lost to injury. Diagnosis of ligament sprain is common leading to prolonged time off, and may mask more serious pathology or inappropriate management.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 57 - 57
1 Jul 2012
Malviya A Brewster N Weir D Holland J Deehan D
Full Access

Introduction

We wished to quantify the influence of constraint and various principal indications upon functional outcome following aseptic first time revision knee arthroplasty.

Methods

In this single centre, prospective study we have looked into the outcome of 175 total revision knee replacement performed between 2003 and 2008 at a minimum follow-up of 1 year. Data was refined to allow for examination exclusively of those cases where the level of constraint was increased from cruciate retaining or cruciate sacrificing knee replacement to either non linked constrained implant (condylar constrained) or linked constrained (rotating hinge) prosthesis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 93 - 93
1 Mar 2012
Stoddard J McCaskie A Deehan D Amis A
Full Access

Purpose of the study

To compare the patellofemoral kinematics and patella stability of a new TKR, with a continuous radius versus an established J shaped knee system and the natural knee. It was hypothesised that the high performance new TKR would be a better match to the natural knee and anatomical patella tracking would provide a more stable patella.

Methods

A cadaveric study using physiological loads examined the continuous kinematic behaviour (optical tracking system) of the tibiofemoral and patellofemoral compartments in 6 knees for the native, kinemax and new design triathlon knee systems.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 604 - 611
1 May 2009
Reay E Wu J Holland J Deehan D

We describe a cohort of patients with a high rate of mid-term failure following Kinemax Plus total knee replacement inserted between 1998 and 2001. This implant has been recorded as having a survival rate of 96% at ten years. However, in our series the survival rate was 75% at nine years. This was also significantly lower than that of subsequent consecutive series of PFC Sigma knee replacements performed by the same surgeon. No differences were found in the clinical and radiological parameters between the two groups. At revision the most striking finding was polyethylene wear. An independent analysis of the polyethylene components was therefore undertaken. Scanning electron microscopy revealed type 2 fusion defects in the ultra-high molecular weight polyethylene (UHMWPE), which indicated incomplete boundary fusion. Other abnormalities consistent with weak UHMWPE particle interface strength were present in both the explanted inserts and in unused inserts from the same period.

We consider that these type 2 fusion defects are the cause of the early failure of the Kinemax implants. This may represent a manufacturing defect resulting in a form of programmed polyethylene failure.