Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 54 - 54
1 Apr 2018
Hayden B Damsgaard C Talmo C Murphy S
Full Access

INTRODUCTION

Interest in tissue-preserving or minimally invasive total hip arthroplasty (THA) is increasing with focus toward decreased hospital stay, enhanced rehabilitation, and quicker recovery for patients. Two tissue-preserving techniques, the anterior and superior approaches to THA, have excellent clinical results, but little is known about their relative impact on soft tissue. The purpose of this study was to evaluate the type and extent of tissue damage after THA with each approach, focusing on abductors, short external rotators, and the hip capsule.

METHODS

Total hip arthroplasty was performed on bilateral hips of eleven fresh-frozen cadavers (22 hips). They were randomized to anterior THA performed on one side and superior THA performed on the other, in the senior authors' standard technique. Two independent examiners graded the location and extent of tissue injury by performing postsurgical dissections. Muscle bellies, tendons, and capsular attachments were graded as intact, split, damaged (insignificant, minimal, moderate, or extensive damage), or detached based on direct visual inspection of each structure. Tissue injury was analyzed with either a chi-squared (≥5 qualifying structures) or Fisher's exact test (<5 qualifying structures). P values <0.05 were significant.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 74 - 74
1 Dec 2017
Murphy WS Kowal JH Hayden B Yun HH Murphy SB
Full Access

Introduction

Cup malpositioning remains a common cause of dislocation, wear, osteolysis, and revision. The concept of a “Safe Zone” for acetabular component orientation was introduced more than 35 years ago1. The current study assesses CT studies of replaced hips to assess the concept of a safe zone for acetabular orientation by comparing the orientation of acetabular components revised due to recurrent instability and to a series of stable hip replacements.

Methods

Cup orientation in 50 hips revised for recurrent instability was measured using CT. These hips were compared to a group of 184 stable hips measured using the same methods. Femoral anteversion in the stable hips was also measured.

Images to assess femoral anteversion in the unstable group were not available. An application specific software modules was developed to measure cup orientation using CT (HipSextant Research Application 1.0.13 Surgical Planning Associates Inc., Boston, Massachusetts). The cup orientation was determined by first identifying Anterior Pelvic Plane Coordinate system landmarks on a 3D surface model. A multiplanar reconstruction module then allowed for the creation of a plane parallel with the opening plane of the acetabulum. The orientation of the cup opening plane in the AP Plane coordinate space was calculated according to Murray's definitions of operative anteversion and operative inclination2. Both absolute cup position relative to the APP and tilt-adjusted cup position3 were calculated.