Vol. 95-B, Issue SUPP_34 | Pages 216 - 216
1 Dec 2013
Abdulkarim A Ellanti P Motterlini N Fahey T O'Byrne JM
Full Access

The optimal method of fixation for primary total hip replacements (THR), particularly fixation with or without the use of cement is still controversial.

In a systematic review and meta-analysis of all randomized controlled trials (RCT) comparing cemented versus uncemented THRS available in the published literature, we found that there is no significant difference between cemented and uncemented THRs in terms implant survival as measured by the revision rate.

Better short-term clinical outcome, particularly an improved pain score can be obtained with cemented fixation. However, the results are unclear for the long-term clinical and functional outcome between the two groups. No difference was evident in the mortality and the post operative complication rate. On the other hand, the Radiographic findings were variable and do not seem to correlate with clinical findings as differences in the surgical technique and prosthesis design might be associated with the incidence of osteolysis.

We concluded in our review that Cemented THR is similar if not superior to uncemented THR, and provides better short term clinical outcomes. Further research, improved methodology and longer follow up are necessary to better define specific subgroups of patients in whom the relative benefits of cemented and uncemented implant fixation can be clearly demonstrated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 106 - 106
1 Mar 2012
Ellanti P Ashraf M Thakaral R McCarthy T O'Sulllivan K McElwain J
Full Access

Introduction

It is recommended that the ankle be held in dorsiflexion at the time of placement of syndesmosis screw. We assessed the validity of this recommendation.

Materials and methods

A two-part roentgenographic and computerised analysis of distal tibiofibular syndesmosis. The first part involved recruitment of 30 healthy adult volunteers. The second part involved 15 ankle fractures with syndesmotic injury requiring syndesmosis screw placement. In the first part individuals maximally dorsiflexed and plantarflexed their ankles in a specialised jig for standardisation. Mortice views were taken and intermalleolar distance measured. In the second part mortice views were taken in plantarflexion and dorsiflexion before and after the placement of syndesmosis screw in theatre. The intermalleolar distance was then measured.