Accurate acetabular cup orientation could lead to successful surgical results in total hip arthroplasty (THA). We introduce a novel CT-based three-dimensional (3D) planning system, HipCOMPASS (Fig.1) and TARGET (Fig.2), which enable to design suitable alignment not only cup also surgical devices calculatingly, according to each pelvic inclination. We performed THA in 45 hips in 43 patients (female 37 and 6 men) between April 2014 and October 2015. Average age were 68 years old. THA operation was based on each parameter of the cup and device, providing a preoperative planning by ZedView system. HipCOMPASS and TARGET is linked with ZedView software, which is simultaneously calibrated adjustable parameters on this devices. Cup alignment was assessed by ZedView as well.Introduction
Patients and Methods
In total knee arthroplasty (TKA), the setting position of component and the angle influence surgical results. 3D matching evaluation method using the CT before and after operation was a useful method as a rating system after operation. The anterior femoral cortical line (AFCL) is an anatomical landmark for determining intraoperative femoral component rotation in total knee arthroplasty (Fig.1). Our aim in this study is to evaluate the effectiveness of the JIGEN (Jig Engaged 3D Pre-Operative Planning System for TKA) (LEXI, Japan) operation support system using AFCL. We performed TKA used GENUS MB (Adler, Italy) by January, 2015 from October, 2013. As for 5 male knees, 37 woman knees, the operation average age were 68 years old. The operation was based on each insertion parameter of the rod in marrow provided by a preoperative plan by the JIGEN system and at first installed a target device in the femoral front and manufactured a insertion point and inserted a rod in the marrow to plan insertion depth (Figure 1). We performed CT photography of the whole lower limbs after operation like preoperation and femoral component setting was located after operation using evaluation software (LEXI, Japan) and evaluated it.Introduction
Patients and methods
Accurate acetabular cup orientation could lead to successful surgical results in total hip arthroplasty (THA). We introduce a novel CT-based three-dimensional (3D) planning system, HipCOMPASS (Fg.1) and TARGET (Fig.2), which enable to design suitable alignment not only cup also surgical devices calculatingly, according to each pelvic inclination. We performed THA in 13 patients (10 female and 3 men) between September 2014 and April 2014. Average age were 67 years old. THA operation was based on each parameter of the cup and device, providing a preoperative planning by ZedView system. HipCOMPASS and TARGET is linked with ZedView software, which is simultaneously calibrated adjustable parameters on this devices. Cup alignment was assessed by ZedView as well.Introduction
Patients and methods
Between 2002 and 2011, 81 patients with a traumatic total brachial
plexus injury underwent reconstruction by double free muscle transfer
(DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve
transfers (NT, 18 cases). They were evaluated for functional outcome and quality of life
(QoL) using the Disability of Arm, Shoulder and Hand questionnaire,
both pre- and post-operatively. The three groups were compared and
followed-up for at least 24 months.Aims
Methods
Friction between bearing surfaces in Total Hip Arthroplasty has been a main target of applied tribology. MPC (2-Methacryloyloxyethyl phosphorylcholine) has a similar properties to those of cell membranes, and can reduce friction with fluid lubrication in wet environment. We have used crosslink polyethylene with MPC polymer coating for primary and revision THA since 2011. We have examined 19 cases which were followed for more than two years. Sixteen cases for primary THA and three for revision THA, and 3 were male and 16 were female. Sixteen cases were osteoarthritis, one osteonecrosis of femoral head and two rheumatoid arthritis. Average age of patients at THA was 60.1 years old. In the OR, we have experienced a very wet and slippery feeling on the bearing surface of polyethylene liner. Surface touch is similar to hard surface with oil or lotions. No PE wear were measured on the X-ray display and no infections and no fractures were occurred during follow up. MPC polymer coating in THA can be useful for reduction of friction and generation of wear debris.
The purpose of this study is to investigate the diagnostic value of evoked spinal cord potentials (ESCPs) and choline acetyltransferase (CAT) activity during exploration of injuries to the brachial plexus. We assessed 25 spinal roots in 19 patients. The results of the two investigations were consistent in all except two roots. Although assessment of ESCPs is easy and quick, it mainly records the nerve potentials along the sensory pathway. Although measurement of CAT activity needs a specimen of the nerve and the availability of a radioisotope laboratory, it gives direct information regarding the motor function of ventral spinal roots. These two techniques should be complementary to each other in order to achieve a more accurate diagnosis.
One pattern of injury to the brachial plexus shows recovery of the fifth and sixth cervical nerves but little else. These patients have useful shoulders and functional elbow flexion, but elbow and wrist extension is weak or absent. Their hand function is negligible. We restored hand function in three such patients using free functioning muscle transfer for finger flexion and transfer of the sensory rami of the intercostal nerve to the ulnar nerve for sensation. Supplementary operations to restore elbow and wrist extension were necessary in one patient.