Patients with abnormal spinopelvic mobility are at increased risk for instability. Measuring the change in sacral slope (ΔSS) can help determine spinopelvic mobility preoperatively. Sacral slope (SS) should decrease at least 10° to demonstrate adequate posterior pelvic tilt. There is potential for different ΔSS measurements in the same patient based on sitting posture. The purpose of this study was to determine the effect of sitting posture on the ΔSS in patients undergoing total hip arthroplasty (THA). In total, 51 patients undergoing THA were reviewed to quantify the variability in preoperative spinopelvic mobility when measuring two different sitting positions using SS for planning.Aims
Methods
Aseptic loosening of the tibial component is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include an isolated tibial revision or full component revision. A full component revision is frequently selected by surgeons unfamiliar with the existing implant or who simply wish to “start again”. This option adds morbidity compared with an isolated tibial revision. While isolated tibial revision has a lower morbidity, it is technically more challenging due to difficulties with exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Patients undergoing revision TKA for isolated aseptic tibial loosening between 2012 and 2017 were identified. Those with revision implants or revised for infection, instability, osteolysis, or femoral component loosening were excluded. A total of 164 patients were included; 88 had an isolated tibial revision and 76 had revision of both components despite only having a loose tibial component. The demographics and clinical and radiological outcomes were recorded.Aims
Methods
Extraction of implants due to periprosthetic infection (PJI) following complex revision total knee arthroplasty (rTKA) with extensive hardware can be a daunting undertaking for surgeon and patient alike. We question whether irrigation and debridement (I&D) has a role in this difficult situation with respect to infection control, reoperation, and function. rTKAs for PJI from 2005–2016 were reviewed. Extensive hardware was defined as: metaphyseal cone/sleeve fixation, distal femoral replacement, periprosthetic fracture hardware, or stems >75mm. Cases were categorized by treatment (I&D or 2-stage exchange).Introduction
Methods
Previous in vivo fluoroscopic studies have documented that subjects having a PS TKA experience a more posterior condylar contact position at full extension, a high incidence of reverse axial rotation and mid flexion instability. More recently, a PS TKA was designed with a Gradually Reducing Radius (Gradius) curved condylar geometry to offer patients greater mid flexion stability while reducing the incidence of reverse axial rotation and maintaining posterior condylar rollback. Therefore, the objective of this study was to assess the in vivo kinematics for subjects implanted with a Gradius curved condylar geometry to determine if these subjects experience an advantage over previously designed TKA. In vivo kinematics for 30 clinically successful patients all having a Gradius designed PS fixed bearing TKA with a symmetric tibia were assessed using mobile fluoroscopy. All of the subjects were scored to be clinically successful. In vivo kinematics were determined using a 3D-2D registration during three weight-bearing activities: deep-knee-bend (DKB), gait, and ramp down (RD). Flexion measurements were recorded using a digital goniometer while ground reaction forces were collected using a force plate as well. The subjects then assessed for range of motion, condyle translation and axial rotation and ground reaction forces.Background
Methods
The direct anterior approach (DAA) for total hip arthroplasty (THA) is marketed with claims of superiority over other approaches. Femoral exposure can be technically challenging and potentially lead to early failure. We examined whether surgical approach is associated with early THA failure. A retrospective review of 478 consecutive early revision THAs within five years of primary THA at three academic centers from 2011 through 2014 was performed. Exclusion criteria resulted in a final analysis sample of 341 early failure THAs. Primary surgical approach was documented for each revision, along with time to revision, and failure etiology.Background
Methods
Patient charts and radiographs were reviewed. Statistical analysis was performed. Significant variables associated with patient anatomy, implant size and alignment were subsequently investigated in a computational model to evaluate tendofemoral contact.