We describe the routine imaging practices of
Level 1 trauma centres for patients with severe pelvic ring fractures, and
the interobserver reliability of the classification systems of these
fractures using plain radiographs and three-dimensional (3D) CT
reconstructions. Clinical and imaging data for 187 adult patients
(139 men and 48 women, mean age 43 years (15 to 101)) with a severe
pelvic ring fracture managed at two Level 1 trauma centres between July
2007 and June 2010 were extracted. Three experienced orthopaedic
surgeons classified the plain radiographs and 3D CT reconstruction
images of 100 patients using the Tile/AO and Young–Burgess systems.
Reliability was compared using kappa statistics. A total of
115 patients (62%) had plain radiographs as well as two-dimensional
(2D) CT and 3D CT reconstructions, 52 patients (28%) had plain films
only, 12 (6.4%) had 2D and 3D CT reconstructions images only, and
eight patients (4.3%) had no available images. The plain radiograph
was limited to an anteroposterior pelvic view. Patients without
imaging, or only plain films, were more severely injured. A total
of 72 patients (39%) were imaged with a pelvic binder Interobserver reliability for the Tile/AO (Kappa 0.10 to 0.17)
and Young–Burgess (Kappa 0.09 to 0.21) was low, and insufficient
for clinical and research purposes. Severe pelvic ring fractures are difficult to classify due to
their complexity, the increasing use of early treatment such as
with pelvic binders, and the absence of imaging altogether in important
patient sub-groups, such as those who die early of their injuries. Cite this article:
Traumatic disruption of the pelvic ring has a high risk of mortality. These injuries are predominantly due to high-energy, blunt trauma and severe associated injuries are prevalent, increasing management complexity. This population-based study investigated predictors of mortality following severe pelvic ring fractures managed in an organised trauma system. Cases aged greater than 15 years from 1st July 2001 to 30th June 2008 were extracted from the population-based state-wide Victorian State Trauma Registry for analysis. Patient demographic, pre-hospital and admission characteristics were considered as potential predictors of mortality. Multivariate logistic regression was used to identify predictors of mortality with adjusted odds ratios (AOR) and 95% confidence intervals (CI) calculated. There were 348 cases over the 8-year period. The mortality rate was 19%. Patients aged greater than 65 years were at higher odds of mortality (AOR 7.6, 95% CI: 2.8, 20.4) than patients aged 15–34 years. Patients hypotensive at the scene (AOR 5.5, 95% CI: 2.3, 13.2), and on arrival at the definitive hospital of care (AOR 3.7, 955 CI: 1.7, 8.0), were more likely to die than patients without hypotension. The presence of a severe chest injury was associated with an increased odds of mortality (AOR 2.8, 95% CI: 1.3, 6.1), while patients injured in intentional events were also more likely to die than patients involved in unintentional events (AOR 4.9, 95% CI: 1.6, 15.6). There was no association between the hospital of definitive management and mortality after adjustment for other variables, despite differences in the protocols for managing these patients at the major trauma services (Level 1 trauma centres). The findings highlight the importance of the need for effective control of haemodynamic instability for reducing the risk of mortality. As most patients survive these injuries, further research should focus on long term morbidity and the impact of different treatment approaches.
Osteochondral fracture of the femoral head is an uncommon injury with a high potential for a poor functional outcome. Management is often challenging with limited options. We present two cases in which osteochondral fractures of the femoral head were treated with partial resurfacing using the HemiCAP System (Arthrosuface, Franklin MA, USA). A 22-year-old male professional motorbike rider presented with an anterior left hip dislocation that occurred during a race. A CT scan after a closed reduction revealed a large osteochondral impaction fracture/defect that was addressed via partial resurfacing using the HemiCAP System. A 34-year-old male presented with an anterior left hip dislocation after a motor vehicle accident and underwent a closed reduction. CT showed a loose osteochondral fragment, that was fixed back with headless screws, and an adjacent defect was addressed with a HemiCAP implant. Both patients were kept non weight-bearing for two months and had an uneventful recovery. Patient 1 was last reviewed at our institution one month post-operatively with a pain-free hip. His follow-up is being continued interstate and at telephone interview, 18 months after surgery, he had returned to full function and resumed riding on the professional racing circuit. Patient 2, at three-month review, had a pain-free hip with a full range of motion. CT scan showed excellent joint surface congruity at the implant articular surface junction. We report the use of the HemiCAP System as a novel method of treating osteochondral defects, which has never been reported before. There has only been one other reported case of using a HemiCAP in an osteoarthritic femoral head. This is a short follow-up with only two patients treated; however we are encouraged by the results so far, as there are no other satisfactory alternative treatment options.Patient 1
Patient 2
The treatment of those fractures varies from conservative treatment, posterior plate fixation, anterior plating as well as percutaneous and open Sacroiliac (SI) joint screws. However, screw pull-outs and loss of fixation in those methods are well described In the Alfred Hospital, Melbourne (Australia) a Level 1 Trauma Center a series of 14 patients were treated from 10/2006 to date with a multiaxial spinal system.
A pedicel screw from a multiaxial spinal system (Xia, Stryker or Pangea, Synthes) is placed percutaneously in the posterior iliac crest on both sides and the reduction is performed with the screws attached to the screw handles and with Image Intensifier. After the reduction the multiaxial screwheads are bent and transfixed with a bar which is tunneled epifacial. All patients underwent a multislice pelvic and lumbar spine CT and these patients were assessed clinically for neurovascular symptoms and stability. The follow-up included clinical assessment and CT imaging.
The follow up time was one to 18 month. The patients were assessed clinically and with CT imaging. No complications or loss of fixation have been observed in this patient group in this short follow up time.
The construct provides initial stability and allows mobilization of the patient. It can be used in cases with sacral comminution and may offer advantages over posterior plate fixation, by reducing complications with prominent metalware.
Pelvic fractures in multi-trauma patients are an indicator of severe trauma and often require advanced wound management of pelvic, abdominal or extremity injuries. Poor wound management may result infected pelvic hardware, necessitating revision surgery. We propose that TNP is a safe method of wound management and report our experience. In 2006 91 multi-trauma patients required pelvic/ace-tabular fixation at The Alfred, either internal or external. Of those, 23 needed TNP for wound care of pelvic, abdominal or extremity injuries. Indications for TNP included Morel-Lavelle lesions, concomitant bladder disruption with anterior wounds, severe edema preventing any wound closure, extremity open fractures/degloving/fasciotomies and post-op infections. The average age of the group was 33, the average injury severity score was 36, 5 were female, 18 were male. There was one pelvic wound infection that resolved with TNP and local wound care. Two unsalvageable limbs (one transhumeral, one transfemoral) required amputation after TNP, all others were either closed primarily or with a flap and skin graft. There was one death in the group from unrelated causes. Pelvic scores, SF-12, visual analog pain scores and sexual dysfunction rates are being gathered and will be reported. Topical negative pressure is a safe and effective method of managing complex wounds in multi-trauma patients with pelvic injuries.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.
A retrospective review of 1542 Charnley low-friction arthroplasties was carried out to compare the incidence of deep infection arising after plain and gentamicin-containing acrylic cement. There was no significant difference between the two series in primary operations, the infection rate being 1.72% and 1.65% respectively. However, in secondary operations (conversions and revisions) the gentamicin-containing cement gave significantly better results--a 0.81% infection rate as compared with 3.46%. All operations were performed in a clean air enclosure using total-body exhaust suits. Radiological diagnosis of deep infection was possible within one year of operation in all cases. Late haematogenous infection occurred in one case and was related to a skin lesion.
Total hip replacement has been very successful in patients with painful, stiff hips associated with protrusio acetabuli, but the heat of polymerisation of methylmethacrylate cement may cause necrosis of the thin medial wall with consequent danger of migration of the cup. Since 1968 at Wrightington, thin slices of the head of the femur have been used as bone grafts to reinforce the acetabulum. We have reviewed 61 hips in 51 patients at an average of 4 years 3 months after operation. Grading for severity is discussed and the degree of physiological remodelling of the medial wall of the acetabulum after grafting assessed. There was an average of about 4 mm of remodelling, but this varied considerably; most took place within the first year. In no case was there relapse of the protrusio.
In a randomised prospective trial 98 elderly women with trochanteric fractures of the femur were treated with either a 135 degrees Jewett nail-plate or a 135 degrees Dynamic hip screw. The results at six weeks, three months and six months were statistically analysed. There were no significant differences in the two groups with regard to pain, length of hospital stay, morbidity or mortality. Although operative difficulties and open reduction were more common with the Dynamic hip screw, at the end of six months more patients in this group were mobile and there was significant radiological evidence of better compression without loss of fixation.