Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 1 - 1
1 Apr 2019
Kutsuna T Hino K Watamori K Kiyomatsu H Miura H
Full Access

Background

Patient satisfaction after total knee arthroplasty (TKA) has been lower than after a similar procedure, total hip arthroplasty. Poor subjective outcomes after TKA may be partially explained by abnormal kinematics patterns after TKA. The purpose of this study was to analyse rotational kinematics patterns in knees that had undergone posterior stabilized (PS)-TKA, and to clarify the relationships between rotational kinematics patterns and patient satisfaction, as well as between rotational kinematics patterns and knee function.

Materials & Methods

A total of 49 osteoarthritis knees after primary PS-TKA (NexGen LPS-Flex fixed bearing knee system) were included in this study; deformed valgus, severe flexion contractures, and highly unstable knees were excluded. We used a computer navigation system and measured knee kinematics after each surgery was completed. A single investigator gently applied a manual range of motion from full extension to flexion. The angle of the internal rotation of the tibia was measured automatically at 0º, 30º, 45º, 60º, and 90º, along with maximum extension and flexion. We categorized the post-operative rotational kinematics patterns for individual cases, focusing on the initial knee flexion from 0–30º. Type A corresponded to an increased internal rotation angle of the tibia during the initial knee flexion (screw home-like movement). Type B corresponded to an increased external or an unchanged rotation angle of the tibia. We examined the range of motion (ROM) at 6 months after surgery and assessed the 2011 Knee Society Score (2011 KSS) at ≥1 year following surgery.

Statistical analysis. The difference between the two groups was compared using a Wilcoxon rank sum test. Analyses were performed with JMP statistical software v8.0 (SAS Institute). A p-value of <0.05 was regarded as significant.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 41 - 41
1 Jan 2016
Hino K Onishi Y Kutsuna T Watamori K Kiyomatsu H Miura H
Full Access

Introduction

Correct alignment is important for a successful result after total knee arthroplasty (TKA). During most activities of daily living, the knee is loaded not only in full extension but also in mid-flexion. However, there are few methods to evaluate mid-flexion varus-valgus alignment, despite its clinical significance. Computer navigation systems are useful for intra-operative monitoring of joint positioning and movements. Knee ligaments contribute to induce kinematics of the joint. It is likely that the presence of posterior cruciate ligament has some effects on kinematics throughout flexion. The purpose of this study was to evaluate changes in the varus–valgus alignment of the femoral–tibial mechanical axis in each flexion angle before and after TKA by using a navigation system, and to evaluate varus–valgus kinematic patterns throughout flexion, and compare preoperative and postoperative changes of kinematic patterns in CR-TKA and PS-TKA procedures.

Material and Method

Forty knees that underwent TKA with computer navigation system were evaluated (CR-TKA 20; PS-TKA 20). CR and PS TKRs were implanted in alternating sequence. The investigator applied manual mild passive knee flexion, while moving the leg from full extension to flexion and the varus-valgus angle of femoral-tibial mechanical axis was measured automatically by the navigation system at every 10 ° throughout flexion. We classified kinematic patterns in the varus–valgus direction throughout flexion.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 113 - 113
1 Jan 2016
Kiyomatsu H Hino K Kutsuna T Watamori K Onishi Y Miura H
Full Access

Introduction

Total knee arthroprasty (TKA) is an excellent treatment with osteoarthritis of the knee joint. The acquisition of joint stability after TKA is one of the most important factors to improve the patient's quality of life. Deep flexion of knee joint is often demanded in daily life, and stability in flexed knee position is also important. But there were few papers reporting about laxity in flexed knee position. This study aimed to analyze influence of pre-operative alignment on post-operative varus-valgus joint laxity in TKA. We investigated the varus-valgus laxity of knee joint throughout flexion intra-operatively before and after prosthetic implantation.

Methods

A total of 20 knees underwent TKA using posterior-stabilised (PS) type component by the measured resection method were included in this study. The varus-valgus joint laxity of knee was measured using an intra-operative navigation system at every 10 ° throughout the range of movement under general anesthesia. We examined the correlations between the pre-operative femorotibial angle (FTA) and varus-valgus joint laxity by method of least squeres. We divided the patients group into two populations according to pre-operative FTA. Large FTA group had more than or equal to 186 °of pre-operative FTA. Small FTA group had less than 186 °pre-operative FTA. T- test was performed between those populations.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 119 - 119
1 Jan 2016
Watamori K Ishimaru M Onishi Y Hino K Miura H
Full Access

Introduction

Previous anthropometric studies have reported gender differences in distal femoral morphology. After total knee arthroplasty, females have a higher prevalence of medial or lateral femoral component overhang, which could be responsible for postoperative knee pain and decreased range of motion. Consequently, gender-specific knee prostheses were designed to accommodate female morphology. However, to date, very few studies have investigated the knee morphology of Japanese adults and possible gender differences. The purpose of this study was to examine the distal femoral morphology of Japanese patients, to characterize anatomical differences between men and women, and to evaluate the need to create gender-specific knee prostheses.

Material and Methods

We evaluated 107 knees in 17 male and 90 female Japanese patients for total knee arthroplasty (TKA)[fig.1]. The medial-lateral (ML) and anteroposterior (AP) dimensions of the knees at different levels evaluated intraoperative measurement, and ML/AP aspect ratios were calculated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 133 - 133
1 Jan 2016
Kutsuna T Hino K Onishi Y Watamori K Miura H
Full Access

Purpose

The purpose of this study was to analyze rotational kinematic patterns in knees treated with either cruciate-retaining (CR) or posterior-stabilized (PS) total knee arthroplasty (TKA), using an intra-operative navigation technique, and to clarify the factors that affect of the rotational kinematics and the difference rotational kinematics patterns between CR- and PS- TKA.

Methods

A total of 35 knees (35 patients) were included in this study, deformed valgus, sever flexion contractures, and highly unstable knees were excluded. These knees were allocated to CR (NexGen CR-Flex) or PS (NexGen PS-Flex) implants and underwent TKA with a computer navigation technique (precision N Knee Navigation Software v4.0; Stryker). There was no significant difference in pre-operative parameters between CR- and PS-TKA group: age, femorotibial angle (FTA), and chondylar twist angle (CTA).

We measured two points during surgery. First, the skin incision was made and subcutaneous tissue was exposed. The joint capsule was temporality closed by three or four strand suture. Second, after the surgery was completed with satisfactory alignment and soft tissue balance, immediately following wound closure the measurement procedure was repeated.

The surgeon gently applied a manual range of motion from full extension to flexion. The angle of internal rotation in tibia to the functional plane of tibia and femur was measured automatically at max extension, 0, 30, 45, 60, 90 degrees, and max flexion throughout the passive knee motion.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 105 - 105
1 Jan 2016
Onishi Y Ishimaru M Hino K Shiraishi Y Miura H
Full Access

Introduction

MERA Quest Knee System (Quest Knee) is a posterior cruciate ligament–retaining prosthesis considering the anatomical features and lifestyles of the Japanese. As for the anatomical features, we reduced the size of prosthesis and set a smaller interval of sizes because Japanese knees are smaller and flatter than those of Caucasians. As for the lifestyles, we evaluated in vivo patellar tracking during deep knee flexion and the condylar geometry in the axial plane of magnetic resonance imaging. It was found that the patella sank deeply into the intercondylar notch and that the articular surface of the lateral condyle began to curve steeply. We adopted this shape and engraved the lateral condyle deep to reduce the pressure of the patellofemoral joint and to get better range of motion (ROM). For the contact pressure rise in the femorotibial joint by engraving the lateral condyle, the insert was suited to the shape of the femoral component. Furthermore, we increased the thickness of the posterior flange of the femoral component and changed the posterior radius of curvature gradually, and this shape allowed the flexion of 155°. We have used Quest Knee for clinical applications from October 2009. We studied the short-term results of Quest Knee.

Methods

Between June 2010 and July 2013, the same senior surgeon performed 59 consecutive primary operations with Quest Knee. Forty patients (44 knees) were women, and 14 patients (15 knees) were men. The mean patient age was 72.5 years (range, 59–89 years). All were osteoarthritis knees. Coronal deformity was varus in 58 knees and valgus in one knee. All operations were performed with a measured resection technique, and all patellae were resurfaced. Clinical evaluations were assessed using the Japanese Orthopaedic Association knee rating score (JOA score), and clinical ROM and standing femorotibial angle (FTA) were measured. Additionally, three-dimensional motion analysis of the patellar component during squatting was performed by the image matching method with image correlations.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 355 - 355
1 Dec 2013
Ishimaru M Shiraishi Y Hino K Onishi Y Miura H
Full Access

Introduction:

The widespread use of TKA promoted studies on kinematics after TKA, particularly of the femorotibial joint. Knee joint kinematics after TKA, including the range of motion (ROM) and the physical performance, are also influenced by the biomechanical properties of the patella. Surgeons sometimes report complications after TKA involvinganterior knee pain, patellofemoral impingement and instability. However, only few studies have focused specially on the patella. Because the patella bone is small and overlapped with the femoral component on scan images. In addition, the patellar component in TKA is made of x-ray–permeable ultra-high molecular weight polyethylene. It is impossible to radiographically determine the external contour of the patellar component precisely. No methods have been established to date to track the dynamic in vivo trajectory of the patella component. In this study, we analyzed the in vivo three-dimensional kinematics of the patellar component in TKA by applying our image matching method with image correlations.

Methods:

A computed tomography (CT) and an x-ray flat panel detector system (FPD) were used. FPD-derived post-TKA x-ray images of the residual patellar bone were matched by computer simulation with the virtual simulation images created using pre-TKA CT data. For the anatomic location of the patellar component, the positions of the holes drilled for the patellar component pegs were used. This study included three patients with a mean age of 68 years (three females with right knee replacement) who had undergone TKA with the Quest Knee System and achieved a mean passive ROM of 0 to ≥ 130° after 6 or more month post-TKA. We investigated three-dimensional movements of the patellar component in six degrees of freedom (6 DOF) during squatting and kneeling. Furthermore, we simulated the three-dimensional movement of the patellar component, and we estimated and visualized the contact points between the patellar and femoral components on a three-dimensional model.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 144 - 144
1 Dec 2013
Onishi Y Hino K Ishimaru M Miura H
Full Access

Introduction:

In posterior cruciate ligament-retaining total knee arthroplasty (CR-TKA), a small bone block (bony island) is often preserved to protect the attachment of the posterior cruciate ligament (PCL), which might be troublesome. In contrast, we prefer to resect the tibial plateau completely to facilitate the surgical procedure. However, there is concern over the increase of the flexion gap due to partial detachment of the PCL. The purpose of the present study is to evaluate the influence of bony island resection on the flexion gap.

Methods:

The subjects were 20 consecutive patients who underwent posterior cruciate ligament-retaining total knee arthroplasty for varus osteoarthritis. There were 18 women, two men, with a mean age of 71.8 years (range, 62–82 years). All operations were performed using posterior cruciate ligament-retaining prosthesis (MERA Quest Knee System, Senko Medical Instrument Manufacturing, Tokyo) by the same senior author with a measured resection technique. The knees were exposed with a medial parapatellar approach. The distal femur was cut and the tibial plateau resection was made with preserving the bony island. The central joint gaps in 90° flexion and full extension were measured using a tensioning device (Offset Repo-Tensor, Zimmer, Warsaw, IN) at 40-lb distracting force. Then, after the resection of the bony island, the central joint gaps were measured by the same method. In addition, the posterior tilt of the tibial resection and the depth of the lateral tibial cut were measured.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 349 - 349
1 Dec 2013
Hino K Ishimaru M Onishi Y Miura H
Full Access

There are some reports that the invasive surgery of knee joint replacement repair static and dynamic balance. We investigated the changes in static and dynamic balance and muscle strength in pre- and postoperative of TKA and UKA for the purpose of assessing time dependent improvement.

A total of 168 patients (137 TKA; mean age 75.3, 31 UKA; mean age 78.1) were recruited to the study. These patients underwent static and dynamic balance assessment and muscle strength pre operation and 3, 6, 12 months post operation. The parameters of assessment were one leg standing time (open or close eyes), postural sway test (open or close eyes), 3m timed-up-and-go test, maximum stride and Isokinetic muscle strength. We have evaluated both the absolute value and the index which divided the value of the post-operation with the value of pre-operation.

Alignment had improved significantly after surgery in TKA and UKA. Isokinetic muscle strength (Fig. 1), one leg standing time with open eyes, 3m timed-up-and-go test (Fig. 2) and maximum stride showed better improvement than pre operation at 3, 6, and 12 months after surgery in TKA and UKA. On the other hand, one leg standing time with close eyes and postural sway test showed no improvement than pre operation at any time after operation (Fig. 3). Butpostural sway test in UKA showed the improvement trend at 3 months after surgery. In contrast, those test in TKA showed no improvement at 3 months after surgery (Fig. 3).

Our result showed the improvement of balance function correlated with muscle recovery and improvement of lower limb alignment than equilibrium function after the artificial knee joint replacement surgery. Because one leg standing time with close eyes and one leg postural sway test represent the equilibrium function than other tests. It is interesting that significant difference in the recovery of postural sway in three months after surgery in UKA compared with TKA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 196 - 196
1 Mar 2013
Hino K Miura H Ishimaru M
Full Access

Functional joint stability and accurate component alignment are crucial for a successful clinical outcome after TKA. However, there are few methods to evaluate joint stability during TKA surgery. Activities of daily living often cause mechanical load to the knee joint not only in full extension but also in mid-flexion. Computer navigation systems are useful for intra-operative monitoring of joint positioning and movements. The purpose of this study was to compare the varus-valgus stability between knees treated with cruciate-retaining (CR) and posterior-stabilized (PS) TKA at different angles in the range of motion (ROM) especially in mid-flexion, using the navigation technique.

Thirty two knees that underwent TKA with computer navigation technology (precisionN Knee Navigation Software version 4.0, Stryker, Kalamazoo, MI) were evaluated (CR:16; PS:16). The investigator gently applied physiologically allowable maximal manual varus-valgus stress to the knee without angular acceleration, while moving the leg from full extension to flexion, and the mechanical femoral-tibial angle was measured automatically by the navigation system at every 10 degrees throughout the ROM. This measurement cycle was repeated for 3 to 4 times, and maximal varus-valgus laxity was determined as the sum of varus and valgus stress angles for each of the predetermined knee flexion angles. The results of the navigated measurements were used to evaluate varus-valgus instability throughout the ROM and the differences in varus-valgus laxity between pre-TKA (Prior to bone cutting, after navigation registration and suturing of the joint capsule) and post-TKA(After confirming that the TKA components and inserts were firmly placed in an appropriate position, the surgical incision was completely closed). The differences in varus-valgus laxity between the CR and PS groups were compared using the Student's t-test.

The knees examined showed the greatest preoperative laxity at 20 to 40 degrees of flexion, with no statistically significant difference between the CR and PS groups (See Figure 1). However, postoperative assessment revealed that PS knees had more varus-valgus laxity than CR knees at all ROM angles examined, and the differences were statistically significant in the flexion range of 10 to 70 degrees (See Figure.2). The differences between preoperative and postoperative joint laxity were analyzed separately for the CR and PS groups. After CR-TKA, joint laxity decreased across all degrees of knee flexion. The differences between preoperative and postoperative joint laxity were statistically significant for the flexion range of 110 to 120 degrees (See Figure.3). On the other hand, knees treated with PS-TKA showed an increase in joint laxity for the flexion range of 10 to 90 degrees. The differences between the preoperative and postoperative values were statistically significant for the flexion range of 10 to 20 degrees in PS-TKA (See Figure.4).

We successfully evaluated varus-valgus laxity in this study using a navigation system. The results showed that PS knees had greater varus-valgus laxity than CR knees throughout the ROM, and the differences were statistically significant for the flexion range of 10 to 70 degrees. Altogether, we conclude that PS knees have more mid-flexion laxity than CR knees.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 79 - 79
1 Mar 2013
Ishimaru M Hino K Miura H
Full Access

Introduction

Accurate alignment and sizing of the femoral component in total knee arthroplasty (TKA) is important for stability and functional outcomes. In relation to the shape of the distal femur, it has been reported that the medial-lateral (ML) femur width in women is narrower than that in men for the same antero-posterior (AP) length. In addition, it has been noted that the elevation of the anterior condyle in women is lower than that in men. Therefore, in TKA for women, it is suggested that a medial or lateral overhanging femoral component can cause pain or limit the range of motion (ROM). As a result, a gender-specific implant for women has been developed. However, there are few studies addressing the morphological dimensions of the distal shape of the femur in the Japanese population. The objective of this study was to reveal the appropriateness of using gender-specific implant for Japanese women.

Methods

This study was based on 40 women (40 knees) and 40 men (40 knees) who had primary preoperative osteoarthritis of the knee. The average height was 161.2 cm for men and 149.4 cm for women. The average weight was 68.0 kg for men and 58.5 kg for women. These are significantly different. Resection of the distal femur for TKA was simulated with preoperative computed tomography (CT) data. The ML width on the anterior and distal cut surface, the ML width at the surgical epicondylar axis (SEA) level, the maximum AP length at the medial and lateral condyle, and the AP length after resection were measured. These values were compared between men and women, and compatibility with NexGen LPS-Flex and Gender Solution Femur (GSF) (Zimmer, Warsow, Ind) was evaluated.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 202 - 202
1 Mar 2013
Ishimaru M Hino K Miura H
Full Access

Introduction

The efficacy and accuracy of computer navigation systems in total knee arthroplasty (TKA) have been proven in recent years. However, potential disadvantages associated with navigation systems, such as increased surgical time and registration errors, have been reported. Currently, we use a navigation system only for the femoral side. We use the conventional extramedullary guide system for the tibial side (hybrid navigation method) because we have increased the accuracy of tibial positioning in the coronal plane with the conventional system by considering the following key points. (1) Set the extramedullary alignment guide to avoid the rotational mismatch between the proximal part of the tibia and the ankle joint. (2) Insert the tibial component along the AP axis of the resected surface. (3) Remove the protruding bone at the antero-lateral edge of the tibia to obtain the flat, resected surface of the tibia. The purpose of this study was to determine the accuracy of the hybrid navigation method.

Methods

We compared the postoperative alignment of 60 TKAs implanted using the conventional alignment guide system with 30 TKAs implanted using the hybrid image-free navigation method. The average age was 74.2 (range, 50 to 85) years in the conventional group and 73.6 (range, 51 to 84) years in the hybrid group. The intramedullary alignment guide was used for the femur in the conventional group. The knees were evaluated using full-length, weight-bearing anteroposterior radiographs.