Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Trauma

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 141 - 141
1 Sep 2012
Badawy M Espehaug B Indrekvam K Furnes O
Full Access

Background

Improving quality and efficiency is a priority in health policy. Several studies have shown a correlation between high hospital volume and improved results of surgery. In Norway, orthopaedic surgeons operate a relatively low number of total knee replacements compared with other countries. The number of total knee replacements has, however, increased significantly over the past 10 years.

Some studies have also shown an association between surgeon volume and outcomes after total knee arthroplasty (TKA).

Purpose

We wanted to study a possible correlation between prosthesis survival and surgery volume of TKA, both with respect to hospital volume and surgeon volume.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 9 - 9
1 Sep 2012
Gothesen O Espehaug B Havelin L Petursson G Furnes O
Full Access

Background

Improving positioning and alignment by the use of computer assisted surgery (CAS) might improve longevity and function in total knee replacements. This study evaluates the short term results of computer navigated knee replacements based on data from a national register.

Patients and Methods

Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The five most common implants and the three most common navigation systems were selected. Cemented, uncemented and hybrid knees were included. With the risk for revision due to any cause as the primary end-point, 1465 computer navigated knee replacements (CAS) were evaluated against 8214 conventionally operated knee replacements (CON). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis and ASA category were used.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 230 - 230
1 Sep 2012
Matre K Vinje T Havelin LI Gjertsen J Furnes O Espehaug B Fevang J
Full Access

Introduction

The treatment of trochanteric and subtrochanteric fractures remains controversial, and new implants are constantly being developed trying to improve outcome and minimize the number of complications in these fractures.

In Norway the Sliding Hip Screw(SHS), with or without a Trochanteric Stabilizing Plate (TSP), is still the most commonly used implant, but worldwide nailing of these fractures is increasing. This trend, however, has not been supported by documentation of better clinical results compared to the SHS in well designed studies. Therefore, in the present study we compared the recently launched Trigen Intertan nail (Smith and Nephew) with the SHS in the treatment of trochanteric and subtrochanteric fractures.

Patients and Methods

In a prospective, randomized multicenter study with 697 patients, we compared the Trigen Intertan nail with the SHS regarding postoperative pain, functional mobility, complications, and reoperation rates.

Patients older than 60 years with trochanteric and subtrochanteric fractures were included in 5 hospitals. At day 5, and 3 and 12 months postoperatively, pain was measured using a Visual Analogue Scale (VAS), and the Timed Up and Go-test (TUG-test) was performed to evaluate functional mobility. Complications and reoperations were recorded at discharge, and after 3 and 12 months.